YOCL

Nickel-Plated Brass Waterproof Breathable Cable Gland

Nickel-plated brass cable gland combining cable entry sealing with a breathable design.

  • Specified ingress protection: IP68.
  • 10 configurations with model-specific cable ranges and metric threads.
  • Minimum airflow requirements: 100–500 mL/min across the listed configurations, measured at 70 mbar.
  • Nylon PA clamping insert; NBR and EPDM sealing materials listed.
  • Ambient temperature −40 °C to +100 °C; short-term exposure up to +120 °C.
Запрос по этому продукту

Обзор

The YOCL ELECTRIC Nickel-Plated Brass Waterproof Breathable Cable Gland combines cable entry sealing with a breathable design. The supplied size table specifies cable diameter ranges, minimum airflow at a pressure differential of 70 mbar, metric entry threads and installation dimensions.

The body is nickel-plated brass. Select the configuration using its cable range, airflow requirement, thread length and wrench size.

Характеристики

  • Breathable cable entry: Model-specific minimum airflow values stated at 70 mbar.
  • IP68 protection: As specified in the supplied product data.
  • Material selection: Nickel-plated brass body.
  • Metric thread configurations: Cable clamping ranges and dimensions listed separately below.

Technical Specifications

Parameter Specification
Product type Waterproof breathable cable gland
Body material Nickel-plated brass
Colour / finish Nickel-plated finish
Ingress protection IP68
Airflow test pressure differential 70 mbar
Airflow specification Minimum airflow varies by configuration; see table below
Entry thread Metric, 1.5 mm pitch
Clamping insert Nylon PA
Listed sealing materials Nitrile rubber (NBR); EPDM
Ambient temperature −40 °C to +100 °C
Short-term temperature Up to +120 °C

IP68 immersion depth and duration are not provided in the supplied data.
The source lists NBR and EPDM without assigning them to individual configurations. The allowed duration of short-term +120 °C exposure is not stated.

Dimension

Cable Range and Airflow

All cable dimensions are in millimetres. Airflow is the minimum value at 70 mbar.

Configuration Entry thread Cable range (mm) Minimum airflow (mL/min at 70 mbar)
M10×1.5/3–7 M10×1.5 3–7 ≥100
M12×1.5/3–7 M12×1.5 3–7 ≥100
M12×1.5/4–8 M12×1.5 4–8 ≥100
M12×1.5/4–8 M12×1.5 4–8 ≥200
M16×1.5/4–8 M16×1.5 4–8 ≥200
M16×1.5/5–10 M16×1.5 5–10 ≥300
M18×1.5/5–10 M18×1.5 5–10 ≥300
M20×1.5/6–12 M20×1.5 6–12 ≥300
M22×1.5/10–14 M22×1.5 10–14 ≥500
M25×1.5/10–16 M25×1.5 10–16 ≥500

Installation Dimensions

AG is the nominal metric thread diameter; GL is the entry thread length. Wrench sizes are in millimetres.

Configuration Minimum airflow (mL/min at 70 mbar) Thread diameter AG (mm) Thread length GL (mm) Wrench size (mm)
M10×1.5/3–7 ≥100 10 6 14
M12×1.5/3–7 ≥100 12 6 14
M12×1.5/4–8 ≥100 12 7 17
M12×1.5/4–8 ≥200 12 7.5 18
M16×1.5/4–8 ≥200 16 7.5 18
M16×1.5/5–10 ≥300 16 7.5 22
M18×1.5/5–10 ≥300 18 8 22
M20×1.5/6–12 ≥300 20 8 22
M22×1.5/10–14 ≥500 22 8 27
M25×1.5/10–16 ≥500 25 9 27

M12×1.5/4–8 has two configurations: ≥100 mL/min with GL 7 mm and wrench size 17 mm; ≥200 mL/min with GL 7.5 mm and wrench size 18 mm. These are separate entries, not duplicate rows.

Overall body height H is shown in the reference drawing but is not tabulated; no H values are assigned here.

Ordering Information

Specify the body material, metric thread size, cable diameter range and required minimum airflow. Check the entry thread length and available wrench clearance against the enclosure.
Include the required sealing material and temperature conditions in the order.
For M12×1.5/4–8, include the airflow requirement and GL to distinguish the two configurations.

Детали проекта

Поля, отмеченные *, обязательны для заполнения.

Your details will be used to respond to your enquiry. Privacy notice