YOCL

MDNY/MDNYD Nylon Male Terminals (Single and Double Crimp)

YOCL ELECTRIC MDNY/MDNYD nylon male terminals combine a brass tab with an insulated crimp barrel. MDNY is the single-crimp version; MDNYD is the double-crimp version.

  • 14 paired model rows across three conductor groups.
  • Conductor sections: 0.5–1.5, 1.5–2.5 and 4–6 mm².
  • Group maximum currents: 10, 15 and 24 A.
  • NEMA tab, material thickness, B, d, D, L and E are listed.
Produkt anfragen

Übersicht

YOCL ELECTRIC MDNY/MDNYD Nylon Male Terminals are brass male tabs with nylon insulated crimp barrels. MDNY is the single-crimp version; MDNYD adds the double-crimp sleeve. The catalogue lists 14 paired model rows in three conductor groups.

Merkmale

  • Two crimp styles: paired MDNY and MDNYD model codes share a row for selection.
  • Brass terminal and nylon insulation: materials stated in the source and confirmed for this catalogue.
  • Multiple tab sizes: the listed NEMA tab and material thickness vary by model.

Technische Daten

Parameter Specification
Product type Insulated male tab terminal
Series MDNY (single crimp); MDNYD (double crimp)
Terminal material Brass
Insulation material Nylon
Double-crimp construction Copper tube with sleeve
Listed models 14 MDNY; 14 MDNYD

Maximum current and E are group-specific; use the row matching the selected model.

Size group Conductor section (mm²) AWG Max current (A) Color E (mm)
1.25 0.5–1.5 22–16 10 Red 11.0
2 1.5–2.5 16–14 15 Blue 11.0
5.5 4–6 12–10 24 Yellow 13.0

Abmessung

All dimensions are in millimeters. The NEMA tab, material thickness, B, d, D and L values follow the source table.

Single-crimp model Double-crimp model NEMA tab (mm) Material thickness (mm) B (mm) d (mm) D (mm) L (mm)
MDNY 1.25-110(5) MDNYD 1.25-110(5) 0.5 × 2.8 0.5 2.8 1.7 3.8 18.7
MDNY 1.25-110(8) MDNYD 1.25-110(8) 0.8 × 2.8 0.8 2.8 1.7 3.8 18.7
MDNY 1.25-187(5) MDNYD 1.25-187(5) 0.5 × 4.75 0.5 4.75 1.7 3.8 21.0
MDNY 1.25-187(8) MDNYD 1.25-187(8) 0.4 × 4.75 0.8 4.75 1.7 3.8 21.0
MDNY 1.25-250 MDNYD 1.25-250 0.8 × 6.35 0.8 6.35 1.7 3.8 22.0
MDNY 2-110(5) MDNYD 2-110(5) 0.5 × 2.8 0.5 2.8 2.3 4.3 18.7
MDNY 2-110(8) MDNYD 2-110(8) 0.8 × 2.8 0.8 2.8 2.3 4.3 18.7
MDNY 2-187(5) MDNYD 2-187(5) 0.5 × 4.75 0.5 4.75 2.3 4.3 21.0
MDNY 2-187(8) MDNYD 2-187(8) 0.4 × 4.75 0.8 4.75 2.3 4.3 21.0
MDNY 2-250 MDNYD 2-250 0.8 × 6.35 0.8 6.35 2.3 4.3 22.0
MDNY 5.5-110(5) MDNYD 5.5-110(5) 0.5 × 2.8 0.5 2.8 3.4 5.7 21.0
MDNY 5.5-110(8) MDNYD 5.5-110(8) 0.8 × 2.8 0.8 2.8 3.4 5.7 21.0
MDNY 5.5-187 MDNYD 5.5-187 0.5 × 4.75 0.5 4.75 3.4 5.7 23.0
MDNY 5.5-250 MDNYD 5.5-250 0.8 × 6.35 0.8 6.35 3.4 5.7 24.0

MDNY/MDNYD Nylon Male Terminals (Single and Double Crimp) dimension drawing

Selection Guide

Select the conductor size group and crimp style, then match the tab size and model dimensions to the mating connection. Use the maximum current stated for that group.

Anwendungen

For compatible male tab connections in electrical equipment.

Bestellinformationen

Provide the full MDNY or MDNYD model and quantity when requesting a quotation.

Projektdetails

Felder mit * sind erforderlich.

Ihre Daten werden verwendet, um auf Ihre Anfrage zu antworten. Datenschutzhinweis