{"id":1982,"date":"2026-10-03T18:11:08","date_gmt":"2026-10-03T18:11:08","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=1982"},"modified":"2026-10-03T18:11:40","modified_gmt":"2026-10-03T18:11:40","slug":"k-series-din-rail-distribution-terminal-blocks","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/k-series-din-rail-distribution-terminal-blocks\/","title":{"rendered":"K Serisi DIN Rayl\u0131 Da\u011f\u0131t\u0131m Terminal Bloklar\u0131"},"content":{"rendered":"<h2>Genel Bak\u0131\u015f<\/h2>\n<p><strong>YOCL Electric K Series DIN rail distribution terminal blocks<\/strong> provide multiple conductor connection points in an insulated assembly for electrical panels, distribution boards and control cabinets.<\/p>\n<p>The series includes <strong>K207, K211, K215, K407, K411 and K415<\/strong>. K207, K211 and K215 form the 2-way group with a <strong>46 mm<\/strong> housing width. K407, K411 and K415 form the 4-way group with an <strong>86 mm<\/strong> housing width. All six models have a listed height of <strong>51 mm<\/strong>.<\/p>\n<p>The blue terminal assemblies use <strong>brass conductive parts<\/strong> and <strong>PC\/PA insulating materials<\/strong>. Select the configuration, connection-hole arrangement and dimensions to suit the panel wiring layout.<\/p>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li><strong>DIN rail mounting<\/strong> for panel and cabinet installation.<\/li>\n<li><strong>2-way and 4-way configurations<\/strong> across six models.<\/li>\n<li><strong>Multiple connection-hole diameters:<\/strong> \u00d86 mm, \u00d87.5 mm and \u00d89 mm, depending on model.<\/li>\n<li><strong>Brass conductive parts<\/strong> within PC\/PA insulation.<\/li>\n<li><strong>UL94 V-2 material classification<\/strong> for the PC and PA insulating materials.<\/li>\n<li><strong>Two housing widths<\/strong> and three lengths to suit different wiring layouts.<\/li>\n<li><strong>250\u2013450 V voltage range<\/strong>.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>Teknik \u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marka<\/td>\n<td>YOCL Elektrik<\/td>\n<\/tr>\n<tr>\n<td>Seri<\/td>\n<td>K<\/td>\n<\/tr>\n<tr>\n<td>\u00dcr\u00fcn tipi<\/td>\n<td>DIN rail distribution terminal block<\/td>\n<\/tr>\n<tr>\n<td>Montaj<\/td>\n<td>DIN rail<\/td>\n<\/tr>\n<tr>\n<td>Voltage range<\/td>\n<td>250\u2013450 V<\/td>\n<\/tr>\n<tr>\n<td>Conductive parts<\/td>\n<td>Brass<\/td>\n<\/tr>\n<tr>\n<td>Insulating materials<\/td>\n<td>PC \/ PA<\/td>\n<\/tr>\n<tr>\n<td>PA material<\/td>\n<td>Nylon 66<\/td>\n<\/tr>\n<tr>\n<td>Material flammability rating<\/td>\n<td>UL94 V-2, for PC and PA<\/td>\n<\/tr>\n<tr>\n<td>Color<\/td>\n<td>Blue<\/td>\n<\/tr>\n<tr>\n<td>Configuration groups<\/td>\n<td>2-way \/ 4-way<\/td>\n<\/tr>\n<tr>\n<td>Modeller<\/td>\n<td>K207, K211, K215, K407, K411, K415<\/td>\n<\/tr>\n<tr>\n<td>Connection-hole diameters<\/td>\n<td>\u00d86 mm \/ \u00d87.5 mm \/ \u00d89 mm; model dependent<\/td>\n<\/tr>\n<tr>\n<td>Housing widths<\/td>\n<td>46 mm \/ 86 mm; model dependent<\/td>\n<\/tr>\n<tr>\n<td>Housing lengths<\/td>\n<td>66 mm \/ 103 mm \/ 134 mm; model dependent<\/td>\n<\/tr>\n<tr>\n<td>Housing height<\/td>\n<td>51 mm<\/td>\n<\/tr>\n<tr>\n<td>Dimension format<\/td>\n<td>Width \u00d7 length \u00d7 height (W \u00d7 L \u00d7 H), mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Model Specifications<\/h3>\n<p>Connection-hole diameters are in <strong>millimeters<\/strong>. Housing dimensions are listed as <strong>width (W), length (L) and height (H)<\/strong>.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Connection-hole specification<\/th>\n<th>Configuration<\/th>\n<th>Width W<\/th>\n<th>Length L<\/th>\n<th>Height H<\/th>\n<th>Insulating materials<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>K207<\/td>\n<td>5 \u00d7 \u00d86 + 2 \u00d7 \u00d87.5<\/td>\n<td>2 \u00d7 7<\/td>\n<td>46 mm<\/td>\n<td>66 mm<\/td>\n<td>51 mm<\/td>\n<td>PC \/ PA<\/td>\n<\/tr>\n<tr>\n<td>K211<\/td>\n<td>7 \u00d7 \u00d86 + 2 \u00d7 \u00d87.5 + 2 \u00d7 \u00d89<\/td>\n<td>2 \u00d7 11<\/td>\n<td>46 mm<\/td>\n<td>103 mm<\/td>\n<td>51 mm<\/td>\n<td>PC \/ PA<\/td>\n<\/tr>\n<tr>\n<td>K215<\/td>\n<td>11 \u00d7 \u00d86 + 2 \u00d7 \u00d87.5 + 2 \u00d7 \u00d89<\/td>\n<td>2 \u00d7 15<\/td>\n<td>46 mm<\/td>\n<td>134 mm<\/td>\n<td>51 mm<\/td>\n<td>PC \/ PA<\/td>\n<\/tr>\n<tr>\n<td>K407<\/td>\n<td>4 \u00d7 \u00d86 + 2 \u00d7 \u00d87.5<\/td>\n<td>4 \u00d7 7<\/td>\n<td>86 mm<\/td>\n<td>66 mm<\/td>\n<td>51 mm<\/td>\n<td>PC \/ PA<\/td>\n<\/tr>\n<tr>\n<td>K411<\/td>\n<td>7 \u00d7 \u00d86 + 2 \u00d7 \u00d87.5 + 2 \u00d7 \u00d89<\/td>\n<td>4 \u00d7 11<\/td>\n<td>86 mm<\/td>\n<td>103 mm<\/td>\n<td>51 mm<\/td>\n<td>PC \/ PA<\/td>\n<\/tr>\n<tr>\n<td>K415<\/td>\n<td>11 \u00d7 \u00d86 + 2 \u00d7 \u00d87.5 + 2 \u00d7 \u00d89<\/td>\n<td>4 \u00d7 15<\/td>\n<td>86 mm<\/td>\n<td>134 mm<\/td>\n<td>51 mm<\/td>\n<td>PC \/ PA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Configuration and Panel Layout<\/h2>\n<h3>K2 Group: 46 mm Width<\/h3>\n<p><strong>K207, K211 and K215<\/strong> use 2-way configurations. Their listed configurations are <strong>2 \u00d7 7<\/strong>, <strong>2 \u00d7 11<\/strong> and <strong>2 \u00d7 15<\/strong>, respectively. Housing length increases from <strong>66 mm<\/strong> to <strong>103 mm<\/strong> to <strong>134 mm<\/strong>, while width remains <strong>46 mm<\/strong> and height remains <strong>51 mm<\/strong>.<\/p>\n<h3>K4 Group: 86 mm Width<\/h3>\n<p><strong>K407, K411 and K415<\/strong> use 4-way configurations. Their listed configurations are <strong>4 \u00d7 7<\/strong>, <strong>4 \u00d7 11<\/strong> and <strong>4 \u00d7 15<\/strong>, respectively. Housing lengths are <strong>66 mm<\/strong>, <strong>103 mm<\/strong> and <strong>134 mm<\/strong>, with a common width of <strong>86 mm<\/strong> and height of <strong>51 mm<\/strong>.<\/p>\n<p>Use the model table to compare the configuration and connection-hole specification for the chosen assembly.<\/p>\n<h2>Insulating Materials<\/h2>\n<p>The insulating materials are <strong>PC and PA<\/strong>, ile <strong>PA specified as Nylon 66<\/strong>. Both materials have a listed <strong>UL94 V-2 flammability classification<\/strong>.<\/p>\n<p>The following working-temperature values describe the insulating materials:<\/p>\n<table>\n<thead>\n<tr>\n<th>Insulating material<\/th>\n<th>Material working-temperature range<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>PA<\/td>\n<td>-40\u00b0C to +110\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>PC<\/td>\n<td>-35\u00b0C to +120\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Material temperature data should be considered alongside the requirements for the complete terminal assembly and its installation environment.<\/p>\n<h2>Se\u00e7im K\u0131lavuzu<\/h2>\n<ol>\n<li><strong>Choose the configuration group.<\/strong> Select the listed 2-way or 4-way arrangement for the wiring layout.<\/li>\n<li><strong>Compare connection-hole specifications.<\/strong> Check the hole diameters and arrangement for the selected model.<\/li>\n<li><strong>Check panel space.<\/strong> Compare W \u00d7 L \u00d7 H dimensions with the available space on the DIN rail.<\/li>\n<li><strong>Check circuit requirements.<\/strong> Include the operating voltage and conductor requirements in the enquiry.<\/li>\n<li><strong>Specify the model.<\/strong> Provide the exact K207, K211, K215, K407, K411 or K415 reference when ordering.<\/li>\n<\/ol>\n<p>Connection-hole diameters are mechanical dimensions. Select the conductor cross-section using the confirmed conductor capacity for the chosen terminal assembly.<\/p>\n<h2>Uygulamalar<\/h2>\n<ul>\n<li>Electrical distribution boards<\/li>\n<li>Industrial control panels and control cabinets<\/li>\n<li>DIN rail wiring assemblies<\/li>\n<li>Branch wiring and conductor grouping<\/li>\n<li>Panel building and OEM electrical assemblies<\/li>\n<\/ul>\n<h2>Sipari\u015f Bilgileri<\/h2>\n<p>\u0130leti\u015fim <strong>YOCL Elektrik<\/strong> with the required <strong>K Series model<\/strong>, <strong>yap\u0131land\u0131rma<\/strong>, <strong>connection-hole arrangement<\/strong>, <strong>operating voltage<\/strong> and <strong>quantity<\/strong>. Include any conductor and panel-layout requirements so the selected assembly can be matched to the installation.<\/p>\n<p>The model determines the housing dimensions and connection arrangement shown in the specification table.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL Electric K Series DIN rail distribution terminal blocks group conductor connections inside electrical panels and control cabinets. Six blue models combine brass conductive parts with PC\/PA insulation and offer 2-way or 4-way configurations. Choose the model by its connection-hole arrangement and housing dimensions, with widths of 46 mm or 86 mm and lengths of 66 mm, 103 mm or 134 mm.<\/p>\n<ul>\n<li>Six models: K207, K211, K215, K407, K411 and K415<\/li>\n<li>DIN rail mounting<\/li>\n<li>Brass conductive parts with PC\/PA insulation<\/li>\n<li>Voltage range: 250\u2013450 V<\/li>\n<\/ul>","protected":false},"featured_media":1981,"template":"","meta":[],"product_brand":[],"product_cat":[29],"product_tag":[],"class_list":["post-1982","product","type-product","status-publish","has-post-thumbnail","product_cat-modular-distribution-blocks","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/1982","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/1981"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=1982"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=1982"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=1982"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=1982"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}