{"id":2862,"date":"2026-10-07T14:05:06","date_gmt":"2026-10-07T14:05:06","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2862"},"modified":"2026-10-07T14:05:16","modified_gmt":"2026-10-07T14:05:16","slug":"ip44-industrial-plugs","status":"publish","type":"product","link":"https:\/\/yocl.com\/vi\/product\/ip44-industrial-plugs\/","title":{"rendered":"IP44 Ph\u00edch c\u1eafm c\u00f4ng nghi\u1ec7p"},"content":{"rendered":"<h2>T\u1ed5ng quan<\/h2>\n<p>YOCL ELECTRIC IP44 ph\u00edch c\u1eafm c\u00f4ng nghi\u1ec7p l\u00e0 ph\u00edch c\u1eafm c\u00e1p \u0111\u1ef1c cho k\u1ebft n\u1ed1i c\u00e1p c\u00f4ng nghi\u1ec7p. D\u00f2ng s\u1ea3n ph\u1ea9m n\u00e0y t\u1eadp h\u1ee3p c\u00e1c m\u1eabu 16 A v\u00e0 32 A th\u1ef1c t\u1ebf \u0111\u01b0\u1ee3c li\u1ec7t k\u00ea d\u01b0\u1edbi \u0111\u00e2y, v\u1edbi c\u00e1c c\u1ea5u h\u00ecnh ti\u1ebfp \u0111i\u1ec3m 2P+E, 3P+E v\u00e0 3P+N+E. M\u1ed7i m\u1eabu c\u00f3 \u0111i\u1ec7n \u00e1p, v\u1ecb tr\u00ed \u0111\u1ed3ng h\u1ed3 ti\u1ebfp \u0111i\u1ec3m n\u1ed1i \u0111\u1ea5t v\u00e0 thi\u1ebft k\u1ebf v\u1ecf ri\u00eang.<\/p>\n<p>M\u1eb7t tr\u01b0\u1edbc c\u00f3 c\u00e1c ch\u00e2n \u0111\u1ef1c nh\u00f4 ra v\u00e0 m\u1eb7t sau ch\u1ea5p nh\u1eadn c\u00e1p. C\u00e1c phi\u00ean b\u1ea3n H-design, K-design v\u00e0 th\u00e2n sau m\u00e0u tr\u1eafng cung c\u1ea5p c\u00e1c v\u1ecf ri\u00eang bi\u1ec7t trong m\u1ed9t h\u1ecd s\u1ea3n ph\u1ea9m. C\u00e1c phi\u00ean b\u1ea3n 9h \u0111\u1eb7c bi\u1ec7t \u0111\u01b0\u1ee3c li\u1ec7t k\u00ea ri\u00eang v\u1edbi c\u00e1c m\u1eabu 4h v\u00e0 6h th\u00f4ng th\u01b0\u1eddng.<\/p>\n<h2>T\u00ednh n\u0103ng<\/h2>\n<ul>\n<li>IP44 \u0111\u1ecbnh m\u1ee9c b\u1ea3o v\u1ec7 cho c\u00e1c m\u1eabu \u0111\u01b0\u1ee3c li\u1ec7t k\u00ea.<\/li>\n<li>Ti\u1ebfp \u0111i\u1ec3m \u0111\u1ef1c v\u1edbi l\u1eafp c\u00e1p thay v\u00ec l\u1eafp b\u1ea3ng \u0111i\u1ec1u khi\u1ec3n.<\/li>\n<li>C\u00e1c l\u1ef1a ch\u1ecdn d\u00f2ng \u0111i\u1ec7n \u0111\u1ecbnh m\u1ee9c: 16 A v\u00e0 32 A; c\u00e1c k\u1ebft h\u1ee3p th\u1ef1c t\u1ebf \u0111\u01b0\u1ee3c x\u00e1c \u0111\u1ecbnh b\u1edfi b\u1ea3ng m\u1eabu.<\/li>\n<li>C\u00e1c phi\u00ean b\u1ea3n 2P+E, 3P+E v\u00e0 3P+N+E \u0111\u01b0\u1ee3c x\u00e1c \u0111\u1ecbnh ri\u00eang l\u1ebb.<\/li>\n<li>C\u00e1c b\u1ed1 c\u1ee5c ti\u1ebfp x\u00fac n\u1ed1i \u0111\u1ea5t: 4h, 6h v\u00e0 c\u00e1c 9h \u0111\u01b0\u1ee3c ch\u1ecdn, theo m\u1eabu \u0111\u01b0\u1ee3c \u0111\u1eb7t t\u00ean.<\/li>\n<li>C\u00e1c nh\u00f3m v\u1ecf ri\u00eang bi\u1ec7t b\u1ea3o to\u00e0n dung l\u01b0\u1ee3ng d\u00e2y d\u1eabn v\u00e0 d\u1eef li\u1ec7u k\u00edch th\u01b0\u1edbc c\u1ee7a t\u1eebng m\u1eabu.<\/li>\n<\/ul>\n<h2>Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt<\/h2>\n<table>\n<thead>\n<tr>\n<th>Tham s\u1ed1<\/th>\n<th>Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Th\u01b0\u01a1ng hi\u1ec7u<\/td>\n<td>YOCL \u0110I\u1ec6N<\/td>\n<\/tr>\n<tr>\n<td>Lo\u1ea1i s\u1ea3n ph\u1ea9m<\/td>\n<td>Ph\u00edch c\u1eafm c\u00e1p \u0111\u1ef1c<\/td>\n<\/tr>\n<tr>\n<td>L\u1eafp \u0111\u1eb7t<\/td>\n<td>G\u1eafn tr\u00ean c\u00e1p<\/td>\n<\/tr>\n<tr>\n<td>C\u1ea5p b\u1ea3o v\u1ec7<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td>D\u00f2ng \u0111i\u1ec7n \u0111\u1ecbnh m\u1ee9c<\/td>\n<td>16 A v\u00e0 32 A<\/td>\n<\/tr>\n<tr>\n<td>C\u1ea5u h\u00ecnh ti\u1ebfp \u0111i\u1ec3m<\/td>\n<td>2P+E (3 ti\u1ebfp \u0111i\u1ec3m); 3P+E (4 ti\u1ebfp \u0111i\u1ec3m); 3P+N+E (5 ti\u1ebfp \u0111i\u1ec3m)<\/td>\n<\/tr>\n<tr>\n<td>V\u1ecb tr\u00ed ti\u1ebfp x\u00fac \u0111\u1ea5t<\/td>\n<td>4h, 6h v\u00e0 9h \u0111\u00e3 ch\u1ecdn<\/td>\n<\/tr>\n<tr>\n<td>C\u1ea5u h\u00ecnh \u0111i\u1ec7n \u00e1p<\/td>\n<td>Xem c\u00e1c h\u00e0ng m\u1eabu ri\u00eang l\u1ebb; x\u1ebfp h\u1ea1ng n\u0103m ti\u1ebfp \u0111i\u1ec3m \u0111\u00e3 gh\u00e9p \u0111\u00f4i \u0111\u01b0\u1ee3c gi\u1eef nguy\u00ean nh\u01b0 \u0111\u00e3 li\u1ec7t k\u00ea.<\/td>\n<\/tr>\n<tr>\n<td>Kh\u1ea3 n\u0103ng ch\u1ecbu t\u1ea3i c\u1ee7a d\u00e2y d\u1eabn<\/td>\n<td>Model-specific values in mm\u00b2; see the selection tables.<\/td>\n<\/tr>\n<tr>\n<td>Housing designs<\/td>\n<td>See the separate model groups below.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Thi\u1ebft k\u1ebf v\u1ecf H \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>Printed reference<\/th>\n<th>D\u00f2ng \u0111i\u1ec7n (A)<\/th>\n<th>Ti\u1ebfp \u0111i\u1ec3m<\/th>\n<th>\u0110i\u1ec7n \u00e1p (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-013H-4<\/td>\n<td>248<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>V\u00e0ng<\/td>\n<\/tr>\n<tr>\n<td>NM-023H-4<\/td>\n<td>260<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>V\u00e0ng<\/td>\n<\/tr>\n<tr>\n<td>NM-013H<\/td>\n<td>248<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<\/tr>\n<tr>\n<td>NM-023H<\/td>\n<td>260<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<\/tr>\n<tr>\n<td>NM-014H<\/td>\n<td>252<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>\u0110\u1ecf<\/td>\n<\/tr>\n<tr>\n<td>NM-024H<\/td>\n<td>264<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>\u0110\u1ecf<\/td>\n<\/tr>\n<tr>\n<td>NM-015H<\/td>\n<td>NM3<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>\u0110\u1ecf<\/td>\n<\/tr>\n<tr>\n<td>NM-025H<\/td>\n<td>NM4<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>\u0110\u1ecf<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Thi\u1ebft k\u1ebf v\u1ecf K \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>D\u00f2ng \u0111i\u1ec7n (A)<\/th>\n<th>Ti\u1ebfp \u0111i\u1ec3m<\/th>\n<th>\u0110i\u1ec7n \u00e1p (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-013K-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>V\u00e0ng<\/td>\n<\/tr>\n<tr>\n<td>NM-023K-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>V\u00e0ng<\/td>\n<\/tr>\n<tr>\n<td>NM-013K<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<\/tr>\n<tr>\n<td>NM-023K<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<\/tr>\n<tr>\n<td>NM-014K<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>\u0110\u1ecf<\/td>\n<\/tr>\n<tr>\n<td>NM-024K<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>\u0110\u1ecf<\/td>\n<\/tr>\n<tr>\n<td>NM-015K<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>\u0110\u1ecf<\/td>\n<\/tr>\n<tr>\n<td>NM-025K<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>\u0110\u1ecf<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Thi\u1ebft k\u1ebf th\u00e2n sau m\u00e0u tr\u1eafng \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>D\u00f2ng \u0111i\u1ec7n (A)<\/th>\n<th>Ti\u1ebfp \u0111i\u1ec3m<\/th>\n<th>\u0110i\u1ec7n \u00e1p (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-013-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>V\u00e0ng<\/td>\n<\/tr>\n<tr>\n<td>NM-023-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>V\u00e0ng<\/td>\n<\/tr>\n<tr>\n<td>NM-013L<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<\/tr>\n<tr>\n<td>NM-023L<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<\/tr>\n<tr>\n<td>NM-013<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<\/tr>\n<tr>\n<td>NM-023<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<\/tr>\n<tr>\n<td>NM-014<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>\u0110\u1ecf<\/td>\n<\/tr>\n<tr>\n<td>NM-024<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>\u0110\u1ecf<\/td>\n<\/tr>\n<tr>\n<td>NM-015<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>\u0110\u1ecf<\/td>\n<\/tr>\n<tr>\n<td>NM-025<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>\u0110\u1ecf<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>C\u00e1c b\u1ed1 tr\u00ed ti\u1ebfp \u0111i\u1ec3m 9h \u0111\u1eb7c bi\u1ec7t \u2014 16 \/ 32 A<\/h2>\n<p>These 9h models use the particular voltage and contact layouts shown below. Their conductor capacities and dimensions are not extended from the ordinary models.<\/p>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>D\u00f2ng \u0111i\u1ec7n (A)<\/th>\n<th>Ti\u1ebfp \u0111i\u1ec3m<\/th>\n<th>\u0110i\u1ec7n \u00e1p (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-013L-9<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>380\u2013415<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>\u0110\u1ecf<\/td>\n<\/tr>\n<tr>\n<td>NM-023L-9<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>380\u2013415<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>\u0110\u1ecf<\/td>\n<\/tr>\n<tr>\n<td>NM-115L-9<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<\/tr>\n<tr>\n<td>NM-025L-9<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<\/tr>\n<tr>\n<td>NM-014L-9<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<\/tr>\n<tr>\n<td>NM-024L-9<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>K\u00edch th\u01b0\u1edbc<\/h2>\n<p>The symbols below reproduce each housing group\u2019s dimensional table in millimetres. Letter meanings differ between drawings; a repeated symbol does not define one common dimension across all groups. Match the full model code and housing group before using a drawing.<\/p>\n<h3>Thi\u1ebft k\u1ebf v\u1ecf H \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-013H-4<\/td>\n<td>a = 140; b = 116; c = 43.5; d = 38.5<\/td>\n<\/tr>\n<tr>\n<td>NM-023H-4<\/td>\n<td>a = 173; b = 144; c = 57; d = 51<\/td>\n<\/tr>\n<tr>\n<td>NM-013H<\/td>\n<td>a = 140; b = 116; c = 43.5; d = 38.5<\/td>\n<\/tr>\n<tr>\n<td>NM-023H<\/td>\n<td>a = 173; b = 144; c = 57; d = 51<\/td>\n<\/tr>\n<tr>\n<td>NM-014H<\/td>\n<td>a = 140; b = 116; c = 49.5; d = 43.8<\/td>\n<\/tr>\n<tr>\n<td>NM-024H<\/td>\n<td>a = 173; b = 144; c = 57; d = 51<\/td>\n<\/tr>\n<tr>\n<td>NM-015H<\/td>\n<td>a = 140; b = 121; c = 56; d = 50<\/td>\n<\/tr>\n<tr>\n<td>NM-025H<\/td>\n<td>a = 173; b = 144; c = 63.3; d = 56.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Thi\u1ebft k\u1ebf v\u1ecf K \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-013K-4<\/td>\n<td>a = 127; b = 87; c = 47; d = 6\u201315; SW = 44<\/td>\n<\/tr>\n<tr>\n<td>NM-023K-4<\/td>\n<td>a = 158; b = 105; c = 63; d = 10\u201320; SW = 54<\/td>\n<\/tr>\n<tr>\n<td>NM-013K<\/td>\n<td>a = 127; b = 87; c = 47; d = 6\u201315; SW = 44<\/td>\n<\/tr>\n<tr>\n<td>NM-023K<\/td>\n<td>a = 158; b = 105; c = 63; d = 10\u201320; SW = 54<\/td>\n<\/tr>\n<tr>\n<td>NM-014K<\/td>\n<td>a = 133; b = 97; c = 53; d = 6\u201315; SW = 44<\/td>\n<\/tr>\n<tr>\n<td>NM-024K<\/td>\n<td>a = 158; b = 105; c = 63; d = 10\u201320; SW = 54<\/td>\n<\/tr>\n<tr>\n<td>NM-015K<\/td>\n<td>a = 140; b = 105; c = 61; d = 6\u201315; SW = 44<\/td>\n<\/tr>\n<tr>\n<td>NM-025K<\/td>\n<td>a = 165; b = 121; c = 70; d = 10\u201320; SW = 54<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Thi\u1ebft k\u1ebf th\u00e2n sau m\u00e0u tr\u1eafng \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-013-4<\/td>\n<td>a = 122; b = 57; c = 50; \u03c6 = 6<\/td>\n<\/tr>\n<tr>\n<td>NM-023-4<\/td>\n<td>a = 141; b = 77; c = 64; \u03c6 = 8<\/td>\n<\/tr>\n<tr>\n<td>NM-013L<\/td>\n<td>a = 122; b = 57; c = 50; \u03c6 = 6<\/td>\n<\/tr>\n<tr>\n<td>NM-023L<\/td>\n<td>a = 141; b = 77; c = 64; \u03c6 = 8<\/td>\n<\/tr>\n<tr>\n<td>NM-013<\/td>\n<td>a = 122; b = 57; c = 50; \u03c6 = 6<\/td>\n<\/tr>\n<tr>\n<td>NM-023<\/td>\n<td>a = 141; b = 77; c = 64; \u03c6 = 8<\/td>\n<\/tr>\n<tr>\n<td>NM-014<\/td>\n<td>a = 122; b = 64; c = 50; \u03c6 = 6<\/td>\n<\/tr>\n<tr>\n<td>NM-024<\/td>\n<td>a = 141; b = 77; c = 64; \u03c6 = 8<\/td>\n<\/tr>\n<tr>\n<td>NM-015<\/td>\n<td>a = 130; b = 75; c = 64; \u03c6 = 8<\/td>\n<\/tr>\n<tr>\n<td>NM-025<\/td>\n<td>a = 144; b = 87; c = 70; \u03c6 = 8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-plugs-dimension.webp\" alt=\"IP44 Industrial Plugs dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-plugs-dimension-02.webp\" alt=\"IP44 Industrial Plugs dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-plugs-dimension-03.webp\" alt=\"IP44 Industrial Plugs dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-plugs-dimension-04.webp\" alt=\"IP44 Industrial Plugs dimension drawing\"><\/p>\n<h2>H\u01b0\u1edbng d\u1eabn l\u1ef1a ch\u1ecdn<\/h2>\n<p>Choose a male cable plug for a cable-end connection. A panel-mounted or surface-mounted appliance inlet uses a fixed mounting arrangement and belongs to a different product family.<\/p>\n<p>Select the current rating, contact arrangement, rated voltage, earth-contact clock position and IP rating together from one actual model row. Body color alone is insufficient: the special clock-position groups include different voltage\/contact combinations from the ordinary groups.<\/p>\n<p>Keep the complete suffix when selecting the housing version. Models that share an electrical rating may have different lengths, cable-entry dimensions or body shapes. Conductor capacity is a cross-sectional range in mm\u00b2 and must not be confused with a cable-entry dimension in mm.<\/p>\n<p>For five-contact models, the table preserves the paired 220\u2013380 \/ 240\u2013415 V notation. It does not create an additional arbitrary voltage combination. A dash in the capacity column means that the particular row supplies no confirmed value.<\/p>\n<h2>Th\u00f4ng tin \u0111\u1eb7t h\u00e0ng<\/h2>\n<p>When enquiring about YOCL ELECTRIC IP44 industrial plugs, provide the full model code, quantity, current rating, contact arrangement, rated voltage, clock position and the required housing design. Include the conductor cross-section and cable outside diameter so that the cable entry and terminal range can be checked for that specific model.<\/p>\n<p>Printed secondary references identify the catalogue entries where shown; they do not create extra model options or replace the full NM model code.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP44 ph\u00edch c\u1eafm c\u00f4ng nghi\u1ec7p cho k\u1ebft n\u1ed1i \u0111\u1ea7u c\u00e1p, v\u1edbi thi\u1ebft k\u1ebf v\u1ecf kh\u00e1c nhau v\u00e0 b\u1ea3ng l\u1ef1a ch\u1ecdn m\u1eabu NM \u0111\u1ea7y \u0111\u1ee7.<\/p>\n<ul>\n<li>D\u00f2ng \u0111\u1ecbnh m\u1ee9c: 16 A v\u00e0 32 A.<\/li>\n<li>C\u1ea5u h\u00ecnh ti\u1ebfp \u0111i\u1ec3m: 2P+E, 3P+E v\u00e0 3P+N+E.<\/li>\n<li>4h, 6h v\u00e0 c\u00e1c b\u1ed1 tr\u00ed ti\u1ebfp \u0111i\u1ec3m n\u1ed1i \u0111\u1ea5t 9h \u0111\u00e3 ch\u1ecdn, t\u00f9y thu\u1ed9c v\u00e0o m\u1eabu m\u00e3.<\/li>\n<li>Ph\u00edch c\u1eafm c\u00e1p \u0111\u1ef1c v\u1edbi l\u1ed1i v\u00e0o c\u00e1p ph\u00eda sau.<\/li>\n<li>Ch\u1ecdn \u0111i\u1ec7n \u00e1p, dung l\u01b0\u1ee3ng d\u00e2y d\u1eabn v\u00e0 k\u00edch th\u01b0\u1edbc theo m\u00e3 m\u1eabu \u0111\u1ea7y \u0111\u1ee7.<\/li>\n<\/ul>","protected":false},"featured_media":2857,"template":"","meta":[],"product_brand":[],"product_cat":[53],"product_tag":[],"class_list":["post-2862","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-plugs","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product\/2862","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/media\/2857"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/media?parent=2862"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_brand?post=2862"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_cat?post=2862"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_tag?post=2862"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}