{"id":2904,"date":"2026-10-07T14:42:24","date_gmt":"2026-10-07T14:42:24","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2904"},"modified":"2026-10-07T14:42:33","modified_gmt":"2026-10-07T14:42:33","slug":"ip67-surface-mounted-industrial-sockets","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/ip67-surface-mounted-industrial-sockets\/","title":{"rendered":"IP67 Y\u00fczeye Montajl\u0131 End\u00fcstriyel Soketler"},"content":{"rendered":"<h2>Genel Bak\u0131\u015f<\/h2>\n<p>YOCL ELEKTR\u0130K IP67 y\u00fczeye monte end\u00fcstriyel prizler, uyumlu end\u00fcstriyel fi\u015fler i\u00e7in sabit bir di\u015fi ba\u011flant\u0131 noktas\u0131 sa\u011flar. Seri, 16 \/ 32 \/ 63 \/ 125 A de\u011ferlerini ve 2P+E, 3P+E, 3P+N+E kontak d\u00fczenlemelerini i\u00e7erir. Her model, belirli bir ak\u0131m de\u011feri, voltaj\u0131, toprak kontak konumunu ve muhafaza tasar\u0131m\u0131n\u0131 birle\u015ftirir.<\/p>\n<p>Se\u00e7im tablolar\u0131, mevcut muhafaza s\u00fcr\u00fcmlerini tek bir \u00fcr\u00fcn ailesinde bir arada tutar. Elektriksel yap\u0131land\u0131rmay\u0131 ve ilgili kurulum boyutlar\u0131n\u0131 belirtmek i\u00e7in tam NM model kodunu kullan\u0131n.<\/p>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li>Sabit priz kurulumu i\u00e7in arka muhafaza ve y\u00fczey sabitleme yap\u0131s\u0131.<\/li>\n<li>Listelenen modeller i\u00e7in IP67 koruma derecesi.<\/li>\n<li>Priz y\u00fcz\u00fcnde mente\u015feli kapak.<\/li>\n<li>Se\u00e7im tablolar\u0131nda tam modelle listelenen mavi, k\u0131rm\u0131z\u0131 ve sar\u0131 yap\u0131land\u0131rmalar.<\/li>\n<li>Elektrik ba\u011flant\u0131s\u0131n\u0131 ve kurulum alan\u0131n\u0131 se\u00e7mek i\u00e7in modele \u00f6zel iletken aral\u0131klar\u0131 ve montaj boyutlar\u0131.<\/li>\n<li>Alternatif toprak kontak konumlar\u0131 ayr\u0131 olarak listelenmi\u015ftir; toprak konumunu ama\u00e7lanan fi\u015f yap\u0131land\u0131rmas\u0131na uydurun.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>Teknik \u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marka<\/td>\n<td>YOCL ELEKTR\u0130K<\/td>\n<\/tr>\n<tr>\n<td>\u00dcr\u00fcn tipi<\/td>\n<td>IP67 Y\u00fczeye Montajl\u0131 End\u00fcstriyel Soketler<\/td>\n<\/tr>\n<tr>\n<td>Kontak cinsiyeti<\/td>\n<td>Di\u015fi priz<\/td>\n<\/tr>\n<tr>\n<td>Montaj<\/td>\n<td>Y\u00fczeye monte<\/td>\n<\/tr>\n<tr>\n<td>Koruma s\u0131n\u0131f\u0131<\/td>\n<td>IP67<\/td>\n<\/tr>\n<tr>\n<td>Nominal ak\u0131m se\u00e7enekleri<\/td>\n<td>16 \/ 32 \/ 63 \/ 125 A<\/td>\n<\/tr>\n<tr>\n<td>Kontak d\u00fczenlemeleri<\/td>\n<td>2P+E \/ 3P+E \/ 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>Voltaj yap\u0131land\u0131rmalar\u0131<\/td>\n<td>110\u2013130 V; 220\u2013240 V; 380\u2013415 V; 220\u2013380 \/ 240\u2013415 V<\/td>\n<\/tr>\n<tr>\n<td>Toprak kontak konumlar\u0131<\/td>\n<td>4s \/ 6s \/ 3s<\/td>\n<\/tr>\n<tr>\n<td>\u0130letken kesiti<\/td>\n<td>Model \u00f6zelinde de\u011ferler se\u00e7im tablolar\u0131nda<\/td>\n<\/tr>\n<tr>\n<td>G\u00f6vde versiyonlar\u0131<\/td>\n<td>Tasar\u0131m 1 g\u00f6vde, 16\/32 A; Tasar\u0131m 2 g\u00f6vde, 63\/125 A; Tasar\u0131m 2 g\u00f6vde, 16\/32 A; Standart g\u00f6vde, 63\/125 A; 3s \u00f6zel konfig\u00fcrasyonlar<\/td>\n<\/tr>\n<tr>\n<td>Model se\u00e7enekleri<\/td>\n<td>28<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Model Se\u00e7im Tablolar\u0131<\/h2>\n<p>Voltaj ve ak\u0131m de\u011ferleri tam model sat\u0131r\u0131na aittir. Bir tire, sa\u011flanan verilerde modele \u00f6zel bir de\u011ferin mevcut olmad\u0131\u011f\u0131n\u0131 g\u00f6sterir.<\/p>\n<h3>Tasar\u0131m 1 g\u00f6vde, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Anma ak\u0131m\u0131 (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Toprak konumu<\/th>\n<th>Renk<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1131-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>Sar\u0131<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1231-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>Sar\u0131<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1131<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1231<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1141<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1241<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1151<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1251<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Anma ak\u0131m\u0131 (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Toprak konumu<\/th>\n<th>Renk<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1332<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-1432<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-1342<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-1442<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-1352<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-1452<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Anma ak\u0131m\u0131 (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Toprak konumu<\/th>\n<th>Renk<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1132<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1232<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1142<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1242<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1152<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1252<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Standard housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Anma ak\u0131m\u0131 (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Toprak konumu<\/th>\n<th>Renk<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-133<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-143<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Mavi<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-134<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-144<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-135<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-145<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>3h special configurations<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Anma ak\u0131m\u0131 (A)<\/th>\n<th>Kontaklar<\/th>\n<th>Voltaj (V)<\/th>\n<th>Toprak konumu<\/th>\n<th>Renk<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1142-3<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>3h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-1242-3<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>3h<\/td>\n<td>K\u0131rm\u0131z\u0131<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Boyut<\/h2>\n<p>Dimension letters apply to the individual housing drawing. The same letter can identify a different feature on another housing version. Select the mounting dimensions from the exact model row.<\/p>\n<h3>Tasar\u0131m 1 g\u00f6vde, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>e1 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1131-4<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>115<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1231-4<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>143<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1131<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>115<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1231<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>143<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1141<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>124<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1241<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>143<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1151<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>124<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1251<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>150<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1332<\/td>\n<td>176<\/td>\n<td>171<\/td>\n<td>225<\/td>\n<td>119<\/td>\n<td>136<\/td>\n<td>103<\/td>\n<\/tr>\n<tr>\n<td>NM-1432<\/td>\n<td>180<\/td>\n<td>260<\/td>\n<td>305<\/td>\n<td>160<\/td>\n<td>241<\/td>\n<td>141<\/td>\n<\/tr>\n<tr>\n<td>NM-1342<\/td>\n<td>176<\/td>\n<td>171<\/td>\n<td>225<\/td>\n<td>119<\/td>\n<td>136<\/td>\n<td>103<\/td>\n<\/tr>\n<tr>\n<td>NM-1442<\/td>\n<td>180<\/td>\n<td>260<\/td>\n<td>305<\/td>\n<td>160<\/td>\n<td>241<\/td>\n<td>141<\/td>\n<\/tr>\n<tr>\n<td>NM-1352<\/td>\n<td>176<\/td>\n<td>171<\/td>\n<td>225<\/td>\n<td>119<\/td>\n<td>136<\/td>\n<td>103<\/td>\n<\/tr>\n<tr>\n<td>NM-1452<\/td>\n<td>180<\/td>\n<td>260<\/td>\n<td>305<\/td>\n<td>160<\/td>\n<td>241<\/td>\n<td>141<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1132<\/td>\n<td>145<\/td>\n<td>99<\/td>\n<\/tr>\n<tr>\n<td>NM-1232<\/td>\n<td>160<\/td>\n<td>108<\/td>\n<\/tr>\n<tr>\n<td>NM-1142<\/td>\n<td>150<\/td>\n<td>101<\/td>\n<\/tr>\n<tr>\n<td>NM-1242<\/td>\n<td>160<\/td>\n<td>108<\/td>\n<\/tr>\n<tr>\n<td>NM-1152<\/td>\n<td>150<\/td>\n<td>106<\/td>\n<\/tr>\n<tr>\n<td>NM-1252<\/td>\n<td>161<\/td>\n<td>111<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Base width 82; fixing width 71; vertical spacings 16, 48 and 40; side drawing 103.<\/p>\n<h3>Standard housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<th>g (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-133<\/td>\n<td>134<\/td>\n<td>311<\/td>\n<td>108<\/td>\n<td>111<\/td>\n<td>20<\/td>\n<td>155<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>NM-143<\/td>\n<td>154<\/td>\n<td>338<\/td>\n<td>122<\/td>\n<td>130<\/td>\n<td>20<\/td>\n<td>187<\/td>\n<td>6.2<\/td>\n<\/tr>\n<tr>\n<td>NM-134<\/td>\n<td>134<\/td>\n<td>311<\/td>\n<td>108<\/td>\n<td>111<\/td>\n<td>20<\/td>\n<td>155<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>NM-144<\/td>\n<td>154<\/td>\n<td>338<\/td>\n<td>122<\/td>\n<td>130<\/td>\n<td>20<\/td>\n<td>187<\/td>\n<td>6.2<\/td>\n<\/tr>\n<tr>\n<td>NM-135<\/td>\n<td>134<\/td>\n<td>311<\/td>\n<td>108<\/td>\n<td>111<\/td>\n<td>20<\/td>\n<td>155<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>NM-145<\/td>\n<td>154<\/td>\n<td>338<\/td>\n<td>122<\/td>\n<td>130<\/td>\n<td>20<\/td>\n<td>187<\/td>\n<td>6.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Cable-entry drawing PG29.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-02.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-03.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-04.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-05.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<h2>Se\u00e7im K\u0131lavuzu<\/h2>\n<ol>\n<li>Choose the rated current and contact arrangement required for the connection.<\/li>\n<li>Match the voltage configuration and earth contact position to the mating plug. Colour alone is insufficient for model selection.<\/li>\n<li>Select the housing version and use its own mounting and conductor-range values.<\/li>\n<li>Include the complete model code and quantity in the enquiry.<\/li>\n<\/ol>\n<h2>Sipari\u015f Bilgileri<\/h2>\n<p>For a quotation, provide the complete NM model code, required quantity and mounting version. If identifying a replacement, include a photograph of the existing contact face and mounting layout.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELEKTR\u0130K IP67 sabit end\u00fcstriyel g\u00fc\u00e7 ba\u011flant\u0131lar\u0131 i\u00e7in y\u00fczeye monte end\u00fcstriyel prizler.<\/p>\n<ul>\n<li>Ak\u0131m de\u011ferleri: 16 \/ 32 \/ 63 \/ 125 A.<\/li>\n<li>Kontak d\u00fczenleri: 2P+E \/ 3P+E \/ 3P+N+E.<\/li>\n<li>Mente\u015feli kapakl\u0131 ve arka montajl\u0131 muhafazal\u0131 di\u015fi priz.<\/li>\n<li>Tam model se\u00e7im tablolar\u0131 voltaj, toprak konta\u011f\u0131 konumu, iletken aral\u0131klar\u0131 ve muhafazaya \u00f6zg\u00fc boyutlar\u0131 i\u00e7erir.<\/li>\n<li>Tam NM model kodu ile se\u00e7in ve sorgulay\u0131n.<\/li>\n<\/ul>","protected":false},"featured_media":2898,"template":"","meta":[],"product_brand":[],"product_cat":[54],"product_tag":[],"class_list":["post-2904","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-sockets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/2904","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/2898"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=2904"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=2904"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=2904"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=2904"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}