{"id":2846,"date":"2026-10-07T13:33:13","date_gmt":"2026-10-07T13:33:13","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2846"},"modified":"2026-10-07T13:35:45","modified_gmt":"2026-10-07T13:35:45","slug":"ip44-industrial-appliance-inlets","status":"publish","type":"product","link":"https:\/\/yocl.com\/vi\/product\/ip44-industrial-appliance-inlets\/","title":{"rendered":"IP44 Ph\u00edch c\u1eafm c\u00f4ng nghi\u1ec7p cho thi\u1ebft b\u1ecb"},"content":{"rendered":"<h2>T\u1ed5ng quan<\/h2>\n<p>YOCL ELECTRIC IP44 \u0111\u1ea7u n\u1ed1i thi\u1ebft b\u1ecb c\u00f4ng nghi\u1ec7p d\u1ea1ng \u0111\u1ef1c cung c\u1ea5p k\u1ebft n\u1ed1i ngu\u1ed3n tr\u00ean m\u00e1y m\u00f3c, thi\u1ebft b\u1ecb ph\u00e2n ph\u1ed1i v\u00e0 v\u1ecf thi\u1ebft b\u1ecb. D\u00f2ng s\u1ea3n ph\u1ea9m bao g\u1ed3m c\u00e1c phi\u00ean b\u1ea3n 16 A v\u00e0 32 A v\u1edbi c\u00e1c c\u1ea5u h\u00ecnh 2P+E, 3P+E v\u00e0 3P+N+E. \u0110\u1ea7u n\u1ed1i b\u1ea3ng \u0111i\u1ec1u khi\u1ec3n th\u1eb3ng v\u00e0 thi\u1ebft k\u1ebf \u0111\u1ea7u n\u1ed1i l\u1eafp n\u1ed5i c\u00f3 v\u1ecf b\u1ecdc \u0111\u01b0\u1ee3c nh\u00f3m \u1edf \u0111\u00e2y \u0111\u1ec3 c\u00f3 th\u1ec3 ch\u1ecdn giao di\u1ec7n ngu\u1ed3n c\u00f9ng v\u1edbi c\u00e1ch l\u1eafp \u0111\u1eb7t c\u1ee7a n\u00f3. \u0110\u1ea7u n\u1ed1i c\u00e1p d\u1ea1ng c\u00e1i t\u01b0\u01a1ng \u1ee9ng cung c\u1ea5p k\u1ebft n\u1ed1i c\u00e1p c\u00f3 th\u1ec3 th\u00e1o r\u1eddi.<\/p>\n<h2>T\u00ednh n\u0103ng<\/h2>\n<ul>\n<li>C\u00e1c phi\u00ean b\u1ea3n IP44 cho c\u00e1c k\u1ebft n\u1ed1i c\u00f4ng nghi\u1ec7p ch\u1ed1ng b\u1eafn t\u00f3e.<\/li>\n<li>Thi\u1ebft k\u1ebf l\u1eafp b\u1ea3ng \u0111i\u1ec1u khi\u1ec3n th\u1eb3ng trong v\u1ecf ti\u00eau chu\u1ea9n v\u00e0 K, c\u1ed9ng v\u1edbi thi\u1ebft k\u1ebf l\u1eafp n\u1ed5i c\u00f3 m\u1eb7t \u0111\u1ea7u n\u1ed1i g\u00f3c.<\/li>\n<li>C\u00e1c l\u1ef1a ch\u1ecdn 16 A v\u00e0 32 A v\u1edbi ph\u1ea1m vi d\u00e2y d\u1eabn \u0111\u01b0\u1ee3c n\u00eau cho m\u1ed7i m\u1eabu.<\/li>\n<li>V\u1ecb tr\u00ed ti\u1ebfp \u0111i\u1ec3m n\u1ed1i \u0111\u1ea5t 6h tr\u00ean c\u00e1c m\u1eabu \u0111\u01b0\u1ee3c li\u1ec7t k\u00ea.<\/li>\n<li>V\u1ecf ti\u1ebfp \u0111i\u1ec3m m\u00e0u xanh lam v\u00e0 \u0111\u1ecf ph\u00e2n bi\u1ec7t c\u00e1c c\u1ea5u h\u00ecnh \u0111i\u1ec7n \u0111\u01b0\u1ee3c li\u1ec7t k\u00ea.<\/li>\n<\/ul>\n<h2>Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt<\/h2>\n<table>\n<thead>\n<tr>\n<th>Tham s\u1ed1<\/th>\n<th>Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Th\u01b0\u01a1ng hi\u1ec7u<\/td>\n<td>YOCL \u0110I\u1ec6N<\/td>\n<\/tr>\n<tr>\n<td>Lo\u1ea1i s\u1ea3n ph\u1ea9m<\/td>\n<td>\u0110\u1ea7u n\u1ed1i thi\u1ebft b\u1ecb c\u00f4ng nghi\u1ec7p \/ \u0110\u1ea7u n\u1ed1i thi\u1ebft b\u1ecb \u0111\u1ef1c<\/td>\n<\/tr>\n<tr>\n<td>C\u1ea5p b\u1ea3o v\u1ec7<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td>C\u00e1c l\u1ef1a ch\u1ecdn d\u00f2ng \u0111i\u1ec7n \u0111\u1ecbnh m\u1ee9c<\/td>\n<td>16 A, 32 A<\/td>\n<\/tr>\n<tr>\n<td>C\u1ea5u h\u00ecnh ti\u1ebfp \u0111i\u1ec3m<\/td>\n<td>2P+E; 3P+E; 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>V\u1ecb tr\u00ed ti\u1ebfp x\u00fac \u0111\u1ea5t<\/td>\n<td>6h<\/td>\n<\/tr>\n<tr>\n<td>L\u1eafp \u0111\u1eb7t<\/td>\n<td>G\u1eafn tr\u00ean b\u1ea3ng \u0111i\u1ec1u khi\u1ec3n ho\u1eb7c g\u1eafn b\u1ec1 m\u1eb7t c\u00f3 v\u1ecf, t\u00f9y thu\u1ed9c v\u00e0o m\u1eabu m\u00e3<\/td>\n<\/tr>\n<tr>\n<td>Giao di\u1ec7n c\u00e1p gh\u00e9p n\u1ed1i<\/td>\n<td>\u0110\u1ea7u n\u1ed1i c\u00e1p c\u00f4ng nghi\u1ec7p c\u00e1i t\u01b0\u01a1ng \u1ee9ng<\/td>\n<\/tr>\n<tr>\n<td>Dung l\u01b0\u1ee3ng d\u00e2y d\u1eabn<\/td>\n<td>Theo m\u1eabu c\u1ee5 th\u1ec3; xem b\u1ea3ng ch\u1ecdn<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Ch\u1ecdn m\u1eabu<\/h2>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>L\u1eafp \u0111\u1eb7t \/ v\u1ecf<\/th>\n<th>D\u00f2ng \u0111i\u1ec7n (A)<\/th>\n<th>Ti\u1ebfp \u0111i\u1ec3m<\/th>\n<th>\u0110i\u1ec7n \u00e1p<\/th>\n<th>V\u1ecb tr\u00ed n\u1ed1i \u0111\u1ea5t<\/th>\n<th>V\u1ecf ti\u1ebfp x\u00fac<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-613K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-623K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-614K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-624K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-615K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-625K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-613<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-623<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-614<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-624<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-615<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-625<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-513<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-523<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-514<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-524<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-515<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-525<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-513L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-523L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-514L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-524L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-515L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-525L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>P denotes a phase contact, N neutral and E protective earth. A dash means that no voltage is assigned in this selection table.<\/p>\n<h2>K\u00edch th\u01b0\u1edbc<\/h2>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>Lettered outline dimensions (mm)<\/th>\n<th>Fixed mounting geometry<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-613K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-623K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-614K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-624K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-615K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-625K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-613<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-623<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-614<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-624<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-615<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-625<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-513<\/td>\n<td>a=125, b=71, c=43, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-523<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-514<\/td>\n<td>a=130, b=72, c=49.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-524<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-515<\/td>\n<td>a=130, b=77, c=55.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-525<\/td>\n<td>a=143, b=83, c=63, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-513L<\/td>\n<td>a=125, b=71, c=43, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-523L<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-514L<\/td>\n<td>a=130, b=72, c=49.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-524L<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-515L<\/td>\n<td>a=130, b=77, c=55.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-525L<\/td>\n<td>a=143, b=83, c=63, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Use the lettered dimensions with the matching inlet outline. Flange geometry and housing size differ between body versions; select the complete model code when checking installation space.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension-02.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension-03.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<h2>L\u1ef1a ch\u1ecdn k\u1ebft n\u1ed1i<\/h2>\n<p>Match rated current, contact configuration, voltage and earth-contact position at both sides of the connection. Select panel or surface mounting before comparing the housing dimensions. The IP rating applies to the correctly assembled connection with its compatible mating interface; maintain the specified sealing and closure arrangement.<\/p>\n<h2>Th\u00f4ng tin \u0111\u1eb7t h\u00e0ng<\/h2>\n<p>Send YOCL ELECTRIC the full model code, required quantity, supply voltage, contact configuration and installation arrangement. Include conductor cross-section and the mating cable connector when requesting a complete equipment power connection.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP44 \u0111\u1ea7u n\u1ed1i thi\u1ebft b\u1ecb c\u00f4ng nghi\u1ec7p d\u1ea1ng \u0111\u1ef1c trong c\u00e1c phi\u00ean b\u1ea3n 16 A v\u00e0 32 A. Ch\u1ecdn ti\u1ebfp \u0111i\u1ec3m 2P+E, 3P+E ho\u1eb7c 3P+N+E, ki\u1ec3u l\u1eafp b\u1ea3ng \u0111i\u1ec1u khi\u1ec3n ho\u1eb7c l\u1eafp n\u1ed5i v\u00e0 dung l\u01b0\u1ee3ng d\u00e2y d\u1eabn t\u01b0\u01a1ng \u1ee9ng t\u1eeb b\u1ea3ng m\u1eabu.<\/p>","protected":false},"featured_media":2845,"template":"","meta":[],"product_brand":[],"product_cat":[53],"product_tag":[],"class_list":["post-2846","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-plugs","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product\/2846","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/media\/2845"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/media?parent=2846"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_brand?post=2846"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_cat?post=2846"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_tag?post=2846"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}