{"id":2897,"date":"2026-10-07T14:39:08","date_gmt":"2026-10-07T14:39:08","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2897"},"modified":"2026-10-07T14:39:17","modified_gmt":"2026-10-07T14:39:17","slug":"ip67-straight-panel-sockets","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/ip67-straight-panel-sockets\/","title":{"rendered":"IP67 D\u00fcz Panel Montaj Soketleri"},"content":{"rendered":"<h2>Genel Bak\u0131\u015f<\/h2>\n<p>YOCL ELECTRIC IP67 d\u00fcz panel montajl\u0131 end\u00fcstriyel prizler, uyumlu end\u00fcstriyel fi\u015fler i\u00e7in sabit bir di\u015fi ba\u011flant\u0131 noktas\u0131 sa\u011flar. Seri, 16 \/ 32 \/ 63 \/ 125 A de\u011ferlerini ve 2P+E, 3P+E, 3P+N+E kontak d\u00fczenlemelerini i\u00e7erir. Her model, belirli bir ak\u0131m de\u011feri, voltaj, toprak konta\u011f\u0131 konumu ve muhafaza tasar\u0131m\u0131n\u0131 birle\u015ftirir.<\/p>\n<p>Se\u00e7im tablolar\u0131, mevcut muhafaza s\u00fcr\u00fcmlerini tek bir \u00fcr\u00fcn ailesinde bir arada tutar. Elektriksel yap\u0131land\u0131rmay\u0131 ve ilgili kurulum boyutlar\u0131n\u0131 belirtmek i\u00e7in tam NM model kodunu kullan\u0131n.<\/p>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li>D\u00fcz priz ekseni ve panel kurulumu i\u00e7in montaj flan\u015f\u0131.<\/li>\n<li>Listelenen modeller i\u00e7in IP67 koruma derecesi.<\/li>\n<li>Priz y\u00fcz\u00fcnde mente\u015feli kapak.<\/li>\n<li>Se\u00e7im tablolar\u0131nda belirtilen tam modele g\u00f6re mavi ve k\u0131rm\u0131z\u0131 konfig\u00fcrasyonlar.<\/li>\n<li>Elektrik ba\u011flant\u0131s\u0131n\u0131 ve kurulum alan\u0131n\u0131 se\u00e7mek i\u00e7in modele \u00f6zel iletken aral\u0131klar\u0131 ve montaj boyutlar\u0131.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>Teknik \u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marka<\/td>\n<td>YOCL ELEKTR\u0130K<\/td>\n<\/tr>\n<tr>\n<td>\u00dcr\u00fcn tipi<\/td>\n<td>IP67 D\u00fcz Panel Montaj Soketleri<\/td>\n<\/tr>\n<tr>\n<td>Kontak cinsiyeti<\/td>\n<td>Di\u015fi priz<\/td>\n<\/tr>\n<tr>\n<td>Montaj<\/td>\n<td>D\u00fcz panel montajl\u0131<\/td>\n<\/tr>\n<tr>\n<td>Koruma s\u0131n\u0131f\u0131<\/td>\n<td>IP67<\/td>\n<\/tr>\n<tr>\n<td>Nominal ak\u0131m se\u00e7enekleri<\/td>\n<td>16 \/ 32 \/ 63 \/ 125 A<\/td>\n<\/tr>\n<tr>\n<td>Kontak d\u00fczenlemeleri<\/td>\n<td>2P+E \/ 3P+E \/ 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>Voltaj yap\u0131land\u0131rmalar\u0131<\/td>\n<td>220\u2013240 V; 380\u2013415 V; 220\u2013380 \/ 240\u2013415 V<\/td>\n<\/tr>\n<tr>\n<td>Toprak kontak konumlar\u0131<\/td>\n<td>6h<\/td>\n<\/tr>\n<tr>\n<td>\u0130letken kesiti<\/td>\n<td>Model \u00f6zelinde de\u011ferler se\u00e7im tablolar\u0131nda<\/td>\n<\/tr>\n<tr>\n<td>G\u00f6vde versiyonlar\u0131<\/td>\n<td>Tasar\u0131m 1 muhafaza, 16\/32 A; Tasar\u0131m 2 muhafaza, 63\/125 A; Tasar\u0131m 2 muhafaza, 16\/32 A; Standart muhafaza, 63\/125 A<\/td>\n<\/tr>\n<tr>\n<td>Model se\u00e7enekleri<\/td>\n<td>24<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Model Se\u00e7im Tablolar\u0131<\/h2>\n<p>Voltaj ve ak\u0131m de\u011ferleri tam model sat\u0131r\u0131na aittir. Bir tire, sa\u011flanan verilerde modele \u00f6zel bir de\u011ferin mevcut olmad\u0131\u011f\u0131n\u0131 g\u00f6sterir.<\/p>\n<h3>Tasar\u0131m 1 g\u00f6vde, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Anma ak\u0131m\u0131 (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Toprak konumu<\/th>\n<th>Renk<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-3131<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-3231<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-3141<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-3241<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-3151<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-3251<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Anma ak\u0131m\u0131 (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Toprak konumu<\/th>\n<th>Renk<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-3332<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-3432<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-3342<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-3442<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-3352<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-3452<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Anma ak\u0131m\u0131 (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Toprak konumu<\/th>\n<th>Renk<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-4132<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-4232<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-4142<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-4242<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-4152<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-4252<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Standard housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Anma ak\u0131m\u0131 (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Toprak konumu<\/th>\n<th>Renk<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-333<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-343<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-334<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-344<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-335<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-345<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Boyut<\/h2>\n<p>Dimension letters apply to the individual housing drawing. The same letter can identify a different feature on another housing version. Select the mounting dimensions from the exact model row.<\/p>\n<h3>Tasar\u0131m 1 g\u00f6vde, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-3131<\/td>\n<td>76<\/td>\n<td>76<\/td>\n<td>83<\/td>\n<\/tr>\n<tr>\n<td>NM-3231<\/td>\n<td>76<\/td>\n<td>85<\/td>\n<td>99<\/td>\n<\/tr>\n<tr>\n<td>NM-3141<\/td>\n<td>76<\/td>\n<td>76<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-3241<\/td>\n<td>76<\/td>\n<td>85<\/td>\n<td>99<\/td>\n<\/tr>\n<tr>\n<td>NM-3151<\/td>\n<td>76<\/td>\n<td>76<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>NM-3251<\/td>\n<td>76<\/td>\n<td>85<\/td>\n<td>105<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Fixing centres 60 \u00d7 60; circular opening \u00d865; fixing holes \u00d85.<\/p>\n<h3>Design 2 housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a, b (mm)<\/th>\n<th>c, d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<th>g (mm)<\/th>\n<th>h (mm)<\/th>\n<th>i (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-3332<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>48<\/td>\n<td>83<\/td>\n<td>116<\/td>\n<td>\u2014<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3432<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>45<\/td>\n<td>104<\/td>\n<td>127<\/td>\n<td>100<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3342<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>48<\/td>\n<td>83<\/td>\n<td>116<\/td>\n<td>\u2014<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3442<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>45<\/td>\n<td>104<\/td>\n<td>127<\/td>\n<td>100<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3352<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>48<\/td>\n<td>83<\/td>\n<td>116<\/td>\n<td>\u2014<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3452<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>45<\/td>\n<td>104<\/td>\n<td>127<\/td>\n<td>100<\/td>\n<td>7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-4132<\/td>\n<td>56<\/td>\n<td>83<\/td>\n<\/tr>\n<tr>\n<td>NM-4232<\/td>\n<td>65<\/td>\n<td>97<\/td>\n<\/tr>\n<tr>\n<td>NM-4142<\/td>\n<td>56<\/td>\n<td>89<\/td>\n<\/tr>\n<tr>\n<td>NM-4242<\/td>\n<td>65<\/td>\n<td>97<\/td>\n<\/tr>\n<tr>\n<td>NM-4152<\/td>\n<td>56<\/td>\n<td>92<\/td>\n<\/tr>\n<tr>\n<td>NM-4252<\/td>\n<td>67<\/td>\n<td>105<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Flange 76 \u00d7 76; fixing centres 60 \u00d7 60; circular opening \u00d865; fixing holes \u00d85.<\/p>\n<h3>Standard housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<th>g (mm)<\/th>\n<th>h (mm)<\/th>\n<th>i (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-333<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>57<\/td>\n<td>86<\/td>\n<td>115<\/td>\n<td>109<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td>NM-343<\/td>\n<td>120<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>65<\/td>\n<td>96<\/td>\n<td>130<\/td>\n<td>124<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-334<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>57<\/td>\n<td>86<\/td>\n<td>115<\/td>\n<td>109<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td>NM-344<\/td>\n<td>120<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>65<\/td>\n<td>96<\/td>\n<td>130<\/td>\n<td>124<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-335<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>57<\/td>\n<td>86<\/td>\n<td>115<\/td>\n<td>109<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td>NM-345<\/td>\n<td>120<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>65<\/td>\n<td>96<\/td>\n<td>130<\/td>\n<td>124<\/td>\n<td>88<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-straight-panel-mounted-sockets-dimension.webp\" alt=\"IP67 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-straight-panel-mounted-sockets-dimension-02.webp\" alt=\"IP67 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-straight-panel-mounted-sockets-dimension-03.webp\" alt=\"IP67 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-straight-panel-mounted-sockets-dimension-04.webp\" alt=\"IP67 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<h2>Se\u00e7im K\u0131lavuzu<\/h2>\n<ol>\n<li>Choose the rated current and contact arrangement required for the connection.<\/li>\n<li>Match the voltage configuration and earth contact position to the mating plug. Colour alone is insufficient for model selection.<\/li>\n<li>Select the housing version and use its own mounting and conductor-range values.<\/li>\n<li>Include the complete model code and quantity in the enquiry.<\/li>\n<\/ol>\n<h2>Sipari\u015f Bilgileri<\/h2>\n<p>For a quotation, provide the complete NM model code, required quantity and mounting version. If identifying a replacement, include a photograph of the existing contact face and mounting layout.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP67 d\u00fcz panel montajl\u0131 end\u00fcstriyel prizler sabit end\u00fcstriyel g\u00fc\u00e7 ba\u011flant\u0131lar\u0131 i\u00e7in.<\/p>\n<ul>\n<li>Ak\u0131m de\u011ferleri: 16 \/ 32 \/ 63 \/ 125 A.<\/li>\n<li>Kontak d\u00fczenleri: 2P+E \/ 3P+E \/ 3P+N+E.<\/li>\n<li>Mente\u015feli kapakl\u0131 ve panel montaj flan\u015fl\u0131 di\u015fi priz.<\/li>\n<li>Tam model se\u00e7im tablolar\u0131 voltaj, toprak konta\u011f\u0131 konumu, iletken aral\u0131klar\u0131 ve muhafazaya \u00f6zg\u00fc boyutlar\u0131 i\u00e7erir.<\/li>\n<li>Tam NM model kodu ile se\u00e7in ve sorgulay\u0131n.<\/li>\n<\/ul>","protected":false},"featured_media":2892,"template":"","meta":[],"product_brand":[],"product_cat":[54],"product_tag":[],"class_list":["post-2897","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-sockets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/2897","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/2892"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=2897"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=2897"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=2897"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=2897"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}