YOCL

BDM-21 Hexagonal Flameproof Barrier Ex d Cable Gland

BDM-21 hexagonal single compression armored cable gland with an outer clamping seal and inner putty compound barrier.

  • Brass, nickel-plated brass, SS304 or SS316 body options.
  • Specified IP66, IP67 and IP68 protection (IP68: 1 m, 1 h).
  • 20 sizes with separate inner sheath, outer sheath and armor ranges.
  • Metric and NPT thread options; G thread for Ex e and Ex t only.
  • Standard nylon washer and locknut, except for NPT versions.
Запрос по этому продукту

Обзор

The YOCL ELECTRIC BDM-21 Hexagonal Flameproof Barrier Ex d Cable Gland uses a single compression armored construction with an outer clamping seal and an inner putty compound barrier. The hexagonal metal body is available in brass, nickel-plated brass, SS304 and SS316.

The supplied specification lists hazardous-area applications in Zones 1, 2, 21 and 22. Metric and NPT options are listed for the Ex applications described below; G-thread options are restricted to increased safety and dust-protection applications.

Характеристики

  • Compound barrier construction: Inner putty compound sealing with an outer clamping seal.
  • Hexagonal body: Defined wrench flats for handling during assembly.
  • Armored cable selection: Model-specific inner sheath, outer sheath and armor thickness data.
  • Body material options: Brass, nickel-plated brass, SS304 and SS316.
  • Thread options: Standard metric sizes and NPT/G nominal sizes, with separately listed CNEx custom metric thread options.

Технические характеристики

Parameter Specification
Модель BDM-21
Type Hexagonal single compression armored type
Sealing Outer clamping seal; inner putty compound barrier
Body material options Brass; nickel-plated brass; SS304; SS316
Sealing material options Silicone rubber; neoprene; PTFE (Teflon); PA6
Operating temperature options −40 °C to +100 °C / −60 °C to +80 °C, depending on configuration
Supplied Ex marking Ex db IIC Gb; Ex eb IIC Gb; Ex tb IIIC Db, subject to thread configuration
Ingress protection IP66; IP67; IP68 (1 m, 1 h)
Listed hazardous area applications Zone 1; Zone 2; Zone 21; Zone 22
Thread options Metric; NPT; BSP (G)
G-thread application restriction Ex e and Ex t only; not listed for Ex d
Stated flammability classification UL 94 V-0
Approvals stated in supplied specification IECEx; ATEX; EAC (CUTR); CNEx; CCC
Standards listed in supplied specification IEC/EN 60079-0; IEC/EN 60079-1; IEC/EN 60079-31; IEC/EN 60079-7; IEC/EN 60529; GB 3836
Standard accessories Nylon washer and locknut, except for NPT versions
Optional accessories Earth tag; PVC shroud; serrated washer; red fibre washer; A/B putty compound

Temperature limits and approval scope depend on the selected configuration. The supplied data does not map the temperature options to sealing materials or provide certificate numbers. UL 94 V-0 is the stated flammability classification; the specific material scope is not identified.

Размеры

Cable and Armor Selection

Dimensions are in millimetres, except the NPT/G nominal thread sizes in inches. Strict less-than limits for the inner sheath A are retained as supplied.

Size Metric entry thread AG NPT/G nominal size (inch) Inner sheath A (mm) Outer sheath B (mm) Armor range h (mm)
16A M16×1.5 3/8 <8 5.5–12 0.3–1.0
16B M16×1.5 3/8 <8 9.5–16 0.3–1.0
20A M20×1.5 1/2 <11 5.5–12 0.3–1.0
20B M20×1.5 1/2 <11 9.5–16 0.3–1.0
20C M20×1.5 1/2 <15 12.5–20.5 0.3–1.0
25B M25×1.5 3/4 <15 12.5–20.5 0.3–1.0
25C M25×1.5 3/4 <21 17–26 0.4–1.2
32B M32×1.5 1 <21 17–26 0.4–1.2
32C M32×1.5 1 <27 22–33 0.4–1.4
40B M40×1.5 1-1/4 <27 22–33 0.6–1.9
40C M40×1.5 1-1/4 <33 28–41 0.6–2.2
50B M50×1.5 1-1/2 <33 28–41 0.8–2.3
50C M50×1.5 1-1/2 <42 36–52.6 0.8–2.3
63B M63×1.5 2 <42 36–52.6 0.9–2.4
63C M63×1.5 2 <54.5 46–64 0.9–2.4
75B M75×1.5 2-1/2 <54.5 46–64 0.9–2.4
75C M75×1.5 2-1/2 <66 57–78 0.9–2.4
80 M80×1.5 3 <66 57–78 0.9–2.4
90 M90×1.5 3 <75 68–88 0.9–2.8
100 M100×1.5 4 <90 83–103 0.9–2.8

Specify NPT or BSP (G) explicitly when ordering an inch-size entry thread. The shared nominal-size column does not imply the same Ex application for both thread standards.

External Dimensions

Size Maximum size D (mm) Body length L1 (mm) Entry thread length L (mm)
16A 29 60 16
16B 29 60 16
20A 29 60 16
20B 29 60 16
20C 37 60 16
25B 37 60 16
25C 44 67 16
32B 44 67 18
32C 55 73 18
40B 55 73 18
40C 67 81 18
50B 67 81 20
50C 73 102 20
63B 73 102 21
63C 89 105 21
75B 89 105 22
75C 105 105 22
80 105 105 22
90 115 105 23
100 130 105 24

L1 is the body length beyond the entry thread and L is the entry thread length, following the source drawing.

Custom Metric Threads — CNEx Configurations

The supplied specification lists the following non-standard metric threads for CNEx customization. Availability and the applicable certificate scope must be matched to the selected configuration; this list does not extend these custom threads to every approval listed above.

Nominal thread diameter Available pitch (mm)
M12 1.5
M18 1.5
M22 1.5
M24 1.5
M25 2.0
M27 1.5 / 2.0
M28 1.5 / 2.0
M30 2.0
M33 1.5 / 2.0
M36 1.5 / 2.0
M40 2.0
M42 1.5 / 2.0
M48 2.0
M50 2.0
M60 1.5
M64 2.0
M75 2.0
M80 2.0
M85 3.0
M90 2.0
M100 2.0

Custom-thread cable ranges and external dimensions are not separately supplied. Where two pitches are listed, specify the required pitch.

Accessories and Ordering

Specify BDM-21 size, body material, thread standard, diameter and pitch, inner and outer sheath diameters, armor thickness and required operating temperature configuration. Include the required Ex application and approval scope, particularly for custom threads.

The inner barrier uses compatible putty compound. Although A/B putty compound is listed as an optional accessory, the barrier sealing component is required for the barrier configuration; specify its supply if it is not already available separately.

Nylon washers and locknuts are listed as standard except for NPT versions. Earth tags, PVC shrouds, serrated washers and red fibre washers are optional. Compound formulation, curing procedure and installation torque should follow the documentation for the delivered configuration.