{"id":2814,"date":"2026-10-07T12:44:29","date_gmt":"2026-10-07T12:44:29","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2814"},"modified":"2026-10-07T12:53:43","modified_gmt":"2026-10-07T12:53:43","slug":"sp13-waterproof-circular-connectors","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/sp13-waterproof-circular-connectors\/","title":{"rendered":"SP13 IP68 Su Ge\u00e7irmez Yuvarlak Konnekt\u00f6rler"},"content":{"rendered":"<h2>Genel Bak\u0131\u015f<\/h2>\n<p>YOCL ELEKTR\u0130K SP13 su ge\u00e7irmez dairesel konekt\u00f6rler, ayr\u0131labilir kablo ve panel ba\u011flant\u0131lar\u0131 i\u00e7in di\u015fli kilitleme ve lehim sonland\u0131rma sa\u011flar. Aile, alt\u0131n kaplama bak\u0131r kontaklar, termoplastik g\u00f6vdeler ve PPS yal\u0131tkanlar kullan\u0131r ve IP68 koruma derecesine sahiptir.<\/p>\n<p>Seri, yedi kontak d\u00fczenini kapsar: 2, 3, 4, 5, 6, 7 ve 9 kontaklar. 2 ve 3 kontak konfig\u00fcrasyonlar\u0131 13 A ve 250 V AC olarak derecelendirilmi\u015ftir; daha y\u00fcksek kontak say\u0131lar\u0131 a\u015fa\u011f\u0131da g\u00f6sterildi\u011fi gibi kendi derecelendirmelerine sahiptir. \u0130ki kablo contas\u0131 boyutu 4\u20136.5 mm veya 5\u20138 mm kablo \u00e7aplar\u0131n\u0131 bar\u0131nd\u0131r\u0131r.<\/p>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li><strong>Di\u015fli kilitleme:<\/strong> bir vidal\u0131 kuplaj, e\u015fle\u015fen konekt\u00f6r yar\u0131mlar\u0131n\u0131 tutar.<\/li>\n<li><strong>Kontak se\u00e7enekleri:<\/strong> 2 \/ 3 \/ 4 \/ 5 \/ 6 \/ 7 \/ 9 kontaklar, kontak d\u00fczenine g\u00f6re se\u00e7ilen elektriksel de\u011ferlerle.<\/li>\n<li><strong>Alt\u0131n kaplama bak\u0131r kontaklar:<\/strong> bu sayfada listelenen konfig\u00fcrasyonlar i\u00e7in lehim ba\u011flant\u0131s\u0131.<\/li>\n<li><strong>Kablo ve panel formatlar\u0131:<\/strong> kablo fi\u015fi, hat i\u00e7i kablo soketi, arka somunlu panel soketi ve flan\u015f soketi.<\/li>\n<li><strong>Kablo contas\u0131 se\u00e7imi:<\/strong> 4\u20136.5 mm veya 5\u20138 mm kablo \u00e7ap\u0131.<\/li>\n<li><strong>S\u0131cakl\u0131k aral\u0131\u011f\u0131:<\/strong> \u221240\u00b0C ila +85\u00b0C, seri i\u00e7in listelenen 500 e\u015fle\u015fme d\u00f6ng\u00fcs\u00fc ile.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<h3>Genel \u00d6zellikler<\/h3>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>Teknik \u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marka<\/td>\n<td>YOCL ELEKTR\u0130K<\/td>\n<\/tr>\n<tr>\n<td>Seri<\/td>\n<td>SP13<\/td>\n<\/tr>\n<tr>\n<td>Kontak d\u00fczenlemeleri<\/td>\n<td>2 \/ 3 \/ 4 \/ 5 \/ 6 \/ 7 \/ 9 kontaklar<\/td>\n<\/tr>\n<tr>\n<td>Kavrama<\/td>\n<td>Di\u015fli kilitleme<\/td>\n<\/tr>\n<tr>\n<td>Sonland\u0131rma<\/td>\n<td>Lehim<\/td>\n<\/tr>\n<tr>\n<td>G\u00f6vde malzemesi<\/td>\n<td>Termoplastik PC \/ PA66<\/td>\n<\/tr>\n<tr>\n<td>G\u00f6vde malzemesi yang\u0131n derecesi<\/td>\n<td>V-0<\/td>\n<\/tr>\n<tr>\n<td>Yal\u0131tkan malzemesi<\/td>\n<td>Termoplastik PPS<\/td>\n<\/tr>\n<tr>\n<td>Kontak malzemesi<\/td>\n<td>Alt\u0131n kaplama bak\u0131r<\/td>\n<\/tr>\n<tr>\n<td>Koruma s\u0131n\u0131f\u0131<\/td>\n<td>IP68<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k aral\u0131\u011f\u0131<\/td>\n<td>\u221240\u00b0C ila +85\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>E\u015fle\u015fme d\u00f6ng\u00fcleri<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>Yal\u0131t\u0131m direnci<\/td>\n<td>2000 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Tip I kablo contas\u0131<\/td>\n<td>4\u20136.5 mm; Tip I model tan\u0131m\u0131nda i\u015faretlenmemi\u015ftir<\/td>\n<\/tr>\n<tr>\n<td>Tip II kablo contas\u0131<\/td>\n<td>5\u20138 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Kontak D\u00fczenine G\u00f6re Elektriksel De\u011ferler<\/h3>\n<table>\n<thead>\n<tr>\n<th>Kontaklar<\/th>\n<th>Anma ak\u0131m\u0131<\/th>\n<th>\u00c7al\u0131\u015fma gerilimi<\/th>\n<th>Kontak \u00e7ap\u0131 \u00d7 miktar<\/th>\n<th>Maksimum iletken kesiti<\/th>\n<th>Katalog AWG referans\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2<\/td>\n<td>13 A<\/td>\n<td>250 V AC<\/td>\n<td>\u00d81.6 mm \u00d7 2<\/td>\n<td>\u22642.0 mm\u00b2<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>13 A<\/td>\n<td>250 V AC<\/td>\n<td>\u00d81.6 mm \u00d7 3<\/td>\n<td>\u22642.0 mm\u00b2<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>5 A<\/td>\n<td>200 V AC<\/td>\n<td>\u00d81.0 mm \u00d7 4<\/td>\n<td>\u22640.75 mm\u00b2<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>5 A<\/td>\n<td>180 V AC<\/td>\n<td>\u00d81.0 mm \u00d7 5<\/td>\n<td>\u22640.75 mm\u00b2<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>5 A<\/td>\n<td>125 V AC<\/td>\n<td>\u00d81.0 mm \u00d7 6<\/td>\n<td>\u22640.75 mm\u00b2<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>5 A<\/td>\n<td>125 V AC<\/td>\n<td>\u00d81.0 mm \u00d7 7<\/td>\n<td>\u22640.75 mm\u00b2<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>3 A<\/td>\n<td>125 V AC<\/td>\n<td>\u00d80.7 mm \u00d7 9<\/td>\n<td>\u22640.5 mm\u00b2<\/td>\n<td>20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Choose the current, working voltage and conductor limit from the same row. The AWG values are the paired references supplied with the metric wire sizes; the conductor limit is expressed in mm\u00b2.<\/p>\n<h3>Dielectric Withstand and Contact Resistance<\/h3>\n<table>\n<thead>\n<tr>\n<th>Kontaklar<\/th>\n<th>Dielektrik dayan\u0131m gerilimi<\/th>\n<th>Kontak direnci<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2<\/td>\n<td>1500 V AC for 1 minute<\/td>\n<td>2.5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>1500 V AC for 1 minute<\/td>\n<td>2.5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>1500 V AC for 1 minute<\/td>\n<td>5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>1000 V AC for 1 minute<\/td>\n<td>5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>1000 V AC for 1 minute<\/td>\n<td>5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>1000 V AC for 1 minute<\/td>\n<td>5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>1000 V AC for 1 minute<\/td>\n<td>10 m\u03a9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The dielectric withstand value is a one-minute test voltage, separate from the working voltage.<\/p>\n<h2>Boyut<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/sp13-ip68-waterproof-circular-connectors-dimension.webp\" alt=\"SP13 IP68 Waterproof Circular Connectors dimension drawing\" \/><\/p>\n<h3>Konnekt\u00f6r G\u00f6vde Boyutlar\u0131<\/h3>\n<table>\n<thead>\n<tr>\n<th>Format<\/th>\n<th>Model ailesi<\/th>\n<th>Drawing dimensions<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Kablo fi\u015fi<\/td>\n<td>SP1310<\/td>\n<td>49.0 mm length; \u00d818.8 mm front diameter<\/td>\n<\/tr>\n<tr>\n<td>S\u0131ral\u0131 kablo soketi<\/td>\n<td>SP1311<\/td>\n<td>50.0 mm length; \u00d819.5 mm front diameter<\/td>\n<\/tr>\n<tr>\n<td>Arka somunlu panel soketi<\/td>\n<td>SP1312<\/td>\n<td>19.2 mm length; \u00d819.5 mm front diameter; M13 \u00d7 1 mounting thread<\/td>\n<\/tr>\n<tr>\n<td>Flange socket<\/td>\n<td>SP1313<\/td>\n<td>18.5 mm length; 19.5 mm front height; \u00d83.5 mm mounting holes; 22.1 mm body mounting-hole pitch<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Panel Mounting Dimensions<\/h3>\n<table>\n<thead>\n<tr>\n<th>Format<\/th>\n<th>Panel opening<\/th>\n<th>Montaj detaylar\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Arka somunlu panel soketi<\/td>\n<td>\u00d813.0 mm opening with 12.1 mm across flats<\/td>\n<td>Maximum panel thickness: 3.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Flange socket<\/td>\n<td>\u00d813.0 mm centre opening<\/td>\n<td>Two \u00d83.5 mm holes at 22.0 mm pitch<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Body dimensions and panel openings are listed separately. The flange body drawing gives 22.1 mm mounting-hole pitch, while the panel opening drawing gives 22.0 mm; use the panel opening dimensions when planning the panel.<\/p>\n<h2>Konnekt\u00f6r Formatlar\u0131 ve Model Tan\u0131mlamalar\u0131<\/h2>\n<table>\n<thead>\n<tr>\n<th>Format<\/th>\n<th>Pin-contact designation<\/th>\n<th>Socket-contact designation<\/th>\n<th>Matching format<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Kablo fi\u015fi<\/td>\n<td>SP1310\/P<\/td>\n<td>SP1310\/S<\/td>\n<td>Mates with SP1311, SP1312 or SP1313 of the corresponding contact arrangement<\/td>\n<\/tr>\n<tr>\n<td>S\u0131ral\u0131 kablo soketi<\/td>\n<td>SP1311\/P<\/td>\n<td>SP1311\/S<\/td>\n<td>Cable-to-cable connection with SP1310<\/td>\n<\/tr>\n<tr>\n<td>Arka somunlu panel soketi<\/td>\n<td>SP1312\/P<\/td>\n<td>SP1312\/S<\/td>\n<td>Panel connection with SP1310<\/td>\n<\/tr>\n<tr>\n<td>Flange socket<\/td>\n<td>SP1313\/P<\/td>\n<td>SP1313\/S<\/td>\n<td>Flange-mounted panel connection with SP1310<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>P<\/strong> identifies pin contacts and <strong>S<\/strong> identifies socket contacts. Both contact types are offered in each listed body format; choose complementary contacts and the same contact count for the mating pair. The designations above identify the connector format; specify the contact count separately in the enquiry.<\/p>\n<h2>Se\u00e7im K\u0131lavuzu<\/h2>\n<ol>\n<li>Select SP13 and the required contact count.<\/li>\n<li>Check the rated current, AC working voltage and conductor cross-section together in the electrical table.<\/li>\n<li>Choose a cable-to-cable or cable-to-panel connection and select the corresponding body format.<\/li>\n<li>Select Type I for 4\u20136.5 mm cable or Type II for 5\u20138 mm cable. Type I is unmarked in the catalogue designation; specify the seal size explicitly when ordering.<\/li>\n<li>Specify complementary P and S contacts and check the applicable body and panel dimensions.<\/li>\n<\/ol>\n<h2>Sipari\u015f Bilgileri<\/h2>\n<p>For a quotation, provide the SP13 model family, contact count, P or S contact type, cable outer diameter, mating connector format and required quantity. For panel sockets, include the panel thickness and mounting format.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELEKTR\u0130KL\u0130 SP13 su ge\u00e7irmez dairesel konekt\u00f6rler, kablo ve panel ba\u011flant\u0131lar\u0131 i\u00e7in lehim sonland\u0131rmal\u0131 di\u015fli kilitlemeyi birle\u015ftirir.<\/p>\n<ul>\n<li><strong>Kontaklar:<\/strong> 2 \/ 3 \/ 4 \/ 5 \/ 6 \/ 7 \/ 9.<\/li>\n<li><strong>Koruma:<\/strong> IP68.<\/li>\n<li><strong>Kablo \u00e7ap\u0131:<\/strong> 4\u20136.5 mm veya 5\u20138 mm.<\/li>\n<li><strong>Formatlar:<\/strong> kablo fi\u015fi, hat i\u00e7i kablo soketi, arka somunlu panel soketi ve flan\u015f soketi.<\/li>\n<li><strong>De\u011ferlendirmeler:<\/strong> se\u00e7im ak\u0131m\u0131 ve AC \u00e7al\u0131\u015fma gerilimi, teknik \u00f6zellik tablosundaki kontak say\u0131s\u0131na g\u00f6re.<\/li>\n<\/ul>","protected":false},"featured_media":2812,"template":"","meta":[],"product_brand":[],"product_cat":[176],"product_tag":[],"class_list":["post-2814","product","type-product","status-publish","has-post-thumbnail","product_cat-sp-waterproof-connectors","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/2814","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/2812"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=2814"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=2814"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=2814"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=2814"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}