{"id":939,"date":"2026-09-29T17:55:06","date_gmt":"2026-09-29T17:55:06","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=939"},"modified":"2026-09-29T17:55:12","modified_gmt":"2026-09-29T17:55:12","slug":"vo-bh-brass-hose-connectors","status":"publish","type":"product","link":"https:\/\/yocl.com\/tr\/product\/vo-bh-brass-hose-connectors\/","title":{"rendered":"VO-BH Brass Hose Connectors"},"content":{"rendered":"<h2>Genel Bak\u0131\u015f<\/h2>\n<p>VO-BH brass hose connectors are a separate model series in the supplied brass hose connector catalogue. Metric and PG versions are listed by thread size and nominal tubing inner diameter. The source gives B, C, D, SW1 and SW2 dimensions for each model, which should be checked against the tubing and installation space.<\/p>\n<p>The shared overview identifies nickel-plated brass external metal, NBR rubber and PA6 internal components, and a brass ferrule. It states IP65 protection for this connector family.<\/p>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li><strong>Two thread systems:<\/strong> Metric and PG versions are available in the supplied model tables.<\/li>\n<li><strong>Nickel-plated brass exterior:<\/strong> The source specifies the material and finish.<\/li>\n<li><strong>Tubing-size selection:<\/strong> Each model states the nominal tubing inner diameter it fits.<\/li>\n<li><strong>Installation dimensions:<\/strong> B, C, D and two spanner sizes (SW1\/SW2) are provided by code.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>Teknik \u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Seri<\/td>\n<td>VO-BH<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Brass hose connector<\/td>\n<\/tr>\n<tr>\n<td>Listed thread types<\/td>\n<td>Metric and PG<\/td>\n<\/tr>\n<tr>\n<td>External metal<\/td>\n<td>Nickel-plated brass<\/td>\n<\/tr>\n<tr>\n<td>Internal components<\/td>\n<td>NBR rubber and PA6<\/td>\n<\/tr>\n<tr>\n<td>Ferrule<\/td>\n<td>Brass<\/td>\n<\/tr>\n<tr>\n<td>Protection rating<\/td>\n<td>IP65 (source catalogue statement)<\/td>\n<\/tr>\n<tr>\n<td>Static temperature range<\/td>\n<td>\u221240 to +100 \u00b0C; short exposure to +120 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Dynamic temperature range<\/td>\n<td>\u221220 to +80 \u00b0C; short exposure to +100 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Boyut<\/h2>\n<p>The catalogue&#8217;s \u00d8B, C, D, SW1 and SW2 values are in mm. The source does not define B, C or D with a separate labelled drawing, so their original dimension letters are retained. Tubing size means <strong>nominal inner diameter<\/strong>.<\/p>\n<h3>Metric thread models<\/h3>\n<table>\n<thead>\n<tr>\n<th>Catalogue code<\/th>\n<th>Thread<\/th>\n<th>Tubing nominal I.D. (mm)<\/th>\n<th>\u00d8B (mm)<\/th>\n<th>C (mm)<\/th>\n<th>D (mm)<\/th>\n<th>SW1 (mm)<\/th>\n<th>SW2 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>VO-M10-BH<\/td>\n<td>M10\u00d71<\/td>\n<td>\u00d86<\/td>\n<td>19<\/td>\n<td>10<\/td>\n<td>31<\/td>\n<td>15<\/td>\n<td>17<\/td>\n<\/tr>\n<tr>\n<td>VO-M12-BH<\/td>\n<td>M12\u00d71.5<\/td>\n<td>\u00d86<\/td>\n<td>23<\/td>\n<td>10<\/td>\n<td>33<\/td>\n<td>19<\/td>\n<td>21<\/td>\n<\/tr>\n<tr>\n<td>VO-M16-BH<\/td>\n<td>M16\u00d71.5<\/td>\n<td>\u00d88<\/td>\n<td>27<\/td>\n<td>10<\/td>\n<td>33<\/td>\n<td>23<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td>VO-M20-BH<\/td>\n<td>M20\u00d71.5<\/td>\n<td>\u00d812<\/td>\n<td>31<\/td>\n<td>10<\/td>\n<td>33<\/td>\n<td>27<\/td>\n<td>29<\/td>\n<\/tr>\n<tr>\n<td>VO-M25-BH<\/td>\n<td>M25\u00d71.5<\/td>\n<td>\u00d815<\/td>\n<td>39<\/td>\n<td>11<\/td>\n<td>41<\/td>\n<td>34<\/td>\n<td>36<\/td>\n<\/tr>\n<tr>\n<td>VO-M32-BH<\/td>\n<td>M32\u00d71.5<\/td>\n<td>\u00d820<\/td>\n<td>48<\/td>\n<td>13<\/td>\n<td>43<\/td>\n<td>43<\/td>\n<td>45<\/td>\n<\/tr>\n<tr>\n<td>VO-M40-BH<\/td>\n<td>M40\u00d71.5<\/td>\n<td>\u00d832<\/td>\n<td>57<\/td>\n<td>13<\/td>\n<td>43<\/td>\n<td>52<\/td>\n<td>54<\/td>\n<\/tr>\n<tr>\n<td>VO-M50-BH<\/td>\n<td>M50\u00d71.5<\/td>\n<td>\u00d838<\/td>\n<td>70<\/td>\n<td>14<\/td>\n<td>49<\/td>\n<td>63<\/td>\n<td>66<\/td>\n<\/tr>\n<tr>\n<td>VO-M63-BH<\/td>\n<td>M63\u00d71.5<\/td>\n<td>\u00d851<\/td>\n<td>70<\/td>\n<td>14<\/td>\n<td>49<\/td>\n<td>63<\/td>\n<td>66<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>PG thread models<\/h3>\n<table>\n<thead>\n<tr>\n<th>Catalogue code<\/th>\n<th>Thread<\/th>\n<th>Tubing nominal I.D. (mm)<\/th>\n<th>\u00d8B (mm)<\/th>\n<th>C (mm)<\/th>\n<th>D (mm)<\/th>\n<th>SW1 (mm)<\/th>\n<th>SW2 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>VO-PG7-BH<\/td>\n<td>PG7<\/td>\n<td>\u00d86<\/td>\n<td>19<\/td>\n<td>7<\/td>\n<td>28<\/td>\n<td>15<\/td>\n<td>17<\/td>\n<\/tr>\n<tr>\n<td>VO-PG9-BH<\/td>\n<td>PG9<\/td>\n<td>\u00d86<\/td>\n<td>23<\/td>\n<td>7<\/td>\n<td>30<\/td>\n<td>19<\/td>\n<td>21<\/td>\n<\/tr>\n<tr>\n<td>VO-PG11-BH<\/td>\n<td>PG11<\/td>\n<td>\u00d88<\/td>\n<td>27<\/td>\n<td>7<\/td>\n<td>30<\/td>\n<td>23<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td>VO-PG13-BH<\/td>\n<td>PG13.5<\/td>\n<td>\u00d812<\/td>\n<td>29<\/td>\n<td>7<\/td>\n<td>30<\/td>\n<td>25<\/td>\n<td>27<\/td>\n<\/tr>\n<tr>\n<td>VO-PG16-BH<\/td>\n<td>PG16<\/td>\n<td>\u00d815<\/td>\n<td>31<\/td>\n<td>7<\/td>\n<td>30<\/td>\n<td>27<\/td>\n<td>29<\/td>\n<\/tr>\n<tr>\n<td>VO-PG21-BH<\/td>\n<td>PG21<\/td>\n<td>\u00d820<\/td>\n<td>39<\/td>\n<td>10<\/td>\n<td>40<\/td>\n<td>34<\/td>\n<td>36<\/td>\n<\/tr>\n<tr>\n<td>VO-PG29-BH<\/td>\n<td>PG29<\/td>\n<td>\u00d825<\/td>\n<td>48<\/td>\n<td>10<\/td>\n<td>40<\/td>\n<td>43<\/td>\n<td>45<\/td>\n<\/tr>\n<tr>\n<td>VO-PG36-BH<\/td>\n<td>PG36<\/td>\n<td>\u00d832<\/td>\n<td>57<\/td>\n<td>10<\/td>\n<td>40<\/td>\n<td>52<\/td>\n<td>54<\/td>\n<\/tr>\n<tr>\n<td>VO-PG48-BH<\/td>\n<td>PG48<\/td>\n<td>\u00d838<\/td>\n<td>70<\/td>\n<td>10<\/td>\n<td>45<\/td>\n<td>63<\/td>\n<td>66<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Se\u00e7im K\u0131lavuzu<\/h2>\n<p>Use the enclosure thread size and tubing&#8217;s nominal inner diameter to narrow the model list. Compare the catalogue&#8217;s B\/C\/D values and both spanner sizes with the available space. Include the full catalogue code and quantity when requesting a quotation.<\/p>\n<h2>Boyut<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/09\/vo-bh-brass-hose-connectors-dimension.webp\" alt=\"VO-BH Brass Hose Connectors dimension drawing\"><\/p>","protected":false},"excerpt":{"rendered":"<p>VO-BH brass hose connectors offer Metric and PG thread versions for nominal hose bores shown in the catalogue. Their external metal is nickel-plated brass, with NBR and PA6 internal parts.<\/p>\n<ul>\n<li>Nine Metric and nine PG catalogue models<\/li>\n<li>Model-specific B, C, D, SW1 and SW2 dimensions<\/li>\n<li>IP65 protection rating stated in the source catalogue<\/li>\n<li>Select by thread size and nominal hose inner diameter<\/li>\n<\/ul>","protected":false},"featured_media":937,"template":"","meta":[],"product_brand":[],"product_cat":[154],"product_tag":[],"class_list":["post-939","product","type-product","status-publish","has-post-thumbnail","product_cat-conduit-hose-connectors","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product\/939","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media\/937"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/media?parent=939"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_brand?post=939"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_cat?post=939"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/tr\/wp-json\/wp\/v2\/product_tag?post=939"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}