{"id":1814,"date":"2026-10-02T16:34:24","date_gmt":"2026-10-02T16:34:24","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=1814"},"modified":"2026-10-02T16:34:31","modified_gmt":"2026-10-02T16:34:31","slug":"3-1-zero-halogen-single-wall-heat-shrink-tubing","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/3-1-zero-halogen-single-wall-heat-shrink-tubing\/","title":{"rendered":"3:1 Zero-Halogen Single-Wall Heat Shrink Tubing"},"content":{"rendered":"<h2>Genel Bak\u0131\u015f<\/h2>\n<p>YOCL Elektrik <strong>3:1 Zero-Halogen Single-Wall Heat Shrink Tubing<\/strong> provides electrical insulation, cable protection, wire-harness bundling and component covering. It is manufactured from irradiated cross-linked modified polyolefin with zero-halogen and low-smoke characteristics.<\/p>\n<p>The <strong>3:1 shrink ratio<\/strong> allows the tubing to pass over a connector or terminal and recover around a smaller cable diameter. The thin single wall has no internal adhesive layer. Fourteen sizes are available from 1.5\/0.5 mm to 39\/13 mm, with an operating temperature up to <strong>125\u00b0C<\/strong>.<\/p>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li><strong>3:1 recovery range:<\/strong> Helps accommodate connectors, terminals and components during installation.<\/li>\n<li><strong>Zero-halogen formulation:<\/strong> Provides a material option for applications with halogen-content requirements.<\/li>\n<li><strong>Low-smoke characteristics:<\/strong> Supports material selection for electrical and electronic equipment.<\/li>\n<li><strong>Thin single wall:<\/strong> Provides a compact, flexible insulating cover.<\/li>\n<li><strong>Modified polyolefin construction:<\/strong> Uses irradiation cross-linking.<\/li>\n<li><strong>Electrical and mechanical properties:<\/strong> Rated voltage options, insulation test values and mechanical properties are listed below.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>Teknik \u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marka<\/td>\n<td>YOCL Elektrik<\/td>\n<\/tr>\n<tr>\n<td>\u00dcr\u00fcn tipi<\/td>\n<td>Zero-halogen single-wall heat shrink tubing<\/td>\n<\/tr>\n<tr>\n<td>Malzeme<\/td>\n<td>Irradiated cross-linked modified polyolefin<\/td>\n<\/tr>\n<tr>\n<td>Yap\u0131<\/td>\n<td>Single wall \/ thin wall<\/td>\n<\/tr>\n<tr>\n<td>Internal adhesive layer<\/td>\n<td>None<\/td>\n<\/tr>\n<tr>\n<td>Shrink ratio<\/td>\n<td>3:1<\/td>\n<\/tr>\n<tr>\n<td>\u00c7al\u0131\u015fma s\u0131cakl\u0131\u011f\u0131<\/td>\n<td>Up to 125\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Rated voltage options<\/td>\n<td>300 V \/ 600 V<\/td>\n<\/tr>\n<tr>\n<td>Longitudinal shrinkage<\/td>\n<td>-5% to +5%<\/td>\n<\/tr>\n<tr>\n<td>Tensile strength<\/td>\n<td>\u226510.4 MPa<\/td>\n<\/tr>\n<tr>\n<td>Elongation at break<\/td>\n<td>\u2265200%<\/td>\n<\/tr>\n<tr>\n<td>Tensile strength after heat aging<\/td>\n<td>\u22657.3 MPa<\/td>\n<\/tr>\n<tr>\n<td>Elongation after heat aging<\/td>\n<td>\u2265100%<\/td>\n<\/tr>\n<tr>\n<td>Volume resistivity<\/td>\n<td>\u22651.0 \u00d7 10\u00b9\u00b2 \u03a9\u00b7cm<\/td>\n<\/tr>\n<tr>\n<td>Dielectric test<\/td>\n<td>2500 V for 60 seconds; no breakdown<\/td>\n<\/tr>\n<tr>\n<td>Concentricity<\/td>\n<td>\u226570%<\/td>\n<\/tr>\n<tr>\n<td>Heat-shock test condition<\/td>\n<td>250\u00b0C \u00b13\u00b0C for 4 hours<\/td>\n<\/tr>\n<tr>\n<td>Heat-shock test result<\/td>\n<td>No dripping, cracking or flowing<\/td>\n<\/tr>\n<tr>\n<td>Flammability specification*<\/td>\n<td>UL224 VW-1<\/td>\n<\/tr>\n<tr>\n<td>Halogen content<\/td>\n<td>Zero halogen<\/td>\n<\/tr>\n<tr>\n<td>Smoke characteristics<\/td>\n<td>Low smoke<\/td>\n<\/tr>\n<tr>\n<td>Environmental compliance*<\/td>\n<td>RoHS \/ REACH<\/td>\n<\/tr>\n<tr>\n<td>Number of listed sizes<\/td>\n<td>14<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>*UL224 VW-1 flame performance and RoHS \/ REACH conformity are subject to the applicable documentation for the specific material supplied.<\/p>\n<p>The 250\u00b0C condition is a heat-shock test condition. The stated operating temperature limit is 125\u00b0C.<\/p>\n<h2>Boyut<\/h2>\n<table>\n<thead>\n<tr>\n<th>Size (mm)<\/th>\n<th>Min. I.D. as supplied (mm)<\/th>\n<th>Wall as supplied (mm)<\/th>\n<th>Max. I.D. after recovery (mm)<\/th>\n<th>Wall after recovery (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1.5\/0.5<\/td>\n<td>1.5<\/td>\n<td>0.18<\/td>\n<td>0.5<\/td>\n<td>0.40 \u00b1 0.10<\/td>\n<\/tr>\n<tr>\n<td>2.4\/0.8<\/td>\n<td>2.4<\/td>\n<td>0.20<\/td>\n<td>0.8<\/td>\n<td>0.48 \u00b1 0.06<\/td>\n<\/tr>\n<tr>\n<td>3.0\/1.0<\/td>\n<td>3.0<\/td>\n<td>0.20<\/td>\n<td>1.0<\/td>\n<td>0.55 \u00b1 0.12<\/td>\n<\/tr>\n<tr>\n<td>4.5\/1.5<\/td>\n<td>4.5<\/td>\n<td>0.20<\/td>\n<td>1.5<\/td>\n<td>0.55 \u00b1 0.12<\/td>\n<\/tr>\n<tr>\n<td>6.0\/2.0<\/td>\n<td>6.0<\/td>\n<td>0.22<\/td>\n<td>2.0<\/td>\n<td>0.60 \u00b1 0.12<\/td>\n<\/tr>\n<tr>\n<td>9.0\/3.0<\/td>\n<td>9.0<\/td>\n<td>0.25<\/td>\n<td>3.0<\/td>\n<td>0.70 \u00b1 0.15<\/td>\n<\/tr>\n<tr>\n<td>12.0\/4.0<\/td>\n<td>12.0<\/td>\n<td>0.25<\/td>\n<td>4.0<\/td>\n<td>0.70 \u00b1 0.15<\/td>\n<\/tr>\n<tr>\n<td>15.0\/5.0<\/td>\n<td>15.0<\/td>\n<td>0.25<\/td>\n<td>5.0<\/td>\n<td>0.70 \u00b1 0.15<\/td>\n<\/tr>\n<tr>\n<td>18.0\/6.0<\/td>\n<td>18.0<\/td>\n<td>0.30<\/td>\n<td>6.0<\/td>\n<td>0.80 \u00b1 0.15<\/td>\n<\/tr>\n<tr>\n<td>20.0\/6.7<\/td>\n<td>20.0<\/td>\n<td>0.30<\/td>\n<td>6.7<\/td>\n<td>0.80 \u00b1 0.15<\/td>\n<\/tr>\n<tr>\n<td>24.0\/8.0<\/td>\n<td>24.0<\/td>\n<td>0.36<\/td>\n<td>8.0<\/td>\n<td>1.00 \u00b1 0.15<\/td>\n<\/tr>\n<tr>\n<td>30.0\/10.0<\/td>\n<td>30.0<\/td>\n<td>0.36<\/td>\n<td>10.0<\/td>\n<td>1.00 \u00b1 0.15<\/td>\n<\/tr>\n<tr>\n<td>31.8\/10.5<\/td>\n<td>31.8<\/td>\n<td>0.36<\/td>\n<td>10.5<\/td>\n<td>1.00 \u00b1 0.15<\/td>\n<\/tr>\n<tr>\n<td>39.0\/13.0<\/td>\n<td>39.0<\/td>\n<td>0.45<\/td>\n<td>13.0<\/td>\n<td>1.25 \u00b1 0.20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>I.D. means internal diameter. All diameters, wall thicknesses and wall tolerances are in millimetres. Supplied dimensions and fully recovered dimensions apply to the same size row.<\/p>\n<h2>Se\u00e7im K\u0131lavuzu<\/h2>\n<p>Select a supplied internal diameter that can pass over the cable, connector or component. Check the maximum recovered internal diameter against the area to be covered, together with the recovered wall thickness.<\/p>\n<p>For example, the 12.0\/4.0 mm option has a minimum supplied I.D. of 12.0 mm and a maximum recovered I.D. of 4.0 mm. Its recovered wall thickness is 0.70 \u00b1 0.15 mm.<\/p>\n<p>Specify the required 300 V or 600 V rated option with the selected tubing size. Use the dimensions in the table to assess fit and the available installation space.<\/p>\n<h2>Uygulamalar<\/h2>\n<ul>\n<li>Automotive wire harnesses and appliance wiring.<\/li>\n<li>Electrical and electronic equipment insulation.<\/li>\n<li>Wire and cable repair, joints and branches.<\/li>\n<li>Cable identification and component covering.<\/li>\n<\/ul>\n<h2>Kurulum Notlar\u0131<\/h2>\n<ol>\n<li>Select a tubing size that can pass over the cable, terminal or component.<\/li>\n<li>Cut it to the required length and slide it into position.<\/li>\n<li>Apply controlled heat evenly around the tubing.<\/li>\n<li>Move the heat source continuously to promote uniform recovery.<\/li>\n<li>Continue heating until the tubing has recovered around the component.<\/li>\n<li>Allow it to cool before handling.<\/li>\n<\/ol>\n<p>Avoid overheating or concentrating heat at one location.<\/p>\n<h2>Sipari\u015f Bilgileri<\/h2>\n<p>Specify <strong>3:1 Zero-Halogen Single-Wall Heat Shrink Tubing<\/strong>, the paired size, required voltage option and quantity when making an enquiry to YOCL Electric. Include any UL224 VW-1, RoHS or REACH documentation requirements for the material to be supplied.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL Electric 3:1 Zero-Halogen Single-Wall Heat Shrink Tubing provides electrical insulation, cable protection and component covering.<\/p>\n<ul>\n<li>Irradiated cross-linked modified polyolefin with a zero-halogen, low-smoke formulation.<\/li>\n<li>3:1 shrink ratio for recovery around cables and components.<\/li>\n<li>Thin single wall with no internal adhesive layer.<\/li>\n<li>Fourteen sizes from 1.5\/0.5 mm to 39\/13 mm.<\/li>\n<li>Operating temperature up to 125\u00b0C; 300 V and 600 V rated options.<\/li>\n<\/ul>","protected":false},"featured_media":1813,"template":"","meta":[],"product_brand":[],"product_cat":[139],"product_tag":[],"class_list":["post-1814","product","type-product","status-publish","has-post-thumbnail","product_cat-single-wall-heat-shrink-tubing","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/1814","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/1813"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=1814"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=1814"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=1814"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=1814"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}