{"id":2807,"date":"2026-10-07T11:40:08","date_gmt":"2026-10-07T11:40:08","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2807"},"modified":"2026-10-07T11:40:18","modified_gmt":"2026-10-07T11:40:18","slug":"lp-24-quick-lock-waterproof-circular-connectors","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/lp-24-quick-lock-waterproof-circular-connectors\/","title":{"rendered":"LP-24 H\u0131zl\u0131 Kilitli Su Ge\u00e7irmez Yuvarlak Konnekt\u00f6rler"},"content":{"rendered":"<h2>Genel Bak\u0131\u015f<\/h2>\n<p>YOCL ELEKTR\u0130KL\u0130 LP-24 H\u0131zl\u0131 Kilitli Su Ge\u00e7irmez Yuvarlak Konnekt\u00f6rler, ayr\u0131labilir elektrik aray\u00fczleri sa\u011flar <strong>2, 3, 4, 5 veya 6 kontaklar<\/strong>. Seri, iletken konfig\u00fcrasyonlar\u0131n\u0131 \u015funlardan listeler: <strong>2.5\u20134.0 mm\u00b2<\/strong> ile <strong>6.0\u20138.0 mm\u00b2<\/strong>, se\u00e7ilen kontak grubuna ve kablolama konfig\u00fcrasyonuna g\u00f6re e\u015fle\u015ftirilmi\u015f ak\u0131m de\u011ferleriyle.<\/p>\n<p>Bir basmal\u0131 d\u00fc\u011fme ge\u00e7meli kilit, tek elle takmay\u0131 ve \u00e7\u0131karmay\u0131 destekler. Vidal\u0131 kelep\u00e7e terminalleri iletkenleri ba\u011flar ve kablo fi\u015fleri, s\u0131ral\u0131 kenetleme soketleri ve iki panel soketi format\u0131 erkek ve di\u015fi kontak se\u00e7enekleriyle listelenmi\u015ftir. Katalog belirtir <strong>ba\u011fl\u0131 durumda IP68 koruma<\/strong>.<\/p>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li><strong>Basmal\u0131 d\u00fc\u011fme ge\u00e7meli kilit:<\/strong> Tek elle takmay\u0131 ve \u00e7\u0131karmay\u0131 destekler.<\/li>\n<li><strong>ba\u011fl\u0131 durumda IP68:<\/strong> Koruma, birle\u015ftirilmi\u015f konekt\u00f6r grubuna uygulan\u0131r.<\/li>\n<li><strong>Kablo ve panel formatlar\u0131:<\/strong> Kablo fi\u015fleri, s\u0131ral\u0131 kenetleme soketleri, tek delikli panel soketleri ve d\u00f6rt delikli flan\u015f soketleri listelenmi\u015ftir.<\/li>\n<li><strong>Erkek ve di\u015fi kontaklar:<\/strong> Ba\u011flant\u0131n\u0131n her iki taraf\u0131 i\u00e7in elektrik konta\u011f\u0131 cinsiyetini se\u00e7in.<\/li>\n<li><strong>Vida kelep\u00e7eli sonland\u0131rma:<\/strong> \u0130letkenler vidal\u0131 ba\u011flant\u0131 ile sabitlenir.<\/li>\n<li><strong>Kaplamal\u0131 bak\u0131r ala\u015f\u0131ml\u0131 kontaklar:<\/strong> Nikel alt kaplama \u00fczerine alt\u0131n kaplama belirtilmi\u015ftir.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>Teknik \u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marka<\/td>\n<td>YOCL ELEKTR\u0130K<\/td>\n<\/tr>\n<tr>\n<td>Seri<\/td>\n<td>LP-24<\/td>\n<\/tr>\n<tr>\n<td>Konnekt\u00f6r tipi<\/td>\n<td>H\u0131zl\u0131 kilitli su ge\u00e7irmez dairesel konnekt\u00f6r<\/td>\n<\/tr>\n<tr>\n<td>Kontak say\u0131s\u0131<\/td>\n<td>2 \/ 3 \/ 4 \/ 5 \/ 6<\/td>\n<\/tr>\n<tr>\n<td>Kilitleme y\u00f6ntemi<\/td>\n<td>D\u00fc\u011fmeli ge\u00e7meli kilit<\/td>\n<\/tr>\n<tr>\n<td>Tel sonland\u0131rma<\/td>\n<td>Vida kelep\u00e7esi<\/td>\n<\/tr>\n<tr>\n<td>Kontak cinsiyeti<\/td>\n<td>Erkek \/ di\u015fi<\/td>\n<\/tr>\n<tr>\n<td>Konnekt\u00f6r formatlar\u0131<\/td>\n<td>Kablo fi\u015fi; s\u0131ral\u0131 kenetleme soketi; tek delikli panel soketi; d\u00f6rt delikli flan\u015f soketi<\/td>\n<\/tr>\n<tr>\n<td>Giri\u015f korumas\u0131<\/td>\n<td>ba\u011fl\u0131 durumda IP68<\/td>\n<\/tr>\n<tr>\n<td>Kontak malzemesi<\/td>\n<td>Bak\u0131r ala\u015f\u0131m\u0131<\/td>\n<\/tr>\n<tr>\n<td>Kontak kaplamas\u0131<\/td>\n<td>Nikel alt kaplama \u00fczerine alt\u0131n kaplama<\/td>\n<\/tr>\n<tr>\n<td>Yal\u0131tkan<\/td>\n<td>M\u00fchendislik plasti\u011fi<\/td>\n<\/tr>\n<tr>\n<td>G\u00f6vde yap\u0131s\u0131<\/td>\n<td>Yap\u0131land\u0131rmaya ba\u011fl\u0131 olarak m\u00fchendislik plasti\u011fi \/ metal<\/td>\n<\/tr>\n<tr>\n<td>Metal g\u00f6vde y\u00fczey kaplamas\u0131<\/td>\n<td>Krom kaplama<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Ak\u0131m ve \u0130letken Konfig\u00fcrasyonlar\u0131<\/h3>\n<table>\n<thead>\n<tr>\n<th>Kontak grubu<\/th>\n<th>Listelenen ak\u0131m<\/th>\n<th>\u0130letken kesiti<\/th>\n<th>Katalog AWG giri\u015fi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2 \/ 3 \/ 4<\/td>\n<td>25 A<\/td>\n<td>2.5\u20134.0 mm\u00b2<\/td>\n<td>14\u201312 AWG<\/td>\n<\/tr>\n<tr>\n<td>2 \/ 3 \/ 4<\/td>\n<td>30 A<\/td>\n<td>6.0\u20138.0 mm\u00b2<\/td>\n<td>10\u20138 AWG<\/td>\n<\/tr>\n<tr>\n<td>5 \/ 6<\/td>\n<td>10 A<\/td>\n<td>2.5\u20134.0 mm\u00b2<\/td>\n<td>14\u201312 AWG<\/td>\n<\/tr>\n<tr>\n<td>5 \/ 6<\/td>\n<td>10 A<\/td>\n<td>6.0\u20138.0 mm\u00b2<\/td>\n<td>10\u20138 AWG<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Her kontak grubu i\u00e7inde birden fazla iletken konfig\u00fcrasyonu listelenmi\u015ftir. A\u015fa\u011f\u0131daki sipari\u015f kodlar\u0131 hangi konfig\u00fcrasyonun tedarik edildi\u011fini belirtmez. Sipari\u015f verirken gerekli ak\u0131m, voltaj ve iletken kesitini birlikte belirtin. Bu tabloda atanm\u0131\u015f bir nominal voltaj yoktur. Metrik iletken kesitleri ve AWG giri\u015fleri katalog verisi olarak saklan\u0131r.<\/p>\n<h3>Kablo D\u0131\u015f \u00c7ap Se\u00e7enekleri<\/h3>\n<table>\n<thead>\n<tr>\n<th>Se\u00e7im<\/th>\n<th>Listelenen se\u00e7enekler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Kablo k\u0131l\u0131f\u0131 \u00e7ap\u0131<\/td>\n<td>\u00d85.0\u20137.0 \/ \u00d87.0\u201310.5 \/ \u00d810.5\u201314.0 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Kablo k\u0131l\u0131f\u0131 \u00e7ap\u0131 ve iletken kesiti ayr\u0131 se\u00e7im kriterleridir. \u00c7ap aral\u0131klar\u0131 seri d\u00fczeyinde se\u00e7eneklerdir ve bireysel kontak say\u0131lar\u0131na atanmaz.<\/p>\n<h2>Boyut<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/lp-24-quick-lock-waterproof-circular-connectors-dimension.webp\" alt=\"LP-24 H\u0131zl\u0131 Kilitli Su Ge\u00e7irmez Yuvarlak Konnekt\u00f6rler boyut \u00e7izimi\"><\/p>\n<table>\n<thead>\n<tr>\n<th>Boyut<\/th>\n<th>De\u011fer<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Kablo fi\u015fi uzunlu\u011fu, REF<\/td>\n<td>72.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Soket hat uzunlu\u011fu, REF<\/td>\n<td>71.3 mm<\/td>\n<\/tr>\n<tr>\n<td>Tek delikli soket montaj vidas\u0131<\/td>\n<td>M25 \u00d7 1.5<\/td>\n<\/tr>\n<tr>\n<td>Flan\u015f g\u00f6vdesi yatay geni\u015fli\u011fi<\/td>\n<td>33.0 \u00b1 0.3 mm<\/td>\n<\/tr>\n<tr>\n<td>Flan\u015f g\u00f6vdesi delik aral\u0131\u011f\u0131<\/td>\n<td>26.0 \u00b1 0.15 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>REF<\/strong> \u00e7izimlerde referans uzunluklar\u0131 belirtir. Flan\u015f boyutlar\u0131 konekt\u00f6r g\u00f6vdesini tan\u0131mlar. Panel kesikleri ve toleranslar\u0131 i\u00e7in se\u00e7ilen soketin kurulum \u00e7izimini kullan\u0131n.<\/p>\n<h2>Konekt\u00f6r Formatlar\u0131<\/h2>\n<table>\n<thead>\n<tr>\n<th>Format<\/th>\n<th>D\u00fczenleme<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Kablo fi\u015fi<\/td>\n<td>Kablolu e\u015fle\u015fen konekt\u00f6r<\/td>\n<\/tr>\n<tr>\n<td>S\u0131ral\u0131 kenetleme soketi<\/td>\n<td>S\u0131ral\u0131 ba\u011flant\u0131 i\u00e7in kablo sonland\u0131rmal\u0131 soket<\/td>\n<\/tr>\n<tr>\n<td>Tek delikli panel soketi<\/td>\n<td>Bir panel a\u00e7\u0131kl\u0131\u011f\u0131ndan monte edilen ekipman soketi<\/td>\n<\/tr>\n<tr>\n<td>D\u00f6rt delikli flan\u015f soketi<\/td>\n<td>D\u00f6rt delikli montaj flan\u015f\u0131na sahip ekipman soketi<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Erkek ve di\u015fi, \u015funlar\u0131 ifade eder <strong>elektriksel temas cinsiyeti<\/strong>. E\u015fle\u015fen bir \u00e7ift se\u00e7erken konekt\u00f6r format\u0131n\u0131 ve kontak cinsiyetini ayr\u0131 ayr\u0131 belirtin.<\/p>\n<h2>Sipari\u015f Kodu K\u0131lavuzu<\/h2>\n<p>Katalogda \u015funlar listelenmi\u015ftir <strong>40 par\u00e7a numaralar\u0131<\/strong> LP-24 i\u00e7in. A\u015fa\u011f\u0131daki kal\u0131plardaki <strong>nn<\/strong> yerine \u015funlar\u0131 kullan\u0131n <strong>02 \/ 03 \/ 04 \/ 05 \/ 06<\/strong>. nn harfleri, sipari\u015f edilebilir bir kod de\u011fil, bir kontak say\u0131s\u0131 yer tutucusudur. Ekleyin <strong>LP-24-<\/strong> Her desene \u00f6nek.<\/p>\n<table>\n<thead>\n<tr>\n<th>Format<\/th>\n<th>Kontak cinsiyeti<\/th>\n<th>Seri \u00f6nekini takip eden kod<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Kablo fi\u015fi<\/td>\n<td>Erkek<\/td>\n<td>CnnPE-11-001<\/td>\n<\/tr>\n<tr>\n<td>Kablo fi\u015fi<\/td>\n<td>Di\u015fi<\/td>\n<td>JnnPE-11-001<\/td>\n<\/tr>\n<tr>\n<td>S\u0131ral\u0131 kenetleme soketi<\/td>\n<td>Erkek<\/td>\n<td>CnnPP-11-001<\/td>\n<\/tr>\n<tr>\n<td>S\u0131ral\u0131 kenetleme soketi<\/td>\n<td>Di\u015fi<\/td>\n<td>JnnPP-11-001<\/td>\n<\/tr>\n<tr>\n<td>Tek delikli panel soketi<\/td>\n<td>Erkek<\/td>\n<td>CnnSX-11-101<\/td>\n<\/tr>\n<tr>\n<td>Tek delikli panel soketi<\/td>\n<td>Di\u015fi<\/td>\n<td>JnnSX-11-101<\/td>\n<\/tr>\n<tr>\n<td>D\u00f6rt delikli flan\u015f soketi<\/td>\n<td>Erkek<\/td>\n<td>CnnSX-11-401<\/td>\n<\/tr>\n<tr>\n<td>D\u00f6rt delikli flan\u015f soketi<\/td>\n<td>Di\u015fi<\/td>\n<td>JnnSX-11-401<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Listelenen par\u00e7a numaralar\u0131na \u00f6rnekler:<\/p>\n<ul>\n<li><strong>LP-24-C02PE-11-001:<\/strong> \u0130ki kontakl\u0131, erkek kablo fi\u015fi.<\/li>\n<li><strong>LP-24-J06PE-11-001:<\/strong> Alt\u0131 kontakl\u0131, di\u015fi kablo fi\u015fi.<\/li>\n<li><strong>LP-24-C03PP-11-001:<\/strong> \u00dc\u00e7 kontakl\u0131, erkek s\u0131ral\u0131 kenetleme soketi.<\/li>\n<li><strong>LP-24-J04SX-11-101:<\/strong> D\u00f6rt kontakl\u0131, di\u015fi tek delikli panel soketi.<\/li>\n<li><strong>LP-24-J06SX-11-401:<\/strong> Alt\u0131 kontakl\u0131, di\u015fi d\u00f6rt delikli flan\u015f soket.<\/li>\n<\/ul>\n<p>Her iki panel format\u0131 da <strong>SX<\/strong>. kullan\u0131r. Son ek <strong>101<\/strong> tek delikli bir soketi; <strong>401<\/strong> bir flan\u015f soketini belirtir. Kod, kontak say\u0131s\u0131n\u0131, format\u0131 ve elektrik konta\u011f\u0131n\u0131n cinsiyetini belirtir. Elektrik konfig\u00fcrasyonunu ve kablo \u00e7ap\u0131n\u0131 ayr\u0131 olarak sorguya dahil edin.<\/p>\n<h2>Se\u00e7im K\u0131lavuzu<\/h2>\n<ol>\n<li>Gerekli kontak say\u0131s\u0131n\u0131 se\u00e7in.<\/li>\n<li>E\u015fle\u015fen \u00e7iftin her iki taraf\u0131 i\u00e7in konekt\u00f6r format\u0131n\u0131 ve elektrik konta\u011f\u0131n\u0131n cinsiyetini se\u00e7in.<\/li>\n<li>\u0130letken kesitini ve kablo k\u0131l\u0131f\u0131 \u00e7ap\u0131n\u0131 se\u00e7ilen yap\u0131land\u0131rmaya uydurun.<\/li>\n<li>Se\u00e7ilen par\u00e7a numaras\u0131 i\u00e7in ge\u00e7erli voltaj de\u011ferini ve ak\u0131m\/iletken yap\u0131land\u0131rmas\u0131n\u0131 al\u0131n; kod tek ba\u015f\u0131na e\u015fle\u015ftirilmi\u015f yap\u0131land\u0131rmalar\u0131 ay\u0131rt etmez.<\/li>\n<li>Panel d\u00fczeni i\u00e7in se\u00e7ilen soketin \u00e7izimini kullan\u0131n. IP68 ba\u011fl\u0131 d\u00fczene\u011fi kapsar.<\/li>\n<\/ol>\n<h2>Uygulamalar<\/h2>\n<ul>\n<li>Ayr\u0131labilir ekipman g\u00fc\u00e7 ba\u011flant\u0131lar\u0131.<\/li>\n<li>\u00c7oklu kontak sinyal aray\u00fczleri.<\/li>\n<li>Kablodan kabloya elektrik ba\u011flant\u0131lar\u0131.<\/li>\n<li>Panele monte edilmi\u015f ekipman ba\u011flant\u0131lar\u0131.<\/li>\n<\/ul>\n<h2>Sipari\u015f Bilgileri<\/h2>\n<p>Belirtin <strong>YOCL ELEKTR\u0130K<\/strong>, , <strong>tamamlanm\u0131\u015f LP-24 par\u00e7a numaras\u0131<\/strong>, kontak say\u0131s\u0131, konekt\u00f6r format\u0131, kontak cinsiyeti, gerekli ak\u0131m ve voltaj, iletken kesiti, kablo k\u0131l\u0131f\u0131 \u00e7ap\u0131 ve miktar\u0131. E\u015fle\u015fen bir \u00e7ift i\u00e7in her iki par\u00e7a numaras\u0131n\u0131 ve miktarlar\u0131n\u0131 listeleyin.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELEKTR\u0130KL\u0130 LP-24 H\u0131zl\u0131 Kilitli Su Ge\u00e7irmez Yuvarlak Konnekt\u00f6rler, ayr\u0131labilir g\u00fc\u00e7 ve sinyal aray\u00fczleri sa\u011flar <strong>2\u20136 kontakl\u0131<\/strong>.<\/p>\n<ul>\n<li>Dahil olmak \u00fczere, temasa ba\u011fl\u0131 ak\u0131m ve iletken yap\u0131land\u0131rmalar\u0131 <strong>2.5\u20134.0 mm\u00b2<\/strong> ve <strong>6.0\u20138.0 mm\u00b2<\/strong> iletken kesitleri.<\/li>\n<li><strong>D\u00fc\u011fmeli ge\u00e7meli kilit<\/strong> tek elle e\u015fle\u015ftirme ve ay\u0131rmay\u0131 destekler.<\/li>\n<li><strong>Vidal\u0131 kelep\u00e7e ba\u011flant\u0131s\u0131<\/strong> ve <strong>ba\u011fl\u0131 durumda IP68<\/strong>.<\/li>\n<li>Erkek ve di\u015fi elektrik kontakl\u0131 kablo fi\u015fleri, s\u0131ral\u0131 kenetleme soketleri, tek delikli panel soketleri ve d\u00f6rt delikli flan\u015f soketleri.<\/li>\n<li>Kablo \u00e7ap\u0131 se\u00e7enekleri: <strong>\u00d85\u20137 \/ \u00d87\u201310.5 \/ \u00d810.5\u201314 mm<\/strong>.<\/li>\n<\/ul>","protected":false},"featured_media":2802,"template":"","meta":[],"product_brand":[],"product_cat":[175],"product_tag":[],"class_list":["post-2807","product","type-product","status-publish","has-post-thumbnail","product_cat-lp-waterproof-connectors","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/2807","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/2802"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=2807"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=2807"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=2807"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=2807"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}