{"id":2856,"date":"2026-10-07T13:58:16","date_gmt":"2026-10-07T13:58:16","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2856"},"modified":"2026-10-07T13:58:26","modified_gmt":"2026-10-07T13:58:26","slug":"ip44-industrial-cable-couplers","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/ip44-industrial-cable-couplers\/","title":{"rendered":"IP44 End\u00fcstriyel Kablo Kupl\u00f6rleri"},"content":{"rendered":"<h2>Genel Bak\u0131\u015f<\/h2>\n<p>YOCL ELEKTR\u0130K IP44 end\u00fcstriyel kablo kuplajlar\u0131, end\u00fcstriyel kablo ba\u011flant\u0131lar\u0131 i\u00e7in di\u015fi kablo konekt\u00f6rleridir. Bu aile, a\u015fa\u011f\u0131da listelenen ger\u00e7ek 16 A ve 32 A modellerini, 2P+E, 3P+E ve 3P+N+E kontak d\u00fczenlemeleriyle bir araya getirir. Her modelin kendi voltaj\u0131, toprak kontak saat konumu ve g\u00f6vde tasar\u0131m\u0131 vard\u0131r.<\/p>\n<p>Konekt\u00f6r ucunda di\u015fi kontaklar ve koruyucu bir \u00f6n kapak bulunur; arka giri\u015f besleme kablosunu kabul eder. H-tasar\u0131m, K-tasar\u0131m, beyaz arka g\u00f6vde ve \u00f6zel saat konumu versiyonlar\u0131, g\u00f6vde foto\u011fraf\u0131n\u0131n ve boyut verilerinin do\u011fru konekt\u00f6rle e\u015fle\u015ftirilebilmesi i\u00e7in ayr\u0131 model gruplar\u0131 olarak kal\u0131r.<\/p>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li>Listelenen modeller i\u00e7in IP44 koruma derecesi.<\/li>\n<li>Kablo konekt\u00f6r\u00fc ucu i\u00e7in di\u015fi kontaklar ve koruyucu kapak.<\/li>\n<li>Anma ak\u0131m\u0131 se\u00e7enekleri: 16 A ve 32 A; ger\u00e7ek kombinasyonlar model tablolar\u0131yla tan\u0131mlan\u0131r.<\/li>\n<li>2P+E, 3P+E ve 3P+N+E versiyonlar\u0131 ayr\u0131 ayr\u0131 tan\u0131mlan\u0131r.<\/li>\n<li>Toprak kontak d\u00fczenleri: Adland\u0131r\u0131lan modele g\u00f6re 4h, 6h ve se\u00e7ilmi\u015f 9h.<\/li>\n<li>Ayr\u0131 muhafaza gruplar\u0131, her modelin iletken kapasitesini ve boyut verilerini korur.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>Teknik \u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marka<\/td>\n<td>YOCL ELEKTR\u0130K<\/td>\n<\/tr>\n<tr>\n<td>\u00dcr\u00fcn tipi<\/td>\n<td>Di\u015fi kablo konekt\u00f6rleri<\/td>\n<\/tr>\n<tr>\n<td>Montaj<\/td>\n<td>Kabloya monte<\/td>\n<\/tr>\n<tr>\n<td>Koruma s\u0131n\u0131f\u0131<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td>Anma ak\u0131mlar\u0131<\/td>\n<td>16 A ve 32 A<\/td>\n<\/tr>\n<tr>\n<td>Kontak d\u00fczenlemeleri<\/td>\n<td>2P+E (3 kontak); 3P+E (4 kontak); 3P+N+E (5 kontak)<\/td>\n<\/tr>\n<tr>\n<td>Toprak-temas konumlar\u0131<\/td>\n<td>4h, 6h ve se\u00e7ilmi\u015f 9h<\/td>\n<\/tr>\n<tr>\n<td>Voltaj yap\u0131land\u0131rmalar\u0131<\/td>\n<td>Bireysel model sat\u0131rlar\u0131na bak\u0131n\u0131z; e\u015fle\u015ftirilmi\u015f be\u015f kontak de\u011ferleri listelendi\u011fi gibi korunur.<\/td>\n<\/tr>\n<tr>\n<td>\u0130letken kapasiteleri<\/td>\n<td>Model-specific values in mm\u00b2; see the selection tables.<\/td>\n<\/tr>\n<tr>\n<td>Housing designs<\/td>\n<td>See the separate model groups below.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>H g\u00f6vde tasar\u0131m\u0131 \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Printed reference<\/th>\n<th>Ak\u0131m (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213H-4<\/td>\n<td>511<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>Sar\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-223H-4<\/td>\n<td>523<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>Sar\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-213H<\/td>\n<td>511<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-223H<\/td>\n<td>523<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-214H<\/td>\n<td>514<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-224H<\/td>\n<td>526<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-215H<\/td>\n<td>NM5<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-225H<\/td>\n<td>NM6<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>K g\u00f6vde tasar\u0131m\u0131 \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Ak\u0131m (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213K-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>Sar\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-223K-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>Sar\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-213K<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-223K<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-214K<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-224K<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-215K<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-225K<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Beyaz arka g\u00f6vde tasar\u0131mlar\u0131 \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Ak\u0131m (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>Sar\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-223-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>Sar\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-213L<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-223L<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-213<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-223<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-214<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-224<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-215<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-225<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u00d6zel 9h kontak d\u00fczenleri \u2014 16 \/ 32 A<\/h2>\n<p>These 9h models use the particular voltage and contact layouts shown below. Their conductor capacities and dimensions are not extended from the ordinary models.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Ak\u0131m (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213L-9<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>380\u2013415<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-223L-9<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>380\u2013415<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-214L-9<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-224L-9<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Boyut<\/h2>\n<p>The symbols below reproduce each housing group\u2019s dimensional table in millimetres. Letter meanings differ between drawings; a repeated symbol does not define one common dimension across all groups. Match the full model code and housing group before using a drawing.<\/p>\n<h3>H g\u00f6vde tasar\u0131m\u0131 \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213H-4<\/td>\n<td>a = 155; b = 51.3; c = 57<\/td>\n<\/tr>\n<tr>\n<td>NM-223H-4<\/td>\n<td>a = 200; b = 64.2; c = 71.6<\/td>\n<\/tr>\n<tr>\n<td>NM-213H<\/td>\n<td>a = 155; b = 51.3; c = 57<\/td>\n<\/tr>\n<tr>\n<td>NM-223H<\/td>\n<td>a = 200; b = 64.2; c = 71.6<\/td>\n<\/tr>\n<tr>\n<td>NM-214H<\/td>\n<td>a = 156.5; b = 51.3; c = 61.2<\/td>\n<\/tr>\n<tr>\n<td>NM-224H<\/td>\n<td>a = 200; b = 64.2; c = 71.6<\/td>\n<\/tr>\n<tr>\n<td>NM-215H<\/td>\n<td>a = 161.7; b = 50.2; c = 69<\/td>\n<\/tr>\n<tr>\n<td>NM-225H<\/td>\n<td>a = 200; b = 70.8; c = 79.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>K g\u00f6vde tasar\u0131m\u0131 \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213K-4<\/td>\n<td>a = 134; b = 73; c = 51<\/td>\n<\/tr>\n<tr>\n<td>NM-223K-4<\/td>\n<td>a = 167; b = 90; c = 66<\/td>\n<\/tr>\n<tr>\n<td>NM-213K<\/td>\n<td>a = 134; b = 73; c = 51<\/td>\n<\/tr>\n<tr>\n<td>NM-223K<\/td>\n<td>a = 167; b = 90; c = 66<\/td>\n<\/tr>\n<tr>\n<td>NM-214K<\/td>\n<td>a = 143; b = 80; c = 57<\/td>\n<\/tr>\n<tr>\n<td>NM-224K<\/td>\n<td>a = 167; b = 90; c = 66<\/td>\n<\/tr>\n<tr>\n<td>NM-215K<\/td>\n<td>a = 150; b = 82; c = 64<\/td>\n<\/tr>\n<tr>\n<td>NM-225K<\/td>\n<td>a = 167; b = 97; c = 72<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Beyaz arka g\u00f6vde tasar\u0131mlar\u0131 \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213-4<\/td>\n<td>a = 131; b = 69; c = 50.5; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-223-4<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-213L<\/td>\n<td>a = 131; b = 69; c = 50.5; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-223L<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-213<\/td>\n<td>a = 131; b = 69; c = 50.5; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-223<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-214<\/td>\n<td>a = 131; b = 79; c = 56; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-224<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-215<\/td>\n<td>a = 141; b = 93; c = 64; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-225<\/td>\n<td>a = 154; b = 101; c = 71; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-02.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-03.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-04.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-05.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<h2>Se\u00e7im K\u0131lavuzu<\/h2>\n<p>Choose a female cable coupler when the mating connection is made at the end of a cable. A wall-mounted socket or an appliance inlet belongs to a different mounting and contact family.<\/p>\n<p>Select the current rating, contact arrangement, rated voltage, earth-contact clock position and IP rating together from one actual model row. Body color alone is insufficient: the special clock-position groups include different voltage\/contact combinations from the ordinary groups.<\/p>\n<p>Keep the complete suffix when selecting the housing version. Models that share an electrical rating may have different lengths, cable-entry dimensions or body shapes. Conductor capacity is a cross-sectional range in mm\u00b2 and must not be confused with a cable-entry dimension in mm.<\/p>\n<p>For five-contact models, the table preserves the paired 220\u2013380 \/ 240\u2013415 V notation. It does not create an additional arbitrary voltage combination. A dash in the capacity column means that the particular row supplies no confirmed value.<\/p>\n<h2>Sipari\u015f Bilgileri<\/h2>\n<p>When enquiring about YOCL ELECTRIC IP44 industrial cable couplers, provide the full model code, quantity, current rating, contact arrangement, rated voltage, clock position and the required housing design. Include the conductor cross-section and cable outside diameter so that the cable entry and terminal range can be checked for that specific model.<\/p>\n<p>Printed secondary references identify the catalogue entries where shown; they do not create extra model options or replace the full NM model code.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELEKTR\u0130K IP44 kablo ucu ba\u011flant\u0131lar\u0131 i\u00e7in end\u00fcstriyel kablo kuplajlar\u0131, farkl\u0131 g\u00f6vde tasar\u0131mlar\u0131 ve eksiksiz NM model se\u00e7im tablolar\u0131 ile.<\/p>\n<ul>\n<li>Anma ak\u0131mlar\u0131: 16 A ve 32 A.<\/li>\n<li>Kontak d\u00fczenleri: 2P+E, 3P+E ve 3P+N+E.<\/li>\n<li>Modele ba\u011fl\u0131 olarak 4h, 6h ve se\u00e7ilmi\u015f 9h toprak kontak d\u00fczenleri.<\/li>\n<li>\u00d6n kapakl\u0131 di\u015fi kablo konekt\u00f6r\u00fc.<\/li>\n<li>Tam model kodu ile voltaj\u0131, iletken kapasitesini ve boyutlar\u0131 se\u00e7in.<\/li>\n<\/ul>","protected":false},"featured_media":2850,"template":"","meta":[],"product_brand":[],"product_cat":[55],"product_tag":[],"class_list":["post-2856","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-couplers","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/2856","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/2850"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=2856"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=2856"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=2856"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=2856"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}