YOCL

EN Yalıtımsız Kablo Ucu Yüksükleri

YOCL ELECTRIC EN Non-Insulated Cord End Ferrules are tubular wire ferrules with a flared entry. The 68 listed models cover conductor sections from 0.2 to 185 mm², with several tube lengths for each size.

  • Uninsulated tubular design with a flared wire entry.
  • Model-specific L, D, C and W dimensions.
  • Select by conductor section, AWG designation and tube length.
Bu ürün hakkında bilgi alın

Genel Bakış

YOCL ELECTRIC EN Non-Insulated Cord End Ferrules are tubular wire ferrules for terminating conductors. A flared entry is shown in the dimension drawing. The EN series covers 0.2–185 mm² across 68 listed models, with different lengths for each conductor section.

Özellikler

  • Uninsulated tube: a bare cord end ferrule without an insulating collar.
  • Flared entry: the mouth width W is specified separately from the tube diameter D.
  • Multiple lengths: select the L dimension required for the connection.

Teknik Özellikler

Parametre Teknik Özellikler
Seri EN
Ürün tipi Non-insulated cord end ferrule
Yalıtım None
Conductor sections 0.2–185 mm² across the series
Listed models 68

Boyut

All dimensions are in millimeters. L is overall length; D and C are the outside and inside tube diameters shown in the drawing; W is the flared entry width.

Model Lead section (mm²) AWG L (mm) D (mm) C (mm) W (mm)
EN0206 0.2 #26 6.0 1.1 0.8 1.4
EN0207 0.2 #26 7.0 1.1 0.8 1.4
EN0208 0.2 #26 8.0 1.1 0.8 1.4
EN0306 0.3 #24 6.0 1.3 1.0 1.5
EN0308 0.3 #24 8.0 1.3 1.0 1.5
EN0505 0.5 #22 5.0 1.3 1.0 1.7
EN0506 0.5 #22 6.0 1.3 1.0 1.7
EN0508 0.5 #22 8.0 1.3 1.0 1.7
EN0510 0.5 #22 10.0 1.3 1.0 1.7
EN0512 0.5 #22 12.0 1.3 1.0 1.7
EN7506 0.75 #20 6.0 1.5 1.2 1.9
EN7508 0.75 #20 8.0 1.5 1.2 1.9
EN7510 0.75 #20 10.0 1.5 1.2 1.9
EN7512 0.75 #20 12.0 1.5 1.2 1.9
EN1006 1.0 #18 6.0 1.8 1.5 2.2
EN1008 1.0 #18 8.0 1.8 1.5 2.2
EN1010 1.0 #18 10.0 1.8 1.5 2.2
EN1012 1.0 #18 12.0 1.8 1.5 2.2
EN1507 1.5 #16 7.0 2.0 1.7 2.5
EN1508 1.5 #16 8.0 2.0 1.7 2.5
EN1510 1.5 #16 10.0 2.0 1.7 2.5
EN1512 1.5 #16 12.0 2.0 1.7 2.5
EN1518 1.5 #16 18.0 2.0 1.7 2.5
EN2507 2.5 #14 7.0 2.6 2.3 3.3
EN2508 2.5 #14 8.0 2.6 2.3 3.3
EN2510 2.5 #14 10.0 2.6 2.3 3.3
EN2512 2.5 #14 12.0 2.6 2.3 3.3
EN2518 2.5 #14 18.0 2.6 2.3 3.3
EN4009 4.0 #12 9.0 3.2 2.8 3.9
EN4012 4.0 #12 12.0 3.2 2.8 3.9
EN4018 4.0 #12 18.0 3.2 2.8 3.9
EN6010 6.0 #10 10.0 3.9 3.5 4.8
EN6012 6.0 #10 12.0 3.9 3.5 4.8
EN6015 6.0 #10 15.0 3.9 3.5 4.8
EN6018 6.0 #10 18.0 3.9 3.5 4.8
EN10-12 10.0 #7 12.0 4.9 4.5 5.8
EN10-15 10.0 #7 15.0 4.9 4.5 5.8
EN10-18 10.0 #7 18.0 4.9 4.5 5.8
EN16-12 16.0 #5 12.0 6.2 5.8 7.2
EN16-15 16.0 #5 15.0 6.2 5.8 7.2
EN16-18 16.0 #5 18.0 6.2 5.8 7.2
EN25-16 25.0 #4 16.0 7.9 7.5 9.1
EN25-22 25.0 #4 22.0 7.9 7.5 9.1
EN35-16 35.0 #2 16.0 8.7 8.3 10.2
EN35-25 35.0 #2 25.0 8.7 8.3 10.2
EN50-20 50.0 #1 20.0 10.9 10.3 12.4
EN50-25 50.0 #1 25.0 10.9 10.3 12.4
EN50-30 50.0 1/0 30.0 10.9 10.3 12.7
EN50-32 50.0 1/0 32.0 10.9 10.3 12.7
EN70-22 70.0 2/0 22.0 14.3 13.5 15.8
EN70-25 70.0 2/0 25.0 14.3 13.5 15.8
EN70-30 70.0 2/0 30.0 14.3 13.5 15.8
EN70-32 70.0 2/0 32.0 14.3 13.5 15.8
EN95-25 95.0 3/0 25.0 15.3 14.5 17.3
EN95-30 95.0 3/0 30.0 15.3 14.5 17.3
EN95-32 95.0 3/0 32.0 15.3 14.5 17.3
EN95-34 95.0 3/0 34.0 15.3 14.5 17.3
EN120-30 120.0 4/0 30.0 17.5 16.5 20.2
EN120-32 120.0 4/0 32.0 17.5 16.5 20.2
EN120-34 120.0 4/0 34.0 17.5 16.5 20.2
EN120-38 120.0 4/0 38.0 17.5 16.5 20.2
EN120-40 120.0 4/0 40.0 17.5 16.5 20.2
EN150-32 150.0 250/300 32.0 20.6 19.6 23.0
EN150-34 150.0 250/300 34.0 20.6 19.6 23.0
EN150-38 150.0 250/300 38.0 20.6 19.6 23.0
EN150-40 150.0 250/300 40.0 20.6 19.6 23.0
EN185-32 185.0 250/300 32.0 21.4 20.2 23.9
EN185-40 185.0 250/300 40.0 21.4 20.2 23.9

EN Non-Insulated Cord End Ferrules dimension drawing

Seçim Kılavuzu

Select the conductor section and check the listed L, D, C and W dimensions against the intended termination. The 50 mm² entries include two mouth widths and AWG designations; use the complete model number when ordering.

Sipariş Bilgileri

Provide the full EN model and required quantity when requesting a quotation.

Proje detayları

* ile işaretlenmiş alanlar zorunludur.

Sorunuza yanıt vermek için bilgileriniz kullanılacaktır. Gizlilik bildirimi