YOCL

BDM-5 Explosion-Proof Armored Cable Gland

BDM-5 single-seal armored cable gland with compound barrier flameproof sealing for industrial hazardous-area cable entry.

  • Brass, nickel-plated brass, SS304 or SS316 body options.
  • IP66 protection; operating temperature −40 °C to +60 °C.
  • Reversible armor rings and a multiple-layer seal.
  • 22 sizes with metric threads from M16×1.5 to M110×1.5.
  • Non-standard metric thread diameters and pitches available on request.
Bu ürün hakkında bilgi alın

Genel Bakış

The YOCL ELECTRIC BDM-5 Explosion-Proof Armored Cable Gland is a single-seal type for armored cable, with compound barrier flameproof sealing. Its multiple-layer seal accommodates the cable ranges listed in the size table, while reversible armor rings support different armored cable constructions.

Body options include brass, nickel-plated brass, SS304 and SS316. The supplied specification lists Ex db, Ex eb and Ex tb marking for hazardous-area applications in Zones 1, 2, 21 and 22.

Özellikler

  • Compound barrier sealing: Flameproof barrier construction as described in the supplied specification.
  • Multiple-layer seal: Cable sizes are selected using the model-specific inner and outer sheath dimensions.
  • Reversible armor rings: Accommodate different armored cable constructions.
  • Body material options: Brass, nickel-plated brass, SS304 and SS316.
  • Thread selection: Standard metric entries and listed NPT/G nominal sizes, with non-standard metric thread options available on request.

Teknik Özellikler

Parameter Specification
Model BDM-5
Type Single seal type for armored cable
Sealing construction Compound barrier flameproof sealing; multiple-layer seal
Armor retention Reversible armor rings
Operating temperature −40 °C to +60 °C
Supplied Ex marking Ex db IIC Gb; Ex eb IIC Gb; Ex tb IIIC Db
Ingress protection IP66
Body material options Brass; nickel-plated brass; SS304; SS316
Listed hazardous area applications Zone 1; Zone 2; Zone 21; Zone 22
Approvals stated in supplied specification CNEx; CCC; EAC (CUTR)
Standards listed in supplied specification GB 3836.1; GB 3836.2; GB 3836.3; GB 12476.1; GB 12476.5
Standard metric thread pitch 1.5 mm, as listed in the size table
Non-standard metric threads Diameters and pitches listed below; available on request

The supplied approval statements do not include certificate numbers or the editions of the listed standards.

Boyut

Cable Selection Data

Dimensions are in millimetres, except the NPT/G nominal thread sizes in inches. A and B retain the supplied table’s inner sheath and outer sheath labels.

Size Metric entry thread AG NPT/G nominal size (inch) Inner sheath A (mm) Outer sheath B (mm)
16 M16×1.5 — 8 7–15
20B M20×1.5 1/2 10 7–15
20C M20×1.5 1/2 15 10–20
25B M25×1.5 3/4 15 10–20
25C M25×1.5 3/4 20 12–26.5
32B M32×1.5 1 20 12–26.6
32C M32×1.5 1 27 19–33
40B M40×1.5 1-1/4 27 19–33
40C M40×1.5 1-1/4 31 22–40
50B M50×1.5 1-1/2 31 22–40
50C M50×1.5 1-1/2 41 29–50
63B M63×1.5 2 41 29–50
63C M63×1.5 2 55 35–63
75B M75×1.5 2-1/2 55 35–63
75C M75×1.5 2-1/2 65 45–76
85B M85×1.5 3 65 45–76
85C M85×1.5 3 65 61–90
90B M90×1.5 3-1/2 65 45–76
90C M90×1.5 3-1/2 75 61–90
100B M100×1.5 4 75 61–90
100C M100×1.5 4 90 61–103
110 M110×1.5 4 90 61–103

A is a single dimension in the supplied table, rather than a stated clamping range. The drawing shows A at the entry-side internal opening. A dash indicates that no NPT/G thread size was supplied for that row; specify NPT or BSP (G) explicitly when ordering.

External Dimensions

Size Maximum size D (mm) Body length L1 (mm) Entry thread length L (mm)
16 27 53 15
20B 27 53 15
20C 33 53 15
25B 33 53 15
25C 39 54 15
32B 39 54 17
32C 50 54 17
40B 50 54 19
40C 60 65 19
50B 60 65 19
50C 73 68 19
63B 73 68 20
63C 89 79 20
75B 89 79 22
75C 99 79 22
85B 99 79 22
85C 99 79 22
90B 99 79 23
90C 115 86 23
100B 115 86 24
100C 129 86 24
110 129 86 24

L1 is the body length beyond the entry thread; L is the entry thread length, following the source drawing.

Custom Metric Threads

The following non-standard thread diameters and pitches are available on request. Where more than one pitch is listed, specify one pitch for the order. The standard size table does not assign separate cable ranges or external dimensions to these custom threads.

Nominal thread diameter Available pitch (mm)
M18 1.5
M22 1.5
M24 1.5
M27 1.5 / 2.0
M28 1.5
M30 1.5 / 2.0
M36 1.5 / 2.0
M40 2.0
M48 2.0
M50 2.0
M60 1.5 / 2.0
M63 2.0
M64 1.5 / 2.0
M72 1.5 / 2.0
M75 2.0
M80 1.5 / 2.0
M85 2.0 / 3.0
M90 2.0
M100 2.0
M110 2.0
M115 1.5
M120 1.5 / 2.0

Sipariş Bilgileri

Specify BDM-5 size, body material, entry thread standard, diameter and pitch, cable inner and outer sheath dimensions, and armor construction. For custom threads, include the enclosure entry specification and required thread engagement.

Specify the compatible compound barrier configuration with the order. Compound formulation, curing requirements and accessory supply are not defined in the supplied data and should follow the documentation for the delivered configuration.

Proje detayları

* ile işaretlenmiş alanlar zorunludur.

Sorunuza yanıt vermek için bilgileriniz kullanılacaktır. Gizlilik bildirimi