{"id":825,"date":"2026-09-29T15:35:04","date_gmt":"2026-09-29T15:35:04","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=825"},"modified":"2026-10-04T11:14:02","modified_gmt":"2026-10-04T11:14:02","slug":"en-non-insulated-cord-end-ferrules","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/en-non-insulated-cord-end-ferrules\/","title":{"rendered":"EN Non-Insulated Cord End Ferrules"},"content":{"rendered":"<h2>Genel Bak\u0131\u015f<\/h2>\n<p>YOCL ELECTRIC EN Non-Insulated Cord End Ferrules are tubular wire ferrules for terminating conductors. A flared entry is shown in the dimension drawing. The EN series covers 0.2\u2013185 mm\u00b2 across 68 listed models, with different lengths for each conductor section.<\/p>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li><strong>Uninsulated tube:<\/strong> a bare cord end ferrule without an insulating collar.<\/li>\n<li><strong>Flared entry:<\/strong> the mouth width W is specified separately from the tube diameter D.<\/li>\n<li><strong>Multiple lengths:<\/strong> select the L dimension required for the connection.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Series<\/td>\n<td>EN<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Non-insulated cord end ferrule<\/td>\n<\/tr>\n<tr>\n<td>Insulation<\/td>\n<td>None<\/td>\n<\/tr>\n<tr>\n<td>Conductor sections<\/td>\n<td>0.2\u2013185 mm\u00b2 across the series<\/td>\n<\/tr>\n<tr>\n<td>Listed models<\/td>\n<td>68<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Boyut<\/h2>\n<p>All dimensions are in millimeters. L is overall length; D and C are the outside and inside tube diameters shown in the drawing; W is the flared entry width.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Lead section (mm\u00b2)<\/th>\n<th>AWG<\/th>\n<th>L (mm)<\/th>\n<th>D (mm)<\/th>\n<th>C (mm)<\/th>\n<th>W (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>EN0206<\/td>\n<td>0.2<\/td>\n<td>#26<\/td>\n<td>6.0<\/td>\n<td>1.1<\/td>\n<td>0.8<\/td>\n<td>1.4<\/td>\n<\/tr>\n<tr>\n<td>EN0207<\/td>\n<td>0.2<\/td>\n<td>#26<\/td>\n<td>7.0<\/td>\n<td>1.1<\/td>\n<td>0.8<\/td>\n<td>1.4<\/td>\n<\/tr>\n<tr>\n<td>EN0208<\/td>\n<td>0.2<\/td>\n<td>#26<\/td>\n<td>8.0<\/td>\n<td>1.1<\/td>\n<td>0.8<\/td>\n<td>1.4<\/td>\n<\/tr>\n<tr>\n<td>EN0306<\/td>\n<td>0.3<\/td>\n<td>#24<\/td>\n<td>6.0<\/td>\n<td>1.3<\/td>\n<td>1.0<\/td>\n<td>1.5<\/td>\n<\/tr>\n<tr>\n<td>EN0308<\/td>\n<td>0.3<\/td>\n<td>#24<\/td>\n<td>8.0<\/td>\n<td>1.3<\/td>\n<td>1.0<\/td>\n<td>1.5<\/td>\n<\/tr>\n<tr>\n<td>EN0505<\/td>\n<td>0.5<\/td>\n<td>#22<\/td>\n<td>5.0<\/td>\n<td>1.3<\/td>\n<td>1.0<\/td>\n<td>1.7<\/td>\n<\/tr>\n<tr>\n<td>EN0506<\/td>\n<td>0.5<\/td>\n<td>#22<\/td>\n<td>6.0<\/td>\n<td>1.3<\/td>\n<td>1.0<\/td>\n<td>1.7<\/td>\n<\/tr>\n<tr>\n<td>EN0508<\/td>\n<td>0.5<\/td>\n<td>#22<\/td>\n<td>8.0<\/td>\n<td>1.3<\/td>\n<td>1.0<\/td>\n<td>1.7<\/td>\n<\/tr>\n<tr>\n<td>EN0510<\/td>\n<td>0.5<\/td>\n<td>#22<\/td>\n<td>10.0<\/td>\n<td>1.3<\/td>\n<td>1.0<\/td>\n<td>1.7<\/td>\n<\/tr>\n<tr>\n<td>EN0512<\/td>\n<td>0.5<\/td>\n<td>#22<\/td>\n<td>12.0<\/td>\n<td>1.3<\/td>\n<td>1.0<\/td>\n<td>1.7<\/td>\n<\/tr>\n<tr>\n<td>EN7506<\/td>\n<td>0.75<\/td>\n<td>#20<\/td>\n<td>6.0<\/td>\n<td>1.5<\/td>\n<td>1.2<\/td>\n<td>1.9<\/td>\n<\/tr>\n<tr>\n<td>EN7508<\/td>\n<td>0.75<\/td>\n<td>#20<\/td>\n<td>8.0<\/td>\n<td>1.5<\/td>\n<td>1.2<\/td>\n<td>1.9<\/td>\n<\/tr>\n<tr>\n<td>EN7510<\/td>\n<td>0.75<\/td>\n<td>#20<\/td>\n<td>10.0<\/td>\n<td>1.5<\/td>\n<td>1.2<\/td>\n<td>1.9<\/td>\n<\/tr>\n<tr>\n<td>EN7512<\/td>\n<td>0.75<\/td>\n<td>#20<\/td>\n<td>12.0<\/td>\n<td>1.5<\/td>\n<td>1.2<\/td>\n<td>1.9<\/td>\n<\/tr>\n<tr>\n<td>EN1006<\/td>\n<td>1.0<\/td>\n<td>#18<\/td>\n<td>6.0<\/td>\n<td>1.8<\/td>\n<td>1.5<\/td>\n<td>2.2<\/td>\n<\/tr>\n<tr>\n<td>EN1008<\/td>\n<td>1.0<\/td>\n<td>#18<\/td>\n<td>8.0<\/td>\n<td>1.8<\/td>\n<td>1.5<\/td>\n<td>2.2<\/td>\n<\/tr>\n<tr>\n<td>EN1010<\/td>\n<td>1.0<\/td>\n<td>#18<\/td>\n<td>10.0<\/td>\n<td>1.8<\/td>\n<td>1.5<\/td>\n<td>2.2<\/td>\n<\/tr>\n<tr>\n<td>EN1012<\/td>\n<td>1.0<\/td>\n<td>#18<\/td>\n<td>12.0<\/td>\n<td>1.8<\/td>\n<td>1.5<\/td>\n<td>2.2<\/td>\n<\/tr>\n<tr>\n<td>EN1507<\/td>\n<td>1.5<\/td>\n<td>#16<\/td>\n<td>7.0<\/td>\n<td>2.0<\/td>\n<td>1.7<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<td>EN1508<\/td>\n<td>1.5<\/td>\n<td>#16<\/td>\n<td>8.0<\/td>\n<td>2.0<\/td>\n<td>1.7<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<td>EN1510<\/td>\n<td>1.5<\/td>\n<td>#16<\/td>\n<td>10.0<\/td>\n<td>2.0<\/td>\n<td>1.7<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<td>EN1512<\/td>\n<td>1.5<\/td>\n<td>#16<\/td>\n<td>12.0<\/td>\n<td>2.0<\/td>\n<td>1.7<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<td>EN1518<\/td>\n<td>1.5<\/td>\n<td>#16<\/td>\n<td>18.0<\/td>\n<td>2.0<\/td>\n<td>1.7<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<td>EN2507<\/td>\n<td>2.5<\/td>\n<td>#14<\/td>\n<td>7.0<\/td>\n<td>2.6<\/td>\n<td>2.3<\/td>\n<td>3.3<\/td>\n<\/tr>\n<tr>\n<td>EN2508<\/td>\n<td>2.5<\/td>\n<td>#14<\/td>\n<td>8.0<\/td>\n<td>2.6<\/td>\n<td>2.3<\/td>\n<td>3.3<\/td>\n<\/tr>\n<tr>\n<td>EN2510<\/td>\n<td>2.5<\/td>\n<td>#14<\/td>\n<td>10.0<\/td>\n<td>2.6<\/td>\n<td>2.3<\/td>\n<td>3.3<\/td>\n<\/tr>\n<tr>\n<td>EN2512<\/td>\n<td>2.5<\/td>\n<td>#14<\/td>\n<td>12.0<\/td>\n<td>2.6<\/td>\n<td>2.3<\/td>\n<td>3.3<\/td>\n<\/tr>\n<tr>\n<td>EN2518<\/td>\n<td>2.5<\/td>\n<td>#14<\/td>\n<td>18.0<\/td>\n<td>2.6<\/td>\n<td>2.3<\/td>\n<td>3.3<\/td>\n<\/tr>\n<tr>\n<td>EN4009<\/td>\n<td>4.0<\/td>\n<td>#12<\/td>\n<td>9.0<\/td>\n<td>3.2<\/td>\n<td>2.8<\/td>\n<td>3.9<\/td>\n<\/tr>\n<tr>\n<td>EN4012<\/td>\n<td>4.0<\/td>\n<td>#12<\/td>\n<td>12.0<\/td>\n<td>3.2<\/td>\n<td>2.8<\/td>\n<td>3.9<\/td>\n<\/tr>\n<tr>\n<td>EN4018<\/td>\n<td>4.0<\/td>\n<td>#12<\/td>\n<td>18.0<\/td>\n<td>3.2<\/td>\n<td>2.8<\/td>\n<td>3.9<\/td>\n<\/tr>\n<tr>\n<td>EN6010<\/td>\n<td>6.0<\/td>\n<td>#10<\/td>\n<td>10.0<\/td>\n<td>3.9<\/td>\n<td>3.5<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>EN6012<\/td>\n<td>6.0<\/td>\n<td>#10<\/td>\n<td>12.0<\/td>\n<td>3.9<\/td>\n<td>3.5<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>EN6015<\/td>\n<td>6.0<\/td>\n<td>#10<\/td>\n<td>15.0<\/td>\n<td>3.9<\/td>\n<td>3.5<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>EN6018<\/td>\n<td>6.0<\/td>\n<td>#10<\/td>\n<td>18.0<\/td>\n<td>3.9<\/td>\n<td>3.5<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>EN10-12<\/td>\n<td>10.0<\/td>\n<td>#7<\/td>\n<td>12.0<\/td>\n<td>4.9<\/td>\n<td>4.5<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>EN10-15<\/td>\n<td>10.0<\/td>\n<td>#7<\/td>\n<td>15.0<\/td>\n<td>4.9<\/td>\n<td>4.5<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>EN10-18<\/td>\n<td>10.0<\/td>\n<td>#7<\/td>\n<td>18.0<\/td>\n<td>4.9<\/td>\n<td>4.5<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>EN16-12<\/td>\n<td>16.0<\/td>\n<td>#5<\/td>\n<td>12.0<\/td>\n<td>6.2<\/td>\n<td>5.8<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td>EN16-15<\/td>\n<td>16.0<\/td>\n<td>#5<\/td>\n<td>15.0<\/td>\n<td>6.2<\/td>\n<td>5.8<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td>EN16-18<\/td>\n<td>16.0<\/td>\n<td>#5<\/td>\n<td>18.0<\/td>\n<td>6.2<\/td>\n<td>5.8<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td>EN25-16<\/td>\n<td>25.0<\/td>\n<td>#4<\/td>\n<td>16.0<\/td>\n<td>7.9<\/td>\n<td>7.5<\/td>\n<td>9.1<\/td>\n<\/tr>\n<tr>\n<td>EN25-22<\/td>\n<td>25.0<\/td>\n<td>#4<\/td>\n<td>22.0<\/td>\n<td>7.9<\/td>\n<td>7.5<\/td>\n<td>9.1<\/td>\n<\/tr>\n<tr>\n<td>EN35-16<\/td>\n<td>35.0<\/td>\n<td>#2<\/td>\n<td>16.0<\/td>\n<td>8.7<\/td>\n<td>8.3<\/td>\n<td>10.2<\/td>\n<\/tr>\n<tr>\n<td>EN35-25<\/td>\n<td>35.0<\/td>\n<td>#2<\/td>\n<td>25.0<\/td>\n<td>8.7<\/td>\n<td>8.3<\/td>\n<td>10.2<\/td>\n<\/tr>\n<tr>\n<td>EN50-20<\/td>\n<td>50.0<\/td>\n<td>#1<\/td>\n<td>20.0<\/td>\n<td>10.9<\/td>\n<td>10.3<\/td>\n<td>12.4<\/td>\n<\/tr>\n<tr>\n<td>EN50-25<\/td>\n<td>50.0<\/td>\n<td>#1<\/td>\n<td>25.0<\/td>\n<td>10.9<\/td>\n<td>10.3<\/td>\n<td>12.4<\/td>\n<\/tr>\n<tr>\n<td>EN50-30<\/td>\n<td>50.0<\/td>\n<td>1\/0<\/td>\n<td>30.0<\/td>\n<td>10.9<\/td>\n<td>10.3<\/td>\n<td>12.7<\/td>\n<\/tr>\n<tr>\n<td>EN50-32<\/td>\n<td>50.0<\/td>\n<td>1\/0<\/td>\n<td>32.0<\/td>\n<td>10.9<\/td>\n<td>10.3<\/td>\n<td>12.7<\/td>\n<\/tr>\n<tr>\n<td>EN70-22<\/td>\n<td>70.0<\/td>\n<td>2\/0<\/td>\n<td>22.0<\/td>\n<td>14.3<\/td>\n<td>13.5<\/td>\n<td>15.8<\/td>\n<\/tr>\n<tr>\n<td>EN70-25<\/td>\n<td>70.0<\/td>\n<td>2\/0<\/td>\n<td>25.0<\/td>\n<td>14.3<\/td>\n<td>13.5<\/td>\n<td>15.8<\/td>\n<\/tr>\n<tr>\n<td>EN70-30<\/td>\n<td>70.0<\/td>\n<td>2\/0<\/td>\n<td>30.0<\/td>\n<td>14.3<\/td>\n<td>13.5<\/td>\n<td>15.8<\/td>\n<\/tr>\n<tr>\n<td>EN70-32<\/td>\n<td>70.0<\/td>\n<td>2\/0<\/td>\n<td>32.0<\/td>\n<td>14.3<\/td>\n<td>13.5<\/td>\n<td>15.8<\/td>\n<\/tr>\n<tr>\n<td>EN95-25<\/td>\n<td>95.0<\/td>\n<td>3\/0<\/td>\n<td>25.0<\/td>\n<td>15.3<\/td>\n<td>14.5<\/td>\n<td>17.3<\/td>\n<\/tr>\n<tr>\n<td>EN95-30<\/td>\n<td>95.0<\/td>\n<td>3\/0<\/td>\n<td>30.0<\/td>\n<td>15.3<\/td>\n<td>14.5<\/td>\n<td>17.3<\/td>\n<\/tr>\n<tr>\n<td>EN95-32<\/td>\n<td>95.0<\/td>\n<td>3\/0<\/td>\n<td>32.0<\/td>\n<td>15.3<\/td>\n<td>14.5<\/td>\n<td>17.3<\/td>\n<\/tr>\n<tr>\n<td>EN95-34<\/td>\n<td>95.0<\/td>\n<td>3\/0<\/td>\n<td>34.0<\/td>\n<td>15.3<\/td>\n<td>14.5<\/td>\n<td>17.3<\/td>\n<\/tr>\n<tr>\n<td>EN120-30<\/td>\n<td>120.0<\/td>\n<td>4\/0<\/td>\n<td>30.0<\/td>\n<td>17.5<\/td>\n<td>16.5<\/td>\n<td>20.2<\/td>\n<\/tr>\n<tr>\n<td>EN120-32<\/td>\n<td>120.0<\/td>\n<td>4\/0<\/td>\n<td>32.0<\/td>\n<td>17.5<\/td>\n<td>16.5<\/td>\n<td>20.2<\/td>\n<\/tr>\n<tr>\n<td>EN120-34<\/td>\n<td>120.0<\/td>\n<td>4\/0<\/td>\n<td>34.0<\/td>\n<td>17.5<\/td>\n<td>16.5<\/td>\n<td>20.2<\/td>\n<\/tr>\n<tr>\n<td>EN120-38<\/td>\n<td>120.0<\/td>\n<td>4\/0<\/td>\n<td>38.0<\/td>\n<td>17.5<\/td>\n<td>16.5<\/td>\n<td>20.2<\/td>\n<\/tr>\n<tr>\n<td>EN120-40<\/td>\n<td>120.0<\/td>\n<td>4\/0<\/td>\n<td>40.0<\/td>\n<td>17.5<\/td>\n<td>16.5<\/td>\n<td>20.2<\/td>\n<\/tr>\n<tr>\n<td>EN150-32<\/td>\n<td>150.0<\/td>\n<td>250\/300<\/td>\n<td>32.0<\/td>\n<td>20.6<\/td>\n<td>19.6<\/td>\n<td>23.0<\/td>\n<\/tr>\n<tr>\n<td>EN150-34<\/td>\n<td>150.0<\/td>\n<td>250\/300<\/td>\n<td>34.0<\/td>\n<td>20.6<\/td>\n<td>19.6<\/td>\n<td>23.0<\/td>\n<\/tr>\n<tr>\n<td>EN150-38<\/td>\n<td>150.0<\/td>\n<td>250\/300<\/td>\n<td>38.0<\/td>\n<td>20.6<\/td>\n<td>19.6<\/td>\n<td>23.0<\/td>\n<\/tr>\n<tr>\n<td>EN150-40<\/td>\n<td>150.0<\/td>\n<td>250\/300<\/td>\n<td>40.0<\/td>\n<td>20.6<\/td>\n<td>19.6<\/td>\n<td>23.0<\/td>\n<\/tr>\n<tr>\n<td>EN185-32<\/td>\n<td>185.0<\/td>\n<td>250\/300<\/td>\n<td>32.0<\/td>\n<td>21.4<\/td>\n<td>20.2<\/td>\n<td>23.9<\/td>\n<\/tr>\n<tr>\n<td>EN185-40<\/td>\n<td>185.0<\/td>\n<td>250\/300<\/td>\n<td>40.0<\/td>\n<td>21.4<\/td>\n<td>20.2<\/td>\n<td>23.9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/09\/en-non-insulated-cord-end-ferrules-dimension.webp\" alt=\"EN Non-Insulated Cord End Ferrules dimension drawing\" \/><\/p>\n<h2>Se\u00e7im K\u0131lavuzu<\/h2>\n<p>Select the conductor section and check the listed L, D, C and W dimensions against the intended termination. The 50 mm\u00b2 entries include two mouth widths and AWG designations; use the complete model number when ordering.<\/p>\n<h2>Sipari\u015f Bilgileri<\/h2>\n<p>Provide the full EN model and required quantity when requesting a quotation.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC EN Non-Insulated Cord End Ferrules are tubular wire ferrules with a flared entry. The 68 listed models cover conductor sections from 0.2 to 185 mm\u00b2, with several tube lengths for each size.<\/p>\n<ul>\n<li>Uninsulated tubular design with a flared wire entry.<\/li>\n<li>Model-specific L, D, C and W dimensions.<\/li>\n<li>Select by conductor section, AWG designation and tube length.<\/li>\n<\/ul>","protected":false},"featured_media":2048,"template":"","meta":[],"product_brand":[],"product_cat":[35],"product_tag":[],"class_list":["post-825","product","type-product","status-publish","has-post-thumbnail","product_cat-wire-ferrules","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/825","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/2048"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=825"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=825"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=825"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}