{"id":690,"date":"2026-09-29T11:31:21","date_gmt":"2026-09-29T11:31:21","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=690"},"modified":"2026-10-02T13:51:32","modified_gmt":"2026-10-02T13:51:32","slug":"easy-entry-insulated-spade-terminal","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/easy-entry-insulated-spade-terminal\/","title":{"rendered":"Easy Entry Insulated Spade Terminal"},"content":{"rendered":"<h2>Overview<\/h2>\n<p>YOCL ELECTRIC Easy Entry Insulated Spade Terminal is an open-fork copper terminal with a PVC insulated barrel for bolted electrical connections. The supplied catalog shows 22 specification rows in red and blue conductor groups, covering 0.5\u20132.5 mm\u00b2 conductors. The fork shape allows the terminal to be positioned at a compatible bolt or stud connection.<\/p>\n<h2>Features<\/h2>\n<ul>\n<li><strong>Open-fork contact:<\/strong> the spade end fits a suitably sized bolt or stud connection.<\/li>\n<li><strong>Copper terminal:<\/strong> the catalog identifies the conductive terminal material as copper.<\/li>\n<li><strong>PVC sleeve:<\/strong> the red and blue groups are identified as PVC insulated.<\/li>\n<li><strong>Two colour groups:<\/strong> red and blue correspond to different conductor ranges and maximum current values.<\/li>\n<li><strong>Model-level fit:<\/strong> bolt designation, metric bolt diameter and key dimensions are listed for each catalog row.<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Product type<\/td>\n<td>Easy entry insulated spade terminal<\/td>\n<\/tr>\n<tr>\n<td>Terminal material<\/td>\n<td>Copper<\/td>\n<\/tr>\n<tr>\n<td>Insulation<\/td>\n<td>PVC<\/td>\n<\/tr>\n<tr>\n<td>Listed specification rows<\/td>\n<td>22<\/td>\n<\/tr>\n<tr>\n<td>Conductor range across listed groups<\/td>\n<td>0.5\u20132.5 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td>Maximum temperature stated in source<\/td>\n<td>75 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Dimension units<\/td>\n<td>mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The source gives the following values by colour group. Imax is the source&#8217;s maximum-current label; it is not presented as a continuous rated current.<\/p>\n<table>\n<thead>\n<tr>\n<th>Colour<\/th>\n<th>Conductor range<\/th>\n<th>AWG<\/th>\n<th>Imax<\/th>\n<th>B (mm)<\/th>\n<th>D (mm)<\/th>\n<th>d1 (mm)<\/th>\n<th>T (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Red<\/td>\n<td>0.5\u20131.5 mm\u00b2<\/td>\n<td>22\u201316<\/td>\n<td>19 A<\/td>\n<td>10.0<\/td>\n<td>4.2<\/td>\n<td>1.7<\/td>\n<td>0.7<\/td>\n<\/tr>\n<tr>\n<td>Blue<\/td>\n<td>1.5\u20132.5 mm\u00b2<\/td>\n<td>16\u201314<\/td>\n<td>27 A<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<td>2.3<\/td>\n<td>0.8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimension<\/h2>\n<p>The drawing labels d2 as the fork opening, W as fork width, F as the fork-side length, L as total length, B as the barrel-side length, D as the insulated barrel width, d1 as the inner barrel opening and T as contact thickness. The source separately lists a nominal metric bolt diameter and a US bolt designation. All dimensional values are in millimeters.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Colour<\/th>\n<th>US bolt no.<\/th>\n<th>Bolt dia. (mm)<\/th>\n<th>d2 (mm)<\/th>\n<th>W (mm)<\/th>\n<th>F (mm)<\/th>\n<th>L (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SE1.25-3<\/td>\n<td>Red<\/td>\n<td>#4<\/td>\n<td>3<\/td>\n<td>3.2<\/td>\n<td>5.7<\/td>\n<td>6.5<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SES1.25-3.5<\/td>\n<td>Red<\/td>\n<td>#6<\/td>\n<td>3.5<\/td>\n<td>3.7<\/td>\n<td>5.7<\/td>\n<td>6.5<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SEL1.25-3.5<\/td>\n<td>Red<\/td>\n<td>#6<\/td>\n<td>3.5<\/td>\n<td>3.7<\/td>\n<td>6.4<\/td>\n<td>6.5<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SES1.25-4<\/td>\n<td>Red<\/td>\n<td>#8<\/td>\n<td>4<\/td>\n<td>4.3<\/td>\n<td>6.4<\/td>\n<td>6.5<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SEM1.25-4<\/td>\n<td>Red<\/td>\n<td>#8<\/td>\n<td>4<\/td>\n<td>4.3<\/td>\n<td>7.2<\/td>\n<td>6.5<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SEL1.25-4<\/td>\n<td>Red<\/td>\n<td>#8<\/td>\n<td>4<\/td>\n<td>4.3<\/td>\n<td>8.1<\/td>\n<td>6.5<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SES1.25-5<\/td>\n<td>Red<\/td>\n<td>#10<\/td>\n<td>5<\/td>\n<td>5.3<\/td>\n<td>8.1<\/td>\n<td>6.5<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SEL1.25-5<\/td>\n<td>Red<\/td>\n<td>#10<\/td>\n<td>5<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<\/tr>\n<tr>\n<td>SES1.25-5<\/td>\n<td>Red<\/td>\n<td>1\/4\u2033<\/td>\n<td>6<\/td>\n<td>6.4<\/td>\n<td>9.5<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<\/tr>\n<tr>\n<td>SES1.25-6<\/td>\n<td>Red<\/td>\n<td>1\/4\u2033<\/td>\n<td>6<\/td>\n<td>6.4<\/td>\n<td>12.0<\/td>\n<td>11.0<\/td>\n<td>27.0<\/td>\n<\/tr>\n<tr>\n<td>SE1.25-6<\/td>\n<td>Red<\/td>\n<td>5\/16\u2033<\/td>\n<td>8<\/td>\n<td>8.4<\/td>\n<td>14.0<\/td>\n<td>12.5<\/td>\n<td>29.0<\/td>\n<\/tr>\n<tr>\n<td>SE2-3<\/td>\n<td>Blue<\/td>\n<td>#4<\/td>\n<td>3<\/td>\n<td>3.2<\/td>\n<td>5.7<\/td>\n<td>6.5<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SES2-3.5<\/td>\n<td>Blue<\/td>\n<td>#6<\/td>\n<td>3.5<\/td>\n<td>3.7<\/td>\n<td>5.7<\/td>\n<td>6.5<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SEL2-3.5<\/td>\n<td>Blue<\/td>\n<td>#6<\/td>\n<td>3.5<\/td>\n<td>3.7<\/td>\n<td>6.4<\/td>\n<td>\u2014<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SES2-4<\/td>\n<td>Blue<\/td>\n<td>#8<\/td>\n<td>4<\/td>\n<td>4.3<\/td>\n<td>6.4<\/td>\n<td>6.5<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SEM2-4<\/td>\n<td>Blue<\/td>\n<td>#8<\/td>\n<td>4<\/td>\n<td>4.3<\/td>\n<td>7.2<\/td>\n<td>\u2014<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SEL2-4<\/td>\n<td>Blue<\/td>\n<td>#8<\/td>\n<td>4<\/td>\n<td>4.3<\/td>\n<td>7.9<\/td>\n<td>6.5<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SES2-5<\/td>\n<td>Blue<\/td>\n<td>#10<\/td>\n<td>5<\/td>\n<td>5.3<\/td>\n<td>7.9<\/td>\n<td>6.5<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SEL2-5<\/td>\n<td>Blue<\/td>\n<td>#10<\/td>\n<td>5<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>6.5<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SES2-6<\/td>\n<td>Blue<\/td>\n<td>1\/4\u2033<\/td>\n<td>6<\/td>\n<td>6.4<\/td>\n<td>9.5<\/td>\n<td>6.5<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>SEL2-6<\/td>\n<td>Blue<\/td>\n<td>1\/4\u2033<\/td>\n<td>6<\/td>\n<td>6.4<\/td>\n<td>12.0<\/td>\n<td>11.0<\/td>\n<td>27.0<\/td>\n<\/tr>\n<tr>\n<td>SE2-8<\/td>\n<td>Blue<\/td>\n<td>5\/16\u2033<\/td>\n<td>8<\/td>\n<td>8.4<\/td>\n<td>14.0<\/td>\n<td>12.5<\/td>\n<td>29.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>B, D, d1 and T apply by colour group as shown in Technical Specifications. A dash means the source table leaves that value blank. The supplied catalog lists SES1.25-5 at both 5 mm and 6 mm nominal bolt diameters; both rows are retained as printed.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/09\/easy-entry-insulated-spade-terminal-dimension.webp\" alt=\"Easy Entry Insulated Spade Terminal dimension drawing\" \/><\/p>\n<h2>Selection Guide<\/h2>\n<p>Choose the red or blue group for the conductor range, then check the bolt or stud against the nominal bolt diameter and actual fork opening d2. Compare W, F, L and the group-level barrel dimensions with the connection space. For the two SES1.25-5 rows, identify the required bolt diameter when making an inquiry.<\/p>\n<h2>Uygulamalar<\/h2>\n<p>Insulated conductor terminations at compatible bolted equipment terminals.<\/p>\n<h2>Ordering Information<\/h2>\n<p>Specify the exact model, bolt diameter and quantity when requesting a quotation.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC Easy Entry Insulated Spade Terminal combines a copper open-fork contact with a PVC insulated barrel for bolted terminal connections. The reference lists 22 specification rows across red 0.5\u20131.5 mm\u00b2 and blue 1.5\u20132.5 mm\u00b2 conductor groups.<\/p>\n<ul>\n<li>Select by conductor range and bolt-hole diameter.<\/li>\n<li>Model-level d2, W, F and L dimensions are listed below.<\/li>\n<li>Group-level B, D, d1 and T dimensions are retained from the catalog.<\/li>\n<\/ul>","protected":false},"featured_media":1792,"template":"","meta":[],"product_brand":[],"product_cat":[158],"product_tag":[],"class_list":["post-690","product","type-product","status-publish","has-post-thumbnail","product_cat-pvc-insulated-terminals","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/690","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/1792"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=690"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=690"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=690"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=690"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}