YOCL

FNY / FDNYD Nylon Female Terminals

FNY single-crimp and FDNYD double-crimp nylon female terminals are combined in one listing with 22 matched model pairs for 0.5–6 mm² conductors.

  • Brass contacts with nylon insulating sleeves.
  • Red, blue and yellow conductor groups with separate Imax values.
  • Choose by model, mating NEMA tab size and body dimensions.
Запрос по этому продукту

Обзор

FNY / FDNYD Nylon Female Terminals are insulated brass receptacle terminals for matching flat male tabs. The supplied catalog pairs FNY single-crimp and FDNYD double-crimp constructions across 22 corresponding model rows, covering three conductor groups from 0.5 to 6 mm².

Характеристики

  • Two crimp constructions: FNY and FDNYD are listed as corresponding single- and double-crimp models. The catalog describes a copper tube with sleeve for the FDNYD double-crimp version.
  • Mating tab selection: each row gives the matching NEMA tab thickness and width in millimeters.
  • Group-based specifications: conductor range, Imax, sleeve dimensions and insulation color differ by group.

Технические характеристики

Parameter Specification
Product type Nylon-insulated female terminal
Models 22 FNY single-crimp and 22 FDNYD double-crimp codes
Contact material Brass
Insulating sleeve Nylon, as named in the source heading
Voltage stated in catalog 400 V
Temperature stated in catalog 105°C
NEMA tab size 0.5 × 2.8 to 1.2 × 9.4 mm, according to model
Dimension units mm

Imax is the catalog’s maximum-current label. It applies to the respective conductor group, with no test or installation conditions supplied.

Group Color Conductor range AWG Imax E (mm) D (mm) d (mm)
1.25 Red 0.5–1.5 mm² 22–16 10 A 11.0 3.8 1.7
2 Blue 1.5–2.5 mm² 16–14 15 A 11.0 4.3 2.3
5.5 Yellow 4–6 mm² 12–10 24 A 13.0 5.7 3.4

Размеры

NEMA tab size is given as thickness × width. The source uses L1 for the FNY drawing and L2 for the FDNYD drawing; their printed numerical values are equal for each matched pair. D, d and E are shared group values and are repeated here for direct model comparison. All dimensions are in millimeters.

FNY single-crimp model FDNYD double-crimp model Color NEMA tab (mm) Material thickness (mm) B (mm) D (mm) d (mm) L1 (mm) L2 (mm) E (mm)
FNY 1.25-110(5) FDNYD 1.25-110(5) Red 0.5 × 2.8 0.3 3.3 3.8 1.7 19.5 19.5 11.0
FNY 1.25-110(8) FDNYD 1.25-110(8) Red 0.8 × 2.8 0.3 3.3 3.8 1.7 19.5 19.5 11.0
FNY 1.25-187(5) FDNYD 1.25-187(5) Red 0.5 × 4.75 0.35 5.0 3.8 1.7 20.0 20.0 11.0
FNY 1.25-187(8) FDNYD 1.25-187(8) Red 0.8 × 4.75 0.35 5.0 3.8 1.7 20.0 20.0 11.0
FNY 1.25-205 FDNYD 1.25-205 Red 0.5 × 5.2 0.35 5.7 3.8 1.7 20.0 20.0 11.0
FNY 1.25-250 FDNYD 1.25-250 Red 0.8 × 6.35 0.4 6.6 3.8 1.7 20.8 20.8 11.0
FNY 1.25-312 FDNYD 1.25-312 Red 0.8 × 8.0 0.4 8.2 3.8 1.7 24.0 24.0 11.0
FNY 2-110(5) FDNYD 2-110(5) Blue 0.5 × 2.8 0.3 3.3 4.3 2.3 19.5 19.5 11.0
FNY 2-110(8) FDNYD 2-110(8) Blue 0.8 × 2.8 0.3 3.3 4.3 2.3 19.5 19.5 11.0
FNY 2-187(5) FDNYD 2-187(5) Blue 0.5 × 4.75 0.35 5.0 4.3 2.3 20.0 20.0 11.0
FNY 2-187(8) FDNYD 2-187(8) Blue 0.8 × 4.75 0.35 5.0 4.3 2.3 20.0 20.0 11.0
FNY 2-205 FDNYD 2-205 Blue 0.5 × 5.2 0.35 5.7 4.3 2.3 20.0 20.0 11.0
FNY 2-250 FDNYD 2-250 Blue 0.8 × 6.35 0.4 6.6 4.3 2.3 20.0 20.0 11.0
FNY 2-312 FDNYD 2-312 Blue 0.8 × 8.0 0.4 8.2 4.3 2.3 24.7 24.7 11.0
FNY 2-375 FDNYD 2-375 Blue 1.2 × 9.4 0.5 9.9 4.3 2.3 28.6 28.6 11.0
FNY 5.5-110 × 5 FDNYD 5.5-110 × 5 Yellow 0.5 × 2.8 0.35 3.3 5.7 3.4 22.0 22.0 13.0
FNY 5.5-110 × 8 FDNYD 5.5-110 × 8 Yellow 0.8 × 2.8 0.35 3.3 5.7 3.4 22.0 22.0 13.0
FNY 5.5-187 × 5 FDNYD 5.5-187 × 5 Yellow 0.5 × 4.75 0.4 5.0 5.7 3.4 23.0 23.0 13.0
FNY 5.5-187 × 8 FDNYD 5.5-187 × 8 Yellow 0.8 × 4.75 0.4 5.0 5.7 3.4 23.0 23.0 13.0
FNY 5.5-250 FDNYD 5.5-250 Yellow 0.8 × 6.35 0.4 6.6 5.7 3.4 24.4 24.4 13.0
FNY 5.5-312 FDNYD 5.5-312 Yellow 0.8 × 8.0 0.5 8.2 5.7 3.4 28.3 28.3 13.0
FNY 5.5-375 FDNYD 5.5-375 Yellow 1.2 × 9.4 0.5 9.9 5.7 3.4 30.6 30.6 13.0

FNY / FDNYD Nylon Female Terminals dimension drawing

FNY / FDNYD Nylon Female Terminals dimension drawing

Руководство по выбору

Select the conductor group and FNY or FDNYD crimp construction, then match the NEMA tab size to the intended mating tab. Check B, D, d, L1/L2 and E against available space and quote the exact model code when ordering.