{"id":3151,"date":"2026-10-11T05:38:51","date_gmt":"2026-10-11T05:38:51","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=e9e8de38c5c8bb0bb3347a765e01e8cc166de3740df591e8031d29ed7bfd9cfe"},"modified":"2026-10-11T05:38:51","modified_gmt":"2026-10-11T05:38:51","slug":"how-to-select-and-apply-heat-shrink-tubing-to-a-cable-splice","status":"publish","type":"post","link":"https:\/\/yocl.com\/tr\/how-to-select-and-apply-heat-shrink-tubing-to-a-cable-splice\/","title":{"rendered":"Bir Kablo Birle\u015ftirme Yerine Is\u0131yla Daralan Makaron Nas\u0131l Se\u00e7ilir ve Uygulan\u0131r"},"content":{"rendered":"<p>En b\u00fcy\u00fck ek par\u00e7as\u0131n\u0131n \u00fczerinden ge\u00e7ebilen, en k\u00fc\u00e7\u00fck oturma \u00e7ap\u0131n\u0131n alt\u0131nda daralan ve daralma sonras\u0131 gerekli kapsama alan\u0131n\u0131 koruyan \u0131s\u0131yla daralan makaron se\u00e7in. Ba\u011flant\u0131y\u0131 kapatmadan \u00f6nce kesin ve \u00f6nceden y\u00fckleyin, elektriksel ba\u011flant\u0131y\u0131 kabul edin, makaronu konumland\u0131r\u0131n, belirtilen \u0131s\u0131tma i\u015flemiyle daralt\u0131n, ard\u0131ndan so\u011futun, inceleyin ve gerekli montaj testlerini tamamlay\u0131n.<\/p>\n<p>Bu prosed\u00fcr, belirtilen d\u00fcz hat ek yerini kapsar. <a href=\"https:\/\/yocl.com\/tr\/what-is-heat-shrink-tubing\/\">Is\u0131yla daralan makaron<\/a> belirtilen yal\u0131t\u0131m\u0131 veya korumay\u0131 sa\u011flar; elektriksel ba\u011flant\u0131y\u0131 yapmaz. Korumal\u0131, \u00e7ok damarl\u0131 ve orta veya y\u00fcksek voltajl\u0131 ek yerleri kendi montaj talimatlar\u0131na ihtiya\u00e7 duyar. S\u0131k\u0131ca daralm\u0131\u015f bir makaron, bir ek yerinin elektriksel olarak kabul edilebilir veya \u00e7evresel olarak s\u0131zd\u0131rmaz oldu\u011funun kan\u0131t\u0131 de\u011fildir.<\/p>\n<h2>1. \u0130\u015f talimatlar\u0131n\u0131 ve izolasyonu onaylay\u0131n<\/h2>\n<p>Kabloyu kesmeden veya \u0131s\u0131 uygulamadan \u00f6nce, ek \u00e7izimini, birle\u015ftirme talimatlar\u0131n\u0131, kesin makaron verilerini, uygulama s\u00fcrecini ve kabul gereksinimlerini al\u0131n. Ekipman ve saha prosed\u00fcr\u00fcne g\u00f6re enerjisiz oldu\u011fu do\u011frulanm\u0131\u015f izole edilmi\u015f bir devre \u00fczerinde \u00e7al\u0131\u015f\u0131n. U.S. i\u015f yerlerinde, <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.333\" target=\"_blank\" rel=\"noopener\">OSHA 1910.333(b)<\/a> kilitleme\/etiketleme ve yetkili bir ki\u015fi taraf\u0131ndan do\u011frulama i\u015flemlerini belirler.<\/p>\n<p>\u00d6l\u00e7\u00fcmleri nihai kabul karar\u0131na ba\u011flamak i\u00e7in bir i\u015f kayd\u0131 kullan\u0131n:<\/p>\n<table>\n<thead>\n<tr>\n<th>Ba\u015flamadan \u00f6nce kay\u0131t<\/th>\n<th>Kontrol etti\u011fi karar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Kablo\/k\u0131l\u0131f, ek yeri ve man\u015fon tan\u0131mlamas\u0131<\/td>\n<td>Malzeme uyumlulu\u011fu ve ge\u00e7erli talimatlar<\/td>\n<\/tr>\n<tr>\n<td>Man\u015fonun yerle\u015ftirme yolundaki en b\u00fcy\u00fck \u00f6zellik<\/td>\n<td>Gerekli sa\u011flanan i\u00e7 \u00e7ap<\/td>\n<\/tr>\n<tr>\n<td>Sol ve sa\u011f ini\u015f d\u0131\u015f \u00e7aplar\u0131<\/td>\n<td>Her iki tarafta gerekli geri kazan\u0131m<\/td>\n<\/tr>\n<tr>\n<td>Her iki tarafta ek yeri a\u00e7\u0131kl\u0131\u011f\u0131 ve belirtilen bindirme<\/td>\n<td>Minimum bitmi\u015f kapsama alan\u0131<\/td>\n<\/tr>\n<tr>\n<td>Elektriksel g\u00f6rev, ortam ve mevcut alan<\/td>\n<td>Yap\u0131, duvar ve montaj uygunlu\u011fu<\/td>\n<\/tr>\n<tr>\n<td>Is\u0131tma, so\u011futma ve kabul talimatlar\u0131<\/td>\n<td>\u0130\u015flem limitleri ve serbest b\u0131rakma kontrolleri<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Uygun \u00f6l\u00e7\u00fcm aletlerine, bir kesiciye, belirtilen birle\u015ftirme aletlerine ve izin verilen kontroll\u00fc bir \u0131s\u0131 kayna\u011f\u0131na sahip olun. <strong>Gerekli bir talimat veya kabul kriteri eksikse i\u015fi durdurun.<\/strong><\/p>\n<h2>2. Yap\u0131y\u0131 se\u00e7in ve her iki \u00e7ap\u0131 da kontrol edin<\/h2>\n<p>Belirtilen g\u00f6rev i\u00e7in yap\u0131y\u0131 se\u00e7in. <a href=\"https:\/\/yocl.com\/tr\/heat-shrink-tubing-manufacturer\/\">YOCL\u2019\u0131n \u0131s\u0131yla daralan makaron serisi<\/a> tek cidarl\u0131 HTS makaronlar\u0131 ve HS3X\/HS4X yap\u0131\u015fkan astarl\u0131 makaronlar\u0131 i\u00e7erir. Astars\u0131z bir k\u0131l\u0131f, yal\u0131t\u0131m\/koruma gereksinimi i\u00e7in kullan\u0131labilir; yap\u0131\u015fkan astarl\u0131 bir k\u0131l\u0131f, s\u0131zd\u0131rmazl\u0131k gerekti\u011finde uyumlu bir ceket aray\u00fcz\u00fc ve do\u011frulanm\u0131\u015f bir uygulama s\u00fcreci gerektirir. Kullan\u0131n <a href=\"https:\/\/yocl.com\/tr\/single-wall-vs-dual-wall-heat-shrink-tubing\/\">tek cidarl\u0131 ve \u00e7ift cidarl\u0131 k\u0131lavuzu<\/a> bu karar \u00e7\u00f6z\u00fclmezse.<\/p>\n<p>Makaronun ge\u00e7mesi gereken herhangi bir konekt\u00f6r omzunu da i\u00e7eren tam yerle\u015ftirme yolunu \u00f6l\u00e7\u00fcn. \u0130ni\u015f \u00e7aplar\u0131n\u0131n her ikisini de ayr\u0131 ayr\u0131 kaydedin; iletken kesit alan\u0131 bir ceket \u00e7ap\u0131 de\u011fildir. Sa\u011flanan minimum i\u00e7 \u00e7ap\u0131 en b\u00fcy\u00fck ge\u00e7i\u015f \u00f6zelli\u011fine kar\u015f\u0131 ve kurtar\u0131lan maksimum i\u00e7 \u00e7ap\u0131 en k\u00fc\u00e7\u00fck ini\u015fe kar\u015f\u0131 kontrol edin.<\/p>\n<p>Daha b\u00fcy\u00fck \u00f6nce\/daha k\u00fc\u00e7\u00fck sonra prensibi \u015furada g\u00f6r\u00fcn\u00fcr <a href=\"https:\/\/standards.nasa.gov\/sites\/default\/files\/standards\/KSC\/F\/KSC-E-165-REV-F.pdf\" target=\"_blank\" rel=\"noopener\">KSC-E-165 Revizyon F, \u00a73.8.1.1.1(a)<\/a>, KSC yer destek kontrol ve izleme ekipmanlar\u0131 i\u00e7in bir spesifikasyondur. Bu, evrensel bir kurulum pay\u0131 de\u011fil, bu boyutsal ekran\u0131 destekler.<\/p>\n<p>\u00d6rne\u011fin, bir <strong>7.4 mm<\/strong> en b\u00fcy\u00fck ge\u00e7i\u015f \u00f6zelli\u011fi ve bir <strong>4.0 mm<\/strong> en k\u00fc\u00e7\u00fck ini\u015f varsayal\u0131m. Mevcut <a href=\"https:\/\/yocl.com\/tr\/product\/hs3x-3-1-dual-wall-adhesive-lined-heat-shrink-tubing\/\">YOCL HS3X tablosu<\/a> \u015funu verir:<\/p>\n<table>\n<thead>\n<tr>\n<th>HS3X nominal boyut<\/th>\n<th align=\"right\">Tedarik edilen i\u00e7 \u00e7ap<\/th>\n<th align=\"right\">Daralm\u0131\u015f i\u00e7 \u00e7ap<\/th>\n<th>\u00d6n sonu\u00e7<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>6.4 mm<\/td>\n<td align=\"right\">\u22656.4 mm<\/td>\n<td align=\"right\">\u22642.2 mm<\/td>\n<td>Garanti edilen tedarik edilen minimum de\u011fer 7.4 mm de\u011ferini ge\u00e7miyor<\/td>\n<\/tr>\n<tr>\n<td>9.5 mm<\/td>\n<td align=\"right\">\u22659.5 mm<\/td>\n<td align=\"right\">\u22643.2 mm<\/td>\n<td>Her iki temel \u00e7ap kontrol\u00fcn\u00fc de ge\u00e7er<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>9.5 mm sat\u0131r\u0131 bir <strong>boyutsal adayd\u0131r<\/strong>, onayl\u0131 bir s\u0131zd\u0131rmaz ek de\u011fildir. Gerekli yerle\u015ftirme pay\u0131n\u0131, toleranslar\u0131, duvar\/bo\u015fluk, g\u00f6rev ve k\u0131l\u0131f uyumlulu\u011funu do\u011frulay\u0131n. \u015euna ba\u015fvurun: <a href=\"https:\/\/yocl.com\/tr\/heat-shrink-tubing-size-chart\/\">boyut tablosu<\/a> di\u011fer sat\u0131rlar i\u00e7in; \u015funu kullan\u0131n: <a href=\"https:\/\/yocl.com\/tr\/2-1-vs-3-1-vs-4-1-heat-shrink-tubing\/\">b\u00fcz\u00fclme oran\u0131 kar\u015f\u0131la\u015ft\u0131rmas\u0131<\/a> ge\u00e7i\u015f ve ini\u015f geometrisi ba\u015fka bir oran gerektirdi\u011finde.<\/p>\n<figure class=\"wp-block-image\">\n  <img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/how-to-select-and-apply-heat-shrink-tubing-to-a-cable-splice-measurement.webp\" alt=\"Conceptual splice showing the largest pass-over feature, both jacket landings and required sleeve coverage\"><figcaption>Ge\u00e7i\u015fi, her iki ini\u015fi ve bitmi\u015f kaplamay\u0131 ayr\u0131 ayr\u0131 \u00f6l\u00e7\u00fcn. \u00d6rt\u00fc\u015fme, uygulama \u00e7iziminden gelir.<\/figcaption><\/figure>\n<h2>3. Kesim uzunlu\u011funu belirleyin ve makaronu \u00f6n y\u00fcklemeye tabi tutun<\/h2>\n<p>Tamamlanm\u0131\u015f kaplama, ek a\u00e7\u0131kl\u0131\u011f\u0131n\u0131 ve her iki tarafta belirtilen bindirme pay\u0131n\u0131 i\u00e7ermelidir. Ge\u00e7erli i\u015flem verilerini kullanarak boyuna de\u011fi\u015fimi hesaba kat\u0131n. Belirlenmi\u015f bir montaj pay\u0131 yerine rastgele bir ekstra uzunluk y\u00fczdesi veya laboratuvar eksenel de\u011fi\u015fim de\u011feri kullanmay\u0131n.<\/p>\n<p>Talimatlar\u0131n maksimum k\u0131salma oran\u0131n\u0131 belirledi\u011fi durumlarda <strong>s<\/strong>, planlama hesaplamas\u0131 \u015f\u00f6yledir:<\/p>\n<p><strong>Minimum kesim uzunlu\u011fu = (ek a\u00e7\u0131kl\u0131\u011f\u0131 + sol bindirme + sa\u011f bindirme) \u00f7 (1 \u2212 s)<\/strong><\/p>\n<p>Belirtilen bindirme pay\u0131n\u0131 ve do\u011frulanm\u0131\u015f <strong>s<\/strong> de\u011ferleri kullan\u0131n, izin verilen kesim uzunlu\u011funa yuvarlay\u0131n ve so\u011fuduktan sonra ger\u00e7ek kaplamay\u0131 do\u011frulay\u0131n. Bu girdiler bilinmiyorsa, hesaplama makaronun kesilmesi i\u00e7in onay veremez.<\/p>\n<p>YOCL\u2019n\u0131n <a href=\"https:\/\/yocl.com\/tr\/product\/hts-2-1-single-wall-heat-shrink-tubing\/\">HTS montaj notlar\u0131<\/a> Gerekirse ba\u011flant\u0131 tamamlanmadan \u00f6nce gerekli uzunlukta do\u011frudan kesme ve boruyu \u00fczerine kayd\u0131rma. Eri\u015fim varken se\u00e7ilen k\u0131l\u0131f\u0131 \u00f6nceden y\u00fckleyin. Birle\u015ftirme talimatlar\u0131 uyar\u0131nca, birle\u015ftirme alan\u0131n\u0131n d\u0131\u015f\u0131nda park edin.<\/p>\n<p>Eri\u015fim \u00f6n y\u00fckleme yap\u0131lmadan kapat\u0131lm\u0131\u015fsa, onaylanm\u0131\u015f bir d\u00fczeltme i\u00e7in durun; standart kapal\u0131 bir t\u00fcp\u00fc yarmak onu onaylanm\u0131\u015f bir sarmal\u0131 k\u0131l\u0131f yapmaz.<\/p>\n<h2>4. Ba\u011flant\u0131y\u0131 kapatmadan \u00f6nce tamamlay\u0131n ve kabul edin<\/h2>\n<p>Eklemi, belirtilen konekt\u00f6r\u00fc, iletken kombinasyonunu ve birle\u015ftirme prosed\u00fcr\u00fcn\u00fc kullanarak yap\u0131n. K\u0131l\u0131f ek yeri gizlemeden \u00f6nce gerekli ba\u011flant\u0131 denetimini tamamlay\u0131n. Ba\u015far\u0131s\u0131z veya belgelenmemi\u015f bir ba\u011flant\u0131, boru uysa bile beklemeye al\u0131n\u0131r.<\/p>\n<p>Y\u00fczeyleri, se\u00e7ilen ceket, k\u0131l\u0131f ve yap\u0131\u015ft\u0131r\u0131c\u0131 talimatlar\u0131na g\u00f6re haz\u0131rlay\u0131n. Temizleme, astarlama veya kurutma gerektiriyorlarsa, bu malzeme \u00f6zelindeki talimatlar\u0131 izleyin. Bir \u00e7\u00f6z\u00fcc\u00fc veya a\u015f\u0131nd\u0131rma y\u00f6ntemi uydurmay\u0131n. Yap\u0131\u015fkan astarl\u0131 bir s\u0131zd\u0131rmazl\u0131k i\u015fi i\u00e7in, \u00e7\u00f6z\u00fclmemi\u015f y\u00fczey uyumlulu\u011fu veya haz\u0131rl\u0131\u011f\u0131, k\u0131l\u0131f\u0131n uygulamaya haz\u0131r olmad\u0131\u011f\u0131 anlam\u0131na gelir.<\/p>\n<h2>5. K\u0131l\u0131f\u0131 \u00e7izime g\u00f6re konumland\u0131r\u0131n<\/h2>\n<p>K\u0131l\u0131f\u0131 belirtilen konumuna ta\u015f\u0131y\u0131n ve her iki u\u00e7taki kapsama alan\u0131n\u0131 kontrol edin.<\/p>\n<p><strong>Beklenen sonu\u00e7:<\/strong> Ek yeri ve gerekli her iki bindirme pay\u0131, hedeflenen nihai kaplama alan\u0131 i\u00e7inde kalmal\u0131d\u0131r. Bir u\u00e7ta kaplama eksikse \u0131s\u0131tmadan \u00f6nce yeniden konumland\u0131r\u0131n; di\u011fer u\u00e7taki fazlal\u0131k malzeme bu gereklili\u011fi kar\u015f\u0131lamaz.<\/p>\n<figure class=\"wp-block-image\">\n  <img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/how-to-select-and-apply-heat-shrink-tubing-to-a-cable-splice-application-sequence.webp\" alt=\"Three conceptual states of a sleeve preloaded on a cable, positioned over a joined splice and recovered after cooling\"><figcaption>Eri\u015fim m\u00fcmk\u00fcnken \u00f6n y\u00fckleme yap\u0131n, ba\u011flant\u0131 onay\u0131ndan sonra konumland\u0131r\u0131n, ard\u0131ndan se\u00e7ilen i\u015fleme g\u00f6re b\u00fcz\u00fcn ve so\u011futun.<\/figcaption><\/figure>\n<h2>6. Belirtilen \u0131s\u0131tma i\u015flemiyle b\u00fcz\u00fcn.<\/h2>\n<p>HTS, kontroll\u00fc ve e\u015fit \u0131s\u0131yla homojen bir b\u00fcz\u00fclme gerektirir; di\u011fer modeller kendi ilgili i\u015flemlerini gerektirir.<\/p>\n<p>Ger\u00e7ek montaj i\u00e7in belirlenen \u0131s\u0131 kayna\u011f\u0131n\u0131, \u0131s\u0131tma s\u0131ras\u0131n\u0131, maruz kalma s\u0131n\u0131rlar\u0131n\u0131 ve tamamlanma kriterlerini kullan\u0131n. Katalogdaki b\u00fcz\u00fclme s\u0131cakl\u0131\u011f\u0131; \u0131s\u0131 tabancas\u0131 kadran ayar\u0131, noz\u00fcl mesafesi veya bekleme s\u00fcresi de\u011fildir. Bu i\u015flem gereklilikleri \u00e7\u00f6z\u00fcmlenmemi\u015fse, \u0131s\u0131tma yapmadan \u00f6nce ilgili talimatlar\u0131 temin edin.<\/p>\n<p><a href=\"https:\/\/standards.nasa.gov\/sites\/default\/files\/standards\/NASA\/A\/4\/nasa-std-87394a_w_change_4_0.pdf\" target=\"_blank\" rel=\"noopener\">NASA-STD-8739.4A De\u011fi\u015fiklik 4, \u00a79.9<\/a>, NASA g\u00f6rev donan\u0131m\u0131 kapsam\u0131 dahilinde, \u0131s\u0131y\u0131 ve maruziyeti boru boyutu\/tipi ile ili\u015fkilendirir ve kaplanan \u00f6\u011fenin ve yak\u0131ndaki \u0131s\u0131ya duyarl\u0131 par\u00e7alar\u0131n korunmas\u0131n\u0131 gerektirir. Bunlar faydal\u0131 i\u015f\u00e7ilik s\u0131n\u0131rlar\u0131d\u0131r; bir YOCL ek yeri i\u00e7in ayarlar\u0131 belirlemezler.<\/p>\n<p><strong>Montaj\u0131 tutun<\/strong> belirtilen b\u00fcz\u00fclme i\u015flemi termal s\u0131n\u0131rlar\u0131 dahilinde tamamlanam\u0131yorsa veya g\u00f6zle g\u00f6r\u00fcl\u00fcr \u0131s\u0131 hasar\u0131 olu\u015fuyorsa.<\/p>\n<h2>7. Uygulamay\u0131 so\u011futun ve inceleyin<\/h2>\n<p>HTS'yi ellemeden \u00f6nce so\u011fumas\u0131n\u0131 bekleyin; se\u00e7ilen montaj\u0131n so\u011futma ve inceleme talimatlar\u0131n\u0131 izleyin. \u015eunlar\u0131 kontrol edin:<\/p>\n<ul>\n<li>Konum ve fiili bitmi\u015f kaplaman\u0131n teknik resme uygunlu\u011fu.<\/li>\n<li>Gerekti\u011fi yerlerde d\u00fczg\u00fcn b\u00fcz\u00fclme ve kavrama.<\/li>\n<li>\u00c7atlaklar, delikler, kabarc\u0131klar veya yan\u0131k b\u00f6lgeler ile kablo k\u0131l\u0131f\u0131ndaki hasarlar.<\/li>\n<li>Modele \u00f6zel yap\u0131\u015ft\u0131r\u0131c\u0131 ve aray\u00fcz kabul kriterleri.<\/li>\n<\/ul>\n<p>NASA-STD-8739.4A \u00a7\u00a79.10\u20139.11, konumland\u0131rma, b\u00fcz\u00fclme\/kavrama ve g\u00f6zle g\u00f6r\u00fcl\u00fcr kusur kontrollerine dair kapsaml\u0131 \u00f6rnekler sunar. Yaln\u0131zca g\u00f6r\u00fcn\u00fcm, elektriksel performans\u0131 veya tam bir gizli yap\u0131\u015fkan ba\u011f\u0131n\u0131 kan\u0131tlamaz. Bir yap\u0131\u015fkan boncu\u011fu, belirtilen yerel bir i\u015flem i\u015fareti olabilir; tek ba\u015f\u0131na \u00e7evresel bir s\u0131zd\u0131rmazl\u0131k sa\u011flad\u0131\u011f\u0131n\u0131 kan\u0131tlamaz.<\/p>\n<p>Route defects or unresolved sealing to the applicable rework process. The <a href=\"https:\/\/yocl.com\/tr\/why-heat-shrink-tubing-splits-or-fails-to-seal\/\">split-or-fail-to-seal guide<\/a> explains the separate diagnosis task; do not keep reheating without authorized rework instructions.<\/p>\n<h2>8. Complete the release record before restoration<\/h2>\n<p>Record three separate decisions: <strong>connection accepted<\/strong>, <strong>sleeve workmanship accepted<\/strong>, ve <strong>required assembly tests passed<\/strong>. Enter the cable\/splice and sleeve identification, measured coverage, process reference and test results. A missing seal-verification requirement cannot be replaced with \u201clooks tight.\u201d<\/p>\n<p>Complete the specified electrical and, where required, environmental acceptance tests using the assembly procedure. Hold failed or incomplete results. Restore service only through the equipment\/site authorization process; OSHA 1910.333(b)(2)(v) sets out restoration checks for its U.S. workplace scope.<\/p>\n<p>For YOCL model selection, provide the pass-over dimension, both landing diameters, required coverage, jacket material and duty when requesting the applicable tubing and process documentation. That information turns a catalogue size candidate into a reviewable application choice.<\/p>\n<h2>Referanslar<\/h2>\n<ol>\n<li><a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.333\" target=\"_blank\" rel=\"noopener\">OSHA \u2014 29 CFR 1910.333<\/a>, electrical work practices, verification and restoration.<\/li>\n<li><a href=\"https:\/\/yocl.com\/tr\/heat-shrink-tubing-manufacturer\/\">YOCL \u2014 Heat Shrink Tubing<\/a>, current product families.<\/li>\n<li><a href=\"https:\/\/standards.nasa.gov\/sites\/default\/files\/standards\/KSC\/F\/KSC-E-165-REV-F.pdf\" target=\"_blank\" rel=\"noopener\">NASA KSC \u2014 KSC-E-165 Revision F<\/a>, \u00a73.8.1.1.1(a), dimensional selection.<\/li>\n<li><a href=\"https:\/\/yocl.com\/tr\/product\/hs3x-3-1-dual-wall-adhesive-lined-heat-shrink-tubing\/\">YOCL \u2014 HS3X 3:1 Dual-Wall Tubing<\/a>, supplied\/recovered size table.<\/li>\n<li><a href=\"https:\/\/yocl.com\/tr\/product\/hts-2-1-single-wall-heat-shrink-tubing\/\">YOCL \u2014 HTS 2:1 Single-Wall Tubing<\/a>, Installation Notes.<\/li>\n<li><a href=\"https:\/\/standards.nasa.gov\/sites\/default\/files\/standards\/NASA\/A\/4\/nasa-std-87394a_w_change_4_0.pdf\" target=\"_blank\" rel=\"noopener\">NASA \u2014 NASA-STD-8739.4A Change 4<\/a>, \u00a7\u00a79.9\u20139.11, heating and workmanship.<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>Choose heat shrink tubing that passes over the largest splice feature, recovers below the smallest landing diameter and preserves the required coverage after shrinking. Cut and preload it before closing the connection, accept the electrical joint, position the sleeve, recover it with the specified heating process, then cool, inspect and complete the required assembly tests. [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3150,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[165],"tags":[],"class_list":["post-3151","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-heat-shrink-insulation"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/3151","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/comments?post=3151"}],"version-history":[{"count":1,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/3151\/revisions"}],"predecessor-version":[{"id":3152,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/3151\/revisions\/3152"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/3150"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=3151"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/categories?post=3151"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/tags?post=3151"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}