{"id":2590,"date":"2026-10-07T03:51:56","date_gmt":"2026-10-07T03:51:56","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=36f8595be15c3acd10989e723fdd1091efa1e6a16b70b7e57de9732bdcd70204"},"modified":"2026-10-07T03:51:56","modified_gmt":"2026-10-07T03:51:56","slug":"single-vs-twin-wire-ferrules","status":"publish","type":"post","link":"https:\/\/yocl.com\/tr\/single-vs-twin-wire-ferrules\/","title":{"rendered":"Tekli vs \u00c7iftli Tel Y\u00fcks\u00fckleri: Terminal Uyumu ve Tel Kombinasyonlar\u0131"},"content":{"rendered":"<p><strong>Haz\u0131rlanm\u0131\u015f u\u00e7, al\u0131c\u0131 ba\u011flant\u0131 taraf\u0131ndan izin veriliyorsa, tek iletken i\u00e7in tek telli y\u00fcks\u00fck kullan\u0131n. Al\u0131c\u0131 ba\u011flant\u0131da bir haz\u0131rlanm\u0131\u015f ucu payla\u015fabilen belgelenmi\u015f iki telli bir kombinasyon i\u00e7in \u00e7ift y\u00fcks\u00fck kullan\u0131n.<\/strong> \u0130ki tel i\u00e7in, ayr\u0131 ayr\u0131 y\u00fcks\u00fckl\u00fc u\u00e7lar da uygun olabilir. Se\u00e7im, izin verilen ba\u011flant\u0131 d\u00fczenine, her telin spesifikasyonuna ve bitmi\u015f ucun geometrisine ba\u011fl\u0131d\u0131r.<\/p>\n<p>\u00c7ift y\u00fcks\u00fck, bir ortak haz\u0131rlanm\u0131\u015f u\u00e7 olu\u015fturur. \u0130ki tek y\u00fcks\u00fck, iki bireysel u\u00e7 olu\u015fturur. Bu d\u00fczenlemeler, ayn\u0131 elektrik d\u00fc\u011f\u00fcm\u00fcne hizmet etseler bile farkl\u0131 uyum kontrolleri gerektirir.<\/p>\n<h2>Al\u0131c\u0131 Ba\u011flant\u0131ya G\u00f6re Se\u00e7in<\/h2>\n<p>Se\u00e7enekleri ayn\u0131 hedefle kar\u015f\u0131la\u015ft\u0131r\u0131n: belirtilen teli veya tel \u00e7iftini izin verilen bir ba\u011flant\u0131da sonland\u0131r\u0131n.<\/p>\n<table>\n<thead>\n<tr>\n<th>Tel ve ba\u011flant\u0131 durumu<\/th>\n<th>Uygun d\u00fczenleme<\/th>\n<th>Se\u00e7imi kontrol eden ko\u015ful<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tek iletken, izin verilen y\u00fcks\u00fckl\u00fc ba\u011flant\u0131l\u0131<\/td>\n<td>Tek tek y\u00fcks\u00fck<\/td>\n<td>\u0130letkeni ve haz\u0131rlanm\u0131\u015f ucu ba\u011flant\u0131 gereksinimlerine uydurun<\/td>\n<\/tr>\n<tr>\n<td>Her biri kendi izin verilen kelep\u00e7eleme noktas\u0131n\u0131 kullanan iki iletken<\/td>\n<td>Her tel i\u00e7in birer tane olmak \u00fczere iki tek y\u00fcks\u00fck<\/td>\n<td>Noktalar aras\u0131nda gerekli elektriksel ba\u011flant\u0131y\u0131 kurun<\/td>\n<\/tr>\n<tr>\n<td>Tek bir ortak haz\u0131rlanm\u0131\u015f ucu payla\u015fan iki e\u015fit boyutta iletken<\/td>\n<td>Bu \u00e7ift i\u00e7in tasarlanm\u0131\u015f ikiz y\u00fcks\u00fck<\/td>\n<td>Uygulanabilir y\u00fcks\u00fck\/terminal rotas\u0131n\u0131 ve bitmi\u015f u\u00e7 uyumunu belirleyin<\/td>\n<\/tr>\n<tr>\n<td>Hem ayr\u0131 u\u00e7 hem de ortak u\u00e7 d\u00fczenlemelerine izin verilir<\/td>\n<td>Herhangi bir d\u00fczenleme dikkate al\u0131nabilir<\/td>\n<td>Ger\u00e7ek kelep\u00e7eleme d\u00fczenini, profili, uzunlu\u011fu ve yaka bo\u015flu\u011funu kar\u015f\u0131la\u015ft\u0131r\u0131n<\/td>\n<\/tr>\n<tr>\n<td>Tek bir kelep\u00e7eyi payla\u015fan iki ayr\u0131 y\u00fcks\u00fckl\u00fc u\u00e7<\/td>\n<td>Yaln\u0131zca bu yap\u0131land\u0131rmaya izin verildi\u011fi yerlerde iki tekli<\/td>\n<td>Bir ikiz u\u00e7 i\u00e7in izin, iki ayr\u0131 u\u00e7 i\u00e7in izin anlam\u0131na gelmez<\/td>\n<\/tr>\n<tr>\n<td>Destekleyici kombinasyon verileri olmayan kar\u0131\u015f\u0131k boyutlu bir \u00e7ift<\/td>\n<td>Ortak u\u00e7 ikamesi do\u011frulanmad\u0131<\/td>\n<td>A\u00e7\u0131k\u00e7a belgelenmi\u015f bir kombinasyon veya uygun ayr\u0131 ba\u011flant\u0131lar kullan\u0131n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Yap\u0131 ve terminoloji i\u00e7in <a href=\"https:\/\/yocl.com\/tr\/what-is-a-wire-ferrule\/\">tel y\u00fcks\u00fck genel bak\u0131\u015f<\/a> arka plan\u0131 sa\u011flar. Burada karar, hangi haz\u0131rlanm\u0131\u015f u\u00e7 d\u00fczenlemesinin ba\u011flant\u0131ya uygun oldu\u011fudur.<\/p>\n<h2>Telleri, Haz\u0131rlanm\u0131\u015f U\u00e7lar\u0131 ve Kelep\u00e7eleme Noktalar\u0131n\u0131 Ayr\u0131 Ayr\u0131 Say\u0131n<\/h2>\n<p>\u0130ki tek y\u00fcks\u00fck ile her iletken kendi metal k\u0131l\u0131f\u0131n\u0131 korur. \u00c7iftin <strong>iki orijinal teli ve iki haz\u0131rlanm\u0131\u015f ucu vard\u0131r<\/strong>. Tek bir \u00e7ift y\u00fcks\u00fck ile her iki iletken de bir k\u0131l\u0131f payla\u015f\u0131r: <strong>iki orijinal tel ve bir haz\u0131rlanm\u0131\u015f u\u00e7<\/strong>.<\/p>\n<p>Bir terminal grubunun birka\u00e7 ba\u011flant\u0131 noktas\u0131 olabilir. \u201cBir terminal\u201din bir a\u00e7\u0131kl\u0131k veya bir kelep\u00e7e anlam\u0131na geldi\u011fini varsaymak yerine, kullan\u0131lan ger\u00e7ek kelep\u00e7eleme noktalar\u0131n\u0131 say\u0131n. Ayr\u0131 noktalar\u0131n ayn\u0131 elektriksel d\u00fc\u011f\u00fcm\u00fc olu\u015fturmas\u0131 gerekiyorsa, belgelenmi\u015f dahili ba\u011flant\u0131lar\u0131n\u0131 veya ge\u00e7erli k\u00f6pr\u00fc d\u00fczenlemesini do\u011frulay\u0131n. Biti\u015fik terminaller otomatik olarak ba\u011fl\u0131 de\u011fildir.<\/p>\n<p>U\u00e7lar\u0131 ayr\u0131 tutmak, d\u00fczenlemenin bireysel kelep\u00e7eleme noktalar\u0131n\u0131 kullanmas\u0131na olanak tan\u0131r. Bunlar\u0131 bir \u00e7ift i\u00e7inde birle\u015ftirmek, sunulan ucu ortak bir kelep\u00e7eleme noktas\u0131na d\u00f6n\u00fc\u015ft\u00fcr\u00fcr. Hi\u00e7bir yap\u0131, al\u0131c\u0131 cihaz\u0131n ba\u011flant\u0131 gereksinimlerini ortadan kald\u0131rmaz.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/single-vs-twin-wire-ferrules-prepared-ends.webp\" alt=\"\u0130ki e\u015fit boyutta tel, iki ayr\u0131 tek kovanl\u0131 u\u00e7 veya bir payla\u015f\u0131lan ikiz kovanl\u0131 u\u00e7 olarak haz\u0131rlanm\u0131\u015f\"><figcaption>Ayn\u0131 iki tel, iki bireysel u\u00e7 veya bir ortak u\u00e7 sunabilir. Bu kar\u015f\u0131la\u015ft\u0131rma, bir terminalin hangi d\u00fczenlemeye izin verdi\u011fini belirlemez.<\/figcaption><\/figure>\n<h2>Ayn\u0131 Tel \u00c7iftini Kar\u015f\u0131la\u015ft\u0131r\u0131n: \u0130ki E1008 U\u00e7 veya Bir TE 1008 U\u00e7<\/h2>\n<p>Ba\u011flant\u0131n\u0131n birle\u015ftirmek i\u00e7in tasarland\u0131\u011f\u0131n\u0131 varsay\u0131n <strong>iki 1.0 mm\u00b2 \u00f6rg\u00fcl\u00fc bak\u0131r iletken<\/strong> ayn\u0131 d\u00fc\u011f\u00fcmde. \u0130ki ayr\u0131 <a href=\"https:\/\/yocl.com\/tr\/product\/e-series-pre-insulated-wire-ferrules\/\">YOCL E1008 tek y\u00fcks\u00fck<\/a> bir <a href=\"https:\/\/yocl.com\/tr\/product\/te-twin-cord-end-connectors\/\">YOCL TE 1008 \u00e7ift y\u00fcks\u00fck<\/a>. ile kar\u015f\u0131la\u015ft\u0131r\u0131n. Bunlar, onaylanm\u0131\u015f ikameler de\u011fil, farkl\u0131 ba\u011flant\u0131 d\u00fczenlemeleri i\u00e7in adaylard\u0131r.<\/p>\n<table>\n<thead>\n<tr>\n<th>Kar\u015f\u0131la\u015ft\u0131rma alan\u0131<\/th>\n<th>\u0130ki E1008 y\u00fcks\u00fck<\/th>\n<th>Bir TE 1008 y\u00fcks\u00fck<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Beyan edilen iletken d\u00fczenlemesi<\/td>\n<td>Her bir y\u00fcks\u00fckte bir adet 1.0 mm\u00b2<\/td>\n<td>Bir y\u00fcks\u00fckte iki adet 1.0 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td>Haz\u0131rlanm\u0131\u015f u\u00e7 say\u0131s\u0131<\/td>\n<td>\u0130ki<\/td>\n<td>Bir<\/td>\n<\/tr>\n<tr>\n<td>A\u00e7\u0131kta kalan metal uzunlu\u011fu F<\/td>\n<td>U\u00e7 ba\u015f\u0131na 8.0 mm<\/td>\n<td>8.0 mm<\/td>\n<\/tr>\n<tr>\n<td>Toplam uzunluk L<\/td>\n<td>14.7 mm y\u00fcks\u00fck ba\u015f\u0131na<\/td>\n<td>15.1 mm<\/td>\n<\/tr>\n<tr>\n<td>Katalog W, etiketlendi\u011fi gibi<\/td>\n<td>3.1 mm y\u00fcks\u00fck ba\u015f\u0131na<\/td>\n<td>5.1 mm<\/td>\n<\/tr>\n<tr>\n<td>S\u0131k\u0131lmam\u0131\u015f t\u00fcp d\u0131\u015f \u00e7ap\u0131 D \/ D\u03a6<\/td>\n<td>1.8 mm y\u00fcks\u00fck ba\u015f\u0131na<\/td>\n<td>2.3 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Bunlar <strong>YOCL\u2019nin beyan edilen nominal katalog boyutlar\u0131<\/strong>, harf anlamlar\u0131 her seri \u00e7izimine g\u00f6re kontrol edilmi\u015ftir. W, etiketlenmi\u015f giri\u015f boyutunu tan\u0131mlar; tam bir maksimum man\u015fon zarf\u0131 de\u011fildir. D, bitmi\u015f s\u0131kmay\u0131 de\u011fil, s\u0131k\u0131lmam\u0131\u015f t\u00fcp\u00fc a\u00e7\u0131klar.<\/p>\n<p>Her iki se\u00e7enekte de F = 8 mm bulunur, ancak haz\u0131rlanm\u0131\u015f u\u00e7 say\u0131lar\u0131 ve nominal geometrileri farkl\u0131d\u0131r. \u0130ki adet E1008 par\u00e7a, yan yana yerle\u015ftirilerek bir TE 1008 par\u00e7a haline gelmez. Terminalin hala uygun d\u00fczenlemeye, a\u00e7\u0131kta kalan uzunlu\u011fa, bitmi\u015f profile ve giri\u015f bo\u015flu\u011funa ihtiyac\u0131 vard\u0131r. Katalog kar\u015f\u0131la\u015ft\u0131rmas\u0131 bu ko\u015fullar\u0131 do\u011frulayamaz.<\/p>\n<p>Di\u011fer iletken boyutlar\u0131 ve uzunluk se\u00e7enekleri i\u00e7in, model kodu deseninden boyutlar\u0131 \u00e7\u0131karmak yerine <a href=\"https:\/\/yocl.com\/tr\/wire-ferrule-size-chart\/\">tel y\u00fcks\u00fck boyut tablosunu<\/a> kullan\u0131n.<\/p>\n<h2>Bitmi\u015f Ucu Terminalin Ba\u011flant\u0131 Gereksinimlerine Uygun Hale Getirin<\/h2>\n<p>Tam al\u0131c\u0131 cihaz\u0131n ba\u011flant\u0131 verilerini ve talimatlar\u0131n\u0131 okuyun. Tek bir y\u00fcks\u00fckl\u00fc iletken, bir ikiz y\u00fcks\u00fckte iki iletken ve iki ayr\u0131 y\u00fcks\u00fckl\u00fc u\u00e7 i\u00e7in herhangi bir kategoriyi ay\u0131rt edin. Bir ba\u015fl\u0131k iletken aral\u0131\u011f\u0131, hangi yap\u0131land\u0131rman\u0131n ge\u00e7erli oldu\u011funu \u00e7\u00f6zmez.<\/p>\n<p>Belirtilen yap\u0131land\u0131rmay\u0131 \u00fc\u00e7 fiziksel \u00f6zellikle kar\u015f\u0131la\u015ft\u0131r\u0131n:<\/p>\n<ul>\n<li><strong>Bitmi\u015f metal profil:<\/strong> uygulanabilir s\u0131kma i\u015fleminden sonraki \u015fekli ve boyutlar\u0131. Katalog \u00e7ap\u0131 yetersizdir; yaln\u0131zca kare veya alt\u0131gen profil ad\u0131, uyumu sa\u011flamaz.<\/li>\n<li><strong>A\u00e7\u0131kta kalan iletken uzunluk:<\/strong> al\u0131nan ba\u011flant\u0131 i\u00e7in mevcut metal. Cihaz\u0131n haz\u0131rl\u0131k gereksinimleriyle e\u015fle\u015ftirin; F ve genel L, soyma talimatlar\u0131 de\u011fildir.<\/li>\n<li><strong>Yaka ve giri\u015f bo\u015flu\u011fu:<\/strong> terminal a\u011fz\u0131 etraf\u0131ndaki tam yaka ve tel giri\u015f d\u00fczenlemesi. A\u00e7\u0131kl\u0131\u011fa giren bir burun, t\u00fcm ucun do\u011fru \u015fekilde oturabilece\u011fini kan\u0131tlamaz.<\/li>\n<\/ul>\n<p>Standartlara dayal\u0131 bir uyumluluk yolu olabilir. Ekipman kablolama terminalleri i\u00e7in <strong>UL 486E kapsam\u0131 dahilinde<\/strong>, halka a\u00e7\u0131k \u00a71.4, y\u00fcks\u00fcklerin kendi de\u011ferleri ve talimatlar\u0131 dahilinde kullan\u0131lmas\u0131 ve a\u00e7\u0131kta kalan iletken uzunlu\u011funun konekt\u00f6r \u00fcreticisinin \u015ferit uzunlu\u011fu gereksinimlerini kar\u015f\u0131lamas\u0131 ko\u015fuluyla, UL 486F kapsam\u0131nda de\u011ferlendirilmi\u015f y\u00fcks\u00fcklerin kullan\u0131m\u0131na izin verir. <a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?UniqueKey=45724\" target=\"_blank\" rel=\"noopener\">UL 486E, S\u00fcr\u00fcm 6<\/a>.<\/p>\n<p>Bu kapsaml\u0131 yol, her cihaz\u0131n ayr\u0131 bir \u201c\u00e7ift onayl\u0131\u201d etiketi ta\u015f\u0131mas\u0131n\u0131 gerektiren bir kural de\u011fildir. Ayr\u0131ca, belirli bir YOCL modelinin UL 486F i\u00e7in de\u011ferlendirildi\u011fi veya se\u00e7ilen ekipmana uydu\u011fu anlam\u0131na gelmez. Uygulanabilir yolu ve ger\u00e7ek model kan\u0131tlar\u0131n\u0131 kaydedin.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/single-vs-twin-wire-ferrules-terminal-fit.webp\" alt=\"Bir terminal giri\u015finin yan\u0131nda haz\u0131rlanm\u0131\u015f kavramsal ikiz, metal profil, a\u00e7\u0131kta kalan uzunluk ve yaka bo\u015flu\u011funu tan\u0131mlar\"><figcaption>Tamamlanm\u0131\u015f profili, a\u00e7\u0131kta kalan iletken uzunlu\u011funu ve yaka bo\u015flu\u011funu izin verilen ba\u011flant\u0131ya g\u00f6re kontrol edin. Kavramsal g\u00f6r\u00fcn\u00fcm, onaylanm\u0131\u015f bir terminal kombinasyonu g\u00f6stermiyor.<\/figcaption><\/figure>\n<h2>E\u015fit Boyutlu \u00c7iftler, Kar\u0131\u015f\u0131k Boyutlar ve Toplam Alan<\/h2>\n<p><strong>2 \u00d7 1.0 mm\u00b2, her biri nominal olarak 1.0 mm\u00b2 olan iki kablo anlam\u0131na gelir.<\/strong> Alanlar\u0131 2.0 mm\u00b2'a eklenir, ancak bu, \u00e7ift i\u00e7in tek telli bir 2.0 mm\u00b2 y\u00fcks\u00fck\u00fcn\u00fc nitelendirmez veya terminal ak\u0131m kapasitesini belirlemez. Orijinal iletken say\u0131s\u0131n\u0131 ve spesifikasyonunu koruyun.<\/p>\n<p>YOCL'nin listelenen TE kombinasyonlar\u0131 e\u015fit boyutlu \u00e7iftlerdir. U.S'nin ABD\/Kanada uygulama kapsam\u0131 dahilindedir, <a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?UniqueKey=47552\" target=\"_blank\" rel=\"noopener\">UL 486F'nin kamuya a\u00e7\u0131k \u00a71.2'si<\/a> ayn\u0131 boyutta bir telli bak\u0131r iletkeni veya ayn\u0131 boyutta iki telli bak\u0131r iletkeni kapsar.<\/p>\n<p>\u0130\u00e7in <strong>0.75 mm\u00b2 + 1.0 mm\u00b2<\/strong>, 1.75 mm\u00b2'nin toplam\u0131 e\u015fle\u015fen bir TE e\u015fit \u00e7ift modeli tan\u0131mlamaz. Bu kar\u0131\u015f\u0131k \u00e7ift, belirtilen ayn\u0131 boyut kapsam\u0131 d\u0131\u015f\u0131ndad\u0131r ve incelenen YOCL katalo\u011funda destekleyici bir kombinasyon verisi yoktur. Tam \u00e7ift, y\u00fcks\u00fck, alet ve al\u0131c\u0131 ba\u011flant\u0131 i\u00e7in belgeler aray\u0131n veya ayr\u0131 ayr\u0131 uygun, izin verilen ba\u011flant\u0131 noktalar\u0131n\u0131 kullan\u0131n. Bu kan\u0131t bo\u015flu\u011fu, her ama\u00e7 i\u00e7in tasarlanm\u0131\u015f kar\u0131\u015f\u0131k boyutlu \u00fcr\u00fcne evrensel bir yasak getirmez.<\/p>\n<h2>Belgeleyebilece\u011finiz D\u00fczenlemeyi Se\u00e7in<\/h2>\n<p>\u0130ki adet 1.0 mm\u00b2 kablo i\u00e7in \u015funu se\u00e7in <strong>iki tekli<\/strong> bireysel u\u00e7lar ve bunlar\u0131n s\u0131k\u0131\u015ft\u0131rma d\u00fczenlemesi izin verildi\u011finde. Se\u00e7in <strong>bir ikili<\/strong> ortak haz\u0131rlanm\u0131\u015f u\u00e7, ge\u00e7erli ba\u011flant\u0131 rotas\u0131 ve fiziksel gereksinimleri kar\u015f\u0131lad\u0131\u011f\u0131nda. Her iki d\u00fczenleme de belgelenmi\u015fse, her ikisi de se\u00e7enek olarak kal\u0131r. Yaln\u0131zca nominal y\u00fcks\u00fck boyutlar\u0131 mevcutsa, terminal kabul\u00fcn\u00fc \u00e7\u00f6z\u00fclmemi\u015f b\u0131rak\u0131n.<\/p>\n<p>G\u00f6zden ge\u00e7irirken <a href=\"https:\/\/yocl.com\/tr\/wire-ferrules-manufacturer\/\">YOCL tel-y\u00fcks\u00fck aral\u0131\u011f\u0131<\/a>, her telin boyutunu, malzemesini ve yap\u0131s\u0131n\u0131, ama\u00e7lanan tekli\/ikili d\u00fczenlemeyi, a\u00e7\u0131k uzunluk gereksinimini, terminal referans\u0131n\u0131 ve miktarlar\u0131n\u0131 belirtin. Bu kombinasyon i\u00e7in ilgili model ve alet belgelerini isteyin.<\/p>\n<h2>Referanslar<\/h2>\n<ol>\n<li><a href=\"https:\/\/yocl.com\/tr\/product\/e-series-pre-insulated-wire-ferrules\/\">YOCL \u00fcr\u00fcn bilgileri \u2014 E Serisi \u00d6n Yal\u0131t\u0131ml\u0131 Tel Y\u00fcks\u00fckleri<\/a>. Yay\u0131nlanm\u0131\u015f model tablosu ve orijinal \u00e7izim; E1008 beyan edilen boyutlar, eri\u015fim tarihi Ekim 7, 2026.<\/li>\n<li><a href=\"https:\/\/yocl.com\/tr\/product\/te-twin-cord-end-connectors\/\">YOCL \u00fcr\u00fcn bilgileri \u2014 TE Twin Kablo Ucu Konnekt\u00f6rleri<\/a>. Yay\u0131nlanm\u0131\u015f model tablosu ve orijinal \u00e7izim; TE 1008 d\u00fczeni ve boyutlar\u0131, eri\u015fim tarihi Ekim 7, 2026.<\/li>\n<li><a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?UniqueKey=45724\" target=\"_blank\" rel=\"noopener\">UL Standartlar ve Kat\u0131l\u0131m \u2014 UL 486E: Al\u00fcminyum ve\/veya Bak\u0131r \u0130letkenlerle Kullan\u0131m \u0130\u00e7in Ekipman Kablo U\u00e7lar\u0131<\/a>. Bask\u0131 6, Ocak 31, 2024; kamu kapsam\u0131, \u00a71.4. \u00dccretli tam standart incelenmedi.<\/li>\n<li><a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?UniqueKey=47552\" target=\"_blank\" rel=\"noopener\">UL Standartlar ve Kat\u0131l\u0131m \u2014 UL 486F: Yal\u0131t\u0131ms\u0131z ve Yal\u0131t\u0131ml\u0131 Kovanlar<\/a>. Bask\u0131 3, Aral\u0131k 9, 2024, revize A\u011fustos 28, 2026; kamu kapsam\u0131, \u00a71.2. \u00dccretli tam standart incelenmedi.<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>Use a single-wire ferrule for one conductor when the receiving connection permits that prepared end. Use a twin ferrule for a documented two-wire combination that can share one prepared end in the receiving connection. For two wires, separately ferruled ends may also be appropriate. The choice depends on the permitted connection arrangement, each wire&#8217;s specification [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":2589,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[164],"tags":[],"class_list":["post-2590","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-terminals-connections"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/2590","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/comments?post=2590"}],"version-history":[{"count":1,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/2590\/revisions"}],"predecessor-version":[{"id":2591,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/2590\/revisions\/2591"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/2589"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=2590"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/categories?post=2590"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/tags?post=2590"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}