MDD/MDVD Pre-Insulated Male Terminals

YOCL ELECTRIC MDD/MDVD Pre-Insulated Male Terminals are brass tab connectors with PVC insulating sleeves. The combined series pairs MDD single-crimp and MDVD double-crimp models across 0.5–6 mm² conductor groups.

  • Select from 14 matched pairs using NEMA tab width and thickness.
  • Compare B, D, d, E, L1 and L2 dimensions by model and group.
  • Group-specific maximum currents are 10 A, 15 A and 24 A as shown below.
Bu ürün hakkında bilgi alın

Genel Bakış

YOCL ELECTRIC MDD/MDVD Pre-Insulated Male Terminals are brass male tab terminals with PVC insulating sleeves. MDD is the single-crimp construction and MDVD the double-crimp construction with an additional copper tube and sleeve described in the supplied catalog. The page lists 14 matched model pairs in conductor groups from 0.5 to 6 mm².

Özellikler

  • Male tab connection: NEMA tab dimensions are specified by model for mating-part selection.
  • Two crimp constructions: MDD and MDVD share tab and body dimensions by paired row, while overall length differs between L1 and L2.
  • Brass and PVC construction: brass terminal material and PVC insulation are stated for all three conductor groups.
  • Group-specific specifications: conductor range, Imax and the shared E, D and d dimensions are listed by group.

Teknik Özellikler

Parametre Teknik Özellikler
Ürün tipi Pre-insulated male terminal
Seri MDD single crimp; MDVD double crimp
Listed models 14 MDD and 14 MDVD
Terminal material Brass
Insulation PVC
MDVD construction Copper tube with sleeve, described as double pressure in the source
Drawing dimension units mm

Imax is the source’s maximum-current label. Each figure belongs to its conductor group; no test or installation conditions are given.

Model group Color Conductor range AWG Imax E (mm) D (mm) d (mm)
MDD/MDVD 1.25 Red 0.5–1.5 mm² AWG 22–16 10 A 10.0 1.7 3.8
MDD/MDVD 2 Blue 1.5–2.5 mm² AWG 16–14 15 A 10.0 2.3 4.3
MDD/MDVD 5.5 Yellow 4–6 mm² AWG 12–10 24 A 12.5 3.4 5.7

Boyut

The NEMA tab column gives thickness × width. The separate material-thickness column repeats the tab thickness for each row. L1 is the MDD single-crimp overall length; L2 is the MDVD double-crimp overall length. All values are in millimeters.

MDD single-crimp model MDVD double-crimp model Color NEMA tab (mm) Material thickness (mm) B (mm) L1, MDD (mm) L2, MDVD (mm)
MDD 1.25-110(5) MDVD 1.25-110(5) Red 0.5 × 2.8 0.5 2.8 17.7 18.2
MDD 1.25-110(8) MDVD 1.25-110(8) Red 0.8 × 2.8 0.8 2.8 17.7 18.2
MDD 1.25-187(5) MDVD 1.25-187(5) Red 0.5 × 4.75 0.5 4.75 20.0 20.5
MDD 1.25-187(8) MDVD 1.25-187(8) Red 0.8 × 4.75 0.8 4.75 20.0 20.5
MDD 1.25-250 MDVD 1.25-250 Red 0.8 × 6.35 0.8 6.35 21.0 21.5
MDD 2-110(5) MDVD 2-110(5) Blue 0.5 × 2.8 0.5 2.8 17.7 18.2
MDD 2-110(8) MDVD 2-110(8) Blue 0.8 × 2.8 0.8 2.8 17.7 18.2
MDD 2-187(5) MDVD 2-187(5) Blue 0.5 × 4.75 0.5 4.75 20.0 20.5
MDD 2-187(8) MDVD 2-187(8) Blue 0.8 × 4.75 0.8 4.75 20.0 20.5
MDD 2-250 MDVD 2-250 Blue 0.8 × 6.35 0.8 6.35 21.0 21.5
MDD 5.5-110(5) MDVD 5.5-110(5) Yellow 0.5 × 2.8 0.5 2.8 20.0 20.5
MDD 5.5-110(8) MDVD 5.5-110(8) Yellow 0.8 × 2.8 0.8 2.8 20.0 20.5
MDD 5.5-187 MDVD 5.5-187 Yellow 0.5 × 4.75 0.5 4.75 22.0 22.5
MDD 5.5-250 MDVD 5.5-250 Yellow 0.8 × 6.35 0.8 6.35 23.0 23.5

E, D and d for each row are shown by model group in the technical specification table above.

MDD/MDVD Pre-Insulated Male Terminals dimension drawing

Seçim Kılavuzu

Choose the MDD or MDVD construction and conductor group first. Then match NEMA tab width and thickness to the mating connector. Check B, E, D, d and the relevant L1 or L2 length against the available connection space. Specify the exact model code when ordering.

Sipariş Bilgileri

Provide the MDD or MDVD model and quantity when requesting a quotation.

Proje detayları

* ile işaretlenmiş alanlar zorunludur.

Sorunuza yanıt vermek için bilgileriniz kullanılacaktır. Gizlilik bildirimi