{"id":2818,"date":"2026-10-07T12:47:57","date_gmt":"2026-10-07T12:47:57","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2818"},"modified":"2026-10-07T12:48:05","modified_gmt":"2026-10-07T12:48:05","slug":"sp17-waterproof-circular-connectors","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/sp17-waterproof-circular-connectors\/","title":{"rendered":"SP17 Su Ge\u00e7irmez Yuvarlak Konnekt\u00f6rler"},"content":{"rendered":"<h2>Genel Bak\u0131\u015f<\/h2>\n<p><strong>YOCL ELEKTR\u0130KL\u0130 SP17 su ge\u00e7irmez dairesel konekt\u00f6rler<\/strong> kablolar\u0131 e\u015fle\u015fen kablo veya panel prizlerine ba\u011flamak i\u00e7in di\u015fli bir kuplaj kullan\u0131r. Seri, d\u00fcz ve dik a\u00e7\u0131l\u0131 kablo fi\u015fleri, hat i\u00e7i bir kablo prizi ve d\u00f6rt panel priz format\u0131 i\u00e7erir.<\/p>\n<p>SP17 sunar <strong>2, 3, 4, 5, 7, 9 veya 10 kontaklar<\/strong>. Lehimli kontak konfig\u00fcrasyonlar\u0131, 2 ve 3 kontaklar i\u00e7in 10 A veya 4, 5, 7, 9 ve 10 kontaklar i\u00e7in 5 A olarak derecelendirilmi\u015ftir. \u00c7al\u0131\u015fma voltaj\u0131 da kontak say\u0131s\u0131na g\u00f6re de\u011fi\u015fir. A\u015fa\u011f\u0131daki tablolarda kontak d\u00fczenini, sonland\u0131rmay\u0131 ve e\u015fle\u015fme format\u0131n\u0131 birlikte se\u00e7in.<\/p>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li><strong>Di\u015fli kuplaj<\/strong> e\u015fle\u015fen fi\u015fi ve prizi tutar.<\/li>\n<li><strong>Yedi kontak d\u00fczeni<\/strong> 2, 3, 4, 5, 7, 9 ve 10 kontaklar\u0131 kapsar.<\/li>\n<li><strong>IP68 koruma s\u0131n\u0131f\u0131<\/strong> seri i\u00e7in kablo contalama bile\u015fenleri ve konekt\u00f6r kapaklar\u0131 g\u00f6sterilmi\u015ftir.<\/li>\n<li><strong>Alt\u0131n kaplama bak\u0131r kontaklar<\/strong> ve bir PPS yal\u0131tkan\u0131.<\/li>\n<li><strong>D\u00fcz ve dik a\u00e7\u0131l\u0131 fi\u015fler<\/strong> farkl\u0131 kablo \u00e7\u0131k\u0131\u015f y\u00f6nlerini destekler.<\/li>\n<li><strong>Kablo ve panel soket formatlar\u0131<\/strong> s\u0131ral\u0131 ba\u011flant\u0131lara veya ekipman montaj\u0131na izin verir.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<h3>Seri Verileri<\/h3>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>Teknik \u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marka<\/td>\n<td>YOCL ELEKTR\u0130K<\/td>\n<\/tr>\n<tr>\n<td>Seri<\/td>\n<td>SP17<\/td>\n<\/tr>\n<tr>\n<td>Kavrama<\/td>\n<td>Di\u015f kilitleme<\/td>\n<\/tr>\n<tr>\n<td>Kontak say\u0131s\u0131<\/td>\n<td>2, 3, 4, 5, 7, 9, 10<\/td>\n<\/tr>\n<tr>\n<td>Kontak malzemesi<\/td>\n<td>Alt\u0131n kaplama bak\u0131r<\/td>\n<\/tr>\n<tr>\n<td>G\u00f6vde malzemesi<\/td>\n<td>Termoplastik PC \/ PA66<\/td>\n<\/tr>\n<tr>\n<td>G\u00f6vde alev derecesi<\/td>\n<td>V-0<\/td>\n<\/tr>\n<tr>\n<td>Yal\u0131tkan<\/td>\n<td>Termoplastik PPS<\/td>\n<\/tr>\n<tr>\n<td>Koruma s\u0131n\u0131f\u0131<\/td>\n<td>IP68<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k aral\u0131\u011f\u0131<\/td>\n<td>\u221240 \u00b0C ila +85 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>E\u015fle\u015fme d\u00f6ng\u00fcleri<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>Yal\u0131t\u0131m direnci<\/td>\n<td>2000 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Sonland\u0131rma se\u00e7enekleri<\/td>\n<td>Se\u00e7ilen konekt\u00f6re ba\u011fl\u0131 olarak lehim ve s\u0131kma<\/td>\n<\/tr>\n<tr>\n<td>D\u00fcz kablo fi\u015fi \/ hat kablo soketi kablo OD<\/td>\n<td>6\u201310 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>IP68 tan\u0131m\u0131, sa\u011flanan verilerde bir dald\u0131rma derinli\u011fi veya s\u00fcresi belirtmez. Kablo contas\u0131n\u0131 se\u00e7ilen konekt\u00f6r ve kablo d\u0131\u015f \u00e7ap\u0131na g\u00f6re e\u015fle\u015ftirin.<\/p>\n<h3>Lehimli Kontak Derecelendirmeleri<\/h3>\n<p>A\u015fa\u011f\u0131daki elektriksel ve iletken verileri \u015funlar i\u00e7in ge\u00e7erlidir: <strong>lehim temas konfig\u00fcrasyonlar\u0131<\/strong>. S\u0131kma veya di\u011fer sonland\u0131rma konfig\u00fcrasyonlar\u0131 i\u00e7in ayr\u0131 bir derecelendirme tablosu de\u011fildir.<\/p>\n<table>\n<thead>\n<tr>\n<th>Kontaklar<\/th>\n<th>Anma ak\u0131m\u0131<\/th>\n<th>Kontak \u00e7ap\u0131 \u00d7 miktar<\/th>\n<th>\u00c7al\u0131\u015fma gerilimi<\/th>\n<th>AC dayan\u0131m gerilimi, 1 dakika<\/th>\n<th>Kontak direnci<\/th>\n<th>Maksimum iletken kesiti<\/th>\n<th>E\u015fle\u015ftirilmi\u015f AWG de\u011feri<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2<\/td>\n<td>10 A<\/td>\n<td>\u00d81.5 mm \u00d7 2<\/td>\n<td>500 V AC<\/td>\n<td>1500 V AC<\/td>\n<td>2.5 m\u03a9<\/td>\n<td>\u2264 2 mm\u00b2<\/td>\n<td>14 AWG<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>10 A<\/td>\n<td>\u00d81.5 mm \u00d7 3<\/td>\n<td>500 V AC<\/td>\n<td>1500 V AC<\/td>\n<td>2.5 m\u03a9<\/td>\n<td>\u2264 2 mm\u00b2<\/td>\n<td>14 AWG<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>5 A<\/td>\n<td>\u00d81.0 mm \u00d7 4<\/td>\n<td>500 V AC<\/td>\n<td>1500 V AC<\/td>\n<td>5 m\u03a9<\/td>\n<td>\u2264 0.75 mm\u00b2<\/td>\n<td>18 AWG<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>5 A<\/td>\n<td>\u00d81.0 mm \u00d7 5<\/td>\n<td>500 V AC<\/td>\n<td>1500 V AC<\/td>\n<td>5 m\u03a9<\/td>\n<td>\u2264 0.75 mm\u00b2<\/td>\n<td>18 AWG<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>5 A<\/td>\n<td>\u00d81.0 mm \u00d7 7<\/td>\n<td>400 V AC<\/td>\n<td>1200 V AC<\/td>\n<td>5 m\u03a9<\/td>\n<td>\u2264 0.75 mm\u00b2<\/td>\n<td>18 AWG<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>5 A<\/td>\n<td>\u00d81.0 mm \u00d7 9<\/td>\n<td>400 V AC<\/td>\n<td>1200 V AC<\/td>\n<td>5 m\u03a9<\/td>\n<td>\u2264 0.75 mm\u00b2<\/td>\n<td>18 AWG<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>5 A<\/td>\n<td>\u00d81.0 mm \u00d7 10<\/td>\n<td>400 V AC<\/td>\n<td>1200 V AC<\/td>\n<td>5 m\u03a9<\/td>\n<td>\u2264 0.75 mm\u00b2<\/td>\n<td>18 AWG<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u0130letken limitleri ve e\u015fle\u015ftirilmi\u015f AWG de\u011ferleri listelendi\u011fi gibi korunur. AWG de\u011ferleri, ba\u011f\u0131ms\u0131z olarak d\u00f6n\u00fc\u015ft\u00fcr\u00fclm\u00fc\u015f ek bir boyut aral\u0131\u011f\u0131 de\u011fildir. 1 dakikal\u0131k dayan\u0131m gerilimi, \u00e7al\u0131\u015fma geriliminden ayr\u0131 bir test parametresidir.<\/p>\n<h2>Boyut<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/sp17-waterproof-circular-connectors-dimension.webp\" alt=\"SP17 Waterproof Circular Connectors dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/sp17-waterproof-circular-connectors-dimension-02.webp\" alt=\"SP17 Waterproof Circular Connectors dimension drawing\"><\/p>\n<p>A\u015fa\u011f\u0131daki boyutlar <strong>milimetre<\/strong>. 'dir. G\u00f6vde boyutlar\u0131 ve panel a\u00e7\u0131kl\u0131klar\u0131 farkl\u0131 \u00f6zellikleri tan\u0131mlar ve se\u00e7ilen format i\u00e7in kontrol edilmelidir.<\/p>\n<h3>Konnekt\u00f6r G\u00f6vde Boyutlar\u0131<\/h3>\n<table>\n<thead>\n<tr>\n<th>Format<\/th>\n<th>Temel model<\/th>\n<th>Listelenen g\u00f6vde boyutlar\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>D\u00fcz kablo fi\u015fi<\/td>\n<td>SP1710<\/td>\n<td>Uzunluk 56.5; \u00f6n \u00e7ap \u00d824.6<\/td>\n<\/tr>\n<tr>\n<td>S\u0131ra i\u00e7i kablo soketi<\/td>\n<td>SP1711<\/td>\n<td>Uzunluk 56.5; \u00f6n \u00e7ap \u00d825<\/td>\n<\/tr>\n<tr>\n<td>Arka somunlu panel soketi<\/td>\n<td>SP1712<\/td>\n<td>Uzunluk 19.7; \u00f6n \u00e7\u0131k\u0131nt\u0131 10.7; \u00f6n \u00e7ap \u00d825; montaj di\u015flisi M17 \u00d7 1<\/td>\n<\/tr>\n<tr>\n<td>Vida soketi format\u0131<\/td>\n<td>SP1713<\/td>\n<td>Uzunluk 19.7; \u00f6n \u00e7\u0131k\u0131nt\u0131 10.7; \u00f6n \u00e7ap \u00d825; montaj di\u015flisi M17 \u00d7 1<\/td>\n<\/tr>\n<tr>\n<td>Kare panel soketi<\/td>\n<td>SP1714<\/td>\n<td>Uzunluk 22.0; \u00f6n \u00e7\u0131k\u0131nt\u0131 11; flan\u015f kal\u0131nl\u0131\u011f\u0131 4.0; flan\u015f dikey boyutu 26.0; arka di\u015f M16 \u00d7 1<\/td>\n<\/tr>\n<tr>\n<td>Flan\u015f panel soketi<\/td>\n<td>SP1715<\/td>\n<td>Flan\u015f geni\u015fli\u011fi 34.0; y\u00fckseklik 24.8; g\u00f6vde pim \u00e7ap\u0131 \u00d816.0<\/td>\n<\/tr>\n<tr>\n<td>Dik a\u00e7\u0131l\u0131 kablo fi\u015fi<\/td>\n<td>SP1716<\/td>\n<td>Toplam yatay boyut 57; dikey boyut 51; \u00f6n dikey boyut 29.3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Panel A\u00e7\u0131kl\u0131k Verileri<\/h3>\n<table>\n<thead>\n<tr>\n<th>Panel format\u0131<\/th>\n<th>Listelenen a\u00e7\u0131kl\u0131k verileri<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SP1712 \/ SP1713<\/td>\n<td>Anahtarl\u0131 a\u00e7\u0131kl\u0131k \u00d817 ve 15.6 d\u00fcz kenarlar aras\u0131; maksimum panel kal\u0131nl\u0131\u011f\u0131 3<\/td>\n<\/tr>\n<tr>\n<td>SP1715<\/td>\n<td>Merkezi a\u00e7\u0131kl\u0131k \u00d816.8; sabitleme delikleri \u00d83.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Bir panel \u00fczerinde i\u015flem yapmadan \u00f6nce, sabitleme deli\u011fi konumlar\u0131n\u0131 ve konekt\u00f6r \u00e7evresinde gereken bo\u015flu\u011fu i\u00e7eren tam montaj \u00e7izimini kontrol edin.<\/p>\n<h2>Konekt\u00f6r Formatlar\u0131 ve E\u015fle\u015ftirme Se\u00e7imi<\/h2>\n<p>Her bir temel model \u015furada g\u00f6sterilmi\u015ftir: <strong>\/P<\/strong> ve <strong>\/S<\/strong> kontak versiyonlar\u0131. <strong>P erkek pin kontaklar\u0131; S di\u015fi soket kontaklar\u0131 belirtir.<\/strong> Kontak cinsiyeti, konekt\u00f6r g\u00f6vdesinin kablo fi\u015fi mi yoksa soket mi oldu\u011fundan ayr\u0131d\u0131r.<\/p>\n<table>\n<thead>\n<tr>\n<th>Temel model<\/th>\n<th>Format<\/th>\n<th>E\u015fle\u015fen taban modelleri<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SP1710<\/td>\n<td>D\u00fcz kablo fi\u015fi<\/td>\n<td>SP1711, SP1712, SP1713, SP1714, SP1715<\/td>\n<\/tr>\n<tr>\n<td>SP1711<\/td>\n<td>S\u0131ra i\u00e7i kablo soketi<\/td>\n<td>SP1710, SP1716<\/td>\n<\/tr>\n<tr>\n<td>SP1712<\/td>\n<td>Arka somunlu panel soketi<\/td>\n<td>SP1710, SP1716<\/td>\n<\/tr>\n<tr>\n<td>SP1713<\/td>\n<td>Vida soketi format\u0131<\/td>\n<td>SP1710, SP1716<\/td>\n<\/tr>\n<tr>\n<td>SP1714<\/td>\n<td>Kare panel soketi<\/td>\n<td>SP1710, SP1716<\/td>\n<\/tr>\n<tr>\n<td>SP1715<\/td>\n<td>Flan\u015f panel soketi<\/td>\n<td>SP1710, SP1716<\/td>\n<\/tr>\n<tr>\n<td>SP1716<\/td>\n<td>Dik a\u00e7\u0131l\u0131 kablo fi\u015fi<\/td>\n<td>SP1711, SP1712, SP1713, SP1714, SP1715<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Ayn\u0131 kontak say\u0131s\u0131na ve d\u00fczenine sahip uyumlu bir pin\/soket \u00e7ifti se\u00e7in. Tablo, eksiksiz sipari\u015f edilebilir bir par\u00e7a numaras\u0131 yerine e\u015fle\u015fen g\u00f6vde ailelerini tan\u0131mlar.<\/p>\n<h2>Model Tan\u0131mlama ve Se\u00e7im K\u0131lavuzu<\/h2>\n<p>\u00d6rne\u011fin, <strong>SP1710\/P<\/strong> pin kontakl\u0131 d\u00fcz kablo fi\u015fini tan\u0131mlarken, <strong>SP1711\/S<\/strong> soket kontakl\u0131 s\u0131ral\u0131 kablo soketini tan\u0131mlar. Kontak say\u0131s\u0131 ve sonland\u0131rman\u0131n hala belirtilmesi gerekir.<\/p>\n<p>SP1710 kod a\u00e7\u0131klamas\u0131 tan\u0131mlar <strong>lehim sonland\u0131rmay\u0131 1 kodu olarak, normalde i\u015faretsiz<\/strong>, ve <strong>crimp termination as code 3<\/strong>. State the required termination in an enquiry; do not select a crimp configuration solely from the solder rating table.<\/p>\n<ol>\n<li>Select the contact count and check its solder working voltage and rated current where applicable.<\/li>\n<li>Choose a straight or right-angle cable plug and a matching cable or panel receptacle.<\/li>\n<li>Specify P pin contacts or S socket contacts for each mating half.<\/li>\n<li>State the conductor size and termination method.<\/li>\n<li>State the cable outer diameter for each cable connector and the panel mounting format for each panel receptacle.<\/li>\n<\/ol>\n<h2>Sipari\u015f Bilgileri<\/h2>\n<p>For an SP17 enquiry, provide the <strong>base model, contact count, P\/S contact version, termination, conductor size, cable outer diameter and quantity<\/strong>. For panel receptacles, include the mounting format and available panel thickness. For right-angle plugs, include the cable exit direction and cable diameter so the corresponding seal configuration can be selected.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELEKTRIK SP17 su ge\u00e7irmez dairesel konekt\u00f6rler, yedi kontak d\u00fczeniyle di\u015fli kablo ve panel ba\u011flant\u0131lar\u0131 sa\u011flar.<\/p>\n<ul>\n<li>2, 3, 4, 5, 7, 9 veya 10 kontaklar<\/li>\n<li>IP68 koruma s\u0131n\u0131f\u0131; \u221240 \u00b0C ila +85 \u00b0C s\u0131cakl\u0131k aral\u0131\u011f\u0131<\/li>\n<li>Lehim dereceleri: 10 A 2\/3 kontaklar i\u00e7in, 5 A 4\/5\/7\/9\/10 kontaklar i\u00e7in<\/li>\n<li>\u00c7al\u0131\u015fma voltaj\u0131: 500 V AC 2\u20135 kontaklar i\u00e7in; 400 V AC 7\/9\/10 kontaklar i\u00e7in, lehim konfig\u00fcrasyonlar\u0131 i\u00e7in<\/li>\n<li>D\u00fcz ve dik a\u00e7\u0131l\u0131 fi\u015fler, hat i\u00e7i ve panel priz formatlar\u0131nda<\/li>\n<\/ul>","protected":false},"featured_media":2815,"template":"","meta":[],"product_brand":[],"product_cat":[176],"product_tag":[],"class_list":["post-2818","product","type-product","status-publish","has-post-thumbnail","product_cat-sp-waterproof-connectors","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/2818","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/2815"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=2818"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=2818"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=2818"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=2818"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}