{"id":1984,"date":"2026-10-03T18:14:11","date_gmt":"2026-10-03T18:14:11","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=1984"},"modified":"2026-10-03T18:14:36","modified_gmt":"2026-10-03T18:14:36","slug":"utj5-high-current-din-rail-distribution-terminal-blocks","status":"publish","type":"product","link":"https:\/\/yocl.com\/ru\/product\/utj5-high-current-din-rail-distribution-terminal-blocks\/","title":{"rendered":"UTJ5 \u0431\u043b\u043e\u043a\u0438 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u043d\u0430 DIN-\u0440\u0435\u0439\u043a\u0443 \u0441\u0435\u0440\u0438\u0438 DIN \u0434\u043b\u044f \u0431\u043e\u043b\u044c\u0448\u0438\u0445 \u0442\u043e\u043a\u043e\u0432"},"content":{"rendered":"<h2>\u041e\u0431\u0437\u043e\u0440<\/h2>\n<p>YOCL ELECTRIC UTJ5 Series High-Current DIN Rail Distribution Terminal Blocks provide conductor connection and power distribution in electrical panels, distribution cabinets and industrial control equipment. An aluminum conductive body carries the connection, while a Nylon PA66 housing provides insulation. Internal hex socket screws secure the conductors.<\/p>\n<p>The series includes ten models with individual current ratings from 63 A to 380 A and a rated voltage of 800 V. Six models provide a 1-in\/1-out connection. UTJ5-35-2, UTJ5-50-2 and UTJ5-95-2 provide 1-in\/3-out arrangements, while UTJ5-50-3 provides 1-in\/5-out distribution.<\/p>\n<h2>\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h2>\n<ul>\n<li><strong>Aluminum conductive body:<\/strong> Provides the conductive component for the terminal connection.<\/li>\n<li><strong>Nylon PA66 insulation:<\/strong> Insulates the terminal body.<\/li>\n<li><strong>Hex socket screw connection:<\/strong> Uses internal hex socket screws to retain the conductors.<\/li>\n<li><strong>Model-specific current ratings:<\/strong> Six rating groups cover 63 A, 120 A, 145 A, 220 A, 240 A and 380 A.<\/li>\n<li><strong>800 V rated voltage:<\/strong> Applies to all ten listed models.<\/li>\n<li><strong>Three connection configurations:<\/strong> Select direct connections or models with three or five outputs.<\/li>\n<li><strong>DIN rail mounting:<\/strong> Supports terminal arrangements within electrical panels and control cabinets.<\/li>\n<\/ul>\n<h2>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0411\u0440\u0435\u043d\u0434<\/td>\n<td>YOCL \u042d\u041b\u0415\u041a\u0422\u0420\u0418\u041a<\/td>\n<\/tr>\n<tr>\n<td>\u0421\u0435\u0440\u0438\u044f<\/td>\n<td>UTJ5<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u0438\u043f \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u0430<\/td>\n<td>High-current DIN rail distribution terminal block<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u0435\u0442\u043e\u0434 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f<\/td>\n<td>Internal hex socket screw<\/td>\n<\/tr>\n<tr>\n<td>Mounting<\/td>\n<td>DIN rail<\/td>\n<\/tr>\n<tr>\n<td>Rated voltage<\/td>\n<td>800 V<\/td>\n<\/tr>\n<tr>\n<td>Rated current<\/td>\n<td>63\u2013380 A, depending on model<\/td>\n<\/tr>\n<tr>\n<td>Conductive body material<\/td>\n<td>Aluminum<\/td>\n<\/tr>\n<tr>\n<td>Insulating material<\/td>\n<td>Nylon PA66<\/td>\n<\/tr>\n<tr>\n<td>Screw sizes<\/td>\n<td>M6, M8, M10, M14, M18 and M20, depending on model<\/td>\n<\/tr>\n<tr>\n<td>Connection configurations<\/td>\n<td>1 input \/ 1 output; 1 input \/ 3 outputs; 1 input \/ 5 outputs<\/td>\n<\/tr>\n<tr>\n<td>Colours shown<\/td>\n<td>Yellow-green, grey and blue; specify the colour with the selected model<\/td>\n<\/tr>\n<tr>\n<td>Listed models<\/td>\n<td>10<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Model Specifications<\/h3>\n<table>\n<thead>\n<tr>\n<th>\u041c\u043e\u0434\u0435\u043b\u044c<\/th>\n<th>Rated current<\/th>\n<th>Rated voltage<\/th>\n<th>Dimensions (mm)<\/th>\n<th>Listed conductor section<\/th>\n<th>Screw<\/th>\n<th>Connection configuration<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>UTJ5-16<\/td>\n<td>63 A<\/td>\n<td>800 V<\/td>\n<td>14 \u00d7 44 \u00d7 40 mm<\/td>\n<td>16 mm\u00b2<\/td>\n<td>M6<\/td>\n<td>1 input \/ 1 output<\/td>\n<\/tr>\n<tr>\n<td>UTJ5-35<\/td>\n<td>120 A<\/td>\n<td>800 V<\/td>\n<td>15.8 \u00d7 46 \u00d7 40 mm<\/td>\n<td>35 mm\u00b2<\/td>\n<td>M8<\/td>\n<td>1 input \/ 1 output<\/td>\n<\/tr>\n<tr>\n<td>UTJ5-35-2<\/td>\n<td>120 A<\/td>\n<td>800 V<\/td>\n<td>27.8 \u00d7 46 \u00d7 40 mm<\/td>\n<td>2 \u00d7 35 mm\u00b2<\/td>\n<td>M6<\/td>\n<td>1 input \/ 3 outputs<\/td>\n<\/tr>\n<tr>\n<td>UTJ5-50<\/td>\n<td>145 A<\/td>\n<td>800 V<\/td>\n<td>17.8 \u00d7 50 \u00d7 43.3 mm<\/td>\n<td>50 mm\u00b2<\/td>\n<td>M10<\/td>\n<td>1 input \/ 1 output<\/td>\n<\/tr>\n<tr>\n<td>UTJ5-50-2<\/td>\n<td>145 A<\/td>\n<td>800 V<\/td>\n<td>31.8 \u00d7 50 \u00d7 43.3 mm<\/td>\n<td>2 \u00d7 50 mm\u00b2<\/td>\n<td>M10<\/td>\n<td>1 input \/ 3 outputs<\/td>\n<\/tr>\n<tr>\n<td>UTJ5-50-3<\/td>\n<td>145 A<\/td>\n<td>800 V<\/td>\n<td>44.8 \u00d7 50 \u00d7 43.3 mm<\/td>\n<td>3 \u00d7 50 mm\u00b2<\/td>\n<td>M10<\/td>\n<td>1 input \/ 5 outputs<\/td>\n<\/tr>\n<tr>\n<td>UTJ5-95<\/td>\n<td>220 A<\/td>\n<td>800 V<\/td>\n<td>24 \u00d7 91.4 \u00d7 49.2 mm<\/td>\n<td>95 mm\u00b2<\/td>\n<td>M14<\/td>\n<td>1 input \/ 1 output<\/td>\n<\/tr>\n<tr>\n<td>UTJ5-95-2<\/td>\n<td>220 A<\/td>\n<td>800 V<\/td>\n<td>42 \u00d7 91.4 \u00d7 49.2 mm<\/td>\n<td>2 \u00d7 95 mm\u00b2<\/td>\n<td>M14<\/td>\n<td>1 input \/ 3 outputs<\/td>\n<\/tr>\n<tr>\n<td>UTJ5-150<\/td>\n<td>240 A<\/td>\n<td>800 V<\/td>\n<td>28.8 \u00d7 101.6 \u00d7 60 mm<\/td>\n<td>150 mm\u00b2<\/td>\n<td>M18<\/td>\n<td>1 input \/ 1 output<\/td>\n<\/tr>\n<tr>\n<td>UTJ5-240<\/td>\n<td>380 A<\/td>\n<td>800 V<\/td>\n<td>36 \u00d7 130.7 \u00d7 66.7 mm<\/td>\n<td>240 mm\u00b2<\/td>\n<td>M20<\/td>\n<td>1 input \/ 1 output<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The conductor-section column gives individual model entries; it does not specify a minimum-to-maximum conductor acceptance range or separate input\/output capacities. Confirm the required conductor size for each connection position when ordering. Current ratings apply to the listed models; the 380 A rating applies to UTJ5-240.<\/p>\n<h2>\u0420\u0430\u0437\u043c\u0435\u0440\u044b<\/h2>\n<p>Dimensions are provided in the model table above, in millimetres. Use the individual model dimensions when assessing available installation space.<\/p>\n<h2>Connection Configurations<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u041a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u044f<\/th>\n<th>\u041c\u043e\u0434\u0435\u043b\u0438<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1 input \/ 1 output<\/td>\n<td>UTJ5-16, UTJ5-35, UTJ5-50, UTJ5-95, UTJ5-150 and UTJ5-240<\/td>\n<\/tr>\n<tr>\n<td>1 input \/ 3 outputs<\/td>\n<td>UTJ5-35-2, UTJ5-50-2 and UTJ5-95-2<\/td>\n<\/tr>\n<tr>\n<td>1 input \/ 5 outputs<\/td>\n<td>UTJ5-50-3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The 1-in\/1-out models connect incoming and outgoing conductors directly. Multi-output models provide additional outgoing connection positions for branch distribution.<\/p>\n<h2>Model Selection<\/h2>\n<p>Select the model according to its own current rating, voltage rating, listed conductor section and connection configuration. Check its dimensions against the space available in the panel.<\/p>\n<p>Screw sizes vary by model. UTJ5-35 uses M8 screws, while UTJ5-35-2 uses M6 screws; use the screw size shown for the selected model.<\/p>\n<p>Colour identifiers are <strong>PE: yellow-green<\/strong>, <strong>GY: grey<\/strong> and <strong>BE: blue<\/strong>. Specify the required colour when ordering and confirm availability for the selected model.<\/p>\n<h2>\u041f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0435<\/h2>\n<ul>\n<li>Electrical distribution cabinets and power distribution assemblies.<\/li>\n<li>Industrial control panels and automation equipment.<\/li>\n<li>Machinery electrical systems.<\/li>\n<li>Direct conductor connections and main-to-branch distribution arrangements.<\/li>\n<\/ul>\n<h2>\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u0434\u043b\u044f \u0437\u0430\u043a\u0430\u0437\u0430<\/h2>\n<p>Specify <strong>YOCL \u042d\u041b\u0415\u041a\u0422\u0420\u0418\u041a<\/strong>, the <strong>UTJ5 model<\/strong>, circuit current and voltage requirements, conductor size for each connection position, required input\/output configuration, colour and quantity.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC UTJ5 Series High-Current DIN Rail Distribution Terminal Blocks provide conductor connections and branch distribution in electrical panels and control cabinets.<\/p>\n<ul>\n<li><strong>10 models<\/strong> with individual current ratings from <strong>63 A to 380 A<\/strong>, all rated <strong>800 V<\/strong>.<\/li>\n<li><strong>Aluminum conductive body<\/strong> with <strong>Nylon PA66 insulation<\/strong>.<\/li>\n<li><strong>Internal hex socket screw connections<\/strong>, using model-specific M6\u2013M20 screws.<\/li>\n<li><strong>1-in\/1-out, 1-in\/3-out and 1-in\/5-out<\/strong> configurations.<\/li>\n<li>Listed conductor sections from <strong>16 mm\u00b2 to 240 mm\u00b2<\/strong>, with separate section entries for multi-output models.<\/li>\n<\/ul>","protected":false},"featured_media":1983,"template":"","meta":[],"product_brand":[],"product_cat":[29],"product_tag":[],"class_list":["post-1984","product","type-product","status-publish","has-post-thumbnail","product_cat-modular-distribution-blocks","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/product\/1984","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/media\/1983"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/media?parent=1984"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/product_brand?post=1984"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/product_cat?post=1984"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/ru\/wp-json\/wp\/v2\/product_tag?post=1984"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}