{"id":2454,"date":"2026-10-06T12:34:25","date_gmt":"2026-10-06T12:34:25","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=cf559107b82a3d9cf45835dd6dfd355c3fc2ed3843accced2ba6439eaf2784e5"},"modified":"2026-10-06T12:34:25","modified_gmt":"2026-10-06T12:34:25","slug":"heat-shrink-tubing-size-chart","status":"publish","type":"post","link":"https:\/\/yocl.com\/tr\/heat-shrink-tubing-size-chart\/","title":{"rendered":"Is\u0131yla Daralan Makaron Boyut Tablosu: Genle\u015fmi\u015f ve B\u00fcz\u00fclm\u00fc\u015f \u00c7aplar"},"content":{"rendered":"<p><strong>Is\u0131tma \u00f6ncesi geni\u015fletilmi\u015f i\u00e7 \u00e7ap\u0131 ve b\u00fcz\u00fclmeden sonra serbest\u00e7e geri kazan\u0131lm\u0131\u015f i\u00e7 \u00e7ap\u0131 olmak \u00fczere iki i\u00e7 \u00e7apa g\u00f6re bir \u0131s\u0131 b\u00fcz\u00fc\u015fmeli makaron boyut tablosunu okuyun.<\/strong> Sa\u011flanan i\u00e7 \u00e7ap, en b\u00fcy\u00fck \u00f6zelli\u011fi temizlemelidir; geri kazan\u0131lm\u0131\u015f i\u00e7 \u00e7ap, kavramas\u0131 gereken y\u00fczeyden daha k\u00fc\u00e7\u00fck olmal\u0131d\u0131r. Nominal bir boyutu b\u00fcz\u00fclme oran\u0131na b\u00f6lmek yerine, ger\u00e7ek s\u0131ra s\u0131n\u0131rlar\u0131n\u0131 kullan\u0131n.<\/p>\n<p>A\u015fa\u011f\u0131daki tablolar <strong>\u00fc\u00e7 YOCL serisi boyunca 61 boyut giri\u015flerini yeniden \u00fcretir<\/strong>. T\u00fcm boyutlar <strong>milimetre<\/strong>. dir. Bunlar, her \u0131s\u0131 b\u00fcz\u00fc\u015fmeli malzeme i\u00e7in evrensel bir tablo de\u011fil, seriye \u00f6zg\u00fc \u00fcr\u00fcn beyanlar\u0131d\u0131r.<\/p>\n<h2>YOCL \u0131s\u0131 ile daralan makaron boyut tablolar\u0131<\/h2>\n<h3>Yakla\u015f\u0131k 2:1 tek cidarl\u0131 makaron \u2014 HTS<\/h3>\n<p>Bu <a href=\"https:\/\/yocl.com\/tr\/product\/hts-2-1-single-wall-heat-shrink-tubing\/\">YOCL HTS boyut tablosu<\/a> e\u015fle\u015ftirilmi\u015f nominal boyutlar\u0131 ve b\u00fcz\u00fclmeden \u00f6nceki\/sonraki alanlar\u0131 verir <strong>\u00b1 toleranslarla<\/strong>. 12.0\/6.0 gibi bir boyut okurken bu toleranslar\u0131 dikkate al\u0131n; \u00e7ift, her iki \u00e7ap\u0131n da tam oldu\u011fu anlam\u0131na gelmez.<\/p>\n<table>\n<thead>\n<tr>\n<th>Nominal boyut \u00e7ifti (mm)<\/th>\n<th>B\u00fcz\u00fclmeden \u00f6nceki ID (mm)<\/th>\n<th>B\u00fcz\u00fclme sonras\u0131 alan\u2020 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1.0\/0.5<\/td>\n<td>1.0 \u00b1 0.3<\/td>\n<td>0.5 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td>1.5\/0.75<\/td>\n<td>1.5 \u00b1 0.3<\/td>\n<td>0.75 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td>2.0\/1.0<\/td>\n<td>2.0 \u00b1 0.3<\/td>\n<td>1.0 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td>2.5\/1.25<\/td>\n<td>2.5 \u00b1 0.3<\/td>\n<td>1.25 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td>3.0\/1.5<\/td>\n<td>3.0 \u00b1 0.3<\/td>\n<td>1.5 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td>3.5\/1.75<\/td>\n<td>3.5 \u00b1 0.3<\/td>\n<td>1.75 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td>4.0\/2.0<\/td>\n<td>4.0 \u00b1 0.3<\/td>\n<td>2.0 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td>5.0\/2.5<\/td>\n<td>5.0 \u00b1 0.3<\/td>\n<td>2.5 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td>6.0\/3.0<\/td>\n<td>6.0 \u00b1 0.4<\/td>\n<td>3.0 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td>7.0\/3.5<\/td>\n<td>7.0 \u00b1 0.4<\/td>\n<td>3.5 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td>8.0\/4.0<\/td>\n<td>8.0 \u00b1 0.4<\/td>\n<td>4.0 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td>9.0\/4.5<\/td>\n<td>9.0 \u00b1 0.4<\/td>\n<td>4.5 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td>10.0\/5.0<\/td>\n<td>10.0 \u00b1 0.4<\/td>\n<td>5.0 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td>11.0\/5.5<\/td>\n<td>11.0 \u00b1 0.4<\/td>\n<td>5.5 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td>12.0\/6.0<\/td>\n<td>12.0 \u00b1 0.4<\/td>\n<td>6.0 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>13.0\/6.5<\/td>\n<td>13.0 \u00b1 0.4<\/td>\n<td>6.5 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>14.0\/7.0<\/td>\n<td>14.0 \u00b1 0.4<\/td>\n<td>7.0 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>15.0\/7.5<\/td>\n<td>15.0 \u00b1 0.4<\/td>\n<td>7.5 \u00b1 0.4<\/td>\n<\/tr>\n<tr>\n<td>16.0\/8.0<\/td>\n<td>16.0 \u00b1 0.5<\/td>\n<td>8.0 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>17.0\/8.5<\/td>\n<td>17.0 \u00b1 0.5<\/td>\n<td>8.5 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>18.0\/9.0<\/td>\n<td>18.0 \u00b1 0.5<\/td>\n<td>9.0 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>20.0\/10.0<\/td>\n<td>20.0 \u00b1 0.5<\/td>\n<td>10.0 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>22.0\/11.0<\/td>\n<td>22.0 \u00b1 0.5<\/td>\n<td>11.0 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>25.0\/12.5<\/td>\n<td>25.0 \u00b1 0.8<\/td>\n<td>12.5 \u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td>28.0\/14.0<\/td>\n<td>28.0 \u00b1 0.8<\/td>\n<td>14.0 \u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td>30.0\/15.0<\/td>\n<td>30.0 \u00b1 0.8<\/td>\n<td>15.0 \u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td>35.0\/17.5<\/td>\n<td>35.0 \u00b1 0.8<\/td>\n<td>17.5 \u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td>40.0\/20.0<\/td>\n<td>40.0 \u00b1 1.5<\/td>\n<td>20.0 \u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td>45.0\/22.5<\/td>\n<td>45.0 \u00b1 1.5<\/td>\n<td>22.5 \u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td>50.0\/25.0<\/td>\n<td>50.0 \u00b1 1.5<\/td>\n<td>25.0 \u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td>60.0\/30.0<\/td>\n<td>60.0 \u00b1 1.5<\/td>\n<td>30.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>70.0\/35.0<\/td>\n<td>70.0 \u00b1 1.5<\/td>\n<td>35.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>80.0\/40.0<\/td>\n<td>80.0 \u00b1 1.5<\/td>\n<td>40.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>90.0\/45.0<\/td>\n<td>90.0 \u00b1 1.5<\/td>\n<td>45.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>100.0\/50.0<\/td>\n<td>100.0 \u00b1 1.5<\/td>\n<td>50.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>120.0\/60.0<\/td>\n<td>120.0 \u00b1 1.5<\/td>\n<td>60.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>150.0\/75.0<\/td>\n<td>150.0 \u00b1 1.5<\/td>\n<td>75.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>180.0\/90.0<\/td>\n<td>180.0 \u00b1 1.5<\/td>\n<td>90.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>200.0\/100.0<\/td>\n<td>200.0 \u00b1 1.5<\/td>\n<td>100.0 \u00b1 1.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u2020 Kaynak, \u00b1 de\u011ferleri listelerken b\u00fcz\u00fclme sonras\u0131 s\u00fctununu \u201cMaks. I.D. b\u00fcz\u00fclmeden sonra\u201d olarak ba\u015fl\u0131kland\u0131r\u0131r. Bu de\u011ferler, niteliksiz maksimum limitler olarak yeniden d\u00f6k\u00fclmek yerine burada de\u011fi\u015fmeden tekrarlan\u0131r. Herhangi bir s\u0131n\u0131r\u0131n yak\u0131n\u0131na bir uyum onaylamadan \u00f6nce se\u00e7ilen HTS boyutu i\u00e7in kesin tedarik edilen\/geri kazan\u0131lan limitleri al\u0131n.<\/p>\n<h3>3:1 yap\u0131\u015fkan astarl\u0131 boru \u2014 HS3X<\/h3>\n<p>Bu <a href=\"https:\/\/yocl.com\/tr\/product\/hs3x-3-1-dual-wall-adhesive-lined-heat-shrink-tubing\/\">YOCL HS3X boyut tablosu<\/a> belirtir <strong>sa\u011flanan minimum ID<\/strong> ve <strong>geri kazan\u0131lan maksimum ID<\/strong>. A\u015fa\u011f\u0131daki Metrik giri\u015fleri YOCL'nin yay\u0131nlanan de\u011ferlerini korur; kesirli in\u00e7 boyut etiketlerinden yeniden hesaplanmazlar.<\/p>\n<table>\n<thead>\n<tr>\n<th>Metrik boyut giri\u015fi (mm)<\/th>\n<th>Sa\u011flanan ID (mm), minimum<\/th>\n<th>Geri kazan\u0131lan ID (mm), maksimum<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2.4<\/td>\n<td>\u22652.4<\/td>\n<td>\u22640.8<\/td>\n<\/tr>\n<tr>\n<td>3.2<\/td>\n<td>\u22653.2<\/td>\n<td>\u22641.0<\/td>\n<\/tr>\n<tr>\n<td>4.8<\/td>\n<td>\u22654.8<\/td>\n<td>\u22641.6<\/td>\n<\/tr>\n<tr>\n<td>6.4<\/td>\n<td>\u22656.4<\/td>\n<td>\u22642.2<\/td>\n<\/tr>\n<tr>\n<td>7.9<\/td>\n<td>\u22657.9<\/td>\n<td>\u22642.7<\/td>\n<\/tr>\n<tr>\n<td>9.5<\/td>\n<td>\u22659.5<\/td>\n<td>\u22643.2<\/td>\n<\/tr>\n<tr>\n<td>12.7<\/td>\n<td>\u226512.7<\/td>\n<td>\u22644.2<\/td>\n<\/tr>\n<tr>\n<td>15.0<\/td>\n<td>\u226515.0<\/td>\n<td>\u22645.2<\/td>\n<\/tr>\n<tr>\n<td>19.1<\/td>\n<td>\u226519.1<\/td>\n<td>\u22646.3<\/td>\n<\/tr>\n<tr>\n<td>25.4<\/td>\n<td>\u226525.4<\/td>\n<td>\u22648.5<\/td>\n<\/tr>\n<tr>\n<td>30.0<\/td>\n<td>\u226530.0<\/td>\n<td>\u226410.2<\/td>\n<\/tr>\n<tr>\n<td>39.0<\/td>\n<td>\u226539.0<\/td>\n<td>\u226413.5<\/td>\n<\/tr>\n<tr>\n<td>50.0<\/td>\n<td>\u226550.0<\/td>\n<td>\u226417.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>4:1 yap\u0131\u015fkan astarl\u0131 boru \u2014 HS4X<\/h3>\n<p>Bu <a href=\"https:\/\/yocl.com\/tr\/product\/hs4x-4-1-dual-wall-adhesive-lined-heat-shrink-tubing\/\">YOCL HS4X boyut tablosu<\/a> sa\u011flanan\/geri kazan\u0131lan boyut \u00e7iftlerini ve a\u00e7\u0131k \u2265\/\u2264 s\u0131n\u0131rlar\u0131n\u0131 kullan\u0131r. \u00d6rne\u011fin, 16.0\/4.0 en az 16.0 mm olan sa\u011flanan bir \u00e7ap ve en fazla 4.0 mm olan geri kazan\u0131lm\u0131\u015f bir \u00e7ap belirtir.<\/p>\n<table>\n<thead>\n<tr>\n<th>Metrik boyut giri\u015fi (mm)<\/th>\n<th>Sa\u011flanan ID (mm), minimum<\/th>\n<th>Geri kazan\u0131lan ID (mm), maksimum<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>4.0\/1.0<\/td>\n<td>\u22654.0<\/td>\n<td>\u22641.0<\/td>\n<\/tr>\n<tr>\n<td>6.0\/1.5<\/td>\n<td>\u22656.0<\/td>\n<td>\u22641.5<\/td>\n<\/tr>\n<tr>\n<td>8.0\/2.0<\/td>\n<td>\u22658.0<\/td>\n<td>\u22642.0<\/td>\n<\/tr>\n<tr>\n<td>12.0\/3.0<\/td>\n<td>\u226512.0<\/td>\n<td>\u22643.0<\/td>\n<\/tr>\n<tr>\n<td>16.0\/4.0<\/td>\n<td>\u226516.0<\/td>\n<td>\u22644.0<\/td>\n<\/tr>\n<tr>\n<td>20.0\/5.0<\/td>\n<td>\u226520.0<\/td>\n<td>\u22645.0<\/td>\n<\/tr>\n<tr>\n<td>24.0\/6.0<\/td>\n<td>\u226524.0<\/td>\n<td>\u22646.0<\/td>\n<\/tr>\n<tr>\n<td>32.0\/8.0<\/td>\n<td>\u226532.0<\/td>\n<td>\u22648.0<\/td>\n<\/tr>\n<tr>\n<td>52.0\/13.0<\/td>\n<td>\u226552.0<\/td>\n<td>\u226413.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Bu tablolar yaln\u0131zca HTS, HS3X ve HS4X'yi kapsar. Di\u011fer tek cidarl\u0131, yar\u0131 sert, bara veya \u00f6zel kaliteler kendi boyut tablolar\u0131na ihtiya\u00e7 duyar; e\u015fle\u015fen bir oran boyutlar\u0131n\u0131 de\u011fi\u015ftirilebilir yapmaz.<\/p>\n<h2>Geni\u015fletilmi\u015f, geri kazan\u0131lm\u0131\u015f ve tak\u0131lm\u0131\u015f \u00e7aplar farkl\u0131 durumlard\u0131r<\/h2>\n<p><strong>\u0130\u00e7 \u00e7ap (ID)<\/strong> boru \u00e7ap\u0131n\u0131 \u00f6l\u00e7er. <strong>D\u0131\u015f \u00e7ap (OD)<\/strong> kabloyu veya sarmas\u0131 gereken bile\u015feni \u00f6l\u00e7er.<\/p>\n<ul>\n<li><strong>Geni\u015fletilmi\u015f\/teslim edildi\u011fi gibi:<\/strong> ge\u00e7i\u015f kontrol\u00fc i\u00e7in kullan\u0131lan, \u0131s\u0131tmadan \u00f6nceki mevcut i\u00e7 \u00e7ap.<\/li>\n<li><strong>Serbest\u00e7e geri kazan\u0131lm\u0131\u015f:<\/strong> i\u00e7inde k\u0131s\u0131tlay\u0131c\u0131 bir nesne olmadan belirtilen geri kazan\u0131m ko\u015fullar\u0131 alt\u0131nda ula\u015f\u0131lan i\u00e7 \u00e7ap.<\/li>\n<li><strong>Tak\u0131lm\u0131\u015f:<\/strong> k\u0131l\u0131f nesnenin etraf\u0131na uyum sa\u011flar. Serbest geri kazan\u0131m i\u00e7 \u00e7ap\u0131ndan daha b\u00fcy\u00fck bir kablo, bu i\u00e7 \u00e7apa ula\u015fmas\u0131n\u0131 engeller.<\/li>\n<\/ul>\n<p>HS4X 12.0\/3.0 sat\u0131r\u0131 i\u00e7in, iki katalog alan\u0131 \u226512.0 mm teslim edilmi\u015f ve \u22643.0 mm geri kazan\u0131lm\u0131\u015f de\u011ferindedir. Hi\u00e7bir alan, daha b\u00fcy\u00fck bir kablo etraf\u0131na monte edilmi\u015f bir k\u0131l\u0131f\u0131n 3.0 mm i\u00e7 \u00e7apa sahip olaca\u011f\u0131n\u0131 garanti etmez.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/heat-shrink-tubing-size-chart-diameter-states.webp\" alt=\"End-on schematic showing expanded and freely recovered inside-diameter limits for YOCL HS4X 12.0\/3.0 tubing, with arrows across the bore.\"><figcaption>HS4X 12.0\/3.0 catalogue limits. Schematic, not to scale; an internal object restricts recovery and changes the installed state.<\/figcaption><\/figure>\n<p>Read the signs as part of the specification: <strong>\u2265<\/strong> supplies a lower bound; <strong>\u2264<\/strong> supplies an upper bound; <strong>\u00b1<\/strong> retains variation around the stated value. Do not erase these signs when copying dimensions into an enquiry.<\/p>\n<p>Also keep the nominal ratio separate. The HS3X 6.4 mm entry lists a recovered limit of <strong>\u22642.2 mm<\/strong>, while 6.4 \u00f7 3 is approximately 2.13 mm. Replacing 2.2 with that calculation would change the published specification.<\/p>\n<p>For the wider terminology map, see <a href=\"https:\/\/yocl.com\/tr\/what-is-heat-shrink-tubing\/\">Is\u0131 Daralan Makaron Nedir? Oranlar, Duvarlar ve Yap\u0131\u015fkan Astarlar<\/a>.<\/p>\n<h2>Use both diameter limits from the same row<\/h2>\n<p>For a preliminary check of <strong>round parts and open-ended tubing<\/strong>, identify:<\/p>\n<ul>\n<li><strong>Largest pass-over OD:<\/strong> the widest round feature the unshrunk sleeve must cross, including a connector or joint.<\/li>\n<li><strong>Smallest covered OD:<\/strong> the narrowest round cable surface onto which the sleeve needs to recover.<\/li>\n<\/ul>\n<p>Then compare both dimensions with one size row:<\/p>\n<p><strong>Minimum supplied ID &gt; largest pass-over OD<\/strong><\/p>\n<p><strong>Maximum freely recovered ID &lt; smallest covered OD<\/strong><\/p>\n<p>NASA\u2019n\u0131n <a href=\"https:\/\/standards.nasa.gov\/sites\/default\/files\/standards\/KSC\/F\/KSC-E-165-REV-F.pdf\" target=\"_blank\" rel=\"noopener\">KSC-E-165 Revizyon F, \u00a73.8.1.1.1(a)<\/a> documents this expanded-larger\/recovered-smaller relationship for electrical ground-support-equipment fabrication. It supports the dimensional principle, rather than approval of a YOCL assembly.<\/p>\n<p>Equality leaves no dimensional margin. Include component tolerances and the model&#8217;s installation allowance; this chart does not prescribe a universal clearance percentage. Flat busbars, irregular connectors and bundles need a geometry review rather than a single round-diameter comparison.<\/p>\n<h3>Worked example: a 14 mm feature and a 5 mm cable<\/h3>\n<p>Assume the largest round feature is <strong>14 mm OD<\/strong> and the smallest cable jacket is <strong>5 mm OD<\/strong>. These are illustrative inputs, not measurements of a particular installation.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/heat-shrink-tubing-size-chart-pass-over-dimensions.webp\" alt=\"Illustrative round connection with a 14 mm outside-diameter feature and a 5 mm cable jacket, identifying the two dimensions used in the tubing-fit example.\"><figcaption>Measure the largest pass-over feature and the smallest covered surface separately. These illustrative dimensions are the inputs to the table below.<\/figcaption><\/figure>\n<table>\n<thead>\n<tr>\n<th>Series and metric size<\/th>\n<th>Minimum supplied ID<\/th>\n<th>Maximum recovered ID<\/th>\n<th>Supplied minimum &gt;14 mm?<\/th>\n<th>Recovered maximum &lt;5 mm?<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>HS3X 12.7 mm<\/td>\n<td>12.7 mm<\/td>\n<td>4.2 mm<\/td>\n<td>Belirlenmemi\u015f<\/td>\n<td>Ge\u00e7ti<\/td>\n<\/tr>\n<tr>\n<td>HS3X 15.0 mm<\/td>\n<td>15.0 mm<\/td>\n<td>5.2 mm<\/td>\n<td>Ge\u00e7ti<\/td>\n<td>Belirlenmemi\u015f<\/td>\n<\/tr>\n<tr>\n<td>HS4X 16.0\/4.0 mm<\/td>\n<td>16.0 mm<\/td>\n<td>4.0 mm<\/td>\n<td>Ge\u00e7ti<\/td>\n<td>Ge\u00e7ti<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>HS4X 16.0\/4.0 passes both dimensional inequalities for these inputs.<\/strong> It remains a candidate requiring application review. The HS3X 12.7 row does not establish clearance over 14 mm. Moving up to HS3X 15.0 establishes that clearance, but its 5.2 mm recovered upper limit does not establish contraction below a 5 mm jacket.<\/p>\n<p>\u201cNot established\u201d does not claim every specimen will fail. It means the published bound is insufficient to assure that check. Choose the nearest listed row that satisfies <strong>both<\/strong> requirements with the specified allowance, rather than simply taking the next larger size.<\/p>\n<h2>What the diameter chart does not decide<\/h2>\n<p>Measure the actual insulated cable OD. <strong>American Wire Gauge (AWG)<\/strong> or conductor cross-sectional area does not specify the jacket diameter, and a flattened sleeve&#8217;s width is not its inside diameter. A nominal fractional-inch label likewise cannot replace the model&#8217;s stated diameter fields.<\/p>\n<p>The installed sleeve also needs enough space and coverage. Check wall thickness with its measurement state, finished outside dimensions and the product&#8217;s longitudinal-change information. Do not assume a freely recovered wall value is the wall on a partly recovered cable, or apply the diameter shrink ratio to cut length. Where a wall field is labelled \u201ctotal\u201d, do not add its adhesive thickness again.<\/p>\n<p>For the liner decision, use <a href=\"https:\/\/yocl.com\/tr\/single-wall-vs-dual-wall-heat-shrink-tubing\/\">Tek Duvarl\u0131 ve \u00c7ift Duvarl\u0131 Is\u0131yla Daralan Makaron Kar\u015f\u0131la\u015ft\u0131rmas\u0131<\/a>. A successful diameter check alone establishes neither an electrical rating nor a sealed connection.<\/p>\n<p>To confirm a size, use the <a href=\"https:\/\/yocl.com\/tr\/heat-shrink-tubing-manufacturer\/\">YOCL \u0131s\u0131yla daralan makaron katalo\u011fu<\/a> and provide the series, exact size row, largest pass-over dimension, smallest covered dimension and required coverage length. Request the applicable dimensional limits and installation information for the intended material and duty.<\/p>\n<h2>Referanslar<\/h2>\n<ol>\n<li>YOCL \u00fcr\u00fcn bilgileri \u2014 <a href=\"https:\/\/yocl.com\/tr\/product\/hts-2-1-single-wall-heat-shrink-tubing\/\">HTS 2:1 Tek Duvarl\u0131 Is\u0131yla Daralan Makaron<\/a>. Complete 39-row dimension table, nominal pair meaning and published \u00b1 fields; checked 6 October 2026.<\/li>\n<li>YOCL \u00fcr\u00fcn bilgileri \u2014 <a href=\"https:\/\/yocl.com\/tr\/product\/hs3x-3-1-dual-wall-adhesive-lined-heat-shrink-tubing\/\">HS3X 3:1 Yap\u0131\u015fkan Astarl\u0131 \u00c7ift Cidarl\u0131 Is\u0131yla Daralan Makaron<\/a>. Complete 13-row dimension table and supplied\/recovered limits; checked 6 October 2026.<\/li>\n<li>YOCL \u00fcr\u00fcn bilgileri \u2014 <a href=\"https:\/\/yocl.com\/tr\/product\/hs4x-4-1-dual-wall-adhesive-lined-heat-shrink-tubing\/\">HS4X 4:1 \u00c7ift Cidarl\u0131 Yap\u0131\u015fkan Astarl\u0131 Is\u0131yla Daralan Makaron<\/a>. Complete nine-row dimension table and supplied\/recovered limits; checked 6 October 2026.<\/li>\n<li>NASA Kennedy Uzay Merkezi \u2014 <a href=\"https:\/\/standards.nasa.gov\/sites\/default\/files\/standards\/KSC\/F\/KSC-E-165-REV-F.pdf\" target=\"_blank\" rel=\"noopener\">KSC-E-165 Revision F, 20 December 2021<\/a>, <em>Electrical Ground Support Equipment Fabrication, Specification for<\/em>. Section 3.8.1.1.1(a), printed page 59; dimensional principle within its ground-support-equipment scope.<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>Read a heat shrink tubing size chart using two inside diameters: the expanded bore before heating and the freely recovered bore after shrinking. The supplied bore must clear the largest feature; the recovered bore must be smaller than the surface it needs to grip. Use the actual row limits, rather than dividing a nominal size [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":2453,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[165],"tags":[],"class_list":["post-2454","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-heat-shrink-insulation"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/2454","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/comments?post=2454"}],"version-history":[{"count":1,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/2454\/revisions"}],"predecessor-version":[{"id":2455,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/2454\/revisions\/2455"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/2453"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=2454"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/categories?post=2454"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/tags?post=2454"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}