{"id":3244,"date":"2026-10-27T00:38:30","date_gmt":"2026-10-27T00:38:30","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=0b6314652b456cee29db24e0ac47973d3bf4dcbe6342aa7100c1c22c8d80ea50"},"modified":"2026-10-27T00:38:30","modified_gmt":"2026-10-27T00:38:30","slug":"heat-shrink-end-caps-explained-cable-end-sealing-and-storage","status":"publish","type":"post","link":"https:\/\/yocl.com\/tr\/heat-shrink-end-caps-explained-cable-end-sealing-and-storage\/","title":{"rendered":"Is\u0131yla Daralan U\u00e7 Kapaklar\u0131 A\u00e7\u0131klamas\u0131: Kablo Ucu Yal\u0131t\u0131m\u0131 ve Depolama"},"content":{"rendered":"<p>A <strong>\u0131s\u0131yla daralan u\u00e7 kapa\u011f\u0131<\/strong> a\u00e7\u0131kta kalan bir kablo ucunu korumak i\u00e7in kullan\u0131lan kapal\u0131 u\u00e7lu bir \u00f6rt\u00fcd\u00fcr. Giri\u015f a\u00e7\u0131kl\u0131\u011f\u0131 kablonun etraf\u0131nda daral\u0131r, yap\u0131\u015fkan astarl\u0131 tasar\u0131m\u0131 ise belirtilen uygulama s\u00fcreci alt\u0131nda uygun bir kablo y\u00fczeyi ile aray\u00fcz olu\u015fturur. Amac\u0131, depolama, ta\u015f\u0131ma veya belgelenmi\u015f bir u\u00e7 yal\u0131t\u0131m uygulamas\u0131 s\u0131ras\u0131nda kablo ucu korumas\u0131 sa\u011flamakt\u0131r.<\/p>\n<p>Bir u\u00e7 kapa\u011f\u0131 iletkenleri birle\u015ftirmez, bir kabloyu elle tutulabilir hale getirmez veya otomatik olarak enerjili bir devre i\u00e7in sonland\u0131rma niteli\u011fi ta\u015f\u0131maz. A\u015fa\u011f\u0131daki b\u00f6l\u00fcmde a\u00e7\u0131klanan a\u00e7\u0131k u\u00e7lu makaronlardan farkl\u0131 bir s\u0131n\u0131r\u0131 kapat\u0131r: <a href=\"https:\/\/yocl.com\/tr\/what-is-heat-shrink-tubing\/\">\u0131s\u0131yla daralan makaronlara genel bak\u0131\u015f<\/a>.<\/p>\n<h2>U\u00e7 Kapa\u011f\u0131 Neyi Kapat\u0131r?<\/h2>\n<p>A\u00e7\u0131k makaronlar\u0131n her iki ucunda da bir ge\u00e7i\u015f yolu bulunur. Bir kablo u\u00e7 kapa\u011f\u0131n\u0131n bir montaj a\u00e7\u0131kl\u0131\u011f\u0131 ve \u00f6nceden yal\u0131t\u0131lm\u0131\u015f bir ucu vard\u0131r. G\u00f6vdesi kablo ucunu kaplar; giri\u015f taraf\u0131, uygulama talimatlar\u0131nda belirtilen kablo k\u0131l\u0131f\u0131 veya di\u011fer y\u00fczey ile aray\u00fcz\u00fc sa\u011flar.<\/p>\n<p>YOCL\u2019in mevcut <a href=\"https:\/\/yocl.com\/tr\/product\/hsc-f-4-1-dual-wall-heat-shrink-waterproof-end-cap\/\">HSC-F<\/a> ve <a href=\"https:\/\/yocl.com\/tr\/product\/hsc-b-4-1-semi-rigid-dual-wall-heat-shrink-waterproof-end-cap\/\">HSC-B<\/a> \u00e7izimleri iki malzeme i\u015flevini tan\u0131mlar:<\/p>\n<ul>\n<li><strong>D\u0131\u015f duvar:<\/strong> kablo ucu b\u00f6lgesini \u00e7evreleyen ve koruyan geri kazan\u0131labilir kaplama.<\/li>\n<li><strong>S\u0131cakta eriyen yap\u0131\u015fkan astar:<\/strong> uygulama ve so\u011fuma s\u0131ras\u0131nda belirtilen kablo y\u00fczeyi ile ba\u011f olu\u015fturmas\u0131 ama\u00e7lanan aray\u00fcz malzemesi.<\/li>\n<\/ul>\n<p>Kapal\u0131 u\u00e7 ve kablo giri\u015f aray\u00fcz\u00fc birlikte de\u011ferlendirilmelidir. Bozulmam\u0131\u015f bir uca sahip ba\u015fl\u0131k, yine de uygun olmayan bir giri\u015f aray\u00fcz\u00fcne sahip olabilir. K\u0131l\u0131f etraf\u0131ndaki s\u0131k\u0131 bir uyum, tek ba\u015f\u0131na tam s\u0131zd\u0131rmazl\u0131\u011f\u0131 do\u011frulamaz.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/heat-shrink-end-caps-explained-cable-end-sealing-and-storage-sealing-boundary.webp\" alt=\"YOCL end-cap section showing the cable-entry opening, outer wall, adhesive lining and pre-sealed tip\"><figcaption>YOCL HSC-B \u00fcr\u00fcn \u00e7izimine dayal\u0131 \u015fema. Ba\u015fl\u0131k b\u00f6l\u00fcm\u00fc, malzeme katmanlar\u0131n\u0131 ve u\u00e7 geometrisini tan\u0131mlar; onaylanm\u0131\u015f bir kurulu kablo d\u00fczene\u011fini veya boyutsal \u00f6l\u00e7e\u011fi g\u00f6stermez.<\/figcaption><\/figure>\n<p>Yap\u0131\u015ft\u0131r\u0131c\u0131y\u0131 alan y\u00fczey \u00f6nemlidir. P\u00fcr\u00fczs\u00fcz bir d\u0131\u015f k\u0131l\u0131f, d\u00fczensiz bir tekil tel grubu ve katmanl\u0131 bir g\u00fc\u00e7 kablosu yap\u0131s\u0131 farkl\u0131 s\u0131zd\u0131rmazl\u0131k sorunlar\u0131d\u0131r. Bir kablo demeti uygulamas\u0131n\u0131 g\u00f6steren \u00fcr\u00fcn foto\u011fraf\u0131, her tel demetinin veya kablo yap\u0131s\u0131n\u0131n uygun bir s\u0131zd\u0131rmazl\u0131k olu\u015fturaca\u011f\u0131n\u0131 kan\u0131tlayamaz.<\/p>\n<h2>Depolama S\u0131ras\u0131nda Kablo Ucu Yal\u0131t\u0131m\u0131 Neden \u00d6nemlidir<\/h2>\n<p>A\u00e7\u0131kta kalan bir kesik u\u00e7, kablo k\u0131l\u0131f\u0131ndaki hasardan farkl\u0131 bir nem giri\u015f yolu olu\u015fturur. Kablonun d\u0131\u015f y\u00fczeyini korumak, depolama veya ta\u015f\u0131ma s\u0131ras\u0131nda a\u00e7\u0131k b\u0131rak\u0131lan bir ucu korumaz.<\/p>\n<p>Faydal\u0131 bir end\u00fcstri \u00f6rne\u011fi, Horizon Power'\u0131n <a href=\"https:\/\/www.horizonpower.com.au\/globalassets\/media\/documents\/manuals-standards\/specifications\/hpc-8dj-03-0003-2012---spec---lv-power-cables.pdf\" target=\"_blank\" rel=\"noopener\">AG G\u00fc\u00e7 Kablolar\u0131 \u015fartnamesidir<\/a>, revizyon 4, tarih 13 Temmuz 2026. B\u00f6l\u00fcm 3.8, bu \u015fartname kapsam\u0131nda tedarik edilen kablolar\u0131n su veya korozyondan ar\u0131nd\u0131r\u0131lm\u0131\u015f olmas\u0131n\u0131 ve u\u00e7lar\u0131n\u0131n yal\u0131t\u0131lm\u0131\u015f olmas\u0131n\u0131, yal\u0131t\u0131m y\u00f6nteminin ise belgelendirilmesini gerektirir. Ayr\u0131ca, su transferine kar\u015f\u0131 kablo katmanlar\u0131n\u0131n ayr\u0131lmas\u0131n\u0131 da ele al\u0131r.<\/p>\n<p>Bu, bir Avustralyal\u0131 kamu hizmeti kurulu\u015funun tedarik gereksinimidir. Bu durum, <strong>kablo yap\u0131s\u0131 ve yal\u0131t\u0131m y\u00f6nteminin<\/strong> neden bir depolama \u015fartnamesinde yer almas\u0131 gerekti\u011fini g\u00f6sterir; belirli bir YOCL ba\u015fl\u0131\u011f\u0131n\u0131 onaylamaz veya yaln\u0131zca harici bir ba\u015fl\u0131\u011f\u0131n her katmanl\u0131 kablo gereksinimini kar\u015f\u0131lad\u0131\u011f\u0131n\u0131 kan\u0131tlamaz.<\/p>\n<p>Bir kablo ucunu kapatmak ve durumunu kabul etmek ayr\u0131 kararlard\u0131r. Bir u\u00e7 halihaz\u0131rda \u0131slak, kirlenmi\u015f veya hasarl\u0131ysa, bir ba\u015fl\u0131k uygulamak alt\u0131ndaki kablonun kabul edilebilir oldu\u011funu kan\u0131tlamaz. Bununla ilgili karar, kablo tedarik\u00e7isinin veya projenin de\u011ferlendirme s\u00fcrecine aittir.<\/p>\n<h2>\u0130ki YOCL \u00dcr\u00fcn Yolu: HSC-F ve HSC-B<\/h2>\n<p>Mevcut YOCL serisi, bu u\u00e7 ba\u015fl\u0131klar\u0131n\u0131 a\u00e7\u0131k u\u00e7lu makaronlardan ayr\u0131 olarak listeler. Her ikisi de yap\u0131\u015fkan astarl\u0131, kapal\u0131 u\u00e7lu yap\u0131 kullan\u0131r, ancak kendilerine ait model tablolar\u0131 ve beyan edilen \u00f6zellikleri vard\u0131r.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u00dcr\u00fcn yolu<\/th>\n<th>Beyan edilen yap\u0131<\/th>\n<th>Listelenen renkler<\/th>\n<th>Beyan edilen \u00e7al\u0131\u015fma aral\u0131\u011f\u0131<\/th>\n<th>\u0130ncelenecek bir sonraki belge<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>HSC-F<\/td>\n<td>S\u0131cak eriyik astarl\u0131 radyasyonla modifiye edilmi\u015f poliolefin d\u0131\u015f katman; listelenen 4:1 b\u00fcz\u00fclme<\/td>\n<td>Siyah veya \u015eeffaf<\/td>\n<td>\u221245\u00b0C ile +125\u00b0C aras\u0131<\/td>\n<td>HSC-F model boyutlar\u0131, uzunluk se\u00e7enekleri ve uygulama gereksinimleri<\/td>\n<\/tr>\n<tr>\n<td>HSC-B<\/td>\n<td>S\u0131cak eriyik astarl\u0131 yar\u0131 sert radyasyonla \u00e7apraz ba\u011fl\u0131 poliolefin d\u0131\u015f duvar; nominal 4:1 b\u00fcz\u00fclme<\/td>\n<td>Siyah<\/td>\n<td>\u221245\u00b0C ila +110\u00b0C<\/td>\n<td>HSC-B model boyutlar\u0131, A\/B uzunluk g\u00f6sterimi ve uygulama gereksinimleri<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Bunlar <strong>YOCL katalog beyanlar\u0131<\/strong>, kar\u015f\u0131la\u015ft\u0131rmal\u0131 bir saha testi veya belirli bir kablo ucu s\u0131zd\u0131rmazl\u0131k eleman\u0131n\u0131n onay\u0131 de\u011fildir. HSC-F \u00fc\u00e7 model, HSC-B ise be\u015f model listeler. Ortak bir b\u00fcz\u00fclme oran\u0131, bunlar\u0131n boyutlar\u0131n\u0131, uzunluklar\u0131n\u0131, duvar \u00f6zelliklerini veya uygulama gereksinimlerini birbirinin yerine kullan\u0131labilir k\u0131lmaz.<\/p>\n<p>Kullan\u0131n <a href=\"https:\/\/yocl.com\/tr\/product\/hsc-f-4-1-dual-wall-heat-shrink-waterproof-end-cap\/\">HSC-F \u00fcr\u00fcn bilgisi<\/a> bu \u00fcr\u00fcn ailesini incelerken ve <a href=\"https:\/\/yocl.com\/tr\/product\/hsc-b-4-1-semi-rigid-dual-wall-heat-shrink-waterproof-end-cap\/\">HSC-B \u00fcr\u00fcn bilgisi<\/a> yar\u0131 sert \u00fcr\u00fcn ailesi i\u00e7in. \u00c7al\u0131\u015fma aral\u0131klar\u0131 servis ko\u015fullar\u0131n\u0131 tan\u0131mlar. Bunlar \u0131s\u0131tma cihaz\u0131 ayarlar\u0131, a\u00e7\u0131lmam\u0131\u015f \u00fcr\u00fcn raf \u00f6mr\u00fc veya depolama s\u00fcresi garantisi de\u011fildir.<\/p>\n<p>Renk ve sertlik teknik \u00f6zellik tercihleridir, s\u0131zd\u0131rmazl\u0131k kan\u0131t\u0131n\u0131n yerini tutmazlar. \u015eeffaf bir se\u00e7enek g\u00f6r\u00fcn\u00fcrl\u00fc\u011fe yard\u0131mc\u0131 olabilir, ancak g\u00f6rsel eri\u015fim tam bir yap\u0131\u015fkan aray\u00fcz\u00fcn\u00fc kan\u0131tlamaz. Yar\u0131 sert bir d\u0131\u015f duvar da \u00e7ekme y\u00fck\u00fc veya darbe dayan\u0131m\u0131 de\u011feri olu\u015fturmaz.<\/p>\n<h2>Depolama ve Ta\u015f\u0131man\u0131n Karar\u0131 De\u011fi\u015ftirdi\u011fi Durumlar<\/h2>\n<p>Kablo ucu korumas\u0131, kablo tedarikten kullan\u0131ma ge\u00e7erken tan\u0131mlanabilir kalmal\u0131d\u0131r. \u00d6nemli olaylar; u\u00e7taki de\u011fi\u015fiklikler, maruz kald\u0131\u011f\u0131 durumlar veya kabul durumudur.<\/p>\n<table>\n<thead>\n<tr>\n<th>Olay veya ko\u015ful<\/th>\n<th>U\u00e7 kapak sorusu<\/th>\n<th>Saklanacak veya talep edilecek bilgiler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Depoya giri\u015f<\/td>\n<td>\u0130lgili kablo u\u00e7lar\u0131 korunuyor mu ve durumlar\u0131 kabul edilebilir mi?<\/td>\n<td>Kablo kimli\u011fi, tedarik\u00e7i s\u0131zd\u0131rmazl\u0131k d\u00fczenlemesi ve g\u00f6zlemlenen herhangi bir hasar veya nem endi\u015fesi<\/td>\n<\/tr>\n<tr>\n<td>Ta\u015f\u0131ma veya elle\u00e7leme<\/td>\n<td>U\u00e7 korumas\u0131 delinmi\u015f, yerinden oynam\u0131\u015f veya ba\u015fka bir \u015fekilde bozulmu\u015f mu?<\/td>\n<td>Etkilenen konum ve kablo veya proje prosed\u00fcr\u00fc kapsam\u0131ndaki tasarruf<\/td>\n<\/tr>\n<tr>\n<td>Cable cut to a new length<\/td>\n<td>What protection is required for each newly exposed end?<\/td>\n<td>The new cable-end condition, applicable sealing method and suitable cap reference<\/td>\n<\/tr>\n<tr>\n<td>Seal removed for inspection or preparation<\/td>\n<td>What is required before the end returns to storage?<\/td>\n<td>Approved replacement or resealing instructions; do not assume the removed cap is reusable<\/td>\n<\/tr>\n<tr>\n<td>Handover for installation<\/td>\n<td>Has storage protection been distinguished from the final electrical work?<\/td>\n<td>Cable condition and release record, followed by the required termination or splice documents<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>This is a handover map, not a fixed inspection interval. Storage duration, outdoor exposure, handling damage and the cable manufacturer&#8217;s requirements determine what the project needs to control.<\/p>\n<p>Retain the cable identification when an end is covered. If an end is opened or recut, the old seal record no longer establishes the condition of the new end. The replacement protection and acceptance record should refer to the cable length actually being handed over.<\/p>\n<h2>Match the Next Question to the Right Resource<\/h2>\n<p>End-cap selection and sleeve installation are related, but their dimensions and application boundaries differ. Use the resource that owns the next task.<\/p>\n<table>\n<thead>\n<tr>\n<th>Your next task<\/th>\n<th>Start here<\/th>\n<th>Keep this boundary<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Identify a cap candidate for a particular cable end<\/td>\n<td>The HSC-F or HSC-B model documents linked above<\/td>\n<td>Use the cap&#8217;s own diameter limits, usable coverage and length definitions. A tubing size chart is not a cap-selection approval.<\/td>\n<\/tr>\n<tr>\n<td>Understand the wider sleeve landscape<\/td>\n<td><a href=\"https:\/\/yocl.com\/tr\/what-is-heat-shrink-tubing\/\">Heat shrink tubing overview<\/a><\/td>\n<td>Open sleeves, ratios and wall construction are covered there; a closed end introduces another boundary.<\/td>\n<\/tr>\n<tr>\n<td>Cover an accepted electrical splice with open tubing<\/td>\n<td><a href=\"https:\/\/yocl.com\/tr\/how-to-select-and-apply-heat-shrink-tubing-to-a-cable-splice\/\">How to select and apply heat shrink tubing to a cable splice<\/a><\/td>\n<td>That procedure concerns a splice and sleeve. It is not an end-cap installation instruction.<\/td>\n<\/tr>\n<tr>\n<td>Investigate split material or unresolved sealing evidence<\/td>\n<td><a href=\"https:\/\/yocl.com\/tr\/why-heat-shrink-tubing-splits-or-fails-to-seal\/\">Why heat shrink tubing splits or fails to seal<\/a><\/td>\n<td>The article explains the separate sleeve-diagnosis task. Cap-specific rework still needs the cap&#8217;s instructions.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>For cap fit, the key document fields are the supplied internal diameter, recovered diameter limit, required cable coverage, length definitions and material\/interface suitability. They belong to one selected model and application. Do not combine a diameter from one cap with a length or wall value from another.<\/p>\n<p>Recovery is only one part of the application. Obtain the preparation, heating, cooling and acceptance instructions for the selected cap rather than treating the shared \u201c4:1\u201d label as an installation recipe. Detailed sizing and application work should follow those documents.<\/p>\n<h2>What the Cap Does Not Establish<\/h2>\n<p>A cable-end seal addresses a defined end and exposure. It does not repair a damaged jacket farther along the cable, dry a wet construction or provide conductor continuity. A material&#8217;s insulation property also does not assign a working voltage to the complete capped cable end.<\/p>\n<p>Specify environmental exposure explicitly. General moisture protection, prolonged outdoor storage, immersion, chemical exposure and pressure are different requirements. Ask for evidence covering the completed arrangement and the required conditions. The words \u201cwaterproof\u201d or \u201cadhesive-lined\u201d alone do not assign an unspecified ingress-protection class or immersion duration.<\/p>\n<p>Storage protection also needs to remain separate from electrical isolation. Before handling or applying heat to electrical cable ends, follow the authorized safe-work and isolation arrangements. The UK HSE&#8217;s <a href=\"https:\/\/www.hse.gov.uk\/pubns\/priced\/hsg85.pdf\" target=\"_blank\" rel=\"noopener\">\u0130\u015f yerinde elektrik: G\u00fcvenli \u00e7al\u0131\u015fma uygulamalar\u0131<\/a>, third edition, paragraphs 47\u201355, describes identification, isolation and proving dead. An end cap is not a replacement for those controls or an automatic authorization to energize an unused conductor.<\/p>\n<h2>Prepare a Reviewable End-Cap Enquiry<\/h2>\n<p>Provide the cable construction and jacket material, the end or feature dimensions, required coverage, intended storage or service exposure, and the proposed HSC-F or HSC-B model if one has been identified. Include colour, quantity and any project-specific sealing or documentation requirements.<\/p>\n<p>Kullan\u0131n <a href=\"https:\/\/yocl.com\/tr\/heat-shrink-tubing-manufacturer\/\">YOCL heat-shrink product range<\/a> to request the applicable cap dimensions, application instructions and evidence for the intended duty. This turns a general request for an end cap into a review of the actual cable-end interface and protection requirement.<\/p>\n<h2>Referanslar<\/h2>\n<ul>\n<li>YOCL ELEKTR\u0130K \u2014 <a href=\"https:\/\/yocl.com\/tr\/product\/hsc-f-4-1-dual-wall-heat-shrink-waterproof-end-cap\/\">HSC-F 4:1 Dual-Wall Heat Shrink End Cap<\/a>, first-party product construction, model fields and original section; accessed 27 October 2026.<\/li>\n<li>YOCL ELEKTR\u0130K \u2014 <a href=\"https:\/\/yocl.com\/tr\/product\/hsc-b-4-1-semi-rigid-dual-wall-heat-shrink-waterproof-end-cap\/\">HSC-B Semi-Rigid Dual-Wall Heat Shrink End Cap<\/a>, first-party product construction, model fields and original section; accessed 27 October 2026.<\/li>\n<li>Horizon Power \u2014 <a href=\"https:\/\/www.horizonpower.com.au\/globalassets\/media\/documents\/manuals-standards\/specifications\/hpc-8dj-03-0003-2012---spec---lv-power-cables.pdf\" target=\"_blank\" rel=\"noopener\">Specification \u2014 LV Power Cables, HPC-8DJ-03-0003-2012<\/a>, revision 4, 13 July 2026, section 3.8, cable-end sealing for its LV cable procurement scope.<\/li>\n<li>UK Health and Safety Executive \u2014 <a href=\"https:\/\/www.hse.gov.uk\/pubns\/priced\/hsg85.pdf\" target=\"_blank\" rel=\"noopener\">Electricity at work: Safe working practices, HSG85<\/a>, third edition, 2013, paragraphs 47\u201355; safe-work principles.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>A heat shrink end cap is a closed-end covering used to protect an exposed cable end. Its entry opening recovers around the cable, while an adhesive-lined design forms an interface with a suitable cable surface under the specified application process. The purpose is cable-end protection during storage, transport or a documented end-sealing application. An end [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3243,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[165],"tags":[],"class_list":["post-3244","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-heat-shrink-insulation"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/3244","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/comments?post=3244"}],"version-history":[{"count":1,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/3244\/revisions"}],"predecessor-version":[{"id":3245,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/posts\/3244\/revisions\/3245"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/3243"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=3244"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/categories?post=3244"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/tags?post=3244"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}