{"id":3009,"date":"2026-10-07T18:24:17","date_gmt":"2026-10-07T18:24:17","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=50b20b24330857a3e4450ca5376ad8065c162f26602367da6f9adf3a13077276"},"modified":"2026-10-07T18:24:17","modified_gmt":"2026-10-07T18:24:17","slug":"industrial-plugs-sockets-explained","status":"publish","type":"post","link":"https:\/\/yocl.com\/tr\/industrial-plugs-sockets-explained\/","title":{"rendered":"End\u00fcstriyel Fi\u015fler ve Prizler A\u00e7\u0131klamas\u0131: Kutuplar, Anahtarlama ve De\u011ferlendirmeler"},"content":{"rendered":"<p>End\u00fcstriyel fi\u015fler ve prizler, bir besleme ile ekipman aras\u0131nda ayr\u0131labilir bir g\u00fc\u00e7 ba\u011flant\u0131s\u0131 sa\u011flar. E\u015fle\u015fen bir \u00e7ift, fiziksel aray\u00fcz\u00fc ve elektriksel yap\u0131land\u0131rmas\u0131 ile tan\u0131mlan\u0131r: kutup d\u00fczenlemesi, voltaj ve frekans, ak\u0131m de\u011feri, anahtarlama ve beyan edilen koruma ko\u015fullar\u0131. Renk veya amper tek ba\u015f\u0131na o spesifikasyonun \u00f6nemli k\u0131s\u0131mlar\u0131n\u0131 \u00e7\u00f6z\u00fclmemi\u015f b\u0131rak\u0131r.<\/p>\n<p>IEC 60309 ailesi ay\u0131rt eder <strong>genel gereksinimleri<\/strong> 1 B\u00f6l\u00fcm\u00fcnden <strong>pim ve kontak t\u00fcp\u00fc aksesuarlar\u0131 i\u00e7in boyutsal uyumluluk gereksinimlerini<\/strong> 2 B\u00f6l\u00fcm\u00fcnde. Bunlar \u00fcr\u00fcn standard\u0131 kapsamlar\u0131d\u0131r; bunlar\u0131 adland\u0131rmak, belirli bir konekt\u00f6r\u00fcn sertifikal\u0131 oldu\u011funu veya her kurulum i\u00e7in uygun oldu\u011funu g\u00f6stermez. <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/59916\" target=\"_blank\" rel=\"noopener\">IEC 60309-1 katalog \u00f6zeti<\/a>, <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/59919\" target=\"_blank\" rel=\"noopener\">IEC 60309-2 katalog \u00f6zeti<\/a>.<\/p>\n<p>Ba\u015flang\u0131\u00e7 noktas\u0131 olarak \u00fc\u00e7 soruyu ay\u0131rmak faydal\u0131d\u0131r: <strong>Fiziksel bile\u015fen nedir? Hangi devre kontaklar\u0131n\u0131 sa\u011flar? \u0130\u015faretleri asl\u0131nda neyi belirler?<\/strong><\/p>\n<h2>Fi\u015f, kablo konekt\u00f6r\u00fc ve sabit priz<\/h2>\n<p>Kontak aray\u00fcz\u00fc ve montaj format\u0131 farkl\u0131 \u00f6zellikleri tan\u0131mlar. Di\u015fi bir aray\u00fcz, hareketli bir kablo konekt\u00f6r\u00fcn\u00fcn veya ekipman \u00fczerindeki sabit bir prizin par\u00e7as\u0131 olabilir.<\/p>\n<table>\n<thead>\n<tr>\n<th>Bile\u015fen<\/th>\n<th>Fiziksel rol<\/th>\n<th>YOCL \u00fcr\u00fcn \u00f6rne\u011fi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Kablo fi\u015fi<\/td>\n<td>Kabloya monte edilmi\u015f g\u00f6vdede erkek kontak aray\u00fcz\u00fc<\/td>\n<td><a href=\"https:\/\/yocl.com\/tr\/product\/ip44-industrial-plugs\/\">IP44 end\u00fcstriyel fi\u015fler<\/a><\/td>\n<\/tr>\n<tr>\n<td>Kablo konekt\u00f6r\u00fc veya kablo kuplaj\u0131<\/td>\n<td>Kabloya monte edilmi\u015f g\u00f6vdedeki di\u015fi kontak aray\u00fcz\u00fc<\/td>\n<td><a href=\"https:\/\/yocl.com\/tr\/product\/ip44-industrial-cable-couplers\/\">IP44 end\u00fcstriyel kablo kuplajlar\u0131<\/a><\/td>\n<\/tr>\n<tr>\n<td>Sabit priz<\/td>\n<td>Sabit bir besleme noktas\u0131nda kurulu di\u015fi aray\u00fcz; panel ve y\u00fczey montaj\u0131 ayr\u0131 formatlard\u0131r<\/td>\n<td><a href=\"https:\/\/yocl.com\/tr\/product\/ip44-angled-panel-sockets\/\">IP44 a\u00e7\u0131l\u0131 panel prizleri<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/industrial-plugs-sockets-explained-connection-formats.webp\" alt=\"End\u00fcstriyel erkek kablo fi\u015fi, di\u015fi kablo konekt\u00f6r\u00fc ve flan\u015fa monte sabit priz farkl\u0131 formatlarda g\u00f6sterilmi\u015ftir\"><figcaption>D\u0131\u015f aile \u00e7izimleri, kontak aray\u00fcz\u00fcn\u00fc ve montaj format\u0131n\u0131 ay\u0131rt eder. Resimdeki bile\u015fenler onaylanm\u0131\u015f bir e\u015fle\u015fme \u00e7ifti spesifikasyonu de\u011fildir.<\/figcaption><\/figure>\n<p>Bir <strong>cihaz giri\u015fi<\/strong> ekipmana monte bir giri\u015f aray\u00fcz\u00fcd\u00fcr. Her ikisi de erkek kontaklar kullansa bile, bir kablo fi\u015finden farkl\u0131 bir montaj rol\u00fcne sahiptir. Katalog kodlar\u0131n\u0131 kar\u015f\u0131la\u015ft\u0131rmadan \u00f6nce bile\u015fenin ba\u011flant\u0131daki yerini belirleyin.<\/p>\n<p>Tek kutuplu Kam-Kilit konekt\u00f6rler, <a href=\"https:\/\/yocl.com\/tr\/industrial-plugs-sockets-manufacturer\/#range\">YOCL end\u00fcstriyel ba\u011flant\u0131 serisinde<\/a>. ayr\u0131 bir dald\u0131r. Bunlar, \u00e7ok kutuplu saat konumu referans\u0131 arac\u0131l\u0131\u011f\u0131yla de\u011fil, kendi \u00fcr\u00fcn bilgileri arac\u0131l\u0131\u011f\u0131yla de\u011ferlendirilmelidir.<\/p>\n<h2>2P+E, 3P+E ve 3P+N+E ne anlama gelir<\/h2>\n<p>Bu tan\u0131mlamalar kontak fonksiyonlar\u0131n\u0131 a\u00e7\u0131klar. <strong>E<\/strong> koruyucu topraklama demektir; <strong>N<\/strong> n\u00f6trd\u00fcr. 3P+N+E i\u00e7indeki ek n\u00f6tr konta\u011f\u0131, ekipmana sa\u011flanan devre ba\u011flant\u0131s\u0131n\u0131 de\u011fi\u015ftirir.<\/p>\n<table>\n<thead>\n<tr>\n<th>D\u00fczenleme<\/th>\n<th align=\"right\">Toplam kontak say\u0131s\u0131<\/th>\n<th>Yorumlama<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>2P+E<\/strong><\/td>\n<td align=\"right\">3<\/td>\n<td>\u0130ki ak\u0131m ta\u015f\u0131yan kutup art\u0131 koruyucu toprak. Faz-n\u00f6tr uygulamas\u0131nda bunlar faz, n\u00f6tr ve toprak i\u015flevi g\u00f6r\u00fcr; besleme konfig\u00fcrasyonu yine de teyit edilmelidir.<\/td>\n<\/tr>\n<tr>\n<td><strong>3P+E<\/strong><\/td>\n<td align=\"right\">4<\/td>\n<td>\u00dc\u00e7 faz konta\u011f\u0131 art\u0131 koruyucu toprak, \u00f6zel bir n\u00f6tr konta\u011f\u0131 yoktur.<\/td>\n<\/tr>\n<tr>\n<td><strong>3P+N+E<\/strong><\/td>\n<td align=\"right\">5<\/td>\n<td>\u00dc\u00e7 fazl\u0131 kontaklar, ayr\u0131 bir n\u00f6tr konta\u011f\u0131 ve koruyucu topraklama.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>YOCL end\u00fcstriyel fi\u015f katalo\u011fu bu \u00fc\u00e7 d\u00fczenlemeyi listeler. Yukar\u0131daki kontak say\u0131s\u0131 a\u00e7\u0131klamas\u0131, bunlar\u0131n g\u00f6sterimini yorumlar; bu bir terminal konumu veya kablolama \u015femas\u0131 de\u011fildir. <a href=\"https:\/\/yocl.com\/tr\/product\/ip44-industrial-plugs\/\">YOCL \u00fcr\u00fcn bilgisi<\/a>.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/industrial-plugs-sockets-explained-pole-functions.webp\" alt=\"N\u00f6tr\u00fcn koruyucu topraktan ayr\u0131 oldu\u011fu 2P+E, 3P+E ve 3P+N+E say\u0131mlar\u0131n\u0131 g\u00f6steren kavramsal kontak gruplar\u0131\"><figcaption>Sadece kontak fonksiyonlar\u0131 ve say\u0131lar\u0131d\u0131r. Konumlar kavramsal olup bir konnekt\u00f6r\u00fcn kablolanmas\u0131 i\u00e7in kullan\u0131lmamal\u0131d\u0131r.<\/figcaption><\/figure>\n<p>N\u00f6tr gerektiren \u00fc\u00e7 fazl\u0131 bir y\u00fck\u00fcn, bu fonksiyonunun a\u00e7\u0131k\u00e7a dikkate al\u0131nmas\u0131 gerekir. D\u00f6rt kontakl\u0131 bir 3P+E tan\u0131m\u0131, ayr\u0131 bir n\u00f6tr konta\u011f\u0131 sa\u011flamaz. Koruyucu topraklama ve n\u00f6tr farkl\u0131 fonksiyonlar olarak kal\u0131r; topraklama konta\u011f\u0131, eksik bir n\u00f6tr\u00fc tamamlamak i\u00e7in ba\u015fka bir ama\u00e7la kullan\u0131lmamal\u0131d\u0131r.<\/p>\n<h2>Kodlama ve renk, aray\u00fcz\u00fcn farkl\u0131 k\u0131s\u0131mlar\u0131n\u0131 tan\u0131mlar<\/h2>\n<p><strong>Kodlama<\/strong> e\u015fle\u015fmeyi se\u00e7ici hale getiren fiziksel desendir. Kontak d\u00fczeni, referans \u00f6zellikleri ve konnekt\u00f6r boyutu eksiksiz bir aray\u00fcz olarak kontrol edilmelidir. Muhafaza rengi g\u00f6r\u00fcn\u00fcr bir tan\u0131mlama ipucudur; tam bir e\u015fle\u015fme spesifikasyonu de\u011fildir.<\/p>\n<p>YOCL model tablolar\u0131, a\u015fa\u011f\u0131dakiler gibi giri\u015flere sahip bir saat konumu alan\u0131 i\u00e7erir: <strong>6h<\/strong>. \u00dcr\u00fcnle birlikte verilen <a href=\"https:\/\/yocl.com\/tr\/industrial-plugs-sockets-manufacturer\/#clock-reference\">saat konumu referans\u0131<\/a> bir <strong>priz \u00f6n g\u00f6r\u00fcn\u00fcm\u00fc<\/strong> olarak etiketlenmi\u015ftir ve aray\u00fcz tan\u0131mlay\u0131c\u0131s\u0131 olarak toprak konta\u011f\u0131 konumunu kullan\u0131r. Bu g\u00f6r\u00fcn\u00fcm\u00fc ve se\u00e7ilen modelin i\u015faretlerini birlikte okuyun. Bu, arka terminal \u015femas\u0131 de\u011fildir.<\/p>\n<p>\u0130ki katalog giri\u015fi, kutup, voltaj veya ak\u0131m boyutu bak\u0131m\u0131ndan farkl\u0131l\u0131k g\u00f6sterirken ayn\u0131 saat i\u015faretini payla\u015fabilir. Par\u00e7alar\u0131 bir \u00e7ift olarak de\u011ferlendirmeden \u00f6nce, her iki tam model referans\u0131n\u0131, kontak d\u00fczenlerini, nominal voltaj ve frekanslar\u0131n\u0131, ak\u0131m de\u011ferlerini ve belgelenmi\u015f e\u015fle\u015fme geometrilerini do\u011frulay\u0131n. G\u00f6r\u00fcn\u00fc\u015f\u00fcn e\u015fle\u015fmesi, bu kontrollerin yap\u0131lmas\u0131 gereklili\u011fini ortadan kald\u0131rmaz.<\/p>\n<h2>De\u011fer alanlar\u0131n\u0131 ayr\u0131 kan\u0131tlar olarak okuyun<\/h2>\n<p>Her de\u011fer, belirli bir soruyu yan\u0131tlar. Farkl\u0131 katalog sat\u0131rlar\u0131ndaki ilgisiz de\u011ferleri birle\u015ftirmek, ger\u00e7ek bir \u00fcr\u00fcn\u00fc tan\u0131mlamayan bir \u00f6zellik olu\u015fturabilir.<\/p>\n<table>\n<thead>\n<tr>\n<th>Alan<\/th>\n<th>Size ne anlat\u0131r<\/th>\n<th>Hala kontrol edilmesi gerekenler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Anma ak\u0131m\u0131, amper (A) olarak<\/td>\n<td>Bu aksesuar i\u00e7in beyan edilen ak\u0131m de\u011feri<\/td>\n<td>Y\u00fck, kablo ve devre koruma gereksinimleri; bir konekt\u00f6r de\u011feri, bir devre tasar\u0131m\u0131 hesaplamas\u0131 de\u011fildir<\/td>\n<\/tr>\n<tr>\n<td>Anma gerilimi ve frekans\u0131<\/td>\n<td>Belirtilen elektriksel \u00e7al\u0131\u015fma yap\u0131land\u0131rmas\u0131<\/td>\n<td>Ger\u00e7ek besleme ve ekipman gereksinimleri; frekans yaln\u0131zca renkten doldurulamaz<\/td>\n<\/tr>\n<tr>\n<td>Kutuplar ve saat i\u015faretlemesi<\/td>\n<td>Listelenen kontak konfig\u00fcrasyonu ve aray\u00fcz tan\u0131mlay\u0131c\u0131s\u0131<\/td>\n<td>Tam e\u015fle\u015fen \u00e7ift ve do\u011fru \u00e7izim\/g\u00f6r\u00fcn\u00fcm<\/td>\n<\/tr>\n<tr>\n<td>Giri\u015f korumas\u0131 (IP) kodu<\/td>\n<td>Kat\u0131 nesne eri\u015fimine\/giri\u015fine ve suya giri\u015fe kar\u015f\u0131 bir koruma s\u0131n\u0131fland\u0131rmas\u0131<\/td>\n<td>Belgelenmi\u015f montaj durumu, contalar, giri\u015fler ve maruz kalma ko\u015fullar\u0131<\/td>\n<\/tr>\n<tr>\n<td>\u0130letken kapasitesi<\/td>\n<td>Belirtilen terminallerin kabul etti\u011fi iletken boyutlar\u0131<\/td>\n<td>\u0130letken tipi, sonland\u0131rma talimatlar\u0131 ve ayr\u0131 kablo k\u0131l\u0131f\u0131 \u00e7ap\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>IP44 ve IP67 farkl\u0131 koruma kategorilerini belirtir<\/h3>\n<p>IP kodu ayr\u0131 kat\u0131\/eri\u015fim ve su rakamlar\u0131na sahiptir. UL'in a\u00e7\u0131klay\u0131c\u0131 IP tablosu a\u015fa\u011f\u0131daki s\u0131n\u0131rl\u0131 anlamlar\u0131 vermektedir. <a href=\"https:\/\/code-authorities.ul.com\/wp-content\/uploads\/2014\/09\/UL-White-Book.pdf#page=52\" target=\"_blank\" rel=\"noopener\">UL Beyaz Kitap, 2015\u201316, s. 52<\/a>.<\/p>\n<table>\n<thead>\n<tr>\n<th>Kod<\/th>\n<th>Kat\u0131\/eri\u015fim kategorisi<\/th>\n<th>Su kategorisi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>IP44<\/strong><\/td>\n<td>1.0 mm \u00e7ap\u0131ndaki ve daha b\u00fcy\u00fck nesnelere kar\u015f\u0131 koruma<\/td>\n<td>S\u0131\u00e7rayan su<\/td>\n<\/tr>\n<tr>\n<td><strong>IP67<\/strong><\/td>\n<td>Toz ge\u00e7irmez kategori<\/td>\n<td>Ge\u00e7ici dald\u0131rma<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Bunlar, belirli bir YOCL modelinin ba\u011f\u0131ms\u0131z olarak sertifikaland\u0131r\u0131ld\u0131\u011f\u0131na dair kan\u0131t de\u011fil, kod anlamlar\u0131d\u0131r. Dald\u0131rma kategorisi de tek ba\u015f\u0131na su jeti derecesini belirlemez.<\/p>\n<p>Ger\u00e7ek bir fi\u015f\/priz tertibat\u0131 i\u00e7in, beyan edilen derecelendirmenin hangi durumda ge\u00e7erli oldu\u011funu sorun: ba\u011fl\u0131, kapakl\u0131 olarak ayr\u0131lm\u0131\u015f veya belgelenmi\u015f ba\u015fka bir durum. Mevcut katalog \u00f6zeti tek ba\u015f\u0131na her durumu \u00e7\u00f6zmez. Koruma kodu ayr\u0131ca kimyasal dirence, \u00e7al\u0131\u015fma s\u0131cakl\u0131\u011f\u0131na veya tehlikeli alan uygunlu\u011funa da sahip de\u011fildir.<\/p>\n<h2>\u0130ki YOCL katalog \u00f6rne\u011fi<\/h2>\n<p>A\u015fa\u011f\u0131daki giri\u015fler mevcut <a href=\"https:\/\/yocl.com\/tr\/product\/ip44-industrial-plugs\/\">YOCL IP44 end\u00fcstriyel fi\u015f tablosundan<\/a>. Bunlar beyan edilmi\u015f \u00fcr\u00fcn bilgileridir, ba\u011f\u0131ms\u0131z olarak do\u011frulanm\u0131\u015f test sonu\u00e7lar\u0131 de\u011fildir.<\/p>\n<table>\n<thead>\n<tr>\n<th>Katalog modeli<\/th>\n<th>Ak\u0131m<\/th>\n<th>D\u00fczenleme<\/th>\n<th>Listelenen voltaj<\/th>\n<th>Saat i\u015faretleme<\/th>\n<th>Listelenen koruma<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>NM-013H<\/strong><\/td>\n<td>16 A<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td><strong>NM-024H<\/strong><\/td>\n<td>32 A<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>IP44<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Her iki giri\u015f de 6s ve IP44 g\u00f6steriyor, ancak farkl\u0131 ak\u0131m de\u011ferlerini, kontak d\u00fczenlemelerini ve voltajlar\u0131 tan\u0131ml\u0131yorlar. Payla\u015f\u0131lan hi\u00e7bir alan onlar\u0131 ikame yapmaz. Tam frekanslar\u0131 ve e\u015fle\u015fen kar\u015f\u0131l\u0131klar\u0131 hala do\u011frulanmal\u0131; genel se\u00e7ici, frekans\u0131 a\u00e7\u0131k\u00e7a teklif onay\u0131na b\u0131rak\u0131yor.<\/p>\n<p>Bu makaledeki \u00e7izimler \u00fcr\u00fcn ailelerini g\u00f6stermektedir. Ne tam bir NM modelini tan\u0131mlarlar ne de onaylanm\u0131\u015f bir e\u015fle\u015fme kombinasyonu olu\u015ftururlar.<\/p>\n<h2>Bir sonraki sorunuzu yan\u0131tlayan kayna\u011f\u0131 bulun<\/h2>\n<table>\n<thead>\n<tr>\n<th>Kalan sorunuz<\/th>\n<th>Nereden devam etmeli<\/th>\n<th>Ne elde etmeli<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Gerekli elektrik alanlar\u0131na uyan tam model hangisidir?<\/td>\n<td><a href=\"https:\/\/yocl.com\/tr\/industrial-plugs-sockets-manufacturer\/#industrial-selector\">YOCL end\u00fcstriyel model se\u00e7ici<\/a><\/td>\n<td>Aday bir model, ard\u0131ndan frekans\u0131n\u0131n ve e\u015fle\u015fen muadilinin onay\u0131<\/td>\n<\/tr>\n<tr>\n<td>Saat y\u00f6n\u00fc g\u00f6r\u00fcn\u00fcm\u00fc nas\u0131l okunmal\u0131d\u0131r?<\/td>\n<td><a href=\"https:\/\/yocl.com\/tr\/industrial-plugs-sockets-manufacturer\/#clock-reference\">Sa\u011flanan soket \u00f6n g\u00f6r\u00fcn\u00fcm referans\u0131<\/a><\/td>\n<td>Uygulanabilir yap\u0131land\u0131rma ve e\u015fle\u015fen model belgeleri<\/td>\n<\/tr>\n<tr>\n<td>Hangi kablo giri\u015f boyutu \u00f6nemlidir?<\/td>\n<td><a href=\"https:\/\/yocl.com\/tr\/how-to-choose-a-cable-gland\/\">Kablo \u00e7ap\u0131 ve giri\u015f se\u00e7imi<\/a><\/td>\n<td>K\u0131l\u0131f d\u0131\u015f \u00e7ap\u0131 ile iletken alan\u0131 aras\u0131ndaki fark; konekt\u00f6r\u00fcn kendi giri\u015f talimatlar\u0131n\u0131 kullan\u0131n<\/td>\n<\/tr>\n<tr>\n<td>Panel soketi ekipman y\u00fcz\u00fcne uyar m\u0131?<\/td>\n<td><a href=\"https:\/\/yocl.com\/tr\/product\/ip44-angled-panel-sockets\/\">A\u00e7\u0131l\u0131 panel soketi \u00e7izimleri<\/a><\/td>\n<td>Se\u00e7ilen muhafazan\u0131n montaj boyutlar\u0131 ve muhafaza aray\u00fcz\u00fc gereksinimleri<\/td>\n<\/tr>\n<tr>\n<td>Hangi par\u00e7alar ve \u00fcr\u00fcn belgeleri aileye aittir?<\/td>\n<td><a href=\"https:\/\/yocl.com\/tr\/industrial-plugs-sockets-manufacturer\/#series\">YOCL end\u00fcstriyel fi\u015f ve priz serisi<\/a><\/td>\n<td>Do\u011fru fi\u015f, giri\u015f, sabit priz veya kablo konekt\u00f6r\u00fc ba\u011flant\u0131s\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Tam ba\u011flant\u0131 gereksinimi ve aray\u00fcz\u00fcn her iki taraf\u0131yla ba\u015flay\u0131n. Katalog de\u011ferlendirmesi i\u00e7in bile\u015fen format\u0131n\u0131, besleme voltaj\u0131n\u0131 ve frekans\u0131n\u0131, gerekli kontak fonksiyonlar\u0131n\u0131, ak\u0131m de\u011ferini, ortam\u0131 ve mevcut e\u015fle\u015fen par\u00e7a referans\u0131n\u0131 kaydedin. Bu girdiler, bir \u00fcr\u00fcn genel bak\u0131\u015f\u0131n\u0131 bir kurulum prosed\u00fcr\u00fcne d\u00f6n\u00fc\u015ft\u00fcrmeden model tart\u0131\u015fmas\u0131n\u0131 \u00f6zelle\u015ftirir.<\/p>\n<h2>Referanslar<\/h2>\n<ul>\n<li>IEC. <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/59916\" target=\"_blank\" rel=\"noopener\">IEC 60309-1:2021 \u2014 B\u00f6l\u00fcm 1: Genel gereksinimler<\/a>, Bask\u0131 5.0; May\u0131s 2023 d\u00fczeltmesi dahil resmi katalog \u00f6zeti ve kamu \u00f6nizlemesi. Standart kapsam i\u00e7in kullan\u0131l\u0131r.<\/li>\n<li>IEC. <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/59919\" target=\"_blank\" rel=\"noopener\">IEC 60309-2:2021 \u2014 Par\u00e7a 2: Pim ve kontak t\u00fcp\u00fc aksesuarlar\u0131 i\u00e7in boyutsal uyumluluk gereksinimleri<\/a>, Bask\u0131 5.0, d\u00fczeltilmi\u015f s\u00fcr\u00fcm 2026-08; resmi katalog \u00f6zeti ve genel \u00f6nizleme. Standart kapsam i\u00e7in kullan\u0131l\u0131r.<\/li>\n<li>YOCL ELEKTR\u0130K. <a href=\"https:\/\/yocl.com\/tr\/product\/ip44-industrial-plugs\/\">IP44 end\u00fcstriyel fi\u015fler<\/a>. Birinci taraf \u00fcr\u00fcn bilgileri, model tablosu ve d\u0131\u015f g\u00f6r\u00fcn\u00fcm referans\u0131; 8 Ekim 2026 tarihinde eri\u015fildi.<\/li>\n<li>YOCL ELEKTR\u0130K. <a href=\"https:\/\/yocl.com\/tr\/product\/ip44-industrial-cable-couplers\/\">IP44 end\u00fcstriyel kablo kuplajlar\u0131<\/a>. Birinci taraf \u00fcr\u00fcn bilgileri ve d\u0131\u015f g\u00f6r\u00fcn\u00fcm referans\u0131; 8 Ekim 2026 tarihinde eri\u015fildi.<\/li>\n<li>YOCL ELEKTR\u0130K. <a href=\"https:\/\/yocl.com\/tr\/product\/ip44-angled-panel-sockets\/\">IP44 a\u00e7\u0131l\u0131 panel prizleri<\/a>. Birinci taraf \u00fcr\u00fcn bilgileri, \u00e7izimler ve d\u0131\u015f g\u00f6r\u00fcn\u00fcm referans\u0131; 8 Ekim 2026 tarihinde eri\u015fildi.<\/li>\n<li>YOCL ELEKTR\u0130K. <a href=\"https:\/\/yocl.com\/tr\/industrial-plugs-sockets-manufacturer\/\">End\u00fcstriyel fi\u015f ve priz \u00fcreticisi sayfas\u0131<\/a>, tedarik edilen saat konumu referans\u0131, \u00fcr\u00fcn dallar\u0131 ve genel model se\u00e7ici. Birinci taraf \u00fcr\u00fcn bilgileri; 8 Ekim 2026 tarihinde eri\u015fildi.<\/li>\n<li>UL. <a href=\"https:\/\/code-authorities.ul.com\/wp-content\/uploads\/2014\/09\/UL-White-Book.pdf#page=52\" target=\"_blank\" rel=\"noopener\">2015\u201316 Elektrik Ekipmanlar\u0131 \u0130\u00e7in K\u0131lavuz Bilgileri \u2014 Beyaz Kitap<\/a>, s. 52, IP kodlu a\u00e7\u0131klay\u0131c\u0131 tablo. Kod anlamlar\u0131 i\u00e7in kullan\u0131l\u0131r, mevcut kurulum yasas\u0131 veya YOCL sertifikas\u0131 i\u00e7in de\u011fil.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Industrial plugs and sockets provide a detachable power connection between a supply and equipment. A matching pair is defined by its physical interface and electrical configuration: pole arrangement, voltage and frequency, current rating, keying and the declared protection conditions. Colour or amperage alone leaves important parts of that specification unresolved. The IEC 60309 family distinguishes [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3008,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[178],"tags":[],"class_list":["post-3009","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industrial-plugs-sockets"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/3009","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/comments?post=3009"}],"version-history":[{"count":1,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/3009\/revisions"}],"predecessor-version":[{"id":3010,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/3009\/revisions\/3010"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/3008"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=3009"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/categories?post=3009"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/tags?post=3009"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}