{"id":1830,"date":"2026-10-02T17:06:19","date_gmt":"2026-10-02T17:06:19","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=1830"},"modified":"2026-10-02T17:06:25","modified_gmt":"2026-10-02T17:06:25","slug":"hsne-f-2-1-flame-retardant-ev-busbar-heat-shrink-tubing","status":"publish","type":"product","link":"https:\/\/yocl.com\/vi\/product\/hsne-f-2-1-flame-retardant-ev-busbar-heat-shrink-tubing\/","title":{"rendered":"HSNE-F 2:1 \u1ed0ng co nhi\u1ec7t ch\u1ed1ng ch\u00e1y cho thanh c\u00e1i xe \u0111i\u1ec7n"},"content":{"rendered":"<h2>T\u1ed5ng quan<\/h2>\n<p>YOCL \u0110i\u1ec7n <strong>HSNE-F 2:1 \u1ed0ng co nhi\u1ec7t ch\u1ed1ng ch\u00e1y cho thanh c\u00e1i xe \u0111i\u1ec7n<\/strong> provides electrical insulation and surface protection for new energy vehicle busbars, copper bars and electrical connections. The series is made from radiation cross-linked polyolefin with a single-wall construction.<\/p>\n<p>Its <strong>2:1 shrink ratio<\/strong> allows the tubing to recover around conductive components and connection areas. Eighteen sizes cover nominal diameters from 10\/5 mm to 50\/25 mm. HSNE-F has a <strong>VW-1 flame rating<\/strong>, an operating range of <strong>-55\u00b0C to +125\u00b0C<\/strong> and a standard <strong>orange color<\/strong>.<\/p>\n<h2>Features<\/h2>\n<ul>\n<li><strong>EV busbar insulation:<\/strong> Suits copper bars, laminated busbars and battery electrical connections.<\/li>\n<li><strong>2:1 single-wall construction:<\/strong> Forms a close-fitting insulating cover around the component.<\/li>\n<li><strong>VW-1 flame performance:<\/strong> Specified with ASTM D2671 as the test method.<\/li>\n<li><strong>Defined electrical properties:<\/strong> Withstand-voltage, breakdown-strength and resistivity specifications are listed below.<\/li>\n<li><strong>Standard orange color:<\/strong> Supports visual identification in vehicle electrical systems; custom colors are available.<\/li>\n<li><strong>Eighteen size options:<\/strong> Supplied diameters, recovered walls, packing lengths and application ranges are listed by size.<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Brand<\/td>\n<td>YOCL \u0110i\u1ec7n<\/td>\n<\/tr>\n<tr>\n<td>Series<\/td>\n<td>HSNE-F<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Flame-retardant single-wall heat shrink tubing<\/td>\n<\/tr>\n<tr>\n<td>Primary application<\/td>\n<td>New energy vehicle busbars and electrical connections<\/td>\n<\/tr>\n<tr>\n<td>Material<\/td>\n<td>Radiation cross-linked polyolefin<\/td>\n<\/tr>\n<tr>\n<td>C\u1ea5u t\u1ea1o<\/td>\n<td>Single wall<\/td>\n<\/tr>\n<tr>\n<td>Shrink ratio<\/td>\n<td>2:1<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>-55\u00b0C to +125\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Initial shrink temperature<\/td>\n<td>\u226585\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Full shrink temperature<\/td>\n<td>\u2265125\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Standard color<\/td>\n<td>Orange<\/td>\n<\/tr>\n<tr>\n<td>Custom colors<\/td>\n<td>Available<\/td>\n<\/tr>\n<tr>\n<td>Environmental standard<\/td>\n<td>RoHS<\/td>\n<\/tr>\n<tr>\n<td>Nominal size range<\/td>\n<td>10\/5 mm to 50\/25 mm<\/td>\n<\/tr>\n<tr>\n<td>Standard packing<\/td>\n<td>100 m, 50 m or 25 m, depending on size<\/td>\n<\/tr>\n<tr>\n<td>Number of listed sizes<\/td>\n<td>18<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Mechanical and Flame Performance<\/h3>\n<table>\n<thead>\n<tr>\n<th>Property<\/th>\n<th>Specification<\/th>\n<th>Test method or condition<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tensile strength<\/td>\n<td>\u226510.4 MPa<\/td>\n<td>ASTM D2671<\/td>\n<\/tr>\n<tr>\n<td>Elongation at break<\/td>\n<td>\u2265200%<\/td>\n<td>ASTM D2671<\/td>\n<\/tr>\n<tr>\n<td>Tensile strength after aging<\/td>\n<td>\u22657.3 MPa<\/td>\n<td>158\u00b0C for 168 hours<\/td>\n<\/tr>\n<tr>\n<td>Elongation after aging<\/td>\n<td>\u2265100%<\/td>\n<td>158\u00b0C for 168 hours<\/td>\n<\/tr>\n<tr>\n<td>Axial change<\/td>\n<td>-5% to +5%<\/td>\n<td>ASTM D2671<\/td>\n<\/tr>\n<tr>\n<td>Flame retardancy<\/td>\n<td>VW-1<\/td>\n<td>ASTM D2671<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The 158\u00b0C exposure is an aging test condition. The stated operating temperature range is -55\u00b0C to +125\u00b0C.<\/p>\n<h3>Electrical Performance<\/h3>\n<table>\n<thead>\n<tr>\n<th>Property<\/th>\n<th>Specification<\/th>\n<th>Test method<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Withstand voltage (600 V)<\/td>\n<td>2500 V for 1 minute; no breakdown<\/td>\n<td>UL224<\/td>\n<\/tr>\n<tr>\n<td>Breakdown strength<\/td>\n<td>\u226515 kV\/mm<\/td>\n<td>ASTM D149<\/td>\n<\/tr>\n<tr>\n<td>Volume resistivity<\/td>\n<td>\u226510\u00b9\u2074 \u03a9\u00b7cm<\/td>\n<td>IEC 60093<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimension<\/h2>\n<table>\n<thead>\n<tr>\n<th>Nominal size (mm)<\/th>\n<th>Supplied I.D. (mm)<\/th>\n<th>Max. I.D. after recovery (mm)<\/th>\n<th>Wall thickness after recovery (mm)<\/th>\n<th>Standard packing (m)<\/th>\n<th>Application range (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>10\/5<\/td>\n<td>10.5 \u00b1 0.30<\/td>\n<td>\u22645.00<\/td>\n<td>0.56 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>5.3\u201310.1<\/td>\n<\/tr>\n<tr>\n<td>11\/5.5<\/td>\n<td>11.5 \u00b1 0.30<\/td>\n<td>\u22645.50<\/td>\n<td>0.56 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>5.8\u201311.1<\/td>\n<\/tr>\n<tr>\n<td>12\/6<\/td>\n<td>12.5 \u00b1 0.30<\/td>\n<td>\u22646.00<\/td>\n<td>0.56 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>6.3\u201312.1<\/td>\n<\/tr>\n<tr>\n<td>13\/6.5<\/td>\n<td>13.5 \u00b1 0.30<\/td>\n<td>\u22646.50<\/td>\n<td>0.70 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>6.8\u201313.1<\/td>\n<\/tr>\n<tr>\n<td>14\/7<\/td>\n<td>14.5 \u00b1 0.30<\/td>\n<td>\u22647.00<\/td>\n<td>0.70 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>7.3\u201314.1<\/td>\n<\/tr>\n<tr>\n<td>15\/7.5<\/td>\n<td>15.5 \u00b1 0.40<\/td>\n<td>\u22647.50<\/td>\n<td>0.70 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>7.8\u201315.1<\/td>\n<\/tr>\n<tr>\n<td>16\/8<\/td>\n<td>16.5 \u00b1 0.40<\/td>\n<td>\u22648.00<\/td>\n<td>0.70 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>8.3\u201316.1<\/td>\n<\/tr>\n<tr>\n<td>17\/8.5<\/td>\n<td>17.5 \u00b1 0.40<\/td>\n<td>\u22648.50<\/td>\n<td>0.70 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>8.8\u201317.1<\/td>\n<\/tr>\n<tr>\n<td>18\/9<\/td>\n<td>19.0 \u00b1 0.50<\/td>\n<td>\u22649.00<\/td>\n<td>0.70 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>9.3\u201318.1<\/td>\n<\/tr>\n<tr>\n<td>20\/10<\/td>\n<td>22.0 \u00b1 0.50<\/td>\n<td>\u226410.00<\/td>\n<td>0.80 \u00b1 0.15<\/td>\n<td>100<\/td>\n<td>10.5\u201321.0<\/td>\n<\/tr>\n<tr>\n<td>22\/11<\/td>\n<td>24.0 \u00b1 0.50<\/td>\n<td>\u226411.00<\/td>\n<td>0.80 \u00b1 0.15<\/td>\n<td>100<\/td>\n<td>11.5\u201323.0<\/td>\n<\/tr>\n<tr>\n<td>25\/12.5<\/td>\n<td>26.0 \u00b1 0.50<\/td>\n<td>\u226412.50<\/td>\n<td>0.90 \u00b1 0.15<\/td>\n<td>50<\/td>\n<td>13.0\u201325.0<\/td>\n<\/tr>\n<tr>\n<td>28\/14<\/td>\n<td>29.0 \u00b1 0.50<\/td>\n<td>\u226414.00<\/td>\n<td>0.90 \u00b1 0.15<\/td>\n<td>50<\/td>\n<td>14.5\u201327.0<\/td>\n<\/tr>\n<tr>\n<td>30\/15<\/td>\n<td>31.5 \u00b1 1.00<\/td>\n<td>\u226415.00<\/td>\n<td>1.00 \u00b1 0.15<\/td>\n<td>50<\/td>\n<td>17.0\u201329.0<\/td>\n<\/tr>\n<tr>\n<td>35\/17.5<\/td>\n<td>36.5 \u00b1 1.00<\/td>\n<td>\u226417.50<\/td>\n<td>1.00 \u00b1 0.15<\/td>\n<td>50<\/td>\n<td>20.0\u201330.0<\/td>\n<\/tr>\n<tr>\n<td>40\/20<\/td>\n<td>41.5 \u00b1 1.00<\/td>\n<td>\u226420.00<\/td>\n<td>1.00 \u00b1 0.15<\/td>\n<td>50<\/td>\n<td>22.0\u201335.0<\/td>\n<\/tr>\n<tr>\n<td>45\/22.5<\/td>\n<td>46.5 \u00b1 1.50<\/td>\n<td>\u226422.50<\/td>\n<td>1.00 \u00b1 0.15<\/td>\n<td>25<\/td>\n<td>30\u201345<\/td>\n<\/tr>\n<tr>\n<td>50\/25<\/td>\n<td>\u226550<\/td>\n<td>\u226425.00<\/td>\n<td>1.10 \u00b1 0.15<\/td>\n<td>25<\/td>\n<td>28\u201345<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>I.D. means internal diameter. Diameters, wall thicknesses and application ranges are in millimetres; packing lengths are in metres. The \u2264 values specify maximum recovered internal diameters. The 50\/25 mm size has a minimum supplied I.D. of 50 mm.<\/p>\n<h2>Selection Guide<\/h2>\n<p>Use the application range for the selected size together with its supplied I.D., maximum recovered I.D. and recovered wall thickness. For example, the 20\/10 mm option has a supplied I.D. of 22.0 \u00b1 0.50 mm, a maximum recovered I.D. of 10.00 mm and a recovered wall thickness of 0.80 \u00b1 0.15 mm. Its application range is 10.5\u201321.0 mm.<\/p>\n<p>Check fit over the busbar, connection or component before choosing a size. Review the packing length for that row: 100 m for sizes 10\/5 through 22\/11, 50 m for 25\/12.5 through 40\/20, and 25 m for 45\/22.5 and 50\/25.<\/p>\n<p>Specify the required color and quantity with the selected size. Orange is the standard color; other colors can be requested for project requirements.<\/p>\n<h2>\u1ee8ng d\u1ee5ng<\/h2>\n<ul>\n<li>EV and hybrid vehicle battery systems.<\/li>\n<li>Copper and laminated busbar insulation.<\/li>\n<li>Battery electrical connections and conductive components.<\/li>\n<li>Solder-joint protection against corrosion.<\/li>\n<li>Electrical connection and component covering.<\/li>\n<\/ul>\n<h2>Installation Notes<\/h2>\n<ol>\n<li>Measure the busbar, conductor or component requiring insulation.<\/li>\n<li>Select HSNE-F tubing using the application range and dimensional table.<\/li>\n<li>Cut the tubing to the required length and slide it into position.<\/li>\n<li>Apply controlled heat evenly around the tubing until it has uniformly recovered.<\/li>\n<li>Remove the heat source and allow the tubing to cool.<\/li>\n<li>Inspect the recovered tubing for complete and uniform coverage.<\/li>\n<\/ol>\n<h2>Ordering Information<\/h2>\n<p>Specify <strong>HSNE-F<\/strong>, the selected nominal size, required color and quantity when making an enquiry to YOCL Electric. Standard packing is <strong>100 m, 50 m or 25 m<\/strong> according to the size table.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL Electric HSNE-F provides flame-retardant single-wall insulation for EV busbars, copper bars and electrical connections.<\/p>\n<ul>\n<li>Radiation cross-linked polyolefin with a 2:1 shrink ratio.<\/li>\n<li>VW-1 flame rating; operating range -55\u00b0C to +125\u00b0C.<\/li>\n<li>Initial shrink temperature \u226585\u00b0C; full shrink temperature \u2265125\u00b0C.<\/li>\n<li>Eighteen sizes from 10\/5 mm to 50\/25 mm, with packing lengths specified by size.<\/li>\n<li>Standard orange color; custom colors available.<\/li>\n<\/ul>","protected":false},"featured_media":1829,"template":"","meta":[],"product_brand":[],"product_cat":[139],"product_tag":[],"class_list":["post-1830","product","type-product","status-publish","has-post-thumbnail","product_cat-single-wall-heat-shrink-tubing","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product\/1830","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/media\/1829"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/media?parent=1830"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_brand?post=1830"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_cat?post=1830"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_tag?post=1830"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}