{"id":1964,"date":"2026-10-03T15:08:20","date_gmt":"2026-10-03T15:08:20","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=1964"},"modified":"2026-10-03T15:08:35","modified_gmt":"2026-10-03T15:08:35","slug":"ip66-stainless-steel-wall-mount-enclosure","status":"publish","type":"product","link":"https:\/\/yocl.com\/ru\/product\/ip66-stainless-steel-wall-mount-enclosure\/","title":{"rendered":"IP66 Stainless Steel Wall-Mount Enclosure"},"content":{"rendered":"<h2>\u041e\u0431\u0437\u043e\u0440<\/h2>\n<p>The <strong>YOCL Electric IP66 Stainless Steel Wall-Mount Enclosure<\/strong> provides a housing for electrical, control and automation components in industrial and commercial installations. The enclosure body and front door are available in <strong>AISI 304 or AISI 316 stainless steel<\/strong>.<\/p>\n<p>Each enclosure includes a <strong>galvanized steel mounting plate<\/strong>, a <strong>polyurethane door seal<\/strong> and a <strong>bar-lock door closure<\/strong>. The 33 standard models cover listed heights of 250\u20131200 mm, widths of 200\u2013800 mm and depths of 150\u2013300 mm. The table below identifies the available dimension combinations and the number of locks for each model.<\/p>\n<h2>\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h2>\n<ul>\n<li><strong>IP66 protection:<\/strong> specified for correctly assembled and installed enclosures with the front door properly closed.<\/li>\n<li><strong>Two stainless steel options:<\/strong> select AISI 304 or AISI 316 for the enclosure body and front door.<\/li>\n<li><strong>Internal mounting plate:<\/strong> galvanized steel provides a surface for mounting compatible electrical and control components.<\/li>\n<li><strong>Polyurethane door seal:<\/strong> supports sealing between the body and front door.<\/li>\n<li><strong>Bar-lock closure:<\/strong> one, two or three bar locks are supplied according to the model.<\/li>\n<li><strong>Wall-mount construction:<\/strong> choose a listed size to suit the installation space and component layout.<\/li>\n<\/ul>\n<h2>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h2>\n<table>\n<thead>\n<tr>\n<th>Specification<\/th>\n<th>Details<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Brand<\/td>\n<td>YOCL \u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Stainless steel electrical enclosure<\/td>\n<\/tr>\n<tr>\n<td>Mounting type<\/td>\n<td>Wall mount<\/td>\n<\/tr>\n<tr>\n<td>Degree of protection<\/td>\n<td>IP66<\/td>\n<\/tr>\n<tr>\n<td>Body and front door material<\/td>\n<td>AISI 304 or AISI 316 stainless steel<\/td>\n<\/tr>\n<tr>\n<td>Internal mounting plate<\/td>\n<td>Galvanized steel<\/td>\n<\/tr>\n<tr>\n<td>Door seal<\/td>\n<td>Polyurethane<\/td>\n<\/tr>\n<tr>\n<td>Door closure<\/td>\n<td>Bar lock<\/td>\n<\/tr>\n<tr>\n<td>Bar locks per enclosure<\/td>\n<td>1, 2 or 3; see the model table<\/td>\n<\/tr>\n<tr>\n<td>Standard models<\/td>\n<td>33<\/td>\n<\/tr>\n<tr>\n<td>Listed height range<\/td>\n<td>250\u20131200 mm<\/td>\n<\/tr>\n<tr>\n<td>Listed width range<\/td>\n<td>200\u2013800 mm<\/td>\n<\/tr>\n<tr>\n<td>Listed depth range<\/td>\n<td>150\u2013300 mm<\/td>\n<\/tr>\n<tr>\n<td>Dimension format<\/td>\n<td>Height \u00d7 width \u00d7 depth (H \u00d7 W \u00d7 D), mm<\/td>\n<\/tr>\n<tr>\n<td>Standard configuration<\/td>\n<td>Enclosure body and front door, mounting plate, bar-lock closure and polyurethane door seal<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Model and Size Table<\/h3>\n<p>All dimensions are in <strong>millimeters<\/strong>, in the order <strong>height (H), width (W), depth (D)<\/strong>.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u041c\u043e\u0434\u0435\u043b\u044c<\/th>\n<th>Height H (mm)<\/th>\n<th>Width W (mm)<\/th>\n<th>Depth D (mm)<\/th>\n<th>Bar locks<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SME252015<\/td>\n<td>250<\/td>\n<td>200<\/td>\n<td>150<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>SME302015<\/td>\n<td>300<\/td>\n<td>200<\/td>\n<td>150<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>SME302515<\/td>\n<td>300<\/td>\n<td>250<\/td>\n<td>150<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>SME302520<\/td>\n<td>300<\/td>\n<td>250<\/td>\n<td>200<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>SME303020<\/td>\n<td>300<\/td>\n<td>300<\/td>\n<td>200<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>SME303030<\/td>\n<td>300<\/td>\n<td>300<\/td>\n<td>300<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>SME403015<\/td>\n<td>400<\/td>\n<td>300<\/td>\n<td>150<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>SME403020<\/td>\n<td>400<\/td>\n<td>300<\/td>\n<td>200<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>SME404015<\/td>\n<td>400<\/td>\n<td>400<\/td>\n<td>150<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>SME404020<\/td>\n<td>400<\/td>\n<td>400<\/td>\n<td>200<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>SME503020<\/td>\n<td>500<\/td>\n<td>300<\/td>\n<td>200<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>SME504015<\/td>\n<td>500<\/td>\n<td>400<\/td>\n<td>150<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>SME504020<\/td>\n<td>500<\/td>\n<td>400<\/td>\n<td>200<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>SME505020<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<td>200<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME604020<\/td>\n<td>600<\/td>\n<td>400<\/td>\n<td>200<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME605020<\/td>\n<td>600<\/td>\n<td>500<\/td>\n<td>200<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME605025<\/td>\n<td>600<\/td>\n<td>500<\/td>\n<td>250<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME606020<\/td>\n<td>600<\/td>\n<td>600<\/td>\n<td>200<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME606025<\/td>\n<td>600<\/td>\n<td>600<\/td>\n<td>250<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME606030<\/td>\n<td>600<\/td>\n<td>600<\/td>\n<td>300<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME705020<\/td>\n<td>700<\/td>\n<td>500<\/td>\n<td>200<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME705025<\/td>\n<td>700<\/td>\n<td>500<\/td>\n<td>250<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME806020<\/td>\n<td>800<\/td>\n<td>600<\/td>\n<td>200<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME806025<\/td>\n<td>800<\/td>\n<td>600<\/td>\n<td>250<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME806030<\/td>\n<td>800<\/td>\n<td>600<\/td>\n<td>300<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME1006025<\/td>\n<td>1000<\/td>\n<td>600<\/td>\n<td>250<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME1006030<\/td>\n<td>1000<\/td>\n<td>600<\/td>\n<td>300<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME1008020<\/td>\n<td>1000<\/td>\n<td>800<\/td>\n<td>200<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME1008025<\/td>\n<td>1000<\/td>\n<td>800<\/td>\n<td>250<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME1008030<\/td>\n<td>1000<\/td>\n<td>800<\/td>\n<td>300<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>SME1206025<\/td>\n<td>1200<\/td>\n<td>600<\/td>\n<td>250<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>SME1206030<\/td>\n<td>1200<\/td>\n<td>600<\/td>\n<td>300<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>SME1208025<\/td>\n<td>1200<\/td>\n<td>800<\/td>\n<td>250<\/td>\n<td>3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The dimension ranges summarize these listed models. Select an exact configuration from the table: for example, <strong>SME1206030<\/strong> is 1200 \u00d7 600 \u00d7 300 mm with three bar locks, while <strong>SME1208025<\/strong> is 1200 \u00d7 800 \u00d7 250 mm with three bar locks.<\/p>\n<h2>Materials and Standard Configuration<\/h2>\n<h3>Stainless Steel Body and Front Door<\/h3>\n<p>Choose <strong>AISI 304 or AISI 316 stainless steel<\/strong> according to the installation environment and project material specification. Specify the selected grade for both the enclosure body and front door when ordering.<\/p>\n<h3>Galvanized Steel Mounting Plate<\/h3>\n<p>The supplied mounting plate provides an internal surface for compatible components such as terminal blocks, relays, contactors, power supplies and automation equipment. Component layout, wiring space and equipment mounting requirements should be checked for the selected enclosure.<\/p>\n<h3>Door Seal and Closure<\/h3>\n<p>The polyurethane seal sits between the enclosure body and front door. Close the door securely using all bar locks supplied for the selected model. Lock quantity is model-specific and is shown alongside each size in the table.<\/p>\n<h2>\u0420\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u0432\u044b\u0431\u043e\u0440\u0443<\/h2>\n<ol>\n<li><strong>Plan the component layout.<\/strong> Allow space for the components, wiring and access required by the installation.<\/li>\n<li><strong>Select a listed model.<\/strong> Compare its H \u00d7 W \u00d7 D dimensions with the available wall space and required enclosure depth.<\/li>\n<li><strong>Specify the stainless steel grade.<\/strong> Choose AISI 304 or AISI 316 to match the project requirements.<\/li>\n<li><strong>Check the closure configuration.<\/strong> Confirm the model&#8217;s one-, two- or three-lock arrangement in the table.<\/li>\n<\/ol>\n<p>Confirm usable internal space and component clearances for the chosen model before finalizing the equipment layout.<\/p>\n<h2>\u041f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0435<\/h2>\n<ul>\n<li>Electrical control panels and automation systems<\/li>\n<li>Machinery electrical equipment<\/li>\n<li>Process control and instrumentation<\/li>\n<li>Terminal and junction equipment<\/li>\n<li>Power distribution and commercial electrical installations<\/li>\n<\/ul>\n<p>Select the enclosure and enclosed equipment according to the project&#8217;s installation requirements.<\/p>\n<h2>\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u0434\u043b\u044f \u0437\u0430\u043a\u0430\u0437\u0430<\/h2>\n<p>Provide the <strong>SME model number<\/strong>, the required <strong>AISI 304 or AISI 316 stainless steel grade<\/strong>, and the <strong>H \u00d7 W \u00d7 D dimensions<\/strong> when requesting a quotation from <strong>YOCL \u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439<\/strong>. The model determines the standard size and bar-lock quantity; the standard configuration includes the mounting plate and polyurethane door seal.<\/p>\n<p>For bulk quantities or additional project requirements, contact YOCL Electric with the intended component layout and installation details.<\/p>","protected":false},"excerpt":{"rendered":"<p>The YOCL Electric IP66 stainless steel wall-mount enclosure houses electrical, control and automation components. Its body and front door are available in AISI 304 or AISI 316 stainless steel, with a galvanized steel mounting plate, polyurethane door seal and bar-lock closure. Choose from 33 standard models with dimensions specified as H \u00d7 W \u00d7 D in millimeters.<\/p>\n<ul>\n<li>IP66 degree of protection<\/li>\n<li>AISI 304 or AISI 316 stainless steel body and door<\/li>\n<li>Galvanized steel mounting plate and polyurethane door seal<\/li>\n<li>33 standard models with one, two or three bar locks<\/li>\n<\/ul>","protected":false},"featured_media":1963,"template":"","meta":[],"product_brand":[],"product_cat":[50],"product_tag":[],"class_list":["post-1964","product","type-product","status-publish","has-post-thumbnail","product_cat-waterproof-enclosures","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/product\/1964","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/media\/1963"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/media?parent=1964"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/product_brand?post=1964"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/product_cat?post=1964"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/product_tag?post=1964"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}