{"id":2826,"date":"2026-10-07T12:51:44","date_gmt":"2026-10-07T12:51:44","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2826"},"modified":"2026-10-07T12:51:54","modified_gmt":"2026-10-07T12:51:54","slug":"sp29-waterproof-circular-connectors","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/sp29-waterproof-circular-connectors\/","title":{"rendered":"SP29 Su Ge\u00e7irmez Yuvarlak Konnekt\u00f6rler"},"content":{"rendered":"<h2>Genel Bak\u0131\u015f<\/h2>\n<p>YOCL ELEKTR\u0130K SP29 Su Ge\u00e7irmez Yuvarlak Konnekt\u00f6rler, ayr\u0131labilir kablo-kablo ve kablo-panel elektrik ba\u011flant\u0131lar\u0131 sa\u011flar <strong>2, 3, 4, 5, 7, 9 veya 12 kontaklar<\/strong>. Di\u015fli bir kuplaj, e\u015fle\u015fen g\u00f6vdeleri sabitlerken, pin ve soket kontak se\u00e7enekleri gerekli elektrik d\u00fczeninin se\u00e7ilmesine olanak tan\u0131r.<\/p>\n<p>Seri, d\u00fcz ve a\u00e7\u0131l\u0131 kablo fi\u015fleri, hat i\u00e7i kablo soketleri, arka somunlu panel soketleri ve flan\u015f montajl\u0131 soketler i\u00e7erir. D\u00fcz kablo fi\u015fi ve hat i\u00e7i kablo soketi \u015funlar i\u00e7in listelenmi\u015ftir: <strong>13\u201316 mm<\/strong> kablo d\u0131\u015f \u00e7aplar\u0131. Katalog listeler <strong>IP68 koruma<\/strong>, kontak konfig\u00fcrasyonu taraf\u0131ndan se\u00e7ilen elektriksel ve kablo sonland\u0131rma \u00f6zellikleriyle.<\/p>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li><strong>Di\u015f kilitleme:<\/strong> Bir vida kuplaj\u0131, e\u015fle\u015fen konekt\u00f6r g\u00f6vdelerini birle\u015ftirir.<\/li>\n<li><strong>Yedi kontak say\u0131s\u0131 se\u00e7ene\u011fi:<\/strong> 2, 3, 4, 5, 7, 9 veya 12 kontak se\u00e7in.<\/li>\n<li><strong>Kablo ve panel g\u00f6vde stilleri:<\/strong> D\u00fcz fi\u015fler, hat i\u00e7i ba\u011flant\u0131lar, a\u00e7\u0131l\u0131 fi\u015fler ve ekipman soketleri listelenmi\u015ftir.<\/li>\n<li><strong>Pin ve soket kontaklar\u0131:<\/strong> P ve S tan\u0131mlamalar\u0131 elektriksel kontak tipini ifade eder.<\/li>\n<li><strong>Alt\u0131n kaplama bak\u0131r kontaklar:<\/strong> Katalogda alt\u0131n kaplamal\u0131 bak\u0131r kontaklar belirtilmi\u015ftir.<\/li>\n<li><strong>Se\u00e7ilebilir sonland\u0131rma:<\/strong> Lehim, vidal\u0131 terminal ve s\u0131kma versiyonlar\u0131 listelenmi\u015ftir, yap\u0131land\u0131rmaya \u00f6zel limitler mevcuttur.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>Teknik \u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marka<\/td>\n<td>YOCL ELEKTR\u0130K<\/td>\n<\/tr>\n<tr>\n<td>Seri<\/td>\n<td>SP29<\/td>\n<\/tr>\n<tr>\n<td>Konnekt\u00f6r tipi<\/td>\n<td>Su ge\u00e7irmez dairesel konnekt\u00f6r<\/td>\n<\/tr>\n<tr>\n<td>Kontak say\u0131s\u0131<\/td>\n<td>2 \/ 3 \/ 4 \/ 5 \/ 7 \/ 9 \/ 12<\/td>\n<\/tr>\n<tr>\n<td>Kavrama<\/td>\n<td>Di\u015f kilitleme<\/td>\n<\/tr>\n<tr>\n<td>Kontak tipleri<\/td>\n<td>P: pin; S: soket<\/td>\n<\/tr>\n<tr>\n<td>G\u00f6vde malzemeleri<\/td>\n<td>Termoplastik PC \/ PA66<\/td>\n<\/tr>\n<tr>\n<td>G\u00f6vde malzemesi yang\u0131n derecesi<\/td>\n<td>V-0<\/td>\n<\/tr>\n<tr>\n<td>Yal\u0131tkan<\/td>\n<td>Termoplastik PPS<\/td>\n<\/tr>\n<tr>\n<td>Kontaklar<\/td>\n<td>Alt\u0131n kaplama bak\u0131r<\/td>\n<\/tr>\n<tr>\n<td>Koruma s\u0131n\u0131f\u0131<\/td>\n<td>IP68, katalog derecelendirmesi<\/td>\n<\/tr>\n<tr>\n<td>Katalog e\u015fle\u015fme d\u00f6ng\u00fcs\u00fc rakam\u0131<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k aral\u0131\u011f\u0131<\/td>\n<td>\u221240 \u00b0C ila +85 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Yal\u0131t\u0131m direnci<\/td>\n<td>2000 M\u03a9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Elektriksel Kontak Verileri<\/h3>\n<p>A\u015fa\u011f\u0131daki de\u011ferler katalogun lehim kontak parametreleri tablosundan al\u0131nm\u0131\u015ft\u0131r. Bunlar, k\u0131v\u0131rma kontaklar\u0131 i\u00e7in ayr\u0131 bir spesifikasyon de\u011fildir.<\/p>\n<table>\n<thead>\n<tr>\n<th>Kontaklar<\/th>\n<th>Anma ak\u0131m\u0131<\/th>\n<th>Kontak \u00e7ap\u0131 \u00d7 adet<\/th>\n<th>\u00c7al\u0131\u015fma gerilimi, AC<\/th>\n<th>Dayan\u0131m gerilimi, AC, 1 dakika<\/th>\n<th>Kontak direnci<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2<\/td>\n<td>\u2014<\/td>\n<td>\u00d83 mm \u00d7 2<\/td>\n<td>500 V<\/td>\n<td>1500 V<\/td>\n<td>1 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>\u2014<\/td>\n<td>\u00d83 mm \u00d7 3<\/td>\n<td>500 V<\/td>\n<td>1500 V<\/td>\n<td>1 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>\u2014<\/td>\n<td>\u00d83 mm \u00d7 4<\/td>\n<td>500 V<\/td>\n<td>1500 V<\/td>\n<td>1 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>\u2014<\/td>\n<td>\u00d83 mm \u00d7 5<\/td>\n<td>500 V<\/td>\n<td>1500 V<\/td>\n<td>1 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>15 A<\/td>\n<td>\u00d82 mm \u00d7 7<\/td>\n<td>500 V<\/td>\n<td>1500 V<\/td>\n<td>2.5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>5 A<\/td>\n<td>\u00d81 mm \u00d7 9<\/td>\n<td>400 V<\/td>\n<td>1500 V<\/td>\n<td>5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>5 A<\/td>\n<td>\u00d81 mm \u00d7 12<\/td>\n<td>400 V<\/td>\n<td>1200 V<\/td>\n<td>5 m\u03a9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u0130ki ila be\u015f kontakl\u0131 konfig\u00fcrasyonlar i\u00e7in, sipari\u015f verirken se\u00e7ilen sonland\u0131rma ve par\u00e7a numaras\u0131 i\u00e7in ak\u0131m de\u011ferini al\u0131n. \u00c7al\u0131\u015fma gerilimi ve bir dakikal\u0131k dayan\u0131m de\u011feri farkl\u0131 parametreleri a\u00e7\u0131klar.<\/p>\n<h3>Sonland\u0131rmaya G\u00f6re \u0130letken Limitleri<\/h3>\n<table>\n<thead>\n<tr>\n<th>Kontaklar<\/th>\n<th>Lehimli iletken limiti<\/th>\n<th>Katalog AWG giri\u015fi<\/th>\n<th>Vidal\u0131 terminal iletken limiti<\/th>\n<th>Katalog AWG giri\u015fi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2 \/ 3 \/ 4 \/ 5<\/td>\n<td>\u22644 mm\u00b2<\/td>\n<td>12 AWG<\/td>\n<td>\u22641.5 mm\u00b2<\/td>\n<td>15 AWG<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>\u22642 mm\u00b2<\/td>\n<td>14 AWG<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>9 \/ 12<\/td>\n<td>\u22640.75 mm\u00b2<\/td>\n<td>18 AWG<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Metrik limitler ve AWG giri\u015fleri katalog \u00e7iftleri olarak \u00e7o\u011falt\u0131lm\u0131\u015ft\u0131r. Bir tire i\u015fareti, bu tablodaki sonland\u0131rma i\u00e7in iletken limiti sa\u011flanmad\u0131\u011f\u0131 anlam\u0131na gelir. Tel boyutunu kontak yuvas\u0131 ve sonland\u0131rma ile birlikte se\u00e7in. S\u0131kmaya \u00f6zel iletken limitleri burada belirtilmemi\u015ftir.<\/p>\n<h3>Kablo K\u0131l\u0131f\u0131 Se\u00e7imi<\/h3>\n<table>\n<thead>\n<tr>\n<th>Uygulanabilir g\u00f6vde stilleri<\/th>\n<th>Listelenen kablo d\u0131\u015f \u00e7ap\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SP2910 d\u00fcz kablo fi\u015fleri ve SP2911 hat i\u00e7i kablo soketleri<\/td>\n<td>13\u201316 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A\u00e7\u0131sal SP2916 kablo \u00e7ap\u0131 burada belirtilmemi\u015ftir. Bu g\u00f6vde stili istendi\u011finde ger\u00e7ek kablo \u00e7ap\u0131n\u0131 ekleyin.<\/p>\n<h2>Boyut<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/sp29-waterproof-circular-connectors-dimension.webp\" alt=\"SP29 Waterproof Circular Connectors dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/sp29-waterproof-circular-connectors-dimension-02.webp\" alt=\"SP29 Waterproof Circular Connectors dimension drawing\"><\/p>\n<h3>Konnekt\u00f6r G\u00f6vde Boyutlar\u0131<\/h3>\n<table>\n<thead>\n<tr>\n<th>Temel model<\/th>\n<th>Listelenen g\u00f6vde boyutlar\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SP2910 d\u00fcz kablo fi\u015fi<\/td>\n<td>70.5 mm toplam uzunluk; 38.8 mm \u00f6n geni\u015flik<\/td>\n<\/tr>\n<tr>\n<td>SP2911 hat i\u00e7i kablo soketi<\/td>\n<td>70.5 mm toplam uzunluk; \u00d838.8 mm \u00f6n \u00e7ap<\/td>\n<\/tr>\n<tr>\n<td>SP2912 \/ SP2913 panel soketleri<\/td>\n<td>21.5 mm toplam uzunluk; M29 \u00d7 1.25 montaj vidas\u0131; panel kal\u0131nl\u0131\u011f\u0131 2 mm maks.<\/td>\n<\/tr>\n<tr>\n<td>SP2914 kare flan\u015f soketi<\/td>\n<td>39 \u00d7 39 mm flan\u015f; 22 mm toplam eksenel uzunluk; 30 mm montaj deli\u011fi aral\u0131\u011f\u0131; \u00d83.5 mm g\u00f6vde montaj delikleri<\/td>\n<\/tr>\n<tr>\n<td>SP2915 iki delikli flan\u015f soketi<\/td>\n<td>55 mm g\u00f6vde geni\u015fli\u011fi \u00d7 39 mm y\u00fckseklik; 45 mm delik aral\u0131\u011f\u0131; iki adet \u00d84.5 mm g\u00f6vde montaj deli\u011fi; 21.5 mm toplam uzunluk<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Panel A\u00e7\u0131kl\u0131k Boyutlar\u0131<\/h3>\n<table>\n<thead>\n<tr>\n<th>Panel soketi<\/th>\n<th>Listelenen panel a\u00e7\u0131kl\u0131\u011f\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SP2912 \/ SP2913<\/td>\n<td>\u00d829.2 mm a\u00e7\u0131kl\u0131k, 26.8 mm d\u00fczden-d\u00fczeye y\u00fckseklik<\/td>\n<\/tr>\n<tr>\n<td>SP2914<\/td>\n<td>28.5 mm merkezi a\u00e7\u0131kl\u0131k; g\u00f6sterilen 30 mm hatvesinde \u00d83.5 mm montaj delikleri<\/td>\n<\/tr>\n<tr>\n<td>SP2915<\/td>\n<td>\u00d828 mm merkezi a\u00e7\u0131kl\u0131k; 45 mm merkezlerinde iki adet \u00d85 mm montaj deli\u011fi<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Konnekt\u00f6r g\u00f6vdesi delikleri ve panel montaj delikleri ayr\u0131 boyutlara sahiptir. A\u00e7\u0131kl\u0131k \u015feklini ve delik konumlar\u0131n\u0131 kontrol etmek i\u00e7in se\u00e7ilen soketin tam kurulum \u00e7izimini kullan\u0131n.<\/p>\n<h2>Konnekt\u00f6r Formatlar\u0131 ve E\u015fle\u015fen Aileler<\/h2>\n<table>\n<thead>\n<tr>\n<th>Taban g\u00f6vde modeli<\/th>\n<th>Format<\/th>\n<th>Listelenen e\u015fle\u015fen aile<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SP2910<\/td>\n<td>D\u00fcz kablo fi\u015fi<\/td>\n<td>SP2911 \/ SP2912 \/ SP2913 \/ SP2914 \/ SP2915<\/td>\n<\/tr>\n<tr>\n<td>SP2911<\/td>\n<td>S\u0131ral\u0131 kablo soketi<\/td>\n<td>SP2910 \/ SP2916<\/td>\n<\/tr>\n<tr>\n<td>SP2912<\/td>\n<td>Arka somunlu panel soketi<\/td>\n<td>SP2910 \/ SP2916<\/td>\n<\/tr>\n<tr>\n<td>SP2913<\/td>\n<td>Panel socket, style 13<\/td>\n<td>SP2910 \/ SP2916<\/td>\n<\/tr>\n<tr>\n<td>SP2914<\/td>\n<td>Kare flan\u015fl\u0131 panel soketi<\/td>\n<td>SP2910 \/ SP2916<\/td>\n<\/tr>\n<tr>\n<td>SP2915<\/td>\n<td>Two-hole flange panel socket<\/td>\n<td>SP2910 \/ SP2916<\/td>\n<\/tr>\n<tr>\n<td>SP2916<\/td>\n<td>Angled cable plug<\/td>\n<td>SP2911 \/ SP2912 \/ SP2913 \/ SP2914 \/ SP2915<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Each body family is shown with <strong>\/P pin<\/strong> ve <strong>\/S socket<\/strong> contact options. Match the contact count and opposite electrical contact types as well as the body families when specifying a mating pair.<\/p>\n<h2>Sipari\u015f Bilgileri<\/h2>\n<p>Use the base body model and contact designation, such as <strong>SP2910\/P<\/strong> for a straight cable plug with pin contacts or <strong>SP2914\/S<\/strong> for a square-flange body with socket contacts. These are catalogue base designations; contact count, cable seal range and termination must also be specified.<\/p>\n<p>The catalogue&#8217;s termination legend uses <strong>1 for soldering (unmarked)<\/strong>, <strong>2 for screw termination<\/strong> ve <strong>3 for crimping<\/strong>. The presence of a termination in the legend does not establish that every body and contact-count combination is available in that form. Obtain the complete part number for the requested configuration.<\/p>\n<h2>Se\u00e7im K\u0131lavuzu<\/h2>\n<ol>\n<li>Select the body style and mating body family.<\/li>\n<li>Specify pin or socket contacts and the required contact count on both sides.<\/li>\n<li>Select the termination and conductor size using the applicable limits.<\/li>\n<li>Match the cable seal to the cable jacket diameter; for panel versions, use the format-specific opening dimensions.<\/li>\n<li>Specify the required current, AC working voltage, quantity and mating-part requirements. Obtain model-specific data for a crimp version or a two- to five-contact current rating.<\/li>\n<\/ol>\n<h2>Uygulamalar<\/h2>\n<ul>\n<li>Detachable equipment wiring.<\/li>\n<li>Inline cable connections.<\/li>\n<li>Panel-mounted electrical interfaces.<\/li>\n<li>Multi-contact power and signal connections.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>YOCL ELEKTR\u0130KL\u0130 SP29 Su Ge\u00e7irmez Yuvarlak Konnekt\u00f6rler, di\u015fli kilitleme ve se\u00e7ilebilir kontak konfig\u00fcrasyonlar\u0131 ile kablo ve ekipman aray\u00fczleri sa\u011flar.<\/p>\n<ul>\n<li><strong>2 \/ 3 \/ 4 \/ 5 \/ 7 \/ 9 \/ 12 kontaklar<\/strong>; pin ve soket se\u00e7enekleri.<\/li>\n<li><strong>IP68 katalog de\u011feri<\/strong> ve <strong>\u221240 \u00b0C ila +85 \u00b0C<\/strong> s\u0131cakl\u0131k aral\u0131\u011f\u0131.<\/li>\n<li>Alt\u0131n kaplama bak\u0131r kontaklar, PC \/ PA66 g\u00f6vdeler ve PPS yal\u0131tkanlar.<\/li>\n<li>D\u00fcz ve a\u00e7\u0131l\u0131 kablo fi\u015fleri, hat i\u00e7i soketler ve panel soket formatlar\u0131.<\/li>\n<li>D\u00fcz kablo fi\u015fi ve hat i\u00e7i kablo soketi: <strong>13\u201316 mm<\/strong> kablo d\u0131\u015f \u00e7ap\u0131.<\/li>\n<li>Lehim, vidal\u0131 terminal ve s\u0131kma se\u00e7enekleri yap\u0131land\u0131rmaya ba\u011fl\u0131d\u0131r.<\/li>\n<\/ul>","protected":false},"featured_media":2823,"template":"","meta":[],"product_brand":[],"product_cat":[176],"product_tag":[],"class_list":["post-2826","product","type-product","status-publish","has-post-thumbnail","product_cat-sp-waterproof-connectors","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/2826","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/2823"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=2826"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=2826"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=2826"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=2826"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}