{"id":921,"date":"2026-09-29T17:42:42","date_gmt":"2026-09-29T17:42:42","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=921"},"modified":"2026-10-04T07:24:26","modified_gmt":"2026-10-04T07:24:26","slug":"vo-multiple-waterproof-brass-cable-gland","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/vo-multiple-waterproof-brass-cable-gland\/","title":{"rendered":"Multiple Waterproof Brass Cable Gland"},"content":{"rendered":"<h2>Vis\u00e3o Geral<\/h2>\n<p>YOCL ELECTRIC Multiple Waterproof Brass Cable Glands provide multiple cable openings in one threaded metal gland. The listed construction uses a nickel-plated brass body, a PA clamping component and NBR seals. The catalogue shows 18 Metric, PG and G thread patterns and configurations for two to eight cable openings.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li><strong>Multiple cable openings:<\/strong> routes several cables through one gland body while keeping their individual openings separated.<\/li>\n<li><strong>Nickel-plated brass body:<\/strong> metal construction and finish specified for the series.<\/li>\n<li><strong>PA clamping component and NBR sealing parts:<\/strong> materials identified for the gland assembly.<\/li>\n<li><strong>IP68 protection grade:<\/strong> stated for correct installation within the applicable clamping ranges.<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Product type<\/td>\n<td>Multi-hole waterproof metal cable gland<\/td>\n<\/tr>\n<tr>\n<td>Body material<\/td>\n<td>Nickel-plated brass<\/td>\n<\/tr>\n<tr>\n<td>Clamping component<\/td>\n<td>PA<\/td>\n<\/tr>\n<tr>\n<td>Seal and O-ring<\/td>\n<td>NBR<\/td>\n<\/tr>\n<tr>\n<td>Thread systems with listed configurations<\/td>\n<td>Metric, PG and G<\/td>\n<\/tr>\n<tr>\n<td>Openings shown<\/td>\n<td>Two to eight, depending on thread pattern<\/td>\n<\/tr>\n<tr>\n<td>Protection grade<\/td>\n<td>IP68, subject to correct assembly and clamping range<\/td>\n<\/tr>\n<tr>\n<td>Static operating temperature<\/td>\n<td>\u221240 to +100 \u00b0C; short-term to +120 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Dynamic operating temperature<\/td>\n<td>\u221220 to +80 \u00b0C; short-term to +100 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Listed thread\/code patterns<\/td>\n<td>18<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimens\u00e3o<\/h2>\n<p>Cable diameter ranges in columns M2\u2013M8 are in millimeters and are shown from smaller to larger diameter. A slash means the catalogue does not list that configuration. The F column is reproduced as a catalogue designation because its meaning is not defined in the supplied material. An asterisk in each code is a placeholder, not a complete orderable suffix.<\/p>\n<table>\n<thead>\n<tr>\n<th>Code pattern<\/th>\n<th>Thread<\/th>\n<th>F (catalogue)<\/th>\n<th>M2 (mm)<\/th>\n<th>M3 (mm)<\/th>\n<th>M4 (mm)<\/th>\n<th>M5 (mm)<\/th>\n<th>M6 (mm)<\/th>\n<th>M7 (mm)<\/th>\n<th>M8 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>VO-M12\/*<\/td>\n<td>M12\u00d71.5<\/td>\n<td>\/<\/td>\n<td>1.2\u20133<\/td>\n<td>1.2\u20132.6<\/td>\n<td>1\u20132.3<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>VO-M16\/*<\/td>\n<td>M16\u00d71.5<\/td>\n<td>\/<\/td>\n<td>1.6\u20134<\/td>\n<td>1.2\u20132.6<\/td>\n<td>1\u20132.3<\/td>\n<td>1.0\u20132.5<\/td>\n<td>1.0\u20132.0<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>VO-M18\/*<\/td>\n<td>M18\u00d71.5<\/td>\n<td>6\u00d710<\/td>\n<td>2\u20133.5<\/td>\n<td>1.6\u20134<\/td>\n<td>1.2\u20133<\/td>\n<td>1.5\u20132.6<\/td>\n<td>1\u20132.2<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>VO-M20\/*<\/td>\n<td>M20\u00d71.5<\/td>\n<td>5\u00d711.5<\/td>\n<td>1.5\u20135.3<\/td>\n<td>2\u20135<\/td>\n<td>1.7\u20134.2<\/td>\n<td>1.2\u20133<\/td>\n<td>1.2\u20133<\/td>\n<td>1.2\u20133<\/td>\n<td>1.2\u20133<\/td>\n<\/tr>\n<tr>\n<td>VO-M22\/*<\/td>\n<td>M22\u00d71.5<\/td>\n<td>6\u00d714<\/td>\n<td>2.5\u20136<\/td>\n<td>1.5\u20133.5<\/td>\n<td>2\u20134.5<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>VO-M25\/*<\/td>\n<td>M25\u00d71.5<\/td>\n<td>6\u00d714<\/td>\n<td>4\u20138.7<\/td>\n<td>4\u20138<\/td>\n<td>2\u20135<\/td>\n<td>1.5\u20133.5<\/td>\n<td>1.5\u20133.5<\/td>\n<td>1.5\u20133.5<\/td>\n<td>1.5\u20133.5<\/td>\n<\/tr>\n<tr>\n<td>VO-M27\/*<\/td>\n<td>M27\u00d71.5<\/td>\n<td>7\u00d718<\/td>\n<td>4.5\u20138.7<\/td>\n<td>2\u20135<\/td>\n<td>3.5\u20137<\/td>\n<td>1.5\u20133.5<\/td>\n<td>1.5\u20133.5<\/td>\n<td>1.5\u20133.5<\/td>\n<td>1.5\u20133.5<\/td>\n<\/tr>\n<tr>\n<td>VO-M32\/*<\/td>\n<td>M32\u00d71.5<\/td>\n<td>8\u00d722<\/td>\n<td>5\u201310<\/td>\n<td>5\u201310<\/td>\n<td>4.5\u20139<\/td>\n<td>4.0\u20138.0<\/td>\n<td>3.5\u20137<\/td>\n<td>3\u20136<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>VO-PG7\/*<\/td>\n<td>PG7<\/td>\n<td>\/<\/td>\n<td>1.2\u20133<\/td>\n<td>1.2\u20132.6<\/td>\n<td>1\u20132.3<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>VO-PG9\/*<\/td>\n<td>PG9<\/td>\n<td>\/<\/td>\n<td>1.6\u20134<\/td>\n<td>1.2\u20132.6<\/td>\n<td>1\u20132.3<\/td>\n<td>1.0\u20132.5<\/td>\n<td>1\u20132<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>VO-PG11\/*<\/td>\n<td>PG11<\/td>\n<td>6\u00d710<\/td>\n<td>2\u20133.5<\/td>\n<td>1.6\u20134<\/td>\n<td>1.2\u20133<\/td>\n<td>1.5\u20132.6<\/td>\n<td>1\u20132.2<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>VO-PG13.5\/*<\/td>\n<td>PG13.5<\/td>\n<td>5\u00d711.5<\/td>\n<td>1.5\u20135.3<\/td>\n<td>1.5\u20133.5<\/td>\n<td>1.7\u20134.2<\/td>\n<td>1.7\u20134.2<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>VO-PG16\/*<\/td>\n<td>PG16<\/td>\n<td>6\u00d714<\/td>\n<td>2.5\u20136<\/td>\n<td>1.5\u20133.5<\/td>\n<td>2\u20134.5<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>VO-PG21\/*<\/td>\n<td>PG21<\/td>\n<td>7\u00d718<\/td>\n<td>4.5\u20138.7<\/td>\n<td>2\u20135<\/td>\n<td>3.5\u20137<\/td>\n<td>1.5\u20133.5<\/td>\n<td>1.5\u20133.5<\/td>\n<td>1.5\u20133.5<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>VO-PG29\/*<\/td>\n<td>PG29<\/td>\n<td>8\u00d722<\/td>\n<td>5\u201310<\/td>\n<td>5\u201310<\/td>\n<td>4.5\u20139<\/td>\n<td>4.0\u20138.0<\/td>\n<td>3.5\u20137<\/td>\n<td>3\u20136<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>VO-G1\/2\/*<\/td>\n<td>G1\/2<\/td>\n<td>5\u00d711.5<\/td>\n<td>1.5\u20135.3<\/td>\n<td>2\u20135<\/td>\n<td>1.7\u20134.2<\/td>\n<td>1.2\u20133<\/td>\n<td>1.2\u20133<\/td>\n<td>1.2\u20133<\/td>\n<td>1.2\u20133<\/td>\n<\/tr>\n<tr>\n<td>VO-G3\/4\/*<\/td>\n<td>G3\/4<\/td>\n<td>7\u00d718<\/td>\n<td>4.5\u20138.7<\/td>\n<td>2\u20135<\/td>\n<td>3.5\u20137<\/td>\n<td>1.5\u20133.5<\/td>\n<td>1.5\u20133.5<\/td>\n<td>1.5\u20133.5<\/td>\n<td>1.5\u20133.5<\/td>\n<\/tr>\n<tr>\n<td>VO-G1\/*<\/td>\n<td>G1<\/td>\n<td>8\u00d722<\/td>\n<td>5\u201310<\/td>\n<td>5\u201310<\/td>\n<td>4.5\u20139<\/td>\n<td>4.0\u20138.0<\/td>\n<td>3.5\u20137<\/td>\n<td>3\u20136<\/td>\n<td>\/<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/09\/multiple-waterproof-brass-cable-gland-dimension.webp\" alt=\"Multiple Waterproof Brass Cable Gland dimension drawing\" \/><\/p>\n<h2>Guia de Sele\u00e7\u00e3o<\/h2>\n<p>Choose the thread system and size, then the required number of separate cable openings. Check each cable outside diameter against the applicable M2\u2013M8 range. Give the exact cable diameters and opening count when requesting a complete order code.<\/p>\n<h2>Informa\u00e7\u00f5es de Encomenda<\/h2>\n<p>Provide the thread pattern, opening count, cable diameters and required quantity when requesting a quotation. The catalogue code patterns contain <code>*<\/code>; request the completed order code for the selected configuration.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC Multiple Waterproof Brass Cable Glands provide multiple sealed cable entries through one gland body. The catalogue lists 18 Metric, PG and G thread patterns with configurations for two to eight cable openings.<\/p>\n<ul>\n<li>Nickel-plated brass body, PA clamping component and NBR seal and O-ring.<\/li>\n<li>IP68 protection grade stated for correct assembly within the applicable cable ranges.<\/li>\n<li>Specify the thread, number of openings and cable diameters when inquiring; <code>*<\/code> in the catalogue code is a placeholder.<\/li>\n<\/ul>","protected":false},"featured_media":2027,"template":"","meta":[],"product_brand":[],"product_cat":[88],"product_tag":[],"class_list":["post-921","product","type-product","status-publish","has-post-thumbnail","product_cat-metal-cable-glands","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/921","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/2027"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=921"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=921"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=921"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=921"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}