{"id":3156,"date":"2026-10-11T05:56:19","date_gmt":"2026-10-11T05:56:19","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=9d0b93002503f4a0d38574567beafddc17efacc3eac54a6fd1708f91a77af67f"},"modified":"2026-10-11T05:56:19","modified_gmt":"2026-10-11T05:56:19","slug":"screw-vs-spring-terminal-blocks","status":"publish","type":"post","link":"https:\/\/yocl.com\/tr\/screw-vs-spring-terminal-blocks\/","title":{"rendered":"Vida vs Yayl\u0131 Klemensler: Kablolama ve Bak\u0131m \u00d6d\u00fcnle\u015fimleri"},"content":{"rendered":"<p><strong>Belgelenmi\u015f bir s\u0131kma i\u015flemi montaj ve servis uygulaman\u0131za uydu\u011funda vida klemensleri se\u00e7in. Tel haz\u0131rl\u0131\u011f\u0131n\u0131 ve \u00e7al\u0131\u015fmas\u0131n\u0131 onaylad\u0131ktan sonra, iletken-kelep\u00e7e tork ayar\u0131 ad\u0131m\u0131n\u0131 kald\u0131rmak i\u015f ak\u0131\u015f\u0131n\u0131za uydu\u011funda yayl\u0131 klemensleri se\u00e7in.<\/strong> Do\u011frudan itme, bir yay tasar\u0131m\u0131d\u0131r. Ba\u011flant\u0131 etiketlerinden hi\u00e7biri bir denetim aral\u0131\u011f\u0131 belirlemez.<\/p>\n<p>Bu kar\u015f\u0131la\u015ft\u0131rma, bak\u0131r iletkenler i\u00e7in mod\u00fcler DIN ray klemenslerini ilgilendirmektedir. Ayn\u0131 devre fonksiyonuna, uygun elektriksel de\u011ferlere ve servis ko\u015fullar\u0131na sahip adaylar\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131n. Klemens fonksiyonlar\u0131 ve montaj bi\u00e7imlerinin daha geni\u015f haritas\u0131 i\u00e7in, <a href=\"https:\/\/yocl.com\/tr\/what-is-a-terminal-block\/\">terminal blo\u011fu k\u0131lavuzu<\/a>.<\/p>\n<h2>Kablolama \u00f6d\u00fcnle\u015fimleri: i\u015fin nereye gitti\u011fi<\/h2>\n<p>Faydal\u0131 kar\u015f\u0131la\u015ft\u0131rma, tel haz\u0131rl\u0131\u011f\u0131 ve eri\u015fim dahil olmak \u00fczere eksiksiz sonland\u0131rma ve yeniden i\u015fleme i\u015flemidir.<\/p>\n<table>\n<thead>\n<tr>\n<th>Kar\u015f\u0131la\u015ft\u0131rma noktas\u0131<\/th>\n<th>Vidal\u0131 terminal<\/th>\n<th>Yayl\u0131 terminal<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0130letken-kelep\u00e7e i\u015flemi<\/td>\n<td>Ba\u011flant\u0131 bir vida ile sa\u011flan\u0131r; belirlenen s\u0131kma de\u011ferini ve alet gereksinimlerini al\u0131n<\/td>\n<td>Giri\u015f, tasar\u0131ma ba\u011fl\u0131 olarak kelep\u00e7e a\u00e7\u0131kl\u0131\u011f\u0131 gerektirir veya do\u011frudan itme imkan\u0131 tan\u0131r<\/td>\n<\/tr>\n<tr>\n<td>Tel uygunlu\u011fu<\/td>\n<td>\u0130letken tipini, boyutunu ve izin verilen haz\u0131rl\u0131\u011f\u0131n\u0131 onaylay\u0131n<\/td>\n<td>Ayn\u0131 alanlar\u0131 onaylay\u0131n; yay etiketi bunlar\u0131 belirlemez<\/td>\n<\/tr>\n<tr>\n<td>Yeniden i\u015fleme s\u0131ras\u0131nda eri\u015fim<\/td>\n<td>S\u0131kma vidas\u0131na ve iletken giri\u015fine eri\u015fime izin verin<\/td>\n<td>A\u00e7ma\/serbest b\u0131rakma \u00f6zelli\u011fine ve iletken giri\u015fine eri\u015fime izin verin<\/td>\n<\/tr>\n<tr>\n<td>Kar\u015f\u0131la\u015ft\u0131rma i\u015f ak\u0131\u015f\u0131<\/td>\n<td>Haz\u0131rl\u0131k, yerle\u015ftirme, s\u0131kma, belgelenmi\u015f kontroller ve \u00e7\u0131karma<\/td>\n<td>Haz\u0131rl\u0131k, a\u00e7ma\/yerle\u015ftirme, belgelenmi\u015f kontroller ve serbest b\u0131rakma<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Vidal\u0131 ba\u011flant\u0131lar, ara bir kelep\u00e7eleme par\u00e7as\u0131 arac\u0131l\u0131\u011f\u0131yla bas\u0131n\u00e7 iletebilir. Her vida ucunun do\u011frudan tele temas etti\u011fini varsaymay\u0131n. Uluslararas\u0131 Elektroteknik Komisyonu (IEC), terminolojisinde do\u011frudan ve dolayl\u0131 vida etkisini ay\u0131rt eder. <a href=\"https:\/\/cdn.standards.iteh.ai\/samples\/6612\/c62436012e3c4550803154918de1f095\/IEC-60999-1-1999.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60999-1 genel \u00f6nizleme, B\u00f6l\u00fcm 3<\/a>.<\/p>\n<p>Adil bir montaj kar\u015f\u0131la\u015ft\u0131rmas\u0131 i\u00e7in ayn\u0131 iletkeni kullan\u0131n ve her uygun model i\u00e7in ger\u00e7ek at\u00f6lye haz\u0131rl\u0131k ve kabul s\u00fcrecini tekrarlay\u0131n. H\u0131zl\u0131 bir yerle\u015ftirme g\u00f6sterisi, y\u00fcks\u00fck haz\u0131rl\u0131\u011f\u0131n\u0131, s\u0131kma kontrol\u00fcn\u00fc veya daha sonra iletkenin \u00e7\u0131kar\u0131lmas\u0131n\u0131 \u00f6l\u00e7mez. E\u015fle\u015fen \u00f6l\u00e7\u00fcmler olmadan, kablolama h\u0131z\u0131 hakk\u0131ndaki y\u00fczdesel iddia, karara \u00e7ok az \u015fey katar.<\/p>\n<h2>Yayl\u0131 kelep\u00e7e ve itmeli tip farkl\u0131 \u015feyleri tan\u0131mlar<\/h2>\n<p><strong>Yayl\u0131 kelep\u00e7e, kelep\u00e7eleme mekanizmas\u0131n\u0131 tan\u0131mlar; itmeli tip, bir giri\u015f eylemini tan\u0131mlar.<\/strong> Yayl\u0131 tasar\u0131mlar bir aletle a\u00e7\u0131labilir, bir akt\u00fcat\u00f6r arac\u0131l\u0131\u011f\u0131yla \u00e7al\u0131\u015ft\u0131r\u0131labilir veya do\u011frudan tak\u0131larak kullan\u0131labilir. IEC 60352-7 bu farkl\u0131 d\u00fczenekleri g\u00f6stermektedir. <a href=\"https:\/\/cdn.standards.iteh.ai\/samples\/iec\/iec-60352-7-2026\/d09cc29d544d4f5e93578bf86c8839d0\/iec-60352-7-2026.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60352-7:2026 genel \u00f6nizleme, \u015eekil 1<\/a>.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/screw-vs-spring-terminal-blocks-connection-modes.webp\" alt=\"Conceptual screw, cage-spring and push-in terminal blocks\"><figcaption>Kavramsal d\u0131\u015f formlar; model talimatlar\u0131n\u0131 kontrol edin.<\/figcaption><\/figure>\n<p>Do\u011frudan takma, aletsiz s\u00f6kme sa\u011flamaz. \u00c7evredeki kablolama ve tak\u0131l\u0131 aksesuarlarla birlikte s\u00f6kme eri\u015fimini do\u011frulay\u0131n.<\/p>\n<h2>\u0130letken haz\u0131rl\u0131\u011f\u0131 se\u00e7imi de\u011fi\u015ftirebilir<\/h2>\n<p>\u0130letken kabul\u00fc, kelep\u00e7e tipinden ayr\u0131 bir \u00f6zelliktir. IEC 60947-7-1 terminal bloklar\u0131n\u0131 kabul edilen iletken formlar\u0131na ve haz\u0131rl\u0131k kapasitesine g\u00f6re s\u0131n\u0131fland\u0131r\u0131r ve anma kesitini bir ba\u011flant\u0131 kapasitesi aral\u0131\u011f\u0131ndan ay\u0131r\u0131r. <a href=\"https:\/\/webstore.ansi.org\/preview-pages\/IEC\/preview_iec60947-7-1%7Bed4.0%7Db.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60947-7-1:2025 genel \u00f6nizleme, B\u00f6l\u00fcmler 3\u20134<\/a>.<\/p>\n<p>Kat\u0131 u\u00e7, \u00e7\u0131plak telli u\u00e7 ve y\u00fcks\u00fckl\u00fc u\u00e7 farkl\u0131 sonland\u0131rma ko\u015fullar\u0131 sunar. \u0130letken tipiniz, boyutunuz, haz\u0131rl\u0131\u011f\u0131n\u0131z ve iletken say\u0131n\u0131z i\u00e7in ilgili blo\u011fun bilgilerini kontrol edin. Bir y\u00fcks\u00fck, her terminali o kablo i\u00e7in otomatik olarak uygun hale getirmez. The <a href=\"https:\/\/yocl.com\/tr\/what-is-a-wire-ferrule\/\">tel-y\u00fcks\u00fck k\u0131lavuzu<\/a> haz\u0131rlanm\u0131\u015f u\u00e7 uyumlulu\u011fu sorusunu daha ayr\u0131nt\u0131l\u0131 a\u00e7\u0131klar.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/screw-vs-spring-terminal-blocks-conductor-preparation.webp\" alt=\"Disconnected solid, ferruled stranded and bare stranded conductor ends for model-specific compatibility checking\"><figcaption>Haz\u0131rlanm\u0131\u015f ucu model talimatlar\u0131yla kar\u015f\u0131la\u015ft\u0131r\u0131n. \u0130ll\u00fcstrasyon, belirli bir terminal i\u00e7in herhangi bir \u00f6rnek onaylamaz.<\/figcaption><\/figure>\n<p>YOCL \u0130ngiliz vidas\u0131, SJ kafes-yayl\u0131 ve PT itmeli tipleri listeler. Genel model bilgileri, benzer bir boyut atamas\u0131n\u0131n neden ikame i\u00e7in yetersiz oldu\u011funu g\u00f6stermektedir.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u00d6rnek ve kaynak<\/th>\n<th>Halka a\u00e7\u0131k beyan edilmi\u015f alan<\/th>\n<th>Onaylanmas\u0131 i\u00e7in ne b\u0131rak\u0131yor<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><a href=\"https:\/\/yocl.com\/tr\/product\/uk-series-screw-din-rail-terminal-blocks\/\">\u0130ngiliz vidas\u0131 tipindeki UK-2.5B<\/a><\/td>\n<td>Sat\u0131r, bir M3 vidas\u0131n\u0131 tan\u0131mlar ancak bir iletken aral\u0131\u011f\u0131 vermez<\/td>\n<td>Kabul edilen iletken\/haz\u0131rl\u0131k aral\u0131\u011f\u0131 ve s\u0131kma torku; M3 bir vida boyutudur, tork de\u011fildir<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/yocl.com\/tr\/product\/sj-terminal-blocks\/\">Kafes yay aral\u0131\u011f\u0131nda SJ-2.5<\/a><\/td>\n<td>Kat\u0131 iletkenler: 0.2\u20134 mm\u00b2; esnek iletkenler: 0.2\u20132.5 mm\u00b2<\/td>\n<td>Haz\u0131rl\u0131\u011fa \u00f6zg\u00fc kabul ve a\u00e7ma\/b\u0131rakma talimatlar\u0131<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/yocl.com\/tr\/product\/pt-series-push-in-din-rail-terminal-blocks\/\">PT itmeli aral\u0131kta PT2.5<\/a><\/td>\n<td>Nominal kesit: 2.5 mm\u00b2; seri, uygun kat\u0131 veya y\u00fcks\u00fckl\u00fc iletkenlerin do\u011frudan tak\u0131lmas\u0131n\u0131 tan\u0131mlar<\/td>\n<td>Se\u00e7ilen haz\u0131rlanm\u0131\u015f u\u00e7 ve b\u0131rakma y\u00f6ntemi i\u00e7in tam kabul edilen aral\u0131klar<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Bunlar birinci taraf katalog alanlar\u0131d\u0131r, e\u015fle\u015fen bir performans testi de\u011fildir. SJ-2.5 i\u00e7in verilen esnek iletken aral\u0131\u011f\u0131 PT2.5'e aktar\u0131lamaz. Mevcut bir terminalin yerine ge\u00e7ecek \u015fekilde i\u015flem yapmadan \u00f6nce eksik model bilgilerini talep edin.<\/p>\n<h2>Bak\u0131m: s\u0131kmay\u0131 muayeneden ay\u0131r\u0131n<\/h2>\n<p>Vida terminali i\u00e7in kurulum i\u015flemi, belirtilen s\u0131kma talimatlar\u0131n\u0131 gerektirir. Bak\u0131m politikas\u0131, yeniden s\u0131kman\u0131n gerekip gerekmedi\u011fini ve ne zaman gerekti\u011fini ayr\u0131 ayr\u0131 belirtmelidir. Ba\u011flant\u0131 ad\u0131ndan y\u0131ll\u0131k bir aral\u0131k icat etmeyin; tam terminal ve ekipman i\u00e7in bu politikay\u0131 al\u0131n.<\/p>\n<p>Yayl\u0131 iletken kelep\u00e7esi, o temastaki kullan\u0131c\u0131 taraf\u0131ndan ayarlanan s\u0131kma i\u015flemini ortadan kald\u0131r\u0131r. Hasarl\u0131 par\u00e7alar\u0131, bozulan kablolar\u0131 veya uygun olmayan bir ba\u011flant\u0131y\u0131 ara\u015ft\u0131rma ihtiyac\u0131n\u0131 ortadan kald\u0131rmaz. Bir tedarik\u00e7i bir terminali \u201cbak\u0131m gerektirmeyen\u201d olarak adland\u0131r\u0131yorsa, bu ifadenin hangi g\u00f6revi hari\u00e7 tuttu\u011funu ve ekipman bak\u0131m plan\u0131nda hangi denetimlerin kald\u0131\u011f\u0131n\u0131 sorun.<\/p>\n<p>Daha geni\u015f bak\u0131m rehberli\u011fine bir \u00f6rnek olarak, B\u00fcy\u00fck Britanya Sa\u011fl\u0131k ve G\u00fcvenlik \u0130daresi, tehlikeyi \u00f6nlemek i\u00e7in bak\u0131m ve sabit tesislerin yetkin denetimini\/test edilmesini talep eder. Genel ekipman rehberli\u011fi, hasarl\u0131 konekt\u00f6rleri, g\u00fcvensiz kablolar\u0131 ve yan\u0131k izlerini harekete ge\u00e7me nedenleri olarak tan\u0131mlar. DIN terminal yeniden s\u0131kma aral\u0131\u011f\u0131 sa\u011flamaz. <a href=\"https:\/\/www.hse.gov.uk\/electricity\/introduction.htm\" target=\"_blank\" rel=\"noopener\">HSE, Elektrik g\u00fcvenli\u011fine giri\u015f<\/a>.<\/p>\n<p>Her iki mekanizma i\u00e7in de, herhangi bir ba\u011flant\u0131 i\u015fini ekipman\u0131n izolasyon ve servis talimatlar\u0131na g\u00f6re d\u00fczenleyin. Hasarl\u0131 oldu\u011fu d\u00fc\u015f\u00fcn\u00fclen bir temas, yetkin bir de\u011ferlendirme gerektirir; kelep\u00e7eleme teknolojisini de\u011fi\u015ftirmek, altta yatan sorunun \u00e7\u00f6z\u00fcld\u00fc\u011f\u00fcn\u00fc belirlemez.<\/p>\n<h2>Hangi \u00f6d\u00fcnle\u015fim panonuza uyuyor?<\/h2>\n<table>\n<thead>\n<tr>\n<th>Durumunuz<\/th>\n<th>Aday karar\u0131<\/th>\n<th>Karar\u0131 savunulabilir k\u0131lan ko\u015ful<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Yerle\u015fik vida tasar\u0131m\u0131, kontroll\u00fc s\u0131kma aletleri ve eri\u015filebilir terminaller<\/td>\n<td>Vida terminallerini koruyun veya se\u00e7in<\/td>\n<td>Kesin iletken ve servis talimatlar\u0131 uyuyor; mevcut i\u015flemin net bir kabul y\u00f6ntemi var<\/td>\n<\/tr>\n<tr>\n<td>Onaylanm\u0131\u015f haz\u0131rlanm\u0131\u015f bir u\u00e7 kullanarak tekrarlanan montaj<\/td>\n<td>Uygun bir do\u011frudan itmeli yayl\u0131 terminali d\u00fc\u015f\u00fcn\u00fcn<\/td>\n<td>Yaln\u0131zca takmay\u0131 de\u011fil, t\u00fcm haz\u0131rl\u0131k\/takma\/\u00e7\u0131karma s\u00fcrecini de\u011ferlendirin<\/td>\n<\/tr>\n<tr>\n<td>Sahada kablolama farkl\u0131 iletken formlar\u0131 getirir<\/td>\n<td>Uyumlu bir vida veya a\u00e7\u0131k yayl\u0131 bir tasar\u0131m uyabilir<\/td>\n<td>Beklenen her tel formunu do\u011frulay\u0131n; yay etiketinden do\u011frudan takma uygunlu\u011funu \u00e7\u0131karmay\u0131n<\/td>\n<\/tr>\n<tr>\n<td>Farkl\u0131 devrelerin farkl\u0131 servis ihtiya\u00e7lar\u0131 vard\u0131r<\/td>\n<td>Her iki mekanizma da panoda bulunabilir<\/td>\n<td>Her ba\u011flant\u0131y\u0131 nitelendirin ve talimatlar\u0131n\u0131 tan\u0131mlanabilir tutun<\/td>\n<\/tr>\n<tr>\n<td>Se\u00e7im yaln\u0131zca titre\u015fim, \u0131s\u0131nma veya g\u00fcvenilirlik ile gerek\u00e7elendiriliyor<\/td>\n<td>Etiketlerden hi\u00e7biri karar vermez<\/td>\n<td>Tam olarak adaylar i\u00e7in uygulamaya \u00f6zel beyanlar veya e\u015fle\u015fen kan\u0131tlar al\u0131n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Seri de\u011fi\u015fikli\u011fi i\u00e7in ayr\u0131ca ayak izini, ray uyumunu, u\u00e7 plakalar\u0131n\u0131, k\u00f6pr\u00fcleri ve i\u015faretleyicileri do\u011frulay\u0131n. Payla\u015f\u0131lan DIN montaj\u0131 aksesuar de\u011fi\u015ftirilebilirli\u011fini sa\u011flamaz. Vidalama veya serbest b\u0131rakma eri\u015fimini ama\u00e7lanan servis g\u00f6revi s\u0131ras\u0131nda kullan\u0131labilir durumda tutun.<\/p>\n<p>Kullan\u0131n <a href=\"https:\/\/yocl.com\/tr\/terminal-blocks-manufacturer\/\">YOCL terminal blo\u011fu serisi<\/a> adaylar\u0131 belirlemek i\u00e7in. \u0130letken t\u00fcrlerini ve haz\u0131rlanm\u0131\u015f u\u00e7lar\u0131n\u0131, devre i\u015flevini, gerekli derecelendirmeleri ve eri\u015fim k\u0131s\u0131tlamalar\u0131n\u0131 sa\u011flay\u0131n, ard\u0131ndan e\u015fle\u015fen ba\u011flant\u0131 ve bak\u0131m belgelerini isteyin. Bu, bir mekanizma tercihini incelenebilir bir terminal se\u00e7imine d\u00f6n\u00fc\u015ft\u00fcr\u00fcr.<\/p>\n<h2>Referanslar<\/h2>\n<ul>\n<li>IEC, <a href=\"https:\/\/cdn.standards.iteh.ai\/samples\/6612\/c62436012e3c4550803154918de1f095\/IEC-60999-1-1999.pdf\" target=\"_blank\" rel=\"noopener\"><em>IEC 60999-1:1999 \u2014 genel \u00f6nizleme<\/em><\/a>, B\u00f6l\u00fcm 3, vida ve vidal\u0131 olmayan s\u0131k\u0131\u015ft\u0131rma terminolojisi.<\/li>\n<li>IEC, <a href=\"https:\/\/cdn.standards.iteh.ai\/samples\/iec\/iec-60352-7-2026\/d09cc29d544d4f5e93578bf86c8839d0\/iec-60352-7-2026.pdf\" target=\"_blank\" rel=\"noopener\"><em>IEC 60352-7:2026 \u2014 genel \u00f6nizleme<\/em><\/a>, B\u00f6l\u00fcm 3 ve \u015eekil 1, yayl\u0131 s\u0131k\u0131\u015ft\u0131rma terminolojisi ve \u00e7al\u0131\u015fmas\u0131.<\/li>\n<li>IEC, <a href=\"https:\/\/webstore.ansi.org\/preview-pages\/IEC\/preview_iec60947-7-1%7Bed4.0%7Db.pdf\" target=\"_blank\" rel=\"noopener\"><em>IEC 60947-7-1:2025 \u2014 public preview<\/em><\/a>, Sections 3\u20134, terminal-block definitions and classification. Only cited public preview sections were consulted; these references do not establish YOCL certification.<\/li>\n<li>YOCL ELECTRIC, <a href=\"https:\/\/yocl.com\/tr\/product\/uk-series-screw-din-rail-terminal-blocks\/\"><em>UK Serisi Vidal\u0131 DIN Ray Klemensleri<\/em><\/a>, UK-2.5B catalogue row.<\/li>\n<li>YOCL ELECTRIC, <a href=\"https:\/\/yocl.com\/tr\/product\/sj-terminal-blocks\/\"><em>SJ Kafes Yayl\u0131 DIN Ray Klemensler<\/em><\/a>, SJ-2.5 catalogue row.<\/li>\n<li>YOCL ELECTRIC, <a href=\"https:\/\/yocl.com\/tr\/product\/pt-series-push-in-din-rail-terminal-blocks\/\"><em>PT Serisi Yayl\u0131 S\u0131kmal\u0131 DIN Ray Klemensler<\/em><\/a>, PT2.5 row and series operation description. First-party pages checked 11 October 2026.<\/li>\n<li>Health and Safety Executive, Great Britain, <a href=\"https:\/\/www.hse.gov.uk\/electricity\/introduction.htm\" target=\"_blank\" rel=\"noopener\"><em>Introduction to electrical safety<\/em><\/a>, Maintenance and Fixed installations.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Choose screw terminal blocks when a documented tightening process fits your assembly and service practice. Choose spring terminal blocks when removing the conductor-clamp torque-setting step suits your workflow, after confirming wire preparation and operation. Direct push-in is one spring design. Neither connection label establishes an inspection interval. This comparison concerns modular DIN rail terminals for [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3155,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[164],"tags":[],"class_list":["post-3156","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-terminals-connections"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/3156","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/comments?post=3156"}],"version-history":[{"count":1,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/3156\/revisions"}],"predecessor-version":[{"id":3157,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/3156\/revisions\/3157"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/3155"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=3156"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/categories?post=3156"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/tags?post=3156"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}