{"id":2191,"date":"2026-10-05T06:45:28","date_gmt":"2026-10-05T06:45:28","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=d55bd7fa61754df55b17882dd46ef3186cecc598b4dc63244362e387091bcd3e"},"modified":"2026-10-05T06:45:28","modified_gmt":"2026-10-05T06:45:28","slug":"what-is-heat-shrink-tubing","status":"publish","type":"post","link":"https:\/\/yocl.com\/tr\/what-is-heat-shrink-tubing\/","title":{"rendered":"Is\u0131 Daralan Makaron Nedir? Oranlar, Duvarlar ve Yap\u0131\u015fkan Astarlar"},"content":{"rendered":"<p><strong>Is\u0131 ile daralan makaron, geni\u015fletilmi\u015f boyutta tedarik edilen ve \u00fcr\u00fcn\u00fcn belirtilen ko\u015fullar\u0131 alt\u0131nda \u0131s\u0131t\u0131ld\u0131\u011f\u0131nda b\u00fcz\u00fclen bir polimer k\u0131l\u0131ft\u0131r.<\/strong> Elektriksel yal\u0131t\u0131m, tan\u0131mlama veya koruyucu kaplama i\u00e7in telleri, terminalleri ve ba\u011flant\u0131 par\u00e7alar\u0131n\u0131 kaplar. Yap\u0131\u015fkan astarl\u0131 bir s\u0131n\u0131f, malzemeleri ve kurulumu uygulamaya uygun oldu\u011funda yap\u0131\u015fkan bir aray\u00fcz de olu\u015fturabilir.<\/p>\n<p>Is\u0131 ile daralan bir \u00fcr\u00fcn\u00fc anlamak i\u00e7in \u00fc\u00e7 soruyu ay\u0131r\u0131n: <strong>ne kadar geri kazanabilece\u011fi, duvar\u0131n\u0131n nas\u0131l yap\u0131ld\u0131\u011f\u0131 ve yap\u0131\u015fkan i\u00e7erip i\u00e7ermedi\u011fi<\/strong>. Bir 3:1 oran\u0131 \u00e7ap geri kazan\u0131m\u0131n\u0131 tan\u0131mlar. Tek duvar yap\u0131y\u0131 tan\u0131mlar. Yap\u0131\u015fkan astar, i\u00e7 malzemeyi tan\u0131mlar. Bu alanlar\u0131n hi\u00e7biri di\u011fer ikisini sa\u011flamaz.<\/p>\n<h2>Is\u0131 ile daralan makaronun bir elektrik ba\u011flant\u0131s\u0131ndaki yeri<\/h2>\n<p>K\u0131l\u0131f, mevcut bir telin veya ba\u011flant\u0131n\u0131n etraf\u0131na oturur. Amac\u0131 bir terminali kaplamak, a\u00e7\u0131kta kalan iletken bir b\u00f6l\u00fcm\u00fc yal\u0131tmak, bir iletkeni renkle tan\u0131mlamak veya bir y\u00fczeyi korumak olabilir. Bu i\u015flevler hala ekipman i\u00e7in do\u011fru s\u0131n\u0131f\u0131 ve boyutlar\u0131 gerektirir.<\/p>\n<p>Elektrik ba\u011flant\u0131s\u0131 kendisi zaten uygun olmal\u0131d\u0131r. Boru, do\u011fru bir s\u0131kma, uyumlu iletken ba\u011flant\u0131s\u0131 veya yeterli mekanik destek sa\u011flamaz. S\u0131k\u0131 oturan bir k\u0131l\u0131f, ona yap\u0131\u015fmadan bir ba\u011flant\u0131y\u0131 kaplayabilir; k\u0131l\u0131f u\u00e7lar\u0131n\u0131n s\u0131zd\u0131rmazl\u0131\u011f\u0131 ayr\u0131 bir gerekliliktir.<\/p>\n<p>Geri kazan\u0131m\u0131n \u00fc\u00e7 farkl\u0131 durumu vard\u0131r:<\/p>\n<ul>\n<li><strong>Beslenmi\u015f veya geni\u015fletilmi\u015f:<\/strong> k\u0131l\u0131f\u0131n par\u00e7an\u0131n \u00fczerine kaymas\u0131n\u0131 sa\u011flayan daha b\u00fcy\u00fck i\u00e7 \u00e7ap.<\/li>\n<li><strong>Serbest\u00e7e geri kazan\u0131lm\u0131\u015f:<\/strong> i\u00e7erideki bir nesne taraf\u0131ndan durdurulmadan, belirtilen geri kazan\u0131m ko\u015fullar\u0131 alt\u0131nda ula\u015fabilece\u011fi daha k\u00fc\u00e7\u00fck i\u00e7 \u00e7ap.<\/li>\n<li><strong>Tak\u0131lm\u0131\u015f:<\/strong> k\u0131l\u0131f i\u00e7indeki nesneye uyar, bu nedenle ger\u00e7ek \u00e7ap\u0131 ve duvar kal\u0131nl\u0131\u011f\u0131 bu geometriye ba\u011fl\u0131d\u0131r.<\/li>\n<\/ul>\n<p>NASA\u2019n\u0131n <a href=\"https:\/\/standards.nasa.gov\/sites\/default\/files\/standards\/KSC\/F\/KSC-E-165-REV-F.pdf\" target=\"_blank\" rel=\"noopener\">KSC-E-165 Revizyon F, 3.8.1.1.1 b\u00f6l\u00fcm\u00fc<\/a> yer destek ekipman\u0131 imalat\u0131ndaki geni\u015fletilmi\u015f\/geri kazan\u0131lm\u0131\u015f boyut ili\u015fkisini belgeliyor: geni\u015fletilmi\u015f boyut nesneyi temizlerken, geri kazan\u0131lm\u0131\u015f boyut ondan daha k\u00fc\u00e7\u00fckt\u00fcr. Bu, bir boru tesisat\u0131n\u0131n genel onay\u0131ndan ziyade kullan\u0131\u015fl\u0131 bir boyutsal prensiptir.<\/p>\n<h2>2:1, 3:1 ve 4:1 daralma oranlar\u0131 ne anlama geliyor?<\/h2>\n<p>Bu <strong>daralma oran\u0131, geni\u015fletilmi\u015f i\u00e7 \u00e7ap ile serbest\u00e7e geri kazan\u0131lm\u0131\u015f i\u00e7 \u00e7ap\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131r<\/strong>. Bunu nominal bir \u00e7ap ili\u015fkisi olarak okuyun, ard\u0131ndan modelin boyut tablosundaki ger\u00e7ek tedarik edilen ve geri kazan\u0131lm\u0131\u015f limitleri kullan\u0131n.<\/p>\n<p>\u00d6rne\u011fin, Seattle City Light\u2019\u0131n <a href=\"https:\/\/web8.seattle.gov\/city-light-engineering-standards\/Home\/GetPDF?libId=MaterialStandards&amp;searchForfileName=737470.pdf\" target=\"_blank\" rel=\"noopener\">Malzeme Standard\u0131 7374.70<\/a> i\u00e7 \u00e7aplar ve et kal\u0131nl\u0131\u011f\u0131ndan ayr\u0131 olarak bir \u201cgenle\u015fmi\u015f-geri kazan\u0131lm\u0131\u015f\u201d oran belirtir. \u00d6zel kullan\u0131m \u00fcr\u00fcnleri ve kurulum gereksinimleri genel YOCL spesifikasyonlar\u0131 de\u011fildir.<\/p>\n<p>\u0130deal bir <strong>ba\u015flang\u0131\u00e7 deli\u011fi 12 mm i\u00e7in<\/strong>, aritmetik \u015f\u00f6yledir:<\/p>\n<table>\n<thead>\n<tr>\n<th>Nominal oran<\/th>\n<th>\u0130deal serbest geri kazan\u0131lm\u0131\u015f delik<\/th>\n<th>Anlam\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2:1<\/td>\n<td>12 \u00f7 2 = 6 mm<\/td>\n<td>Ba\u015flang\u0131\u00e7 i\u00e7 \u00e7ap\u0131n\u0131n yar\u0131s\u0131<\/td>\n<\/tr>\n<tr>\n<td>3:1<\/td>\n<td>12 \u00f7 3 = 4 mm<\/td>\n<td>Ba\u015flang\u0131\u00e7 i\u00e7 \u00e7ap\u0131n\u0131n \u00fc\u00e7te biri<\/td>\n<\/tr>\n<tr>\n<td>4:1<\/td>\n<td>12 \u00f7 4 = 3 mm<\/td>\n<td>Ba\u015flang\u0131\u00e7 i\u00e7 \u00e7ap\u0131n\u0131n d\u00f6rtte biri<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/what-is-heat-shrink-tubing-ratios.webp\" alt=\"\u00d6l\u00e7eksiz nominal oran \u015femati\u011fi: ideal bir 12 mm geni\u015fletilmi\u015f i\u00e7 \u00e7ap, 6 mm&#039;e serbest\u00e7e geri kazan\u0131r 2&#039;de: 1, 4 mm 3&#039;de: 1 ve 3 mm 4&#039;de: 1.\"><figcaption>Kavramsal \u015fema, \u00f6l\u00e7ekli de\u011fildir. Say\u0131lar, \u00fcr\u00fcn boyutu \u00f6nerisi de\u011fil, nominal serbest geri kazan\u0131m \u00e7ap\u0131 aritmeti\u011fini g\u00f6stermektedir. Tak\u0131l\u0131 boru, i\u00e7indeki nesne taraf\u0131ndan k\u0131s\u0131tlan\u0131r.<\/figcaption><\/figure>\n<p>Bunlar, \u00fcr\u00fcn toleranslar\u0131ndan \u00f6nceki \u00f6rnek de\u011ferlerdir, katalog boyutu \u00f6nerisi de\u011fildir. Serbest geri kazan\u0131m\u0131 tan\u0131mlarlar. K\u0131l\u0131f\u0131n o deli\u011fe ula\u015fmas\u0131n\u0131 engelleyen bir kablo \u00fczerinde, tak\u0131l\u0131 \u00e7ap daha b\u00fcy\u00fck kal\u0131r.<\/p>\n<p>Daha y\u00fcksek bir oran, ayn\u0131 ba\u015flang\u0131\u00e7 deli\u011fi i\u00e7in daha geni\u015f bir nominal \u00e7ap-toparlanma aral\u0131\u011f\u0131 sa\u011flar. Bu nedenle, k\u0131l\u0131f\u0131n ge\u00e7mesi gereken \u00f6zellik ile kavramas\u0131 gereken y\u00fczey aras\u0131ndaki daha b\u00fcy\u00fck bir ge\u00e7i\u015fi sa\u011flamaya yard\u0131mc\u0131 olabilir. Ger\u00e7ek uyum hala modelin boyutlar\u0131na ve uygulama aral\u0131\u011f\u0131na ba\u011fl\u0131d\u0131r.<\/p>\n<p>Oran <strong>belirtmez<\/strong> uzunluk azalmas\u0131n\u0131, duvar say\u0131s\u0131n\u0131 veya elektriksel g\u00f6revi. Kapsama uzunlu\u011fu \u00f6nemliyse, kesilen uzunlu\u011fa \u00e7ap oran\u0131n\u0131 uygulamak yerine \u00fcr\u00fcn\u00fcn beyan edilen boyuna de\u011fi\u015fimi kontrol edin.<\/p>\n<h2>Duvar kal\u0131nl\u0131\u011f\u0131, duvar say\u0131s\u0131 ve yap\u0131\u015ft\u0131r\u0131c\u0131 farkl\u0131 alanlard\u0131r<\/h2>\n<h3>Duvar kal\u0131nl\u0131\u011f\u0131 duvar yap\u0131s\u0131n\u0131 tan\u0131mlar<\/h3>\n<p>\u0130nce duvarl\u0131, orta duvarl\u0131 ve kal\u0131n duvarl\u0131 tan\u0131mlar\u0131, k\u0131l\u0131f\u0131n duvar yap\u0131s\u0131yla ilgilidir. Yay\u0131nlanan kal\u0131nl\u0131\u011f\u0131 ve \u00f6l\u00e7\u00fcm durumunu kar\u015f\u0131la\u015ft\u0131r\u0131n: tedarik edildi\u011fi gibi, serbest\u00e7e toparlanm\u0131\u015f veya tak\u0131lm\u0131\u015f. Toparlanm\u0131\u015f duvar rakam\u0131, her kablo \u00e7ap\u0131nda otomatik olarak bitmi\u015f duvar olarak kullan\u0131lamaz.<\/p>\n<p>Halka a\u00e7\u0131kl\u0131\u011f\u0131 <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/63680\" target=\"_blank\" rel=\"noopener\">IEC 60684-3-214:2019<\/a> ayn\u0131 nominal 3:1 oran\u0131nda orta etli ve kal\u0131n etli poliolefin tiplerini ay\u0131rt eder. Bu, duvar yap\u0131s\u0131 ve oran\u0131n neden ayr\u0131 alanlara ihtiya\u00e7 duydu\u011funu g\u00f6stermektedir; kapsam, her \u00fcr\u00fcn i\u00e7in evrensel bir kal\u0131nl\u0131k s\u0131n\u0131fland\u0131rmas\u0131 olu\u015fturmaz.<\/p>\n<h3>Duvar say\u0131s\u0131 yap\u0131y\u0131 tan\u0131mlar<\/h3>\n<p>Burada tart\u0131\u015f\u0131lan yayg\u0131n elektrik kablolama yap\u0131lar\u0131 i\u00e7in, <strong>tek duvarl\u0131 boru<\/strong> astar i\u00e7ermeyen bir k\u0131l\u0131ft\u0131r. <strong>Yap\u0131\u015fkan astarl\u0131 \u00e7ift duvarl\u0131 boru<\/strong> d\u0131\u015f k\u0131l\u0131f\u0131 yap\u0131\u015f\u0131k s\u0131cakta eriyen i\u00e7 astar ile birle\u015ftirir. Her iki katman tek bir boru \u00fcr\u00fcn\u00fc olu\u015ftursa da, astar ayr\u0131 bir malzeme olarak kal\u0131r.<\/p>\n<p>\u201cTek duvar\u201d her zaman ayn\u0131 ince duvar anlam\u0131na gelmez ve \u201c\u00e7ift duvar\u201d evrensel bir kal\u0131n duvar g\u00f6stergesi de\u011fildir. Duvar yap\u0131s\u0131n\u0131 katman say\u0131s\u0131na g\u00f6re s\u0131ralamak yerine boyutlar\u0131 kontrol edin.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/what-is-heat-shrink-tubing-walls-linings.webp\" alt=\"Daha ince ve daha kal\u0131n duvarlar\u0131 astars\u0131z ve yap\u0131\u015fkan astarl\u0131 yap\u0131lardan ay\u0131ran kavramsal i\u00e7i bo\u015f t\u00fcp b\u00f6l\u00fcmleri, s\u0131cakta eriyen i\u00e7 astar tan\u0131mlanm\u0131\u015f.\"><figcaption>Duvar yap\u0131s\u0131 ve astar ba\u011f\u0131ms\u0131z alanlard\u0131r; \u015fematik kal\u0131nl\u0131klar \u00f6l\u00e7\u00fclen YOCL model boyutlar\u0131n\u0131 temsil etmez.<\/figcaption><\/figure>\n<h3>Yap\u0131\u015ft\u0131r\u0131c\u0131 bir aray\u00fcz fonksiyonu ekler<\/h3>\n<p>Belirtilen \u0131s\u0131tma i\u015flemi s\u0131ras\u0131nda, yap\u0131\u015fkan astar yumu\u015far ve uyumlu e\u015fle\u015fen y\u00fczeylerde akar. Bu, gerekli bir \u00e7evresel s\u0131zd\u0131rmazl\u0131k i\u00e7in yap\u0131\u015ft\u0131r\u0131lm\u0131\u015f bir aray\u00fcz sa\u011flayabilir. Sonu\u00e7, astara, kablo ceketine, temas geometrisine, kuruluma ve maruz kalmaya ba\u011fl\u0131d\u0131r; yaln\u0131zca yap\u0131\u015fkan astarl\u0131 bir a\u00e7\u0131klama su ge\u00e7irmez performans\u0131 kan\u0131tlamaz.<\/p>\n<p><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/2899\" target=\"_blank\" rel=\"noopener\">IEC 60684-3-248:2007<\/a> yap\u0131\u015fkan i\u00e7 duvarlara sahip \u00e7ift duvarl\u0131 poliolefin kaplamay\u0131 nominal 2:1, 3:1 ve 4:1 varyantlar\u0131nda tan\u0131mlar. Resmi kamu kapsam\u0131, bir YOCL modelinin sertifikas\u0131n\u0131 de\u011fil, yap\u0131 ailesini tan\u0131mlar.<\/p>\n<p>YOCL\u2019\u0131n kendi katalo\u011fu ayr\u0131m\u0131 somutla\u015ft\u0131r\u0131yor: <a href=\"https:\/\/yocl.com\/tr\/product\/4-1-zero-halogen-single-wall-heat-shrink-tubing\/\">4:1 Halojen \u0130\u00e7ermeyen tek duvarl\u0131 boru<\/a> dahili yap\u0131\u015ft\u0131r\u0131c\u0131 olmad\u0131\u011f\u0131n\u0131 belirtirken, <a href=\"https:\/\/yocl.com\/tr\/product\/hs3x-3-1-dual-wall-adhesive-lined-heat-shrink-tubing\/\">HS3X 3:1 \u00e7ift cidarl\u0131 boru<\/a> s\u0131cakta eriyen i\u00e7 katman\u0131 belirtir. Bunlar birinci taraf \u00fcr\u00fcn beyanlar\u0131d\u0131r. Daha b\u00fcy\u00fck oran astarl\u0131 \u00fcr\u00fcn\u00fc tan\u0131mlamaz.<\/p>\n<p>\u0130ki yap\u0131 aras\u0131ndaki ger\u00e7ek se\u00e7im i\u00e7in \u015furaya bak\u0131n: <a href=\"https:\/\/yocl.com\/tr\/single-wall-vs-dual-wall-heat-shrink-tubing\/\">Tek Duvarl\u0131 ve \u00c7ift Duvarl\u0131 Is\u0131yla Daralan Makaron Kar\u015f\u0131la\u015ft\u0131rmas\u0131<\/a>, i\u015flevlerini, uygulama ko\u015fullar\u0131n\u0131 ve model verilerini kar\u015f\u0131la\u015ft\u0131r\u0131r.<\/p>\n<h2>Malzeme ve s\u0131cakl\u0131k hala \u00f6nemlidir<\/h2>\n<p>Malzeme adlar\u0131, spesifikasyonun ba\u015fka bir b\u00f6l\u00fcm\u00fcn\u00fc tan\u0131mlar. \u00d6rne\u011fin, polipropilen ve polivinil klor\u00fcr (PVC) kendi ba\u015flar\u0131na size daralma oran\u0131n\u0131, astar yap\u0131s\u0131n\u0131 veya her hizmet \u00f6zelli\u011fini s\u00f6ylemez. NASA'n\u0131n \u0131s\u0131yla daralan alt b\u00f6l\u00fcm\u00fc, hem \u00e7apraz ba\u011fl\u0131 polipropilen hem de \u00e7apraz ba\u011fl\u0131 olmayan PVC \u00f6rneklerini i\u00e7erir, bu nedenle t\u00fcm borulara tek bir \u00fcretim a\u00e7\u0131klamas\u0131 dayat\u0131lmamal\u0131d\u0131r.<\/p>\n<p>Ayr\u0131ca ay\u0131rt edin <strong>toparlanma ko\u015fullar\u0131<\/strong> den <strong>\u00e7al\u0131\u015fma s\u0131cakl\u0131\u011f\u0131<\/strong>. \u0130lk b\u00fcz\u00fclme, tam geri kazan\u0131m ve yap\u0131\u015fkan aktivasyon gereksinimleri kurulum s\u00fcrecini a\u00e7\u0131klar. \u00c7al\u0131\u015fma aral\u0131\u011f\u0131 sonraki hizmeti tan\u0131mlar. Her alan i\u00e7in se\u00e7ilen modelin belgelerini kullan\u0131n; geri kazan\u0131m rakam\u0131, \u0131s\u0131 tabancas\u0131 ayar\u0131 de\u011fildir.<\/p>\n<p>NASA'n\u0131n ayn\u0131 alt b\u00f6l\u00fcm\u00fc, \u0131s\u0131 maruziyetini t\u00fcp boyutuna ve t\u00fcr\u00fcne ba\u011fl\u0131 hale getirir ve kaplanan nesneye zarar vermekten ka\u00e7\u0131nmay\u0131 gerektirir. Kablo k\u0131l\u0131flar\u0131 ve yak\u0131ndaki bile\u015fenler bu nedenle, k\u0131l\u0131f\u0131n kendisiyle birlikte \u00f6nemlidir. Bu merkez terminolojiyi sa\u011flar; ger\u00e7ek s\u00fcre\u00e7 modelin talimatlar\u0131na tabidir.<\/p>\n<p>Elektriksel veya \u00e7evresel \u00f6zellikler i\u00e7in, kesin s\u0131n\u0131f\u0131 ve ilgili kan\u0131tlar\u0131 kullan\u0131n. <a href=\"https:\/\/www.ul.com\/services\/insulating-tubing-testing-and-certification\" target=\"_blank\" rel=\"noopener\">UL \u0130zolasyon t\u00fcp\u00fc k\u0131lavuzu<\/a> kabul edilebilirlik ko\u015fullar\u0131n\u0131n voltaj, s\u0131cakl\u0131k ve iste\u011fe ba\u011fl\u0131 derecelendirmeleri kaydetti\u011fini a\u00e7\u0131klar. Renk, oran veya astar a\u00e7\u0131klamas\u0131 bu kayd\u0131n yerini tutamaz ve burada herhangi bir YOCL sertifikas\u0131 iddia edilmemektedir.<\/p>\n<h2>S\u0131rada hangi bilgiye ihtiyac\u0131n\u0131z var?<\/h2>\n<p>Bir \u00fcr\u00fcn a\u00e7\u0131klamas\u0131n\u0131 ayr\u0131 alanlar k\u00fcmesi olarak okuyun. Her alan farkl\u0131 bir soruyu yan\u0131tlar:<\/p>\n<table>\n<thead>\n<tr>\n<th>Sorunuz<\/th>\n<th>Kontrol edilecek alan veya kaynak<\/th>\n<th>Kendi ba\u015f\u0131na neyi belirleyemez<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>K\u0131l\u0131f par\u00e7an\u0131n \u00fczerinden ge\u00e7ip \u00fczerine geri sar\u0131lacak m\u0131?<\/td>\n<td>Minimum sa\u011flanan delik, maksimum geri kazan\u0131lm\u0131\u015f delik ve izin verilen uygulama aral\u0131\u011f\u0131<\/td>\n<td>S\u0131zd\u0131rmazl\u0131k veya elektriksel uygunluk<\/td>\n<\/tr>\n<tr>\n<td>Ne kadar geri kazan\u0131m mevcut?<\/td>\n<td>Nominal oran, ger\u00e7ek boyut tablosunun yan\u0131nda<\/td>\n<td>Uzunluk de\u011fi\u015fimi, duvar say\u0131s\u0131 veya yap\u0131\u015fkan varl\u0131\u011f\u0131<\/td>\n<\/tr>\n<tr>\n<td>Bitmi\u015f k\u0131l\u0131f ne kadar yer kaplayacak?<\/td>\n<td>Duvar kal\u0131nl\u0131\u011f\u0131, \u00f6l\u00e7\u00fcm durumu ve tak\u0131l\u0131-yap\u0131 bilgisi ile<\/td>\n<td>Yaln\u0131zca serbest iyile\u015fme de\u011ferinden bitmi\u015f d\u0131\u015f \u00e7ap<\/td>\n<\/tr>\n<tr>\n<td>Ba\u011flant\u0131n\u0131n yap\u0131\u015fkan bir aray\u00fcze ihtiyac\u0131 var m\u0131?<\/td>\n<td>Astarl\u0131 olmayan\/yap\u0131\u015fkan astarl\u0131 yap\u0131, astar uyumlulu\u011fu ve s\u0131zd\u0131rmazl\u0131k kan\u0131t\u0131<\/td>\n<td>Yaln\u0131zca \u201c\u00e7ift duvar\u201ddan garanti edilmi\u015f bir nem derecesi<\/td>\n<\/tr>\n<tr>\n<td>Hangi \u0131s\u0131tma ve servis ko\u015fullar\u0131 uygundur?<\/td>\n<td>Model talimatlar\u0131, kurtarma alanlar\u0131 ve \u00e7al\u0131\u015fma aral\u0131\u011f\u0131<\/td>\n<td>Malzeme ad\u0131ndan evrensel bir \u0131s\u0131 ayar\u0131<\/td>\n<\/tr>\n<tr>\n<td>S\u0131n\u0131f, ekipman\u0131n g\u00f6revini kar\u015f\u0131l\u0131yor mu?<\/td>\n<td>Kesin malzeme\/s\u0131n\u0131f dok\u00fcmantasyonu ve ge\u00e7erli sertifika veya test kayd\u0131<\/td>\n<td>Genel bir \u00fcr\u00fcn etiketinden tam ekipman uygunlu\u011fu<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Bu <a href=\"https:\/\/yocl.com\/tr\/heat-shrink-tubing-manufacturer\/\">YOCL \u0131s\u0131yla daralan makaron katalo\u011fu<\/a> Tek duvarl\u0131 ve yap\u0131\u015fkan astarl\u0131 serileri bireysel \u00fcr\u00fcn bilgileriyle d\u00fczenler. \u0130lgili yap\u0131y\u0131 ve oran\u0131 bulmak i\u00e7in kullan\u0131n, ard\u0131ndan kesin modelin boyutlar\u0131n\u0131, talimatlar\u0131n\u0131 ve kan\u0131tlar\u0131n\u0131 kontrol edin. Bir sorgu i\u00e7in, yaln\u0131zca \u201c3:1 \u0131s\u0131yla daralan makaron\u201d istemek yerine, kaplanacak par\u00e7ay\u0131 ve ama\u00e7lanan i\u015flevini a\u00e7\u0131klay\u0131n.<\/p>\n<h2>Referanslar<\/h2>\n<ol>\n<li>NASA Kennedy Uzay Merkezi \u2014 <a href=\"https:\/\/standards.nasa.gov\/sites\/default\/files\/standards\/KSC\/F\/KSC-E-165-REV-F.pdf\" target=\"_blank\" rel=\"noopener\">KSC-E-165 Revizyon F, 2021<\/a>. B\u00f6l\u00fcmler 3.8.1.1 ve 3.8.1.1.1; yer destek ekipman\u0131 kaplamas\u0131, boyutlar\u0131 ve \u0131s\u0131ya maruz kalma gereksinimleri.<\/li>\n<li>Seattle \u015eehir Ayd\u0131nlatma \u2014 <a href=\"https:\/\/web8.seattle.gov\/city-light-engineering-standards\/Home\/GetPDF?libId=MaterialStandards&amp;searchForfileName=737470.pdf\" target=\"_blank\" rel=\"noopener\">Malzeme Standard\u0131 7374.70, 2012: Boru, Is\u0131yla Daralan Tip, Orta Duvar<\/a>. B\u00f6l\u00fcm 3; geni\u015fletilmi\u015f-geri kazan\u0131lm\u0131\u015f oran terminolojisi ve ayr\u0131 boyut alanlar\u0131.<\/li>\n<li>IEC \u2014 <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/63680\" target=\"_blank\" rel=\"noopener\">IEC 60684-3-214:2019: Kal\u0131n ve orta duvarl\u0131 poliolefin kaplama<\/a>. Resmi kamu kapsam\u0131; yayg\u0131n bir nominal oranda duvar kategorileri.<\/li>\n<li>IEC \u2014 <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/2899\" target=\"_blank\" rel=\"noopener\">IEC 60684-3-248:2007: Genel ama\u00e7l\u0131 \u00e7ift duvarl\u0131 poliolefin kaplama<\/a>. Resmi kamu kapsam\u0131; yap\u0131\u015fkanl\u0131 i\u00e7 duvarlar ve nominal 2:1, 3:1 ve 4:1 varyantlar\u0131.<\/li>\n<li>YOCL \u00fcr\u00fcn bilgileri \u2014 <a href=\"https:\/\/yocl.com\/tr\/product\/4-1-zero-halogen-single-wall-heat-shrink-tubing\/\">4:1 Halojensiz Tek Duvarl\u0131 Is\u0131yla Daralan Makaron<\/a>. Beyan edilen oran ve i\u00e7 yap\u0131\u015fkan katman\u0131n\u0131n olmamas\u0131.<\/li>\n<li>YOCL \u00fcr\u00fcn bilgileri \u2014 <a href=\"https:\/\/yocl.com\/tr\/product\/hs3x-3-1-dual-wall-adhesive-lined-heat-shrink-tubing\/\">HS3X 3:1 Yap\u0131\u015fkan Astarl\u0131 \u00c7ift Cidarl\u0131 Is\u0131yla Daralan Makaron<\/a>. Beyan edilen oran ve malzeme katmanlar\u0131.<\/li>\n<li>UL \u00c7\u00f6z\u00fcmleri \u2014 <a href=\"https:\/\/www.ul.com\/services\/insulating-tubing-testing-and-certification\" target=\"_blank\" rel=\"noopener\">\u0130zole Boru Testi ve Sertifikasyonu<\/a>. Kabul edilebilirlik ve iste\u011fe ba\u011fl\u0131 derecelendirmelerin model ko\u015fullar\u0131.<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>Heat shrink tubing is a polymer sleeve supplied in an expanded size that contracts when heated under the product&#8217;s specified conditions. It covers wires, terminals and connection parts for electrical insulation, identification or protective covering. An adhesive-lined grade can also create a bonded interface when its materials and installation suit the application. To understand a [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":2190,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[165],"tags":[],"class_list":["post-2191","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-heat-shrink-insulation"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/2191","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/comments?post=2191"}],"version-history":[{"count":1,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/2191\/revisions"}],"predecessor-version":[{"id":2192,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/2191\/revisions\/2192"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/2190"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=2191"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/categories?post=2191"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/tags?post=2191"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}