{"id":929,"date":"2026-09-29T17:45:20","date_gmt":"2026-09-29T17:45:20","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=929"},"modified":"2026-10-04T06:58:29","modified_gmt":"2026-10-04T06:58:29","slug":"vo-dl-double-locked-brass-cable-glands","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/vo-dl-double-locked-brass-cable-glands\/","title":{"rendered":"VO-DL Double-Locked Brass Cable Glands"},"content":{"rendered":"<h2>Vis\u00e3o Geral<\/h2>\n<p>VO-DL Double-Locked Brass Cable Glands provide cable entry, sealing and retention at electrical enclosures. The supplied catalog lists 38 models in PG and metric thread groups, each with a cable clamping range and installation dimensions.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li><strong>Double-locking construction:<\/strong> the source identifies this design for cable sealing and retention where resistance to pull is important.<\/li>\n<li><strong>Nickel-plated brass body:<\/strong> the stated metal material for this series.<\/li>\n<li><strong>PA nylon claw and NBR seal:<\/strong> the listed clamping and sealing components.<\/li>\n<li><strong>Catalog-stated IP68:<\/strong> the source specifies cable within the clamping range and an O-ring seated in the groove. No product test report was supplied.<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Catalog specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Product type<\/td>\n<td>Double-locked metal cable gland<\/td>\n<\/tr>\n<tr>\n<td>Series<\/td>\n<td>VO-DL<\/td>\n<\/tr>\n<tr>\n<td>Listed models<\/td>\n<td>38<\/td>\n<\/tr>\n<tr>\n<td>Thread families<\/td>\n<td>PG and metric<\/td>\n<\/tr>\n<tr>\n<td>Cable diameter range<\/td>\n<td>3\u201344 mm across listed models; check each model<\/td>\n<\/tr>\n<tr>\n<td>Body material<\/td>\n<td>Nickel-plated brass<\/td>\n<\/tr>\n<tr>\n<td>Claw material<\/td>\n<td>PA nylon<\/td>\n<\/tr>\n<tr>\n<td>Sealing material<\/td>\n<td>NBR<\/td>\n<\/tr>\n<tr>\n<td>Protection class<\/td>\n<td>IP68 stated by source under specified clamping and O-ring conditions<\/td>\n<\/tr>\n<tr>\n<td>Ambient temperature<\/td>\n<td>\u221240 to +100 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Dimension units<\/td>\n<td>mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The source cites EN 50262 and EN 62444 as test standards but supplies no model-specific test report or certification. It does not give tightening torque, metric thread pitch, price or stock.<\/p>\n<h2>Dimens\u00e3o<\/h2>\n<p>The tables provide the exact model code, cable range, thread length, body height, spanner size, thread outside diameter and panel mounting hole. The metric table labels threads by nominal size only; pitch must be verified before installation.<\/p>\n<h3>PG Thread Models<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Thread designation<\/th>\n<th>Cable range (mm)<\/th>\n<th>Thread length (mm)<\/th>\n<th>Body height (mm)<\/th>\n<th>Spanner size (mm)<\/th>\n<th>Thread OD (mm)<\/th>\n<th>Panel mounting hole (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>VO-PG7-DL<\/td>\n<td>PG7<\/td>\n<td>3\u20136.5<\/td>\n<td>5<\/td>\n<td>25<\/td>\n<td>14<\/td>\n<td>12.5<\/td>\n<td>12.5\u201312.8<\/td>\n<\/tr>\n<tr>\n<td>VO-PG9-DL<\/td>\n<td>PG9<\/td>\n<td>4\u20138<\/td>\n<td>6<\/td>\n<td>27<\/td>\n<td>17<\/td>\n<td>15.2<\/td>\n<td>15.2\u201315.5<\/td>\n<\/tr>\n<tr>\n<td>VO-PG11-DL<\/td>\n<td>PG11<\/td>\n<td>5\u201310<\/td>\n<td>6<\/td>\n<td>29<\/td>\n<td>20<\/td>\n<td>18.6<\/td>\n<td>18.6\u201318.9<\/td>\n<\/tr>\n<tr>\n<td>VO-PG13.5-DL<\/td>\n<td>PG13.5<\/td>\n<td>6\u201312<\/td>\n<td>6.5<\/td>\n<td>31<\/td>\n<td>22<\/td>\n<td>20.4<\/td>\n<td>20.4\u201320.7<\/td>\n<\/tr>\n<tr>\n<td>VO-PG16-DL<\/td>\n<td>PG16<\/td>\n<td>10\u201314<\/td>\n<td>6.5<\/td>\n<td>31<\/td>\n<td>24<\/td>\n<td>22.5<\/td>\n<td>22.5\u201322.8<\/td>\n<\/tr>\n<tr>\n<td>VO-PG21-DL<\/td>\n<td>PG21<\/td>\n<td>13\u201318<\/td>\n<td>7<\/td>\n<td>37<\/td>\n<td>30<\/td>\n<td>28.3<\/td>\n<td>28.3\u201328.6<\/td>\n<\/tr>\n<tr>\n<td>VO-PG29-DL<\/td>\n<td>PG29<\/td>\n<td>18\u201325<\/td>\n<td>8<\/td>\n<td>42<\/td>\n<td>40<\/td>\n<td>37<\/td>\n<td>37\u201337.3<\/td>\n<\/tr>\n<tr>\n<td>VO-PG36-DL<\/td>\n<td>PG36<\/td>\n<td>22\u201332<\/td>\n<td>8<\/td>\n<td>48<\/td>\n<td>50<\/td>\n<td>47<\/td>\n<td>47\u201347.3<\/td>\n<\/tr>\n<tr>\n<td>VO-PG42-DL<\/td>\n<td>PG42<\/td>\n<td>32\u201338<\/td>\n<td>9<\/td>\n<td>50<\/td>\n<td>57<\/td>\n<td>54<\/td>\n<td>54\u201354.3<\/td>\n<\/tr>\n<tr>\n<td>VO-PG48-DL<\/td>\n<td>PG48<\/td>\n<td>37\u201344<\/td>\n<td>10<\/td>\n<td>51<\/td>\n<td>64<\/td>\n<td>59.3<\/td>\n<td>59.3\u201359.6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Metric Thread Models<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Thread designation<\/th>\n<th>Cable range (mm)<\/th>\n<th>Thread length (mm)<\/th>\n<th>Body height (mm)<\/th>\n<th>Spanner size (mm)<\/th>\n<th>Thread OD (mm)<\/th>\n<th>Panel mounting hole (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>VO-M12A-DL<\/td>\n<td>M12A<\/td>\n<td>3\u20136.5<\/td>\n<td>5<\/td>\n<td>25<\/td>\n<td>14<\/td>\n<td>12<\/td>\n<td>12\u201312.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M12B-DL<\/td>\n<td>M12B<\/td>\n<td>4\u20138<\/td>\n<td>6<\/td>\n<td>27<\/td>\n<td>17<\/td>\n<td>12<\/td>\n<td>12\u201312.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M14-DL<\/td>\n<td>M14<\/td>\n<td>4\u20138<\/td>\n<td>6<\/td>\n<td>27<\/td>\n<td>17<\/td>\n<td>14<\/td>\n<td>14\u201314.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M16A-DL<\/td>\n<td>M16A<\/td>\n<td>4\u20138<\/td>\n<td>6<\/td>\n<td>27<\/td>\n<td>17<\/td>\n<td>16<\/td>\n<td>16\u201316.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M16B-DL<\/td>\n<td>M16B<\/td>\n<td>5\u201310<\/td>\n<td>6<\/td>\n<td>29<\/td>\n<td>20<\/td>\n<td>16<\/td>\n<td>16\u201316.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M18-DL<\/td>\n<td>M18<\/td>\n<td>5\u201310<\/td>\n<td>6<\/td>\n<td>29<\/td>\n<td>20<\/td>\n<td>18<\/td>\n<td>18\u201318.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M20A-DL<\/td>\n<td>M20A<\/td>\n<td>6\u201312<\/td>\n<td>6.5<\/td>\n<td>31<\/td>\n<td>22<\/td>\n<td>20<\/td>\n<td>20\u201320.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M20B-DL<\/td>\n<td>M20B<\/td>\n<td>10\u201314<\/td>\n<td>6.5<\/td>\n<td>31<\/td>\n<td>24<\/td>\n<td>20<\/td>\n<td>20\u201320.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M22-DL<\/td>\n<td>M22<\/td>\n<td>10\u201314<\/td>\n<td>6.5<\/td>\n<td>31<\/td>\n<td>24<\/td>\n<td>22<\/td>\n<td>22\u201322.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M24-DL<\/td>\n<td>M24<\/td>\n<td>10\u201314<\/td>\n<td>6.5<\/td>\n<td>31<\/td>\n<td>24\/27<\/td>\n<td>24<\/td>\n<td>24\u201324.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M25-DL<\/td>\n<td>M25<\/td>\n<td>13\u201318<\/td>\n<td>7<\/td>\n<td>37<\/td>\n<td>30<\/td>\n<td>25<\/td>\n<td>25\u201325.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M27-DL<\/td>\n<td>M27<\/td>\n<td>13\u201318<\/td>\n<td>7<\/td>\n<td>37<\/td>\n<td>30<\/td>\n<td>27<\/td>\n<td>27\u201327.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M28-DL<\/td>\n<td>M28<\/td>\n<td>13\u201318<\/td>\n<td>7<\/td>\n<td>37<\/td>\n<td>30<\/td>\n<td>28<\/td>\n<td>28\u201328.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M30-DL<\/td>\n<td>M30<\/td>\n<td>13\u201318<\/td>\n<td>8<\/td>\n<td>37<\/td>\n<td>30\/32<\/td>\n<td>30<\/td>\n<td>30\u201330.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M32-DL<\/td>\n<td>M32<\/td>\n<td>18\u201325<\/td>\n<td>8<\/td>\n<td>42<\/td>\n<td>40<\/td>\n<td>32<\/td>\n<td>32\u201332.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M33-DL<\/td>\n<td>M33<\/td>\n<td>18\u201325<\/td>\n<td>8<\/td>\n<td>42<\/td>\n<td>40<\/td>\n<td>33<\/td>\n<td>33\u201333.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M36-DL<\/td>\n<td>M36<\/td>\n<td>18\u201325<\/td>\n<td>8<\/td>\n<td>42<\/td>\n<td>40<\/td>\n<td>36<\/td>\n<td>36\u201336.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M37-DL<\/td>\n<td>M37<\/td>\n<td>18\u201325<\/td>\n<td>8<\/td>\n<td>42<\/td>\n<td>40<\/td>\n<td>37<\/td>\n<td>37\u201337.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M40-DL<\/td>\n<td>M40<\/td>\n<td>22\u201332<\/td>\n<td>8<\/td>\n<td>48<\/td>\n<td>50<\/td>\n<td>40<\/td>\n<td>40\u201340.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M42-DL<\/td>\n<td>M42<\/td>\n<td>22\u201332<\/td>\n<td>8<\/td>\n<td>48<\/td>\n<td>50<\/td>\n<td>42<\/td>\n<td>42\u201342.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M47-DL<\/td>\n<td>M47<\/td>\n<td>22\u201332<\/td>\n<td>8<\/td>\n<td>48<\/td>\n<td>50<\/td>\n<td>47<\/td>\n<td>47\u201347.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M48-DL<\/td>\n<td>M48<\/td>\n<td>22\u201332<\/td>\n<td>8<\/td>\n<td>48<\/td>\n<td>50\/52<\/td>\n<td>48<\/td>\n<td>48\u201348.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M50-DL<\/td>\n<td>M50<\/td>\n<td>32\u201338<\/td>\n<td>9<\/td>\n<td>50<\/td>\n<td>57<\/td>\n<td>50<\/td>\n<td>50\u201350.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M54-DL<\/td>\n<td>M54<\/td>\n<td>32\u201338<\/td>\n<td>9<\/td>\n<td>50<\/td>\n<td>57<\/td>\n<td>54<\/td>\n<td>54\u201354.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M56-DL<\/td>\n<td>M56<\/td>\n<td>32\u201338<\/td>\n<td>9<\/td>\n<td>50<\/td>\n<td>57\/59<\/td>\n<td>56<\/td>\n<td>56\u201356.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M60-DL<\/td>\n<td>M60<\/td>\n<td>37\u201344<\/td>\n<td>10<\/td>\n<td>51<\/td>\n<td>64<\/td>\n<td>60<\/td>\n<td>60\u201360.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M63-DL<\/td>\n<td>M63<\/td>\n<td>37\u201344<\/td>\n<td>10<\/td>\n<td>51<\/td>\n<td>64\/68<\/td>\n<td>63<\/td>\n<td>63\u201363.3<\/td>\n<\/tr>\n<tr>\n<td>VO-M64-DL<\/td>\n<td>M64<\/td>\n<td>37\u201344<\/td>\n<td>10<\/td>\n<td>51<\/td>\n<td>64<\/td>\n<td>64<\/td>\n<td>64\u201364.3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Guia de Sele\u00e7\u00e3o<\/h2>\n<p>Choose a model whose stated cable range contains the actual cable outside diameter. Match its thread designation and panel mounting hole to the enclosure, then check thread length and body height. Confirm the metric thread pitch with the supplier because it is absent from the supplied table.<\/p>\n<h2>Dimens\u00e3o<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/09\/vo-dl-double-locked-brass-cable-glands-dimension.webp\" alt=\"VO-DL Double-Locked Brass Cable Glands dimension drawing\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/09\/vo-dl-double-locked-brass-cable-glands-dimension-02.webp\" alt=\"VO-DL Double-Locked Brass Cable Glands dimension drawing\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>VO-DL double-locked brass cable glands use a nickel-plated brass body, PA nylon claw and NBR seal. The catalog lists 38 PG and metric models for cable diameters from 3 to 44 mm across the series.<\/p>\n<ul>\n<li>Double-locking construction is intended for cable sealing and retention.<\/li>\n<li>Source-stated IP68 applies with cable within the clamping range and the O-ring seated.<\/li>\n<li>Select by exact model, cable diameter, panel hole, thread length and body height.<\/li>\n<\/ul>","protected":false},"featured_media":2016,"template":"","meta":[],"product_brand":[],"product_cat":[88],"product_tag":[],"class_list":["post-929","product","type-product","status-publish","has-post-thumbnail","product_cat-metal-cable-glands","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/929","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/2016"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=929"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=929"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=929"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=929"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}