{"id":705,"date":"2026-09-29T13:10:21","date_gmt":"2026-09-29T13:10:21","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=705"},"modified":"2026-10-02T13:56:18","modified_gmt":"2026-10-02T13:56:18","slug":"lsv-lsd-pre-insulated-lock-fork-terminals","status":"publish","type":"product","link":"https:\/\/yocl.com\/vi\/product\/lsv-lsd-pre-insulated-lock-fork-terminals\/","title":{"rendered":"LSV\/LSD \u0110\u1ea7u cos c\u00e0ng kh\u00f3a c\u00e1ch \u0111i\u1ec7n"},"content":{"rendered":"<h2>T\u1ed5ng quan<\/h2>\n<p>YOCL ELECTRIC LSV\/LSD Pre-Insulated Lock Fork Terminals are copper fork terminals with PVC insulating sleeves for bolted conductor connections. LSV identifies the single-crimp construction and LSD the double-crimp construction with an additional copper tube and sleeve described in the supplied catalog. The page lists 14 matched model pairs in three conductor groups from 0.5 to 6 mm\u00b2.<\/p>\n<h2>Features<\/h2>\n<ul>\n<li><strong>Lock fork contact:<\/strong> the fork geometry shown in the catalog provides an open connection to a compatible bolt or stud.<\/li>\n<li><strong>Two crimp constructions:<\/strong> LSV and LSD model columns are paired by bolt fit and B, F and L dimensions; their barrel constructions differ.<\/li>\n<li><strong>Copper and PVC materials:<\/strong> the catalog states copper terminal material and PVC insulation for all three groups.<\/li>\n<li><strong>Group-specific ratings:<\/strong> Imax, material thickness and shared sleeve dimensions are shown by conductor group.<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Product type<\/td>\n<td>Pre-insulated lock fork terminal<\/td>\n<\/tr>\n<tr>\n<td>Series<\/td>\n<td>LSV single crimp; LSD double crimp<\/td>\n<\/tr>\n<tr>\n<td>Listed models<\/td>\n<td>14 LSV and 14 LSD<\/td>\n<\/tr>\n<tr>\n<td>Terminal material<\/td>\n<td>Copper<\/td>\n<\/tr>\n<tr>\n<td>Insulation<\/td>\n<td>PVC<\/td>\n<\/tr>\n<tr>\n<td>LSD construction<\/td>\n<td>Copper tube with sleeve, described as double pressure in the source<\/td>\n<\/tr>\n<tr>\n<td>Drawing dimension units<\/td>\n<td>mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The current figures are labelled Imax (maximum current) in the reference. Each figure applies to its own conductor group; operating conditions are not provided.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model group<\/th>\n<th>Color<\/th>\n<th>Conductor range<\/th>\n<th>AWG<\/th>\n<th>Imax<\/th>\n<th>Material thickness<\/th>\n<th>E (mm)<\/th>\n<th>D1 (mm), LSV<\/th>\n<th>D2 (mm), LSD<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>LSV\/LSD 1.25<\/td>\n<td>Red<\/td>\n<td>0.5\u20131.5 mm\u00b2<\/td>\n<td>AWG 22\u201316<\/td>\n<td>19 A<\/td>\n<td>0.7 mm<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<td>4.5<\/td>\n<\/tr>\n<tr>\n<td>LSV\/LSD 2<\/td>\n<td>Blue<\/td>\n<td>1.5\u20132.5 mm\u00b2<\/td>\n<td>AWG 16\u201314<\/td>\n<td>27 A<\/td>\n<td>0.8 mm<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<td>5.2<\/td>\n<\/tr>\n<tr>\n<td>LSV\/LSD 5.5<\/td>\n<td>Yellow<\/td>\n<td>4\u20136 mm\u00b2<\/td>\n<td>AWG 12\u201310<\/td>\n<td>48 A<\/td>\n<td>1.0 mm<\/td>\n<td>13.0<\/td>\n<td>6.7<\/td>\n<td>7.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimension<\/h2>\n<p>The drawing uses B, F, L and E for overall dimensions. The fork opening is d2; D1 applies to the LSV barrel and D2 to the LSD barrel. All dimensions below are in millimeters.<\/p>\n<table>\n<thead>\n<tr>\n<th>LSV single-crimp model<\/th>\n<th>LSD double-crimp model<\/th>\n<th>Color<\/th>\n<th>US bolt no.<\/th>\n<th>Fork opening d2 (mm)<\/th>\n<th>B (mm)<\/th>\n<th>F (mm)<\/th>\n<th>L (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>LSV 1.25-3.5<\/td>\n<td>LSD 1.25-3.5<\/td>\n<td>Red<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>6.4<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<\/tr>\n<tr>\n<td>LSV 1.25-4S<\/td>\n<td>LSD 1.25-4S<\/td>\n<td>Red<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>7.2<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<\/tr>\n<tr>\n<td>LSV 1.25-4L<\/td>\n<td>LSD 1.25-4L<\/td>\n<td>Red<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.1<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<\/tr>\n<tr>\n<td>LSV 1.25-5S<\/td>\n<td>LSD 1.25-5S<\/td>\n<td>Red<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>8.1<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<\/tr>\n<tr>\n<td>LSV 1.25-5L<\/td>\n<td>LSD 1.25-5L<\/td>\n<td>Red<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<\/tr>\n<tr>\n<td>LSV 2-3.5<\/td>\n<td>LSD 2-3.5<\/td>\n<td>Blue<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>6.0<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<\/tr>\n<tr>\n<td>LSV 2-4S<\/td>\n<td>LSD 2-4S<\/td>\n<td>Blue<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>7.2<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<\/tr>\n<tr>\n<td>LSV 2-4L<\/td>\n<td>LSD 2-4L<\/td>\n<td>Blue<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.1<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<\/tr>\n<tr>\n<td>LSV 2-5S<\/td>\n<td>LSD 2-5S<\/td>\n<td>Blue<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>8.1<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<\/tr>\n<tr>\n<td>LSV 2-5L<\/td>\n<td>LSD 2-5L<\/td>\n<td>Blue<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.3<\/td>\n<td>6.5<\/td>\n<td>21.2<\/td>\n<\/tr>\n<tr>\n<td>LSV 5.5-3.5<\/td>\n<td>LSD 5.5-3.5<\/td>\n<td>Yellow<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>8.3<\/td>\n<td>7.0<\/td>\n<td>25.2<\/td>\n<\/tr>\n<tr>\n<td>LSV 5.5-4<\/td>\n<td>LSD 5.5-4<\/td>\n<td>Yellow<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.3<\/td>\n<td>7.0<\/td>\n<td>25.2<\/td>\n<\/tr>\n<tr>\n<td>LSV 5.5-5<\/td>\n<td>LSD 5.5-5<\/td>\n<td>Yellow<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.0<\/td>\n<td>7.0<\/td>\n<td>25.2<\/td>\n<\/tr>\n<tr>\n<td>LSV 5.5-6<\/td>\n<td>LSD 5.5-6<\/td>\n<td>Yellow<\/td>\n<td>1\/4<\/td>\n<td>6.4<\/td>\n<td>12.0<\/td>\n<td>12.0<\/td>\n<td>31.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>E, D1 and D2 are shared within each conductor group in the technical specifications above. The reference drawing marks a plate thickness T but does not provide a numerical T value.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/09\/lsv-lsd-pre-insulated-lock-fork-terminals-dimension.webp\" alt=\"LSV\/LSD Pre-Insulated Lock Fork Terminals dimension drawing\" \/><\/p>\n<h2>Selection Guide<\/h2>\n<p>Choose LSV or LSD construction and the conductor group first. Then check fork opening d2 against the intended bolt or stud and compare B, F, L and the applicable barrel dimensions with the available connection space. Use the exact LSV or LSD model code when ordering.<\/p>\n<h2>Ordering Information<\/h2>\n<p>Specify the LSV or LSD model and quantity when requesting a quotation.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC LSV\/LSD Pre-Insulated Lock Fork Terminals are copper terminals with PVC insulation for bolted conductor connections. The combined series lists 14 matched pairs: LSV single crimp and LSD double crimp, covering conductor groups from 0.5 to 6 mm\u00b2.<\/p>\n<ul>\n<li>Choose the conductor group and fork opening d2 for the intended bolt or stud.<\/li>\n<li>Compare B, F and L by model, with E, D1 and D2 dimensions specified by group.<\/li>\n<li>Red, blue and yellow insulation identifies the listed groups.<\/li>\n<\/ul>","protected":false},"featured_media":1798,"template":"","meta":[],"product_brand":[],"product_cat":[158],"product_tag":[],"class_list":["post-705","product","type-product","status-publish","has-post-thumbnail","product_cat-pvc-insulated-terminals","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product\/705","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/media\/1798"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/media?parent=705"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_brand?post=705"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_cat?post=705"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_tag?post=705"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}