Incoming & outgoing conductors
List conductor material, cross-section and preparation for every input and output. Confirm the acceptance range of each position on the chosen model.
UKK, K and UTJ5 DIN rail distribution blocks for electrical panels. Compare incoming and outgoing connection arrangements, conductor capacities and panel dimensions before choosing your model.

| Construcción | Enfoque de selección | Referencia de serie |
|---|---|---|
| UKK single-pole distribution | Six models with listed ratings of 80–500 A at 690 V. Compare 1-in/6-out and 1-in/11-out arrangements and the capacity of each connection position. | UKK-80A · 125A · 160A · 250A · 400A · 500A |
| K multi-way assemblies | Six 2-way or 4-way models with brass conductive parts and PC/PA insulation. Compare connection-hole arrangements and 46 mm or 86 mm housing widths. | K207 · K211 · K215 · K407 · K411 · K415 |
| UTJ5 direct & branch connections | Ten models with individual ratings of 63–380 A at 800 V. Select 1-in/1-out, 1-in/3-out or 1-in/5-out arrangements with internal hex socket screw connections. | UTJ5-16 through UTJ5-240; multi-output variants available |
A matching current rating alone is not enough. Check every conductor position and the installation space.
List conductor material, cross-section and preparation for every input and output. Confirm the acceptance range of each position on the chosen model.
Specify the required number of inputs and outputs. Distinguish UKK branching, K multi-way assemblies and UTJ5 direct or multi-output connections.
Provide operating current and voltage. Use the rating of the exact model; the highest rating in a series does not apply to every model.
Check rail mounting, block dimensions, conductor access and cover clearance. Confirm tightening and conductor preparation requirements for the selected model.
Send your UKK, K or UTJ5 models, input/output conductor schedule and quantities for a quotation.
Prepare an enquiryAgree the specification and required evidence before placing your order.
Explorar fabricaciónList UKK, K or UTJ5 model references, quantities and required housing colours.
Send conductor material and cross-section for each position, together with the required branch arrangement.
Provide current, voltage, rail layout and available width, height and depth.
Specify labels, pack quantities, delivery destination and required model-specific documents.

OEM & PACKING
Build your power distribution blocks order around the selected models, identification and supply requirements.
List UKK, K or UTJ5 model references, quantities and required housing colours.
Provide part numbers, label artwork and any batch or traceability information required for the order.
Specify quantities per model, individual packs, outer cartons and delivery destination.
UKK is a single-pole branching range. K provides 2-way or 4-way assemblies with model-specific connection-hole arrangements. UTJ5 includes direct and multi-output connections using an aluminum conductive body. Compare the exact connection arrangement, conductor capacity, rating and dimensions rather than substituting by series name.
No. UKK has individual model ratings from 80 A to 500 A, while UTJ5 has individual ratings from 63 A to 380 A. These maxima apply only to their corresponding models. Do not infer a K model current rating from a UKK or UTJ5 rating.
No. K connection-hole diameters are mechanical dimensions, not conductor cross-section ratings. Confirm the permitted conductor sizes for the selected model and connection position.
No. Six listed models have one input and one output. UTJ5-35-2, UTJ5-50-2 and UTJ5-95-2 have one input and three outputs; UTJ5-50-3 has one input and five outputs.
Send your UKK, K or UTJ5 models, input/output conductor schedule and quantities for a quotation. Include the exact model quantities, delivery destination and required documentation.
Send your part numbers, label artwork, pack quantities and shipment requirements. Feasibility, sample requirements, minimum quantities and lead time are confirmed for the requested models.