Aluminum Alloy Waterproof Breathable Vent Valves
Aluminum Alloy Waterproof Breathable Vent Valves provide a threaded vent fitting for enclosure openings.
- 25 catalog configurations combining metric, G and NPT threads.
- Size-specific minimum air permeability ≥200 to ≥8500 mL/min at 70 mbar.
- Catalog temperature resistance: −40 to +150 °C.
- Catalog-listed protection level: IP68.
Обзор
Aluminum Alloy Waterproof Breathable Vent Valves provide a vented threaded fitting for enclosure openings. The catalog lists metric, G and NPT configurations, with airflow and dimensions for each size. Minimum air permeability is referenced to 70 mbar.
Характеристики
- Three thread families in one series, with individual dimension and airflow tables.
- Aluminum alloy construction with finish options listed by specification.
- Catalog-listed IP68 protection level; immersion depth and test duration are not supplied.
Технические характеристики
| Параметр | Catalog specification |
|---|---|
| Material | Aluminum alloy |
| Air permeability test pressure | 70 mbar |
| Catalog-listed protection level | IP68 |
| Temperature resistance | −40 to +150 °C |
| Moisture permeability | >5000 g/(m²·24 h), series-level catalog reference |
| Static water pressure resistance | >100 mbar for 30 minutes, catalog reference |
Models and Dimensions
All dimensions are in mm. Air permeability figures are minimums in mL/min at 70 mbar. H is total length and GL is thread length. AG is the wrench dimension for the regular version; the slotted version lists a 10 mm head outside diameter instead.
Metric Specifications
| Catalog specification | Listed finish | Minimum air permeability | H | Thread Ø | GL | AG |
|---|---|---|---|---|---|---|
| M5×0.8 | Sandblasted and oxidized | ≥200 | 10 | 5 | 4 | 8 |
| M6×1 | Sandblasted and oxidized | ≥200 | 12 | 6 | 6 | 8 |
| M8×1.25 | Oxidized | ≥300 | 15.5 | 8 | 7 | 12 |
| M10×1.5 | Sandblasted and oxidized | ≥600 | 17 | 10 | 8 | 14 |
| M10×1 | Sandblasted and oxidized | ≥600 | 17 | 10 | 8 | 14 |
| M12×1.5 | Sandblasted and oxidized / black oxide | ≥800 | 19 | 12 | 10 | 16 |
| M12×1.5 | Bright finish | ≥800 | 19 | 12 | 10 | 16 |
| M14×1.5 | Oxidized | ≥1200 | 21 | 14 | 10 | 19 |
| M16×1.5L | Sandblasted and oxidized / black oxide | ≥1500 | 19 | 16 | 10 | 20 |
| M16×1.5 | Sandblasted and oxidized | ≥1500 | 21 | 16 | 10 | 20 |
| M18×1.5-10 | Sandblasted and oxidized | ≥1700 | 19 | 18 | 10 | 22 |
| M20×1.5 | Sandblasted and oxidized | ≥1500 | 19 | 20 | 10 | 22 |
| M25×1.5 | Oxidized | ≥2300 | 21 | 25 | 8 | 30 |
| M32×1.5 | Sandblasted and oxidized | ≥4500 | 27 | 32 | 15 | 36 |
| M40×1.5 | Oxidized | ≥8500 | 29 | 40 | 15 | 45 |
G Specifications
| Catalog specification | Listed finish | Minimum air permeability | H | Thread Ø | GL | AG |
|---|---|---|---|---|---|---|
| G1/8 | Sandblasted and oxidized | ≥600 | 17 | 9.8 | 8 | 14 |
| G1/4 | Sandblasted and oxidized | ≥800 | 19 | 13.2 | 10 | 16 |
| G3/8 | Sandblasted and oxidized | ≥1500 | 19 | 16.8 | 10 | 21 |
| G1/2 | Sandblasted and oxidized | ≥1500 | 19 | 21 | 10 | 22 |
| G3/4 | Sandblasted and oxidized | ≥2500 | 22 | 26.5 | 10 | 30 |
NPT Specifications
NPT thread diameters are omitted because the source repeats the G-table diameters. Confirm the NPT dimensions for the required configuration.
| Catalog specification | Listed finish | Minimum air permeability | H | Thread Ø | GL | AG |
|---|---|---|---|---|---|---|
| NPT1/8 | Sandblasted and oxidized | ≥600 | 17 | — | 8 | 14 |
| NPT1/4 | Sandblasted and oxidized | ≥800 | 19 | — | 10 | 16 |
| NPT3/8 | Sandblasted and oxidized | ≥1500 | 19 | — | 10 | 21 |
| NPT1/2 | Sandblasted and oxidized | ≥1500 | 19 | — | 10 | 22 |
| NPT3/4 | Sandblasted and oxidized | ≥2500 | 22 | — | 10 | 30 |
Руководство по выбору
Match the thread form and pitch, required airflow, finish and available space to the table. The two M12×1.5 entries differ by finish. Retain the printed M16×1.5L designation when requesting the 19 mm H configuration; the M16×1.5 entry lists H 21 mm.
Размеры