{"id":2891,"date":"2026-10-07T14:27:32","date_gmt":"2026-10-07T14:27:32","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2891"},"modified":"2026-10-07T14:27:41","modified_gmt":"2026-10-07T14:27:41","slug":"ip67-industrial-plugs","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/ip67-industrial-plugs\/","title":{"rendered":"IP67 End\u00fcstriyel Fi\u015fler"},"content":{"rendered":"<h2>Genel Bak\u0131\u015f<\/h2>\n<p>YOCL ELECTRIC IP67 end\u00fcstriyel fi\u015fler, end\u00fcstriyel kablo ba\u011flant\u0131lar\u0131 i\u00e7in erkek kablo fi\u015fleridir. Bu aile, a\u015fa\u011f\u0131da listelenen ger\u00e7ek 16 A, 32 A, 63 A ve 125 A modellerini, 2P+E, 3P+E ve 3P+N+E kontak d\u00fczenleriyle bir araya getirir. Her modelin kendi voltaj\u0131, toprak kontak saati konumu ve g\u00f6vde tasar\u0131m\u0131 vard\u0131r.<\/p>\n<p>\u00d6n k\u0131s\u0131mda \u00e7\u0131k\u0131nt\u0131l\u0131 erkek kontaklar ve kilitleme halkas\u0131 e\u015fle\u015fme tasar\u0131m\u0131 bulunurken, arka k\u0131s\u0131mdan kablo giri\u015fi yap\u0131l\u0131r. 16 \/ 32 A ve 63 \/ 125 A g\u00f6vde tasar\u0131mlar\u0131 model tablolar\u0131nda ayr\u0131lm\u0131\u015ft\u0131r. \u00d6zel 3h versiyonlar\u0131, kendi kontak konumlar\u0131yla adland\u0131r\u0131lm\u0131\u015f modeller olarak dahil edilmi\u015ftir.<\/p>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li>Listelenen modeller i\u00e7in IP67 koruma derecesi.<\/li>\n<li>Panel montaj\u0131 yerine kablo montajl\u0131 erkek kontaklar.<\/li>\n<li>Nominal ak\u0131m se\u00e7enekleri: 16 A, 32 A, 63 A ve 125 A; ger\u00e7ek kombinasyonlar model tablolar\u0131yla tan\u0131mlan\u0131r.<\/li>\n<li>2P+E, 3P+E ve 3P+N+E versiyonlar\u0131 ayr\u0131 ayr\u0131 tan\u0131mlan\u0131r.<\/li>\n<li>Toprak-temas d\u00fczenleri: 4h, 6h ve se\u00e7ilmi\u015f 3h, belirtilen modele g\u00f6re.<\/li>\n<li>Ayr\u0131 muhafaza gruplar\u0131, her modelin iletken kapasitesini ve boyut verilerini korur.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>Teknik \u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marka<\/td>\n<td>YOCL ELEKTR\u0130K<\/td>\n<\/tr>\n<tr>\n<td>\u00dcr\u00fcn tipi<\/td>\n<td>Erkek kablo fi\u015fleri<\/td>\n<\/tr>\n<tr>\n<td>Montaj<\/td>\n<td>Kabloya monte<\/td>\n<\/tr>\n<tr>\n<td>Koruma s\u0131n\u0131f\u0131<\/td>\n<td>IP67<\/td>\n<\/tr>\n<tr>\n<td>Anma ak\u0131mlar\u0131<\/td>\n<td>16 A, 32 A, 63 A ve 125 A<\/td>\n<\/tr>\n<tr>\n<td>Kontak d\u00fczenlemeleri<\/td>\n<td>2P+E (3 kontak); 3P+E (4 kontak); 3P+N+E (5 kontak)<\/td>\n<\/tr>\n<tr>\n<td>Toprak-temas konumlar\u0131<\/td>\n<td>4s, 6s ve se\u00e7ilmi\u015f 3s<\/td>\n<\/tr>\n<tr>\n<td>Voltaj yap\u0131land\u0131rmalar\u0131<\/td>\n<td>Bireysel model sat\u0131rlar\u0131na bak\u0131n\u0131z; e\u015fle\u015ftirilmi\u015f be\u015f kontak de\u011ferleri listelendi\u011fi gibi korunur.<\/td>\n<\/tr>\n<tr>\n<td>\u0130letken kapasiteleri<\/td>\n<td>Model-specific values in mm\u00b2; see the selection tables.<\/td>\n<\/tr>\n<tr>\n<td>Housing designs<\/td>\n<td>See the separate model groups below.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Kilitleme halkas\u0131 g\u00f6vde tasar\u0131m\u0131 \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Printed reference<\/th>\n<th>Ak\u0131m (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-0131-4<\/td>\n<td>278<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>Sar\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-0231-4<\/td>\n<td>290<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>Sar\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-0131<\/td>\n<td>278<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-0231<\/td>\n<td>290<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-0141<\/td>\n<td>282<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-0241<\/td>\n<td>294<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-0151<\/td>\n<td>288<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-0251<\/td>\n<td>291<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Beyaz arka g\u00f6vde kilitleme tasar\u0131m\u0131 \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Ak\u0131m (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-0132<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-0232<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-0142<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-0242<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-0152<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-0252<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Gri arka g\u00f6vde tasar\u0131m\u0131 \u2014 63 \/ 125 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Ak\u0131m (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-0332<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>6\u201316<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-0432<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>16\u201350<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-0342<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>6\u201316<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-0442<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>16\u201350<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-0352<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>6\u201316<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-0452<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>16\u201350<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Beyaz arka g\u00f6vde tasar\u0131m\u0131 \u2014 63 \/ 125 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Ak\u0131m (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-033<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>6\u201316<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-043<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>16\u201350<\/td>\n<td>Mavi<\/td>\n<\/tr>\n<tr>\n<td>NM-034<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>6\u201316<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-044<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>16\u201350<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-035<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>6\u201316<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-045<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>16\u201350<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u00d6zel 3h kontak d\u00fczeni \u2014 16 \/ 32 A<\/h2>\n<p>These 3h models are distinct from the ordinary 6h models; the model suffix must be included when ordering.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Ak\u0131m (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-0142-3<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>3h<\/td>\n<td>\u2014<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<tr>\n<td>NM-0242-3<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>3h<\/td>\n<td>\u2014<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Boyut<\/h2>\n<p>The symbols below reproduce each housing group\u2019s dimensional table in millimetres. Letter meanings differ between drawings; a repeated symbol does not define one common dimension across all groups. Match the full model code and housing group before using a drawing.<\/p>\n<h3>Kilitleme halkas\u0131 g\u00f6vde tasar\u0131m\u0131 \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-0131-4<\/td>\n<td>a = 138; b = 115; d = 70.2<\/td>\n<\/tr>\n<tr>\n<td>NM-0231-4<\/td>\n<td>a = 170; b = 141; d = 93.3<\/td>\n<\/tr>\n<tr>\n<td>NM-0131<\/td>\n<td>a = 138; b = 115; d = 70.2<\/td>\n<\/tr>\n<tr>\n<td>NM-0231<\/td>\n<td>a = 170; b = 141; d = 93.3<\/td>\n<\/tr>\n<tr>\n<td>NM-0141<\/td>\n<td>a = 144; b = 120.5; d = 78<\/td>\n<\/tr>\n<tr>\n<td>NM-0241<\/td>\n<td>a = 170; b = 141; d = 93.3<\/td>\n<\/tr>\n<tr>\n<td>NM-0151<\/td>\n<td>a = 144; b = 120.5; d = 87<\/td>\n<\/tr>\n<tr>\n<td>NM-0251<\/td>\n<td>a = 177; b = 148; d = 101<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Beyaz arka g\u00f6vde kilitleme tasar\u0131m\u0131 \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-0132<\/td>\n<td>a = 127; b = 47; c = 6\u201315; SW = 44<\/td>\n<\/tr>\n<tr>\n<td>NM-0232<\/td>\n<td>a = 158; b = 63; c = 10\u201320; SW = 54<\/td>\n<\/tr>\n<tr>\n<td>NM-0142<\/td>\n<td>a = 133; b = 53; c = 6\u201315; SW = 44<\/td>\n<\/tr>\n<tr>\n<td>NM-0242<\/td>\n<td>a = 158; b = 63; c = 10\u201320; SW = 54<\/td>\n<\/tr>\n<tr>\n<td>NM-0152<\/td>\n<td>a = 140; b = 61; c = 6\u201315; SW = 44<\/td>\n<\/tr>\n<tr>\n<td>NM-0252<\/td>\n<td>a = 165; b = 69; c = 10\u201320; SW = 54<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Gri arka g\u00f6vde tasar\u0131m\u0131 \u2014 63 \/ 125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-0332<\/td>\n<td>a = 250; b = 115; c = 23<\/td>\n<\/tr>\n<tr>\n<td>NM-0432<\/td>\n<td>a = 275; b = 128; c = 31<\/td>\n<\/tr>\n<tr>\n<td>NM-0342<\/td>\n<td>a = 250; b = 115; c = 23<\/td>\n<\/tr>\n<tr>\n<td>NM-0442<\/td>\n<td>a = 275; b = 128; c = 31<\/td>\n<\/tr>\n<tr>\n<td>NM-0352<\/td>\n<td>a = 250; b = 115; c = 23<\/td>\n<\/tr>\n<tr>\n<td>NM-0452<\/td>\n<td>a = 275; b = 128; c = 31<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Beyaz arka g\u00f6vde tasar\u0131m\u0131 \u2014 63 \/ 125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-033<\/td>\n<td>a = 231.5; b = 110; c = 16\u201338; \u03c6 = 110<\/td>\n<\/tr>\n<tr>\n<td>NM-043<\/td>\n<td>a = 295; b = 123; c = 30\u201364; \u03c6 = 123<\/td>\n<\/tr>\n<tr>\n<td>NM-034<\/td>\n<td>a = 231.5; b = 110; c = 16\u201338; \u03c6 = 110<\/td>\n<\/tr>\n<tr>\n<td>NM-044<\/td>\n<td>a = 295; b = 123; c = 30\u201364; \u03c6 = 123<\/td>\n<\/tr>\n<tr>\n<td>NM-035<\/td>\n<td>a = 231.5; b = 110; c = 16\u201338; \u03c6 = 110<\/td>\n<\/tr>\n<tr>\n<td>NM-045<\/td>\n<td>a = 295; b = 123; c = 30\u201364; \u03c6 = 123<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-industrial-plugs-dimension.webp\" alt=\"IP67 Industrial Plugs dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-industrial-plugs-dimension-02.webp\" alt=\"IP67 Industrial Plugs dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-industrial-plugs-dimension-03.webp\" alt=\"IP67 Industrial Plugs dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-industrial-plugs-dimension-04.webp\" alt=\"IP67 Industrial Plugs dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-industrial-plugs-dimension-05.webp\" alt=\"IP67 Industrial Plugs dimension drawing\"><\/p>\n<h2>Se\u00e7im K\u0131lavuzu<\/h2>\n<p>Choose a male cable plug for a cable-end connection. A panel-mounted or surface-mounted appliance inlet uses a fixed mounting arrangement and belongs to a different product family.<\/p>\n<p>Select the current rating, contact arrangement, rated voltage, earth-contact clock position and IP rating together from one actual model row. Body color alone is insufficient: the special clock-position groups include different voltage\/contact combinations from the ordinary groups.<\/p>\n<p>Keep the complete suffix when selecting the housing version. Models that share an electrical rating may have different lengths, cable-entry dimensions or body shapes. Conductor capacity is a cross-sectional range in mm\u00b2 and must not be confused with a cable-entry dimension in mm.<\/p>\n<p>For five-contact models, the table preserves the paired 220\u2013380 \/ 240\u2013415 V notation. It does not create an additional arbitrary voltage combination. A dash in the capacity column means that the particular row supplies no confirmed value.<\/p>\n<h2>Sipari\u015f Bilgileri<\/h2>\n<p>When enquiring about YOCL ELECTRIC IP67 industrial plugs, provide the full model code, quantity, current rating, contact arrangement, rated voltage, clock position and the required housing design. Include the conductor cross-section and cable outside diameter so that the cable entry and terminal range can be checked for that specific model.<\/p>\n<p>Printed secondary references identify the catalogue entries where shown; they do not create extra model options or replace the full NM model code.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELEKTR\u0130KL\u0130 IP67 kablo ucu ba\u011flant\u0131lar\u0131 i\u00e7in end\u00fcstriyel fi\u015fler, farkl\u0131 g\u00f6vde tasar\u0131mlar\u0131 ve eksiksiz NM model se\u00e7im tablolar\u0131.<\/p>\n<ul>\n<li>Anma ak\u0131mlar\u0131: 16 A, 32 A, 63 A ve 125 A.<\/li>\n<li>Kontak d\u00fczenleri: 2P+E, 3P+E ve 3P+N+E.<\/li>\n<li>Modele ba\u011fl\u0131 olarak 4h, 6h ve se\u00e7ilmi\u015f 3h toprak kontak d\u00fczenleri.<\/li>\n<li>Arka kablo giri\u015fli erkek kablo fi\u015fi.<\/li>\n<li>Tam model kodu ile voltaj\u0131, iletken kapasitesini ve boyutlar\u0131 se\u00e7in.<\/li>\n<\/ul>","protected":false},"featured_media":2885,"template":"","meta":[],"product_brand":[],"product_cat":[53],"product_tag":[],"class_list":["post-2891","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-plugs","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/2891","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/2885"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=2891"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=2891"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=2891"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=2891"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}