{"id":849,"date":"2026-09-29T15:56:20","date_gmt":"2026-09-29T15:56:20","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=849"},"modified":"2026-10-04T11:25:13","modified_gmt":"2026-10-04T11:25:13","slug":"shb-heat-shrinkable-fork-terminals","status":"publish","type":"product","link":"https:\/\/yocl.com\/vi\/product\/shb-heat-shrinkable-fork-terminals\/","title":{"rendered":"SHB Heat Shrinkable Fork Terminals (TU Type)"},"content":{"rendered":"<h2>T\u1ed5ng quan<\/h2>\n<p>SHB Heat Shrinkable Fork Terminals (TU Type) are copper fork terminals with heat-shrink sleeves for bolted conductor connections. The supplied catalog lists 29 models in red, blue and yellow conductor groups. Bolt-hole and B, F and L dimensions are specified by model.<\/p>\n<h2>Features<\/h2>\n<ul>\n<li><strong>Heat-shrink sleeve:<\/strong> the source gives an initial shrink temperature of 80 \u00b0C and a minimum temperature of 130 \u00b0C for complete shrinkage.<\/li>\n<li><strong>Copper fork terminal:<\/strong> the conductive terminal material is listed as copper.<\/li>\n<li><strong>Group-specific selection:<\/strong> conductor section, Imax, material thickness and E\/D dimensions differ by group.<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Catalog specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Product type<\/td>\n<td>Heat shrinkable fork terminal, TU type<\/td>\n<\/tr>\n<tr>\n<td>Series<\/td>\n<td>SHB<\/td>\n<\/tr>\n<tr>\n<td>Listed models<\/td>\n<td>29<\/td>\n<\/tr>\n<tr>\n<td>Terminal material<\/td>\n<td>Copper<\/td>\n<\/tr>\n<tr>\n<td>Heat-shrink sleeve material<\/td>\n<td>Not specified in the source<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>\u221255 to +125 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Initial shrink temperature<\/td>\n<td>80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Minimum full shrink temperature<\/td>\n<td>130 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Dimension units<\/td>\n<td>mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The catalog labels its current figures Imax by conductor group; it gives no test or installation conditions. No ingress-protection rating or insulation-voltage rating is supplied.<\/p>\n<table>\n<thead>\n<tr>\n<th>Group<\/th>\n<th>Conductor section<\/th>\n<th>AWG<\/th>\n<th>Imax<\/th>\n<th>Material thickness (mm)<\/th>\n<th>E (mm)<\/th>\n<th>D (mm)<\/th>\n<th>Sleeve color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SHB 1.25<\/td>\n<td>0.5\u20131.5 mm\u00b2<\/td>\n<td>22\u201316<\/td>\n<td>19 A<\/td>\n<td>0.7<\/td>\n<td>19.0<\/td>\n<td>4.8<\/td>\n<td>Red<\/td>\n<\/tr>\n<tr>\n<td>SHB 2<\/td>\n<td>1.5\u20132.5 mm\u00b2<\/td>\n<td>16\u201314<\/td>\n<td>27 A<\/td>\n<td>0.8<\/td>\n<td>19.0<\/td>\n<td>5.8<\/td>\n<td>Blue<\/td>\n<\/tr>\n<tr>\n<td>SHB 5.5<\/td>\n<td>4\u20136 mm\u00b2<\/td>\n<td>12\u201310<\/td>\n<td>48 A<\/td>\n<td>1.0<\/td>\n<td>22.0<\/td>\n<td>6.8<\/td>\n<td>Yellow<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimension<\/h2>\n<p>The supplied drawing labels the fork bolt-hole diameter d2 and dimensions B, F, L, E and D. E and D are group values repeated with each model for direct comparison. All dimensions are in millimeters.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Color<\/th>\n<th>US bolt no.<\/th>\n<th>Bolt-hole d2 (mm)<\/th>\n<th>B (mm)<\/th>\n<th>F (mm)<\/th>\n<th>L (mm)<\/th>\n<th>E (mm)<\/th>\n<th>D (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SHB 1.25-3<\/td>\n<td>Red<\/td>\n<td>#4<\/td>\n<td>3.2<\/td>\n<td>5.7<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 1.25-3.5S<\/td>\n<td>Red<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>5.7<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 1.25-3.5L<\/td>\n<td>Red<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>6.4<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 1.25-4S<\/td>\n<td>Red<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>6.4<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 1.25-4M<\/td>\n<td>Red<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>7.2<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 1.25-4L<\/td>\n<td>Red<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.1<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 1.25-5S<\/td>\n<td>Red<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>8.1<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 1.25-5L<\/td>\n<td>Red<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 1.25-6S<\/td>\n<td>Red<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>9.5<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 1.25-6L<\/td>\n<td>Red<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>11.0<\/td>\n<td>36.0<\/td>\n<td>19.0<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 1.25-8<\/td>\n<td>Red<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>14.0<\/td>\n<td>12.5<\/td>\n<td>38.0<\/td>\n<td>19.0<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 2-3<\/td>\n<td>Blue<\/td>\n<td>#4<\/td>\n<td>3.2<\/td>\n<td>5.7<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 2-3.5S<\/td>\n<td>Blue<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>5.7<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 2-3.5L<\/td>\n<td>Blue<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>6.4<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 2-4S<\/td>\n<td>Blue<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>6.4<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 2-4M<\/td>\n<td>Blue<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>7.2<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 2-4L<\/td>\n<td>Blue<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.1<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 2-5S<\/td>\n<td>Blue<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>8.1<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 2-5L<\/td>\n<td>Blue<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 2-6S<\/td>\n<td>Blue<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>9.5<\/td>\n<td>6.5<\/td>\n<td>30.0<\/td>\n<td>19.0<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 2-6L<\/td>\n<td>Blue<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>11.0<\/td>\n<td>36.0<\/td>\n<td>19.0<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 2-8<\/td>\n<td>Blue<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>14.0<\/td>\n<td>12.5<\/td>\n<td>38.0<\/td>\n<td>19.0<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 5.5-3.5<\/td>\n<td>Yellow<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>8.3<\/td>\n<td>7.5<\/td>\n<td>34.3<\/td>\n<td>22.0<\/td>\n<td>6.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 5.5-4S<\/td>\n<td>Yellow<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.3<\/td>\n<td>7.5<\/td>\n<td>34.3<\/td>\n<td>22.0<\/td>\n<td>6.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 5.5-4L<\/td>\n<td>Yellow<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>9.0<\/td>\n<td>7.5<\/td>\n<td>34.3<\/td>\n<td>22.0<\/td>\n<td>6.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 5.5-5<\/td>\n<td>Yellow<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.0<\/td>\n<td>7.5<\/td>\n<td>34.3<\/td>\n<td>22.0<\/td>\n<td>6.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 5.5-6S<\/td>\n<td>Yellow<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>9.0<\/td>\n<td>7.5<\/td>\n<td>34.3<\/td>\n<td>22.0<\/td>\n<td>6.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 5.5-6L<\/td>\n<td>Yellow<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>12.0<\/td>\n<td>40.3<\/td>\n<td>22.0<\/td>\n<td>6.8<\/td>\n<\/tr>\n<tr>\n<td>SHB 5.5-8<\/td>\n<td>Yellow<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>14.0<\/td>\n<td>11.5<\/td>\n<td>39.3<\/td>\n<td>22.0<\/td>\n<td>6.8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Selection Guide<\/h2>\n<p>Match the conductor group, fork bolt-hole diameter and dimensions to the intended connection. Specify the exact SHB model code and required quantity when requesting a quotation.<\/p>\n<h2>Dimension<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/09\/shb-heat-shrinkable-fork-terminals-tu-type-dimension.webp\" alt=\"SHB Heat Shrinkable Fork Terminals (TU Type) dimension drawing\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>SHB TU-type heat shrinkable fork terminals combine a copper fork terminal with a heat-shrink sleeve. The catalog lists 29 models for 0.5\u20136 mm\u00b2 conductors.<\/p>\n<ul>\n<li>Red, blue and yellow groups have separate Imax, tube thickness and E\/D dimensions.<\/li>\n<li>Source operating range: \u221255 to +125 \u00b0C; initial shrink temperature: 80 \u00b0C.<\/li>\n<li>Select by conductor group, bolt-hole diameter and B\/F\/L dimensions.<\/li>\n<\/ul>","protected":false},"featured_media":2066,"template":"","meta":[],"product_brand":[],"product_cat":[110],"product_tag":[],"class_list":["post-849","product","type-product","status-publish","has-post-thumbnail","product_cat-heat-shrink-crimp-terminals","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product\/849","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/media\/2066"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/media?parent=849"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_brand?post=849"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_cat?post=849"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/vi\/wp-json\/wp\/v2\/product_tag?post=849"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}