YOCL

Клеммные колодки на DIN-рейку с пружинным зажимом SJ DIN

YOCL ELECTRIC SJ Cage Spring DIN Rail Terminal Blocks organize wire connections in control and distribution panels.

  • 13 SJ models with rated cross-sections from 1.5 to 16 mm².
  • Cage spring connections and TH35-7.5 / TH35-15 DIN rail mounting.
  • Eight models with specified ratings of 500 or 800 V and 17.5–90 A.
  • Model-specific rigid and flexible conductor ranges, stripping lengths and thicknesses for selection.
Запрос по этому продукту

Обзор

YOCL ELECTRIC SJ Cage Spring DIN Rail Terminal Blocks provide connection points for control and distribution panel wiring. The series includes 13 models and mounts on TH35-7.5 or TH35-15 DIN rails.

Select each model using its rated cross-section and the conductor data listed below.

Характеристики

  • Cage spring connection mechanism.
  • Two compatible DIN rail profiles: TH35-7.5 and TH35-15.
  • Model-specific conductor ranges and thicknesses for panel planning.
  • Accessory types include end plates, partition plates, plug-in bridges and marking strips.

Technical Specifications

Models with Electrical Ratings

Model Rated Voltage Rated Current Rated Cross-Section Rigid Wire Range Flexible Wire Range Stripping Length Thickness
SJ-1.5 500 V 17.5 A 1.5 mm² 0.14–1.5 mm² 0.14–1.5 mm² 10 mm 4.2 mm
SJ-2.5 800 V 24 A 2.5 mm² 0.2–4 mm² 0.2–2.5 mm² 10 mm 5.2 mm
SJ-4 800 V 32 A 4 mm² 0.2–6 mm² 0.2–4 mm² 10 mm 6.2 mm
SJ-6 800 V 41 A 6 mm² 0.5–10 mm² 0.5–6 mm² 12 mm 8.2 mm
SJ-10 800 V 57 A 10 mm² 1.5–16 mm² 1.5–10 mm² 16 mm 10.2 mm
SJ-16 800 V 90 A 16 mm² 2.5–25 mm² 2.5–16 mm² 18 mm 12.2 mm
SJ-2.5/1×2 800 V 24 A 2.5 mm² 0.2–4 mm² 0.2–2.5 mm² 10 mm 5.2 mm
SJ-2.5/2×2 800 V 24 A 2.5 mm² 0.2–4 mm² 0.2–2.5 mm² 10 mm 5.2 mm

JD Model Cross-Sections and Thicknesses

Model Rated Cross-Section Thickness
SJ-2.5JD 2.5 mm² 5.2 mm
SJ-4JD 4 mm² 6.2 mm
SJ-6JD 6 mm² 8.2 mm
SJ-10JD 10 mm² 10.2 mm
SJ-16JD 16 mm² 12.2 mm

JD Model Conductor Ranges

Model Rigid Wire Range Flexible Wire Range
SJ-2.5JD 0.2–4 mm² 0.2–2.5 mm²
SJ-4JD 0.2–6 mm² 0.2–4 mm²
SJ-6JD 0.5–10 mm² 0.5–6 mm²
SJ-16JD 2.5–25 mm² 2.5–16 mm²

JD Model Stripping Lengths

Model Stripping Length
SJ-2.5JD 10 mm
SJ-4JD 10 mm
SJ-6JD 12 mm

Mounting

Parameter Specification
Connection method Cage spring
Mounting rail TH35-7.5 or TH35-15

Selection Guide

Match the model, conductor type and cross-section to the same table row. Select accessories for the chosen terminal model. For inquiries, provide the model, quantity and accessory requirements.

Применение

  • Factory automation and control panels.
  • Power distribution panels.
  • HVAC equipment and building management systems.

Детали проекта

Поля, отмеченные *, обязательны для заполнения.

Your details will be used to respond to your enquiry. Privacy notice