{"id":3025,"date":"2026-10-08T06:30:38","date_gmt":"2026-10-08T06:30:38","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=3025"},"modified":"2026-10-08T06:30:47","modified_gmt":"2026-10-08T06:30:47","slug":"ha-003-heavy-duty-connector","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/ha-003-heavy-duty-connector\/","title":{"rendered":"Conetor de Servi\u00e7o Pesado de HA-003 3 Polos"},"content":{"rendered":"<h2>Vis\u00e3o Geral<\/h2>\n<p>O conector de alta resist\u00eancia YOCL ELECTRIC HA-003 de 3 polos combina inserts macho e f\u00eamea com terminal de parafuso com os formatos de caixa H3A listados abaixo. Os seus valores el\u00e9tricos de cat\u00e1logo s\u00e3o 10 A e 230\/250 V. As op\u00e7\u00f5es de capuz com entrada superior e entrada lateral suportam cinco configura\u00e7\u00f5es de conjunto completo.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li>Formato de conector HA de 3 polos com inserts macho e f\u00eamea com terminal de parafuso.<\/li>\n<li>Formatos de caixa compactos H3A com capuz de entrada superior ou entrada lateral.<\/li>\n<li>Classifica\u00e7\u00f5es de cat\u00e1logo de 10 A e 230\/250 V.<\/li>\n<li>Rosqueamentos de entrada de cabo listados: M20, PG11.<\/li>\n<li>C\u00f3digos de conjunto completo 5 com pares de caixas exatos listados abaixo.<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Configura\u00e7\u00e3o do produto<\/td>\n<td>HA-003<\/td>\n<\/tr>\n<tr>\n<td>N\u00famero de polos no cat\u00e1logo<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>Corrente nominal<\/td>\n<td>10 A<\/td>\n<\/tr>\n<tr>\n<td>Tens\u00e3o nominal (valor de cat\u00e1logo)<\/td>\n<td>230\/250 V<\/td>\n<\/tr>\n<tr>\n<td>Liga\u00e7\u00e3o de terminal<\/td>\n<td>Terminal de parafuso<\/td>\n<\/tr>\n<tr>\n<td>Op\u00e7\u00f5es de rosca de entrada de cabo listadas<\/td>\n<td>M20, PG11<\/td>\n<\/tr>\n<tr>\n<td>Refer\u00eancia de inflamabilidade do cat\u00e1logo<\/td>\n<td>UL94 V0<\/td>\n<\/tr>\n<tr>\n<td>Designa\u00e7\u00e3o de prote\u00e7\u00e3o do cat\u00e1logo<\/td>\n<td>Refer\u00eancia IP65; DIN 40 050<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>O valor 230\/250 V \u00e9 mantido conforme listado, sem atribui\u00e7\u00e3o de AC\/DC. UL94 V0 \u00e9 uma refer\u00eancia de inflamabilidade. A designa\u00e7\u00e3o do cat\u00e1logo IP65 refere-se \u00e0 configura\u00e7\u00e3o do conector encapsulado; selecione as caixas de acoplamento e os acess\u00f3rios de entrada de cabo em conjunto.<\/p>\n<h3>Inserir Identifica\u00e7\u00e3o<\/h3>\n<table>\n<thead>\n<tr>\n<th>Inserir<\/th>\n<th>Identificador de cat\u00e1logo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Inser\u00e7\u00e3o F\u00eamea<\/td>\n<td>F (etiqueta da figura)<\/td>\n<\/tr>\n<tr>\n<td>Inser\u00e7\u00e3o Macho<\/td>\n<td>M (etiqueta da figura)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Op\u00e7\u00f5es de Caixa<\/h3>\n<table>\n<thead>\n<tr>\n<th>C\u00f3digo da caixa<\/th>\n<th>Formato de cat\u00e1logo vis\u00edvel<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>H3A-MTG<\/td>\n<td>Capuz de entrada superior mostrado no cat\u00e1logo.<\/td>\n<\/tr>\n<tr>\n<td>H3A-MAG<\/td>\n<td>Caixa de acoplamento aberta com ferragens de bloqueio vis\u00edveis.<\/td>\n<\/tr>\n<tr>\n<td>H3A-MTGVB<\/td>\n<td>Caixa de acoplamento com entrada superior e ferragens de bloqueio vis\u00edveis.<\/td>\n<\/tr>\n<tr>\n<td>H3A-MAGSV<\/td>\n<td>Caixa de acoplamento elevada com entrada lateral e ferragens de bloqueio vis\u00edveis.<\/td>\n<\/tr>\n<tr>\n<td>H3A-MTS<\/td>\n<td>Capa com entrada lateral mostrada no cat\u00e1logo.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Configura\u00e7\u00f5es de Conjunto Completo<\/h3>\n<p>Os dois c\u00f3digos de caixa em cada linha seguem a mesma coluna no cat\u00e1logo.<\/p>\n<table>\n<thead>\n<tr>\n<th>C\u00f3digo de encomenda de conjunto completo<\/th>\n<th>Caixa superior<\/th>\n<th>Caixa de acoplamento<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>HA-003-TEOB<\/td>\n<td>H3A-MTG<\/td>\n<td>H3A-MAG<\/td>\n<\/tr>\n<tr>\n<td>HA-003-TETE<\/td>\n<td>H3A-MTG<\/td>\n<td>H3A-MTGVB<\/td>\n<\/tr>\n<tr>\n<td>HA-003-TESE<\/td>\n<td>H3A-MTG<\/td>\n<td>H3A-MAGSV<\/td>\n<\/tr>\n<tr>\n<td>HA-003-SEOB<\/td>\n<td>H3A-MTS<\/td>\n<td>H3A-MAG<\/td>\n<\/tr>\n<tr>\n<td>HA-003-SESE<\/td>\n<td>H3A-MTS<\/td>\n<td>H3A-MAGSV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimens\u00e3o<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ha-003-3-pole-heavy-duty-connector-dimension.webp\" alt=\"Desenho dimensional do conetor de alta resist\u00eancia de HA-003 3 polos\"><\/p>\n<p>Os desenhos de inser\u00e7\u00e3o mostram as seguintes indica\u00e7\u00f5es selecionadas. A sua unidade de medida n\u00e3o \u00e9 indicada. As dimens\u00f5es da caixa e os recortes do painel est\u00e3o separados destas anota\u00e7\u00f5es de inser\u00e7\u00e3o.<\/p>\n<table>\n<thead>\n<tr>\n<th>Etiqueta da figura de inser\u00e7\u00e3o<\/th>\n<th>Indica\u00e7\u00e3o horizontal (unidade n\u00e3o indicada)<\/th>\n<th>Chamada vertical (unidade n\u00e3o especificada)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>F<\/td>\n<td>21<\/td>\n<td>26.2<\/td>\n<\/tr>\n<tr>\n<td>M<\/td>\n<td>21<\/td>\n<td>27<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Guia de Sele\u00e7\u00e3o<\/h2>\n<p>Selecione a configura\u00e7\u00e3o de 3 polos, depois escolha o c\u00f3digo do conjunto completo utilizando o par de caixas H3A exato abaixo. As vers\u00f5es de 3 polos e 4 polos partilham c\u00f3digos de caixa, mas t\u00eam inser\u00e7\u00f5es e identificadores de conjunto completo diferentes.<\/p>\n<p>Solicite a rosca de entrada de cabo necess\u00e1ria juntamente com o par de carca\u00e7as escolhido. A lista de roscas \u00e9 fornecida para esta configura\u00e7\u00e3o de n\u00famero de polos; o cat\u00e1logo n\u00e3o mapeia cada tamanho de rosca para um c\u00f3digo de conjunto completo individual.<\/p>\n<h2>Informa\u00e7\u00f5es de Encomenda<\/h2>\n<p>Forne\u00e7a o c\u00f3digo de encomenda do conjunto completo ou os identificadores de inser\u00e7\u00e3o e concha necess\u00e1rios, a rosca de entrada de cabo e a quantidade. Indique se necessita do conjunto completo ou de componentes individuais.<\/p>","protected":false},"excerpt":{"rendered":"<p>O conector de alta resist\u00eancia YOCL ELECTRIC HA-003 oferece uma configura\u00e7\u00e3o de terminal de parafuso de 3 polos com inserts macho e f\u00eamea e op\u00e7\u00f5es de caixa correspondentes.<\/p>\n<ul>\n<li>Corrente nominal 10 A; tens\u00e3o de cat\u00e1logo 230\/250 V<\/li>\n<li>Rosca de entrada listada: M20, PG11<\/li>\n<li>C\u00f3digos de conjunto completo 5 com detalhes do par de caixas<\/li>\n<li>Formatos de caixa compactos H3A com entrada superior e entrada lateral<\/li>\n<\/ul>","protected":false},"featured_media":3023,"template":"","meta":[],"product_brand":[],"product_cat":[179],"product_tag":[],"class_list":["post-3025","product","type-product","status-publish","has-post-thumbnail","product_cat-heavy-duty-connectors","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/3025","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/3023"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=3025"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=3025"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=3025"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=3025"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}