{"id":2904,"date":"2026-10-07T14:42:24","date_gmt":"2026-10-07T14:42:24","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2904"},"modified":"2026-10-07T14:42:33","modified_gmt":"2026-10-07T14:42:33","slug":"ip67-surface-mounted-industrial-sockets","status":"publish","type":"product","link":"https:\/\/yocl.com\/vi\/product\/ip67-surface-mounted-industrial-sockets\/","title":{"rendered":"IP67 \u1ed4 c\u1eafm c\u00f4ng nghi\u1ec7p g\u1eafn n\u1ed5i"},"content":{"rendered":"<h2>T\u1ed5ng quan<\/h2>\n<p>YOCL ELECTRIC IP67 \u1ed5 c\u1eafm c\u00f4ng nghi\u1ec7p g\u1eafn b\u1ec1 m\u1eb7t cung c\u1ea5p \u0111i\u1ec3m k\u1ebft n\u1ed1i c\u00e1i c\u1ed1 \u0111\u1ecbnh cho ph\u00edch c\u1eafm c\u00f4ng nghi\u1ec7p t\u01b0\u01a1ng th\u00edch. D\u00f2ng s\u1ea3n ph\u1ea9m bao g\u1ed3m c\u00e1c \u0111\u1ecbnh m\u1ee9c 16 \/ 32 \/ 63 \/ 125 A v\u00e0 c\u00e1c c\u1ea5u h\u00ecnh ti\u1ebfp \u0111i\u1ec3m 2P+E, 3P+E, 3P+N+E. M\u1ed7i m\u1eabu k\u1ebft h\u1ee3p m\u1ed9t \u0111\u1ecbnh m\u1ee9c d\u00f2ng \u0111i\u1ec7n, \u0111i\u1ec7n \u00e1p, v\u1ecb tr\u00ed ti\u1ebfp \u0111i\u1ec3m n\u1ed1i \u0111\u1ea5t v\u00e0 thi\u1ebft k\u1ebf v\u1ecf c\u1ee5 th\u1ec3.<\/p>\n<p>C\u00e1c b\u1ea3ng ch\u1ecdn l\u1ecdc gi\u1eef c\u00e1c phi\u00ean b\u1ea3n v\u1ecf c\u00f3 s\u1eb5n c\u00f9ng nhau trong m\u1ed9t h\u1ecd s\u1ea3n ph\u1ea9m. S\u1eed d\u1ee5ng m\u00e3 model NM ho\u00e0n ch\u1ec9nh \u0111\u1ec3 ch\u1ec9 \u0111\u1ecbnh c\u1ea5u h\u00ecnh \u0111i\u1ec7n v\u00e0 k\u00edch th\u01b0\u1edbc l\u1eafp \u0111\u1eb7t t\u01b0\u01a1ng \u1ee9ng.<\/p>\n<h2>T\u00ednh n\u0103ng<\/h2>\n<ul>\n<li>V\u1ecf sau v\u00e0 c\u1ea5u tr\u00fac c\u1ed1 \u0111\u1ecbnh b\u1ec1 m\u1eb7t cho vi\u1ec7c l\u1eafp \u0111\u1eb7t \u1ed5 c\u1eafm c\u1ed1 \u0111\u1ecbnh.<\/li>\n<li>IP67 \u0111\u1ecbnh m\u1ee9c b\u1ea3o v\u1ec7 cho c\u00e1c m\u1eabu \u0111\u01b0\u1ee3c li\u1ec7t k\u00ea.<\/li>\n<li>N\u1eafp g\u1eadp \u1edf m\u1eb7t \u1ed5 c\u1eafm.<\/li>\n<li>C\u00e1c c\u1ea5u h\u00ecnh m\u00e0u xanh lam, \u0111\u1ecf v\u00e0 v\u00e0ng \u0111\u01b0\u1ee3c li\u1ec7t k\u00ea theo model ch\u00ednh x\u00e1c trong c\u00e1c b\u1ea3ng ch\u1ecdn l\u1ecdc.<\/li>\n<li>D\u1ea3i d\u00e2y d\u1eabn v\u00e0 k\u00edch th\u01b0\u1edbc l\u1eafp \u0111\u1eb7t theo m\u1eabu \u0111\u1ec3 ch\u1ecdn k\u1ebft n\u1ed1i \u0111i\u1ec7n v\u00e0 kh\u00f4ng gian l\u1eafp \u0111\u1eb7t.<\/li>\n<li>C\u00e1c v\u1ecb tr\u00ed ti\u1ebfp \u0111i\u1ec3m n\u1ed1i \u0111\u1ea5t thay th\u1ebf \u0111\u01b0\u1ee3c li\u1ec7t k\u00ea ri\u00eang; h\u00e3y kh\u1edbp v\u1ecb tr\u00ed n\u1ed1i \u0111\u1ea5t v\u1edbi c\u1ea5u h\u00ecnh ph\u00edch c\u1eafm d\u1ef1 \u0111\u1ecbnh.<\/li>\n<\/ul>\n<h2>Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt<\/h2>\n<table>\n<thead>\n<tr>\n<th>Tham s\u1ed1<\/th>\n<th>Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Th\u01b0\u01a1ng hi\u1ec7u<\/td>\n<td>YOCL \u0110I\u1ec6N<\/td>\n<\/tr>\n<tr>\n<td>Lo\u1ea1i s\u1ea3n ph\u1ea9m<\/td>\n<td>IP67 \u1ed4 c\u1eafm c\u00f4ng nghi\u1ec7p g\u1eafn n\u1ed5i<\/td>\n<\/tr>\n<tr>\n<td>Gi\u1edbi t\u00ednh ti\u1ebfp \u0111i\u1ec3m<\/td>\n<td>\u1ed4 c\u1eafm c\u00e1i<\/td>\n<\/tr>\n<tr>\n<td>L\u1eafp \u0111\u1eb7t<\/td>\n<td>G\u1eafn b\u1ec1 m\u1eb7t<\/td>\n<\/tr>\n<tr>\n<td>C\u1ea5p b\u1ea3o v\u1ec7<\/td>\n<td>IP67<\/td>\n<\/tr>\n<tr>\n<td>C\u00e1c t\u00f9y ch\u1ecdn d\u00f2ng \u0111i\u1ec7n \u0111\u1ecbnh m\u1ee9c<\/td>\n<td>16 \/ 32 \/ 63 \/ 125 A<\/td>\n<\/tr>\n<tr>\n<td>C\u1ea5u h\u00ecnh ti\u1ebfp \u0111i\u1ec3m<\/td>\n<td>2P+E \/ 3P+E \/ 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>C\u1ea5u h\u00ecnh \u0111i\u1ec7n \u00e1p<\/td>\n<td>110\u2013130 V; 220\u2013240 V; 380\u2013415 V; 220\u2013380 \/ 240\u2013415 V<\/td>\n<\/tr>\n<tr>\n<td>V\u1ecb tr\u00ed ti\u1ebfp \u0111i\u1ec3m n\u1ed1i \u0111\u1ea5t<\/td>\n<td>4 gi\u1edd \/ 6 gi\u1edd \/ 3 gi\u1edd<\/td>\n<\/tr>\n<tr>\n<td>Ti\u1ebft di\u1ec7n d\u00e2y d\u1eabn<\/td>\n<td>C\u00e1c gi\u00e1 tr\u1ecb d\u00e0nh ri\u00eang cho t\u1eebng m\u1eabu trong b\u1ea3ng ch\u1ecdn<\/td>\n<\/tr>\n<tr>\n<td>C\u00e1c phi\u00ean b\u1ea3n v\u1ecf<\/td>\n<td>V\u1ecf thi\u1ebft k\u1ebf 1, 16\/32 A; V\u1ecf thi\u1ebft k\u1ebf 2, 63\/125 A; V\u1ecf thi\u1ebft k\u1ebf 2, 16\/32 A; V\u1ecf ti\u00eau chu\u1ea9n, 63\/125 A; 3 gi\u1edd c\u1ea5u h\u00ecnh \u0111\u1eb7c bi\u1ec7t<\/td>\n<\/tr>\n<tr>\n<td>T\u00f9y ch\u1ecdn m\u1eabu m\u00e3<\/td>\n<td>28<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>B\u1ea3ng ch\u1ecdn m\u1eabu<\/h2>\n<p>C\u00e1c gi\u00e1 tr\u1ecb \u0111i\u1ec7n \u00e1p v\u00e0 d\u00f2ng \u0111i\u1ec7n thu\u1ed9c v\u1ec1 \u0111\u00fang h\u00e0ng m\u1eabu. D\u1ea5u g\u1ea1ch ngang cho bi\u1ebft kh\u00f4ng c\u00f3 gi\u00e1 tr\u1ecb d\u00e0nh ri\u00eang cho m\u1eabu n\u00e0o c\u00f3 s\u1eb5n trong d\u1eef li\u1ec7u \u0111\u01b0\u1ee3c cung c\u1ea5p.<\/p>\n<h3>V\u1ecf thi\u1ebft k\u1ebf 1, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>D\u00f2ng \u0111i\u1ec7n \u0111\u1ecbnh m\u1ee9c (A)<\/th>\n<th>Ti\u1ebfp \u0111i\u1ec3m<\/th>\n<th>\u0110i\u1ec7n \u00e1p (V)<\/th>\n<th>V\u1ecb tr\u00ed n\u1ed1i \u0111\u1ea5t<\/th>\n<th>M\u00e0u s\u1eafc<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1131-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>V\u00e0ng<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1231-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>V\u00e0ng<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1131<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1231<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1141<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1241<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1151<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1251<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>D\u00f2ng \u0111i\u1ec7n \u0111\u1ecbnh m\u1ee9c (A)<\/th>\n<th>Ti\u1ebfp \u0111i\u1ec3m<\/th>\n<th>\u0110i\u1ec7n \u00e1p (V)<\/th>\n<th>V\u1ecb tr\u00ed n\u1ed1i \u0111\u1ea5t<\/th>\n<th>M\u00e0u s\u1eafc<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1332<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-1432<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-1342<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-1442<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-1352<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-1452<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>D\u00f2ng \u0111i\u1ec7n \u0111\u1ecbnh m\u1ee9c (A)<\/th>\n<th>Ti\u1ebfp \u0111i\u1ec3m<\/th>\n<th>\u0110i\u1ec7n \u00e1p (V)<\/th>\n<th>V\u1ecb tr\u00ed n\u1ed1i \u0111\u1ea5t<\/th>\n<th>M\u00e0u s\u1eafc<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1132<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1232<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1142<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1242<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1152<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1252<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Standard housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>D\u00f2ng \u0111i\u1ec7n \u0111\u1ecbnh m\u1ee9c (A)<\/th>\n<th>Ti\u1ebfp \u0111i\u1ec3m<\/th>\n<th>\u0110i\u1ec7n \u00e1p (V)<\/th>\n<th>V\u1ecb tr\u00ed n\u1ed1i \u0111\u1ea5t<\/th>\n<th>M\u00e0u s\u1eafc<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-133<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-143<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Xanh d\u01b0\u01a1ng<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-134<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-144<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-135<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-145<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>3h special configurations<\/h3>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>D\u00f2ng \u0111i\u1ec7n \u0111\u1ecbnh m\u1ee9c (A)<\/th>\n<th>Ti\u1ebfp \u0111i\u1ec3m<\/th>\n<th>\u0110i\u1ec7n \u00e1p (V)<\/th>\n<th>V\u1ecb tr\u00ed n\u1ed1i \u0111\u1ea5t<\/th>\n<th>M\u00e0u s\u1eafc<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1142-3<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>3h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-1242-3<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>3h<\/td>\n<td>\u0110\u1ecf<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>K\u00edch th\u01b0\u1edbc<\/h2>\n<p>Dimension letters apply to the individual housing drawing. The same letter can identify a different feature on another housing version. Select the mounting dimensions from the exact model row.<\/p>\n<h3>V\u1ecf thi\u1ebft k\u1ebf 1, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>e1 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1131-4<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>115<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1231-4<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>143<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1131<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>115<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1231<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>143<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1141<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>124<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1241<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>143<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1151<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>124<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1251<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>150<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1332<\/td>\n<td>176<\/td>\n<td>171<\/td>\n<td>225<\/td>\n<td>119<\/td>\n<td>136<\/td>\n<td>103<\/td>\n<\/tr>\n<tr>\n<td>NM-1432<\/td>\n<td>180<\/td>\n<td>260<\/td>\n<td>305<\/td>\n<td>160<\/td>\n<td>241<\/td>\n<td>141<\/td>\n<\/tr>\n<tr>\n<td>NM-1342<\/td>\n<td>176<\/td>\n<td>171<\/td>\n<td>225<\/td>\n<td>119<\/td>\n<td>136<\/td>\n<td>103<\/td>\n<\/tr>\n<tr>\n<td>NM-1442<\/td>\n<td>180<\/td>\n<td>260<\/td>\n<td>305<\/td>\n<td>160<\/td>\n<td>241<\/td>\n<td>141<\/td>\n<\/tr>\n<tr>\n<td>NM-1352<\/td>\n<td>176<\/td>\n<td>171<\/td>\n<td>225<\/td>\n<td>119<\/td>\n<td>136<\/td>\n<td>103<\/td>\n<\/tr>\n<tr>\n<td>NM-1452<\/td>\n<td>180<\/td>\n<td>260<\/td>\n<td>305<\/td>\n<td>160<\/td>\n<td>241<\/td>\n<td>141<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1132<\/td>\n<td>145<\/td>\n<td>99<\/td>\n<\/tr>\n<tr>\n<td>NM-1232<\/td>\n<td>160<\/td>\n<td>108<\/td>\n<\/tr>\n<tr>\n<td>NM-1142<\/td>\n<td>150<\/td>\n<td>101<\/td>\n<\/tr>\n<tr>\n<td>NM-1242<\/td>\n<td>160<\/td>\n<td>108<\/td>\n<\/tr>\n<tr>\n<td>NM-1152<\/td>\n<td>150<\/td>\n<td>106<\/td>\n<\/tr>\n<tr>\n<td>NM-1252<\/td>\n<td>161<\/td>\n<td>111<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Base width 82; fixing width 71; vertical spacings 16, 48 and 40; side drawing 103.<\/p>\n<h3>Standard housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>M\u1eabu<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<th>g (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-133<\/td>\n<td>134<\/td>\n<td>311<\/td>\n<td>108<\/td>\n<td>111<\/td>\n<td>20<\/td>\n<td>155<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>NM-143<\/td>\n<td>154<\/td>\n<td>338<\/td>\n<td>122<\/td>\n<td>130<\/td>\n<td>20<\/td>\n<td>187<\/td>\n<td>6.2<\/td>\n<\/tr>\n<tr>\n<td>NM-134<\/td>\n<td>134<\/td>\n<td>311<\/td>\n<td>108<\/td>\n<td>111<\/td>\n<td>20<\/td>\n<td>155<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>NM-144<\/td>\n<td>154<\/td>\n<td>338<\/td>\n<td>122<\/td>\n<td>130<\/td>\n<td>20<\/td>\n<td>187<\/td>\n<td>6.2<\/td>\n<\/tr>\n<tr>\n<td>NM-135<\/td>\n<td>134<\/td>\n<td>311<\/td>\n<td>108<\/td>\n<td>111<\/td>\n<td>20<\/td>\n<td>155<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>NM-145<\/td>\n<td>154<\/td>\n<td>338<\/td>\n<td>122<\/td>\n<td>130<\/td>\n<td>20<\/td>\n<td>187<\/td>\n<td>6.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Cable-entry drawing PG29.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-02.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-03.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-04.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-05.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<h2>H\u01b0\u1edbng d\u1eabn l\u1ef1a ch\u1ecdn<\/h2>\n<ol>\n<li>Choose the rated current and contact arrangement required for the connection.<\/li>\n<li>Match the voltage configuration and earth contact position to the mating plug. Colour alone is insufficient for model selection.<\/li>\n<li>Select the housing version and use its own mounting and conductor-range values.<\/li>\n<li>Include the complete model code and quantity in the enquiry.<\/li>\n<\/ol>\n<h2>Th\u00f4ng tin \u0111\u1eb7t h\u00e0ng<\/h2>\n<p>For a quotation, provide the complete NM model code, required quantity and mounting version. If identifying a replacement, include a photograph of the existing contact face and mounting layout.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP67 \u1ed5 c\u1eafm c\u00f4ng nghi\u1ec7p g\u1eafn b\u1ec1 m\u1eb7t cho k\u1ebft n\u1ed1i ngu\u1ed3n c\u00f4ng nghi\u1ec7p c\u1ed1 \u0111\u1ecbnh.<\/p>\n<ul>\n<li>\u0110\u1ecbnh m\u1ee9c d\u00f2ng \u0111i\u1ec7n: 16 \/ 32 \/ 63 \/ 125 A.<\/li>\n<li>C\u1ea5u h\u00ecnh ti\u1ebfp \u0111i\u1ec3m: 2P+E \/ 3P+E \/ 3P+N+E.<\/li>\n<li>\u1ed4 c\u1eafm c\u00e1i c\u00f3 n\u1eafp g\u1eadp v\u00e0 v\u1ecf g\u1eafn ph\u00eda sau.<\/li>\n<li>B\u1ea3ng ch\u1ecdn m\u1eabu \u0111\u1ea7y \u0111\u1ee7 bao g\u1ed3m \u0111i\u1ec7n \u00e1p, v\u1ecb tr\u00ed ti\u1ebfp \u0111i\u1ec3m n\u1ed1i \u0111\u1ea5t, d\u1ea3i d\u00e2y d\u1eabn v\u00e0 k\u00edch th\u01b0\u1edbc c\u1ee5 th\u1ec3 c\u1ee7a v\u1ecf.<\/li>\n<li>Ch\u1ecdn v\u00e0 y\u00eau c\u1ea7u theo m\u00e3 m\u1eabu NM ho\u00e0n ch\u1ec9nh.<\/li>\n<\/ul>","protected":false},"featured_media":2898,"template":"","meta":[],"product_brand":[],"product_cat":[54],"product_tag":[],"class_list":["post-2904","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-sockets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product\/2904","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/media\/2898"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/media?parent=2904"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_brand?post=2904"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_cat?post=2904"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_tag?post=2904"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}