{"id":858,"date":"2026-09-29T16:06:05","date_gmt":"2026-09-29T16:06:05","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=858"},"modified":"2026-10-04T11:17:32","modified_gmt":"2026-10-04T11:17:32","slug":"fdh-heat-shrinkable-female-terminals","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/fdh-heat-shrinkable-female-terminals\/","title":{"rendered":"FDH Heat Shrinkable Female Terminals"},"content":{"rendered":"<h2>Genel Bak\u0131\u015f<\/h2>\n<p>FDH Heat Shrinkable Female Terminals are copper female tab receptacles with a heat-shrink sleeve. The supplied catalog lists 22 models across three conductor groups. Select the female terminal by conductor section, mating tab size and the dimensions of the connection.<\/p>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li><strong>Heat-shrink sleeve:<\/strong> the catalog specifies an initial shrink temperature of 80 \u00b0C and a minimum temperature of 130 \u00b0C for complete shrinkage.<\/li>\n<li><strong>Copper terminal:<\/strong> the conductive terminal material is listed as copper.<\/li>\n<li><strong>Three conductor groups:<\/strong> red, blue and yellow models cover different conductor sections and dimensional sizes.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>Catalog specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Product type<\/td>\n<td>Heat shrinkable female terminal<\/td>\n<\/tr>\n<tr>\n<td>Seri<\/td>\n<td>FDH<\/td>\n<\/tr>\n<tr>\n<td>Listed models<\/td>\n<td>22<\/td>\n<\/tr>\n<tr>\n<td>Terminal material<\/td>\n<td>Copper<\/td>\n<\/tr>\n<tr>\n<td>Heat-shrink sleeve material<\/td>\n<td>Not specified in the source<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>\u221255 to +125 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Initial shrink temperature<\/td>\n<td>80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Minimum complete shrink temperature<\/td>\n<td>130 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Dimension units<\/td>\n<td>mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The catalog labels the current figures as Imax for each conductor group. It does not provide test conditions, an IP rating or a voltage rating.<\/p>\n<table>\n<thead>\n<tr>\n<th>Group<\/th>\n<th>Conductor section<\/th>\n<th>AWG<\/th>\n<th>Catalog Imax<\/th>\n<th>Color<\/th>\n<th>D (mm)<\/th>\n<th>d (mm)<\/th>\n<th>E (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>FDH 1.25<\/td>\n<td>0.5\u20131.5 mm\u00b2<\/td>\n<td>22\u201316<\/td>\n<td>19 A<\/td>\n<td>Red<\/td>\n<td>4.8<\/td>\n<td>1.7<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 2<\/td>\n<td>1.5\u20132.5 mm\u00b2<\/td>\n<td>16\u201314<\/td>\n<td>27 A<\/td>\n<td>Blue<\/td>\n<td>5.8<\/td>\n<td>2.3<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 5.5<\/td>\n<td>4\u20136 mm\u00b2<\/td>\n<td>12\u201310<\/td>\n<td>48 A<\/td>\n<td>Yellow<\/td>\n<td>6.8<\/td>\n<td>3.4<\/td>\n<td>22.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Boyut<\/h2>\n<p>The catalog drawing labels B, D, d, L and E. The table also lists a model-specific material thickness and mating NEMA tab size. D, d and E are shared within each conductor group. All dimensions are in millimeters.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Color<\/th>\n<th>NEMA tab (mm)<\/th>\n<th>Table thickness (mm)<\/th>\n<th>B (mm)<\/th>\n<th>D (mm)<\/th>\n<th>d (mm)<\/th>\n<th>L (mm)<\/th>\n<th>E (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>FDH 1.25-110(5)<\/td>\n<td>Red<\/td>\n<td>0.5 \u00d7 2.8<\/td>\n<td>0.3<\/td>\n<td>3.3<\/td>\n<td>4.8<\/td>\n<td>1.7<\/td>\n<td>27.3<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 1.25-110(8)<\/td>\n<td>Red<\/td>\n<td>0.8 \u00d7 2.8<\/td>\n<td>0.3<\/td>\n<td>3.3<\/td>\n<td>4.8<\/td>\n<td>1.7<\/td>\n<td>27.3<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 1.25-187(5)<\/td>\n<td>Red<\/td>\n<td>0.5 \u00d7 4.75<\/td>\n<td>0.35<\/td>\n<td>5.0<\/td>\n<td>4.8<\/td>\n<td>1.7<\/td>\n<td>27.8<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 1.25-187(8)<\/td>\n<td>Red<\/td>\n<td>0.8 \u00d7 4.75<\/td>\n<td>0.35<\/td>\n<td>5.0<\/td>\n<td>4.8<\/td>\n<td>1.7<\/td>\n<td>27.8<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 1.25-205<\/td>\n<td>Red<\/td>\n<td>0.5 \u00d7 5.2<\/td>\n<td>0.35<\/td>\n<td>5.7<\/td>\n<td>4.8<\/td>\n<td>1.7<\/td>\n<td>27.8<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 1.25-250<\/td>\n<td>Red<\/td>\n<td>0.8 \u00d7 6.35<\/td>\n<td>0.4<\/td>\n<td>6.6<\/td>\n<td>4.8<\/td>\n<td>1.7<\/td>\n<td>28.6<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 1.25-312<\/td>\n<td>Red<\/td>\n<td>0.8 \u00d7 8.0<\/td>\n<td>0.4<\/td>\n<td>8.2<\/td>\n<td>4.8<\/td>\n<td>1.7<\/td>\n<td>31.8<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 2-110(5)<\/td>\n<td>Blue<\/td>\n<td>0.5 \u00d7 2.8<\/td>\n<td>0.3<\/td>\n<td>3.3<\/td>\n<td>5.8<\/td>\n<td>2.3<\/td>\n<td>27.3<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 2-110(8)<\/td>\n<td>Blue<\/td>\n<td>0.8 \u00d7 2.8<\/td>\n<td>0.3<\/td>\n<td>3.3<\/td>\n<td>5.8<\/td>\n<td>2.3<\/td>\n<td>27.3<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 2-187(5)<\/td>\n<td>Blue<\/td>\n<td>0.5 \u00d7 4.75<\/td>\n<td>0.35<\/td>\n<td>5.0<\/td>\n<td>5.8<\/td>\n<td>2.3<\/td>\n<td>27.8<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 2-187(8)<\/td>\n<td>Blue<\/td>\n<td>0.8 \u00d7 4.75<\/td>\n<td>0.35<\/td>\n<td>5.0<\/td>\n<td>5.8<\/td>\n<td>2.3<\/td>\n<td>27.8<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 2-205<\/td>\n<td>Blue<\/td>\n<td>0.5 \u00d7 5.2<\/td>\n<td>0.35<\/td>\n<td>5.7<\/td>\n<td>5.8<\/td>\n<td>2.3<\/td>\n<td>27.8<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 2-250<\/td>\n<td>Blue<\/td>\n<td>0.8 \u00d7 6.35<\/td>\n<td>0.4<\/td>\n<td>6.6<\/td>\n<td>5.8<\/td>\n<td>2.3<\/td>\n<td>27.8<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 2-312<\/td>\n<td>Blue<\/td>\n<td>0.8 \u00d7 8.0<\/td>\n<td>0.4<\/td>\n<td>8.2<\/td>\n<td>5.8<\/td>\n<td>2.3<\/td>\n<td>32.5<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 2-375<\/td>\n<td>Blue<\/td>\n<td>1.2 \u00d7 9.4<\/td>\n<td>0.5<\/td>\n<td>9.9<\/td>\n<td>5.8<\/td>\n<td>2.3<\/td>\n<td>36.4<\/td>\n<td>19.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 5.5-110\u00d75<\/td>\n<td>Yellow<\/td>\n<td>0.5 \u00d7 2.8<\/td>\n<td>0.35<\/td>\n<td>3.3<\/td>\n<td>6.8<\/td>\n<td>3.4<\/td>\n<td>29.8<\/td>\n<td>22.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 5.5-110\u00d78<\/td>\n<td>Yellow<\/td>\n<td>0.8 \u00d7 2.8<\/td>\n<td>0.35<\/td>\n<td>3.3<\/td>\n<td>6.8<\/td>\n<td>3.4<\/td>\n<td>29.8<\/td>\n<td>22.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 5.5-187\u00d75<\/td>\n<td>Yellow<\/td>\n<td>0.5 \u00d7 4.75<\/td>\n<td>0.4<\/td>\n<td>5.0<\/td>\n<td>6.8<\/td>\n<td>3.4<\/td>\n<td>30.8<\/td>\n<td>22.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 5.5-187\u00d78<\/td>\n<td>Yellow<\/td>\n<td>0.8 \u00d7 4.75<\/td>\n<td>0.4<\/td>\n<td>5.0<\/td>\n<td>6.8<\/td>\n<td>3.4<\/td>\n<td>30.8<\/td>\n<td>22.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 5.5-250<\/td>\n<td>Yellow<\/td>\n<td>0.8 \u00d7 6.35<\/td>\n<td>0.4<\/td>\n<td>6.6<\/td>\n<td>6.8<\/td>\n<td>3.4<\/td>\n<td>32.2<\/td>\n<td>22.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 5.5-312<\/td>\n<td>Yellow<\/td>\n<td>0.8 \u00d7 8.0<\/td>\n<td>0.5<\/td>\n<td>8.2<\/td>\n<td>6.8<\/td>\n<td>3.4<\/td>\n<td>36.1<\/td>\n<td>22.0<\/td>\n<\/tr>\n<tr>\n<td>FDH 5.5-375<\/td>\n<td>Yellow<\/td>\n<td>1.2 \u00d7 9.4<\/td>\n<td>0.5<\/td>\n<td>9.9<\/td>\n<td>6.8<\/td>\n<td>3.4<\/td>\n<td>38.4<\/td>\n<td>22.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Se\u00e7im K\u0131lavuzu<\/h2>\n<p>Match the conductor section and NEMA tab size first, then check thickness and B\/D\/d\/L\/E dimensions against the mating connection and available space. Include the complete FDH model code and required quantity in an inquiry.<\/p>\n<h2>Boyut<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/09\/fdh-heat-shrinkable-female-terminals-dimension.webp\" alt=\"FDH Heat Shrinkable Female Terminals dimension drawing\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>FDH heat shrinkable female terminals are copper receptacles with a heat-shrink sleeve for mating with flat tabs. The 22 listed models cover 0.5\u20136 mm\u00b2 conductors.<\/p>\n<ul>\n<li>Choose red, blue or yellow by conductor section.<\/li>\n<li>Compare NEMA tab size, table thickness and B\/D\/d\/L\/E dimensions by model.<\/li>\n<li>Source operating range: \u221255 to +125 \u00b0C; shrink begins at 80 \u00b0C.<\/li>\n<\/ul>","protected":false},"featured_media":2053,"template":"","meta":[],"product_brand":[],"product_cat":[110],"product_tag":[],"class_list":["post-858","product","type-product","status-publish","has-post-thumbnail","product_cat-heat-shrink-crimp-terminals","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/858","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/2053"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=858"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=858"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=858"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=858"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}