{"id":675,"date":"2026-09-29T11:18:28","date_gmt":"2026-09-29T11:18:28","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=675"},"modified":"2026-10-04T11:25:53","modified_gmt":"2026-10-04T11:25:53","slug":"sv-pre-insulating-fork-terminal-tu-jtk","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/sv-pre-insulating-fork-terminal-tu-jtk\/","title":{"rendered":"SV Series Pre-insulating Fork Terminal (TU-JTK Type)"},"content":{"rendered":"<h2>Overview<\/h2>\n<p>YOCL ELECTRIC SV Series Pre-insulating Fork Terminal (TU-JTK Type) is a copper fork terminal with a pre-insulated barrel. Its fork contact is intended for compatible screw terminal connections. The catalogue lists 43 SV models across seven size groups, with model-specific bolt and dimensional data.<\/p>\n<h2>Features<\/h2>\n<ul>\n<li><strong>Fork contact:<\/strong> fits a compatible screw terminal without removing the screw completely.<\/li>\n<li><strong>Pre-insulated barrel:<\/strong> the sleeve covers the conductor connection area.<\/li>\n<li><strong>Size-based identification:<\/strong> conductor group, color and maximum current are stated by the reference table.<\/li>\n<li><strong>Model-specific fit:<\/strong> bolt size, fork opening and body dimensions vary across the 43 models.<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Series<\/td>\n<td>SV<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Pre-insulating fork terminal<\/td>\n<\/tr>\n<tr>\n<td>Terminal material<\/td>\n<td>Copper<\/td>\n<\/tr>\n<tr>\n<td>Insulation<\/td>\n<td>Pre-insulated sleeve; PVC is explicitly specified for the 1.25 and 2 size groups<\/td>\n<\/tr>\n<tr>\n<td>Listed models<\/td>\n<td>43<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Group specifications below apply to every listed model in that group. The copper thickness is the material thickness given in the catalogue, not an insulation rating.<\/p>\n<table>\n<thead>\n<tr>\n<th>Size group<\/th>\n<th>Conductor section (mm\u00b2)<\/th>\n<th>AWG<\/th>\n<th>Max current (A)<\/th>\n<th>Color<\/th>\n<th>Copper thickness (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1.25<\/td>\n<td>0.5\u20131.5<\/td>\n<td>22\u201316<\/td>\n<td>19<\/td>\n<td>Red<\/td>\n<td>0.7<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>1.5\u20132.5<\/td>\n<td>16\u201314<\/td>\n<td>27<\/td>\n<td>Blue<\/td>\n<td>0.8<\/td>\n<\/tr>\n<tr>\n<td>3.5<\/td>\n<td>2.5\u20134<\/td>\n<td>14\u201312<\/td>\n<td>37<\/td>\n<td>Black<\/td>\n<td>1.0<\/td>\n<\/tr>\n<tr>\n<td>5.5<\/td>\n<td>4\u20136<\/td>\n<td>12\u201310<\/td>\n<td>48<\/td>\n<td>Yellow<\/td>\n<td>1.0<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>8\u201310<\/td>\n<td>8<\/td>\n<td>62<\/td>\n<td>Red<\/td>\n<td>1.2<\/td>\n<\/tr>\n<tr>\n<td>14<\/td>\n<td>10\u201316<\/td>\n<td>6<\/td>\n<td>88<\/td>\n<td>Blue<\/td>\n<td>1.5<\/td>\n<\/tr>\n<tr>\n<td>22<\/td>\n<td>Not stated<\/td>\n<td>Not stated<\/td>\n<td>115<\/td>\n<td>Yellow<\/td>\n<td>0.8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimension<\/h2>\n<p>All dimensions are in millimeters. The fork opening d2, width B, fork length F, overall length L, body length E and insulated barrel diameter D1 follow the reference drawing.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>US bolt<\/th>\n<th>d2 (mm)<\/th>\n<th>B (mm)<\/th>\n<th>F (mm)<\/th>\n<th>L (mm)<\/th>\n<th>E (mm)<\/th>\n<th>D1 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SV 1.25-3<\/td>\n<td>#4<\/td>\n<td>3.2<\/td>\n<td>5.7<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<\/tr>\n<tr>\n<td>SV 1.25-3.5S<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>5.7<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<\/tr>\n<tr>\n<td>SV 1.25-3.5L<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>6.4<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<\/tr>\n<tr>\n<td>SV 1.25-4S<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>6.4<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<\/tr>\n<tr>\n<td>SV 1.25-4M<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>7.2<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<\/tr>\n<tr>\n<td>SV 1.25-4L<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.1<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<\/tr>\n<tr>\n<td>SV 1.25-5S<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>8.1<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<\/tr>\n<tr>\n<td>SV 1.25-5L<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<\/tr>\n<tr>\n<td>SV 1.25-6S<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>9.5<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<\/tr>\n<tr>\n<td>SV 1.25-6L<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>11.0<\/td>\n<td>27.2<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<\/tr>\n<tr>\n<td>SV 1.25-8<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>14.0<\/td>\n<td>12.0<\/td>\n<td>29.2<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<\/tr>\n<tr>\n<td>SV 2-3<\/td>\n<td>#4<\/td>\n<td>3.2<\/td>\n<td>5.7<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<\/tr>\n<tr>\n<td>SV 2-3.5S<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>5.7<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<\/tr>\n<tr>\n<td>SV 2-3.5L<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>6.4<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<\/tr>\n<tr>\n<td>SV 2-4S<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>6.4<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<\/tr>\n<tr>\n<td>SV 2-4M<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>7.2<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<\/tr>\n<tr>\n<td>SV 2-4L<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.1<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<\/tr>\n<tr>\n<td>SV 2-5S<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>8.1<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<\/tr>\n<tr>\n<td>SV 2-5L<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<\/tr>\n<tr>\n<td>SV 2-6S<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>9.5<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<\/tr>\n<tr>\n<td>SV 2-6L<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>11.0<\/td>\n<td>27.2<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<\/tr>\n<tr>\n<td>SV 2-8<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>14.0<\/td>\n<td>12.5<\/td>\n<td>29.2<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<\/tr>\n<tr>\n<td>SV 3.5-3.5<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>25.3<\/td>\n<td>13.0<\/td>\n<td>6.3<\/td>\n<\/tr>\n<tr>\n<td>SV 3.5-4<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>25.3<\/td>\n<td>13.0<\/td>\n<td>6.3<\/td>\n<\/tr>\n<tr>\n<td>SV 3.5-5S<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>25.3<\/td>\n<td>13.0<\/td>\n<td>6.3<\/td>\n<\/tr>\n<tr>\n<td>SV 3.5-6S<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>9.0<\/td>\n<td>7.5<\/td>\n<td>26.5<\/td>\n<td>13.0<\/td>\n<td>6.3<\/td>\n<\/tr>\n<tr>\n<td>SV 3.5-6<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>12.1<\/td>\n<td>28.5<\/td>\n<td>13.0<\/td>\n<td>6.3<\/td>\n<\/tr>\n<tr>\n<td>SV 5.5-3.5<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>8.3<\/td>\n<td>7.5<\/td>\n<td>26.5<\/td>\n<td>13.0<\/td>\n<td>6.7<\/td>\n<\/tr>\n<tr>\n<td>SV 5.5-4S<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.3<\/td>\n<td>7.5<\/td>\n<td>26.5<\/td>\n<td>13.0<\/td>\n<td>6.7<\/td>\n<\/tr>\n<tr>\n<td>SV 5.5-4L<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>9.0<\/td>\n<td>7.5<\/td>\n<td>26.5<\/td>\n<td>13.0<\/td>\n<td>6.7<\/td>\n<\/tr>\n<tr>\n<td>SV 5.5-5<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.0<\/td>\n<td>7.5<\/td>\n<td>26.5<\/td>\n<td>13.0<\/td>\n<td>6.7<\/td>\n<\/tr>\n<tr>\n<td>SV 5.5-6S<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>9.0<\/td>\n<td>7.5<\/td>\n<td>26.5<\/td>\n<td>13.0<\/td>\n<td>6.7<\/td>\n<\/tr>\n<tr>\n<td>SV 5.5-6L<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>12.0<\/td>\n<td>32.5<\/td>\n<td>13.0<\/td>\n<td>6.7<\/td>\n<\/tr>\n<tr>\n<td>SV 5.5-8<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>14.0<\/td>\n<td>11.5<\/td>\n<td>31.5<\/td>\n<td>13.0<\/td>\n<td>6.7<\/td>\n<\/tr>\n<tr>\n<td>SV 8-4<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.0<\/td>\n<td>7.2<\/td>\n<td>30.0<\/td>\n<td>15.5<\/td>\n<td>8.5<\/td>\n<\/tr>\n<tr>\n<td>SV 8-5<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>10.8<\/td>\n<td>7.2<\/td>\n<td>30.0<\/td>\n<td>15.5<\/td>\n<td>8.5<\/td>\n<\/tr>\n<tr>\n<td>SV 8-6<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>10.8<\/td>\n<td>7.2<\/td>\n<td>30.0<\/td>\n<td>15.5<\/td>\n<td>8.5<\/td>\n<\/tr>\n<tr>\n<td>SV 8-8<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>14.5<\/td>\n<td>10.7<\/td>\n<td>35.0<\/td>\n<td>15.5<\/td>\n<td>8.5<\/td>\n<\/tr>\n<tr>\n<td>SV 14-5<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>11.0<\/td>\n<td>10.7<\/td>\n<td>35.2<\/td>\n<td>21.1<\/td>\n<td>10.5<\/td>\n<\/tr>\n<tr>\n<td>SV 14-6<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>11.0<\/td>\n<td>10.7<\/td>\n<td>35.2<\/td>\n<td>21.1<\/td>\n<td>10.5<\/td>\n<\/tr>\n<tr>\n<td>SV 14-8<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>14.0<\/td>\n<td>10.7<\/td>\n<td>35.2<\/td>\n<td>21.1<\/td>\n<td>10.5<\/td>\n<\/tr>\n<tr>\n<td>SV 22-6<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>14.0<\/td>\n<td>9.5<\/td>\n<td>39.2<\/td>\n<td>23.2<\/td>\n<td>13.0<\/td>\n<\/tr>\n<tr>\n<td>SV 22-8<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>14.0<\/td>\n<td>13.5<\/td>\n<td>39.2<\/td>\n<td>23.2<\/td>\n<td>13.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/09\/sv-series-pre-insulating-fork-terminal-tu-jtk-type-dimension.webp\" alt=\"SV Series Pre-insulating Fork Terminal (TU-JTK Type) dimension drawing\" \/><\/p>\n<h2>Selection Guide<\/h2>\n<p>Select the SV conductor group first, then match the US bolt number and fork opening d2 to the terminal screw. Compare B, F, L, E and D1 with the available space. The reference does not state a conductor range for the SV 22 group.<\/p>\n<h2>Aplica\u00e7\u00f5es<\/h2>\n<p>For conductor connections to compatible screw terminals in electrical equipment.<\/p>\n<h2>Ordering Information<\/h2>\n<p>Provide the full SV model and quantity when requesting a quotation.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC SV Series Pre-insulating Fork Terminal (TU-JTK Type) provides a fork connection for compatible screw terminals.<\/p>\n<ul>\n<li>43 listed SV models across seven catalogue size groups.<\/li>\n<li>Copper terminal with pre-insulated barrel; insulation color varies by group.<\/li>\n<li>Group maximum current values range from 19 to 115 A as listed in the reference.<\/li>\n<li>Model table includes bolt size, opening d2, B, F, L, E and D1 dimensions.<\/li>\n<\/ul>","protected":false},"featured_media":2067,"template":"","meta":[],"product_brand":[],"product_cat":[158],"product_tag":[],"class_list":["post-675","product","type-product","status-publish","has-post-thumbnail","product_cat-pvc-insulated-terminals","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/675","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/2067"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=675"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=675"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=675"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=675"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}