Terminais Forquilha Convexos em Nylon FSNY / FSNYD
FSNY and FSNYD nylon convex fork terminals are copper fork terminals with insulated sleeves. FSNY is the single-crimp style; FSNYD adds a copper tube sleeve for double crimp.
- One combined listing with 29 paired rows and 58 model codes.
- Red, blue and yellow groups cover 0.5–1.5, 1.5–2.5 and 4–6 mm² conductors.
- Select by conductor group, bolt size and B, F, L, A, E, D1 and D2 dimensions.
Visão Geral
FSNY / FSNYD Nylon Convex Fork Terminals are insulated copper convex fork terminals for bolted electrical connections. The FSNY models use a single crimp; their matching FSNYD models use a double crimp with a copper tube sleeve. Both styles are combined below for direct model and dimension comparison.
Características
- Paired crimp styles: each listed FSNY model has an FSNYD double-crimp counterpart.
- Fork connection: the open fork fits the corresponding bolt size shown for each model.
- Copper terminal and insulated sleeve: the source catalog identifies copper terminal material and a nylon sleeve.
- Color-coded size groups: red, blue and yellow identify the three listed conductor ranges.
Especificações Técnicas
| Parâmetro | Catalog specification |
|---|---|
| Product type | Nylon-insulated convex fork terminal |
| Series | FSNY single crimp; FSNYD double crimp |
| Terminal material | Copper |
| Insulation | Nylon sleeve, labeled “Nylon (PP)” in source |
| Double-crimp construction | Copper tube with sleeve |
| Listed models | 29 FSNY and 29 matching FSNYD models |
| Catalog temperature / voltage | 105 °C / 600 V |
The following Imax values are given by conductor group in the catalog. Test and operating conditions are not specified.
| Color / size group | Conductor section (mm²) | AWG | Catalog Imax (A) | Material thickness T (mm) | A (mm) | E (mm) | D1 (mm) | D2 (mm) |
|---|---|---|---|---|---|---|---|---|
| Red / 1.25 | 0.5–1.5 | 22–16 | 19 | 0.7 | 1.5 | 11.0 | 4.3 | 4.8 |
| Blue / 2 | 1.5–2.5 | 16–14 | 27 | 0.8 | 1.5 | 11.0 | 4.9 | 5.6 |
| Yellow / 5.5 | 4–6 | 12–10 | 48 | 1.0 | 1.5 | 14.0 | 6.9 | 7.2 |
Dimensão
All dimensions in the model table are in millimeters. A, E, D1 and D2 are given by conductor group above. The USA bolt number and metric bolt diameter d2 are both retained from the source table.
| FSNY single-crimp model | FSNYD double-crimp model | USA bolt No. | Bolt diameter d2 (mm) | B (mm) | F (mm) | L (mm) |
|---|---|---|---|---|---|---|
| FSNY1.25-3 | FSNYD1.25-3 | #4 | 3.2 | 5.7 | 6.5 | 22.0 |
| FSNY1.25-3.5S | FSNYD1.25-3.5S | #6 | 3.7 | 5.7 | 6.5 | 22.0 |
| FSNY1.25-3.5L | FSNYD1.25-3.5L | #6 | 3.7 | 6.4 | 6.5 | 22.0 |
| FSNY1.25-4S | FSNYD1.25-4S | #8 | 4.3 | 6.4 | 6.5 | 22.0 |
| FSNY1.25-4M | FSNYD1.25-4M | #8 | 4.3 | 7.2 | 6.5 | 22.0 |
| FSNY1.25-4L | FSNYD1.25-4L | #8 | 4.3 | 8.1 | 6.5 | 22.0 |
| FSNY1.25-5S | FSNYD1.25-5S | #10 | 5.3 | 8.1 | 6.5 | 22.0 |
| FSNY1.25-5L | FSNYD1.25-5L | #10 | 5.3 | 9.5 | 6.5 | 22.0 |
| FSNY1.25-6S | FSNYD1.25-6S | 1/4 | 6.5 | 9.5 | 6.5 | 22.0 |
| FSNY1.25-6L | FSNYD1.25-6L | 1/4 | 6.5 | 12.0 | 11.0 | 28.0 |
| FSNY1.25-8 | FSNYD1.25-8 | 5/16 | 8.5 | 14.0 | 12.5 | 30.0 |
| FSNY2-3 | FSNYD2-3 | #4 | 3.2 | 5.7 | 6.5 | 22.0 |
| FSNY2-3.5S | FSNYD2-3.5S | #6 | 3.7 | 5.7 | 6.5 | 22.0 |
| FSNY2-3.5L | FSNYD2-3.5L | #6 | 3.7 | 6.4 | 6.5 | 22.0 |
| FSNY2-4S | FSNYD2-4S | #8 | 4.3 | 6.4 | 6.5 | 22.0 |
| FSNY2-4M | FSNYD2-4M | #8 | 4.3 | 7.2 | 6.5 | 22.0 |
| FSNY2-4L | FSNYD2-4L | #8 | 4.3 | 8.1 | 6.5 | 22.0 |
| FSNY2-5S | FSNYD2-5S | #10 | 5.3 | 8.1 | 6.5 | 22.0 |
| FSNY2-5L | FSNYD2-5L | #10 | 5.3 | 9.5 | 6.5 | 22.0 |
| FSNY2-6S | FSNYD2-6S | 1/4 | 6.5 | 9.5 | 6.5 | 22.0 |
| FSNY2-6L | FSNYD2-6L | 1/4 | 6.5 | 12.0 | 11.0 | 28.0 |
| FSNY2-8 | FSNYD2-8 | 5/16 | 8.5 | 14.0 | 12.5 | 30.0 |
| FSNY5.5-3.5 | FSNYD5.5-3.5 | #6 | 3.7 | 8.3 | 7.5 | 26.5 |
| FSNY5.5-4S | FSNYD5.5-4S | #8 | 4.3 | 8.3 | 7.5 | 26.5 |
| FSNY5.5-4L | FSNYD5.5-4L | #8 | 4.3 | 9.0 | 7.5 | 26.5 |
| FSNY5.5-5 | FSNYD5.5-5 | #10 | 5.3 | 9.0 | 7.5 | 26.5 |
| FSNY5.5-6S | FSNYD5.5-6S | 1/4 | 6.5 | 9.0 | 7.5 | 26.5 |
| FSNY5.5-6L | FSNYD5.5-6L | 1/4 | 6.5 | 12.0 | 12.0 | 32.5 |
| FSNY5.5-8 | FSNYD5.5-8 | 5/16 | 8.5 | 14.0 | 11.5 | 31.0 |


Guia de Seleção
Select the conductor range first, then match the d2 fork opening to the intended bolt. Compare B, F, L and the group dimensions A, E, D1 and D2 with the available installation space, and specify FSNY or FSNYD by crimp style.
Informações de Encomenda