{"id":1431,"date":"2026-10-01T07:48:23","date_gmt":"2026-10-01T07:48:23","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=1431"},"modified":"2026-10-01T07:48:30","modified_gmt":"2026-10-01T07:48:30","slug":"bdm-17-single-compression-armored-exd-cable-gland","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/bdm-17-single-compression-armored-exd-cable-gland\/","title":{"rendered":"BDM-17 Tek S\u0131k\u0131\u015ft\u0131rmal\u0131 Z\u0131rhl\u0131 Ex d Kablo Rakoru"},"content":{"rendered":"<h2>Genel Bak\u0131\u015f<\/h2>\n<p>YOCL ELECTRIC BDM-17 Tekli S\u0131k\u0131\u015ft\u0131rmal\u0131 Z\u0131rhl\u0131 Ex d Kablo Rakoru, denizcilik uygulamalar\u0131 dahil olmak \u00fczere neme maruz kalan end\u00fcstriyel ortamlar i\u00e7in su bask\u0131n\u0131na kar\u015f\u0131 korumal\u0131 z\u0131rhl\u0131 kablo giri\u015fi sa\u011flar. Tedarik edilen \u00fcr\u00fcn a\u00e7\u0131klamas\u0131, bunu bir bariyer tipi kablo rakuru olarak tan\u0131mlamaktad\u0131r.<\/p>\n<p>It is listed for steel wire armor, steel tape armor, braid armor and marine braided cable constructions. Lead-sheathed cable applications are described with an earth tag and earth plug. Thread selection determines which Ex applications are listed: metric and NPT threads for Ex d, Ex e and Ex t; G threads for Ex e and Ex t only.<\/p>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li><strong>Single compression construction:<\/strong> Armored metal cable gland with model-specific sheath and armor data.<\/li>\n<li><strong>Deluge ingress protection:<\/strong> Designed for environments exposed to moisture and water spray.<\/li>\n<li><strong>Tooth-shaped clamping cap:<\/strong> Provides a grip surface for handling during assembly.<\/li>\n<li><strong>Body material options:<\/strong> Brass, nickel-plated brass, SS304 and SS316.<\/li>\n<li><strong>Cable compatibility:<\/strong> Listed armored and lead-sheathed cable constructions, subject to size and accessory selection.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>Teknik \u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>BDM-17<\/td>\n<\/tr>\n<tr>\n<td>Tip<\/td>\n<td>Single compression armored metal type; identified as barrier type in the supplied description<\/td>\n<\/tr>\n<tr>\n<td>Body material options<\/td>\n<td>Brass; nickel-plated brass; SS304; SS316<\/td>\n<\/tr>\n<tr>\n<td>Sealing material options<\/td>\n<td>Silicone rubber; neoprene; PTFE (Teflon); PA6<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature options<\/td>\n<td>\u221220 \u00b0C to +60 \u00b0C \/ \u221260 \u00b0C to +80 \u00b0C, depending on configuration<\/td>\n<\/tr>\n<tr>\n<td>Supplied Ex marking<\/td>\n<td>Ex db IIC Gb; Ex eb IIC Gb; Ex tb IIIC Db, subject to thread configuration<\/td>\n<\/tr>\n<tr>\n<td>Application designation<\/td>\n<td>II 2GD, as stated in the supplied specification<\/td>\n<\/tr>\n<tr>\n<td>Ingress protection<\/td>\n<td>IP66; IP68 (1 m, 1 h)<\/td>\n<\/tr>\n<tr>\n<td>Metric and NPT thread applications<\/td>\n<td>Ex d; Ex e; Ex t<\/td>\n<\/tr>\n<tr>\n<td>BSP (G) thread applications<\/td>\n<td>Ex e; Ex t only<\/td>\n<\/tr>\n<tr>\n<td>Approvals stated in supplied specification<\/td>\n<td>IECEx; ATEX; EAC (CUTR); CNEx<\/td>\n<\/tr>\n<tr>\n<td>Standards listed in supplied specification<\/td>\n<td>IEC\/EN 60079-0; IEC\/EN 60079-1; IEC\/EN 60079-31; IEC\/EN 60529<\/td>\n<\/tr>\n<tr>\n<td>Standard accessories<\/td>\n<td>Nylon washer and locknut, except for NPT versions<\/td>\n<\/tr>\n<tr>\n<td>Optional accessories<\/td>\n<td>Earth tag; PVC shroud; serrated washer; red fibre washer; A\/B putty compound<\/td>\n<\/tr>\n<tr>\n<td>Lead-sheathed cable accessory condition<\/td>\n<td>Earth tag and earth plug, as stated in the supplied description<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The temperature options are configuration-dependent. The supplied data does not map each option to a sealing material and does not provide certificate numbers. The G-thread option is not listed for Ex d use.<\/p>\n<h2>Boyut<\/h2>\n<h3>Sheath and Armor Data<\/h3>\n<p>Dimensions are in millimetres, except the NPT\/G nominal thread sizes in inches. The strict less-than limits for A and the slash-separated armor values are retained from the supplied table.<\/p>\n<table>\n<thead>\n<tr>\n<th>Size<\/th>\n<th>Metric entry thread AG<\/th>\n<th>NPT\/G nominal size (inch)<\/th>\n<th>Inner sheath A (mm)<\/th>\n<th>Outer sheath B (mm)<\/th>\n<th>Armor orientation 1 (mm)<\/th>\n<th>Armor orientation 2 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>20A<\/td>\n<td>M20\u00d71.5<\/td>\n<td>1\/2<\/td>\n<td>&lt;11<\/td>\n<td>5.5\u201312<\/td>\n<td>0.9\/1.25<\/td>\n<td>0\/0.7<\/td>\n<\/tr>\n<tr>\n<td>20B<\/td>\n<td>M20\u00d71.5<\/td>\n<td>1\/2<\/td>\n<td>&lt;11<\/td>\n<td>9.5\u201316<\/td>\n<td>0.9\/1.25<\/td>\n<td>0\/0.7<\/td>\n<\/tr>\n<tr>\n<td>20C<\/td>\n<td>M20\u00d71.5<\/td>\n<td>1\/2<\/td>\n<td>&lt;15<\/td>\n<td>12.5\u201320.5<\/td>\n<td>0.9\/1.25<\/td>\n<td>0\/0.7<\/td>\n<\/tr>\n<tr>\n<td>25B<\/td>\n<td>M25\u00d71.5<\/td>\n<td>3\/4<\/td>\n<td>&lt;15<\/td>\n<td>12.5\u201320.5<\/td>\n<td>0.9\/1.25<\/td>\n<td>0\/0.7<\/td>\n<\/tr>\n<tr>\n<td>25C<\/td>\n<td>M25\u00d71.5<\/td>\n<td>3\/4<\/td>\n<td>&lt;21<\/td>\n<td>17\u201326<\/td>\n<td>1.25\/1.6<\/td>\n<td>0\/0.7<\/td>\n<\/tr>\n<tr>\n<td>32B<\/td>\n<td>M32\u00d71.5<\/td>\n<td>1<\/td>\n<td>&lt;21<\/td>\n<td>17\u201326<\/td>\n<td>1.25\/1.6<\/td>\n<td>0\/0.7<\/td>\n<\/tr>\n<tr>\n<td>32C<\/td>\n<td>M32\u00d71.5<\/td>\n<td>1<\/td>\n<td>&lt;27<\/td>\n<td>22\u201333<\/td>\n<td>1.6\/2<\/td>\n<td>0\/0.7<\/td>\n<\/tr>\n<tr>\n<td>40B<\/td>\n<td>M40\u00d71.5<\/td>\n<td>1-1\/4<\/td>\n<td>&lt;27<\/td>\n<td>22\u201333<\/td>\n<td>1.6\/2<\/td>\n<td>0\/0.7<\/td>\n<\/tr>\n<tr>\n<td>40C<\/td>\n<td>M40\u00d71.5<\/td>\n<td>1-1\/4<\/td>\n<td>&lt;33<\/td>\n<td>28\u201341<\/td>\n<td>1.8\/2.5<\/td>\n<td>0\/0.7<\/td>\n<\/tr>\n<tr>\n<td>50B<\/td>\n<td>M50\u00d71.5<\/td>\n<td>1-1\/2<\/td>\n<td>&lt;33<\/td>\n<td>28\u201341<\/td>\n<td>1.8\/2.5<\/td>\n<td>0\/1.0<\/td>\n<\/tr>\n<tr>\n<td>50C<\/td>\n<td>M50\u00d71.5<\/td>\n<td>1-1\/2<\/td>\n<td>&lt;43<\/td>\n<td>36\u201352.6<\/td>\n<td>1.8\/2.5<\/td>\n<td>0\/1.0<\/td>\n<\/tr>\n<tr>\n<td>63B<\/td>\n<td>M63\u00d71.5<\/td>\n<td>2<\/td>\n<td>&lt;43<\/td>\n<td>36\u201352.6<\/td>\n<td>1.8\/2.5<\/td>\n<td>0\/1.0<\/td>\n<\/tr>\n<tr>\n<td>63C<\/td>\n<td>M63\u00d71.5<\/td>\n<td>2<\/td>\n<td>&lt;54.5<\/td>\n<td>46\u201365<\/td>\n<td>1.8\/2.5<\/td>\n<td>0\/1.0<\/td>\n<\/tr>\n<tr>\n<td>75B<\/td>\n<td>M75\u00d71.5<\/td>\n<td>2-1\/2<\/td>\n<td>&lt;54.5<\/td>\n<td>46\u201365<\/td>\n<td>1.8\/2.5<\/td>\n<td>0\/1.0<\/td>\n<\/tr>\n<tr>\n<td>75C<\/td>\n<td>M75\u00d71.5<\/td>\n<td>2-1\/2<\/td>\n<td>&lt;66<\/td>\n<td>57\u201378<\/td>\n<td>1.8\/2.5<\/td>\n<td>0\/1.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The armor values are listed by orientation; slash-separated entries are not rewritten as continuous min\u2013max ranges. Select the compatible armor-ring orientation for the actual cable construction. The NPT\/G column gives a nominal size; the actual thread standard and permitted Ex application must be specified separately.<\/p>\n<h3>Length Data<\/h3>\n<table>\n<thead>\n<tr>\n<th>Size<\/th>\n<th>Body length L1 (mm)<\/th>\n<th>Entry thread length L (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>20A<\/td>\n<td>70<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td>20B<\/td>\n<td>70<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td>20C<\/td>\n<td>81<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td>25B<\/td>\n<td>81<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td>25C<\/td>\n<td>91<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td>32B<\/td>\n<td>91<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>32C<\/td>\n<td>96<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>40B<\/td>\n<td>96<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>40C<\/td>\n<td>107<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>50B<\/td>\n<td>107<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>50C<\/td>\n<td>132<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>63B<\/td>\n<td>132<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td>63C<\/td>\n<td>145<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td>75B<\/td>\n<td>145<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td>75C<\/td>\n<td>154<\/td>\n<td>20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>L1 and L follow the source drawing: L1 is the body length beyond the entry thread and L is the entry thread length. No maximum external diameter D is supplied for this model.<\/p>\n<h2>Aksesuarlar ve Sipari\u015f<\/h2>\n<p>Specify BDM-17 size, body material, actual thread standard and size, inner and outer sheath diameters, armor construction and required ring orientation. Include the required Ex application and operating temperature configuration.<\/p>\n<p>For lead-sheathed cables, specify the earth tag and earth plug described for that application. Nylon washers and locknuts are standard except for NPT versions. PVC shrouds, serrated washers, red fibre washers and A\/B putty compound are listed as optional accessories.<\/p>\n<p>For a barrier configuration, specify the compatible compound system and its supply with the order. The supplied data does not define the compound formulation, curing procedure or installation torque; use the documentation for the delivered configuration.<\/p>","protected":false},"excerpt":{"rendered":"<p>Tehlikeli alan kablo giri\u015fi i\u00e7in, tedarik edilen \u00fcr\u00fcn a\u00e7\u0131klamas\u0131nda bariyer tipi olarak tan\u0131mlanan, tekli s\u0131k\u0131\u015ft\u0131rmal\u0131 z\u0131rhl\u0131 metal kablo rakoru BDM-17.<\/p>\n<ul>\n<li>Pirin\u00e7, nikel kapl\u0131 pirin\u00e7, SS304 veya SS316 g\u00f6vdeler.<\/li>\n<li>Su bask\u0131n\u0131na kar\u015f\u0131 koruma; belirtilen IP66 ve IP68 (1 m, 1 h).<\/li>\n<li>Ex d, Ex e ve Ex t i\u00e7in Metrik ve NPT; yaln\u0131zca Ex e ve Ex t i\u00e7in G di\u015f.<\/li>\n<li>Ayr\u0131 k\u0131l\u0131f ve z\u0131rh y\u00f6nlendirme verileriyle 15 boyutlar\u0131.<\/li>\n<li>NPT versiyonlar\u0131 hari\u00e7 standart olarak Naylon rondela ve kilit somunu.<\/li>\n<\/ul>","protected":false},"featured_media":1430,"template":"","meta":[],"product_brand":[],"product_cat":[157],"product_tag":[],"class_list":["post-1431","product","type-product","status-publish","has-post-thumbnail","product_cat-explosion-proof-cable-glands","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/1431","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/1430"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=1431"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=1431"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=1431"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=1431"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}