YOCL

BDM-21-II Flameproof Ex d Barrier Cable Gland for Conduit

BDM-21-II single compression armored barrier cable gland with a female connection for externally threaded steel pipe or flexible conduit.

  • Outer clamping seal and inner putty compound barrier.
  • Brass, nickel-plated brass, SS304 or SS316 body options.
  • IP66, IP67 and IP68 (1 m, 1 h).
  • 20 sizes with separately specified entry AG and conduit AG(F) threads.
  • G-thread options for Ex e and Ex t only.
Hỏi về sản phẩm này

Tổng quan

The YOCL ELECTRIC BDM-21-II Flameproof Ex d Barrier Cable Gland for Conduit uses a single compression armored construction with an outer clamping seal and an inner putty compound barrier. It includes a female threaded conduit connection. The hexagonal metal body is available in brass, nickel-plated brass, SS304 and SS316.

The supplied specification lists hazardous-area applications in Zones 1, 2, 21 and 22. Metric and NPT options are listed for the Ex applications described below; G-thread options are restricted to increased safety and dust-protection applications.

The conduit end accepts an externally threaded steel pipe or flexible conduit while the gland retains the armored cable.

Tính năng

  • Compound barrier construction: Inner putty compound sealing with an outer clamping seal.
  • Hexagonal body: Defined wrench flats for handling during assembly.
  • Armored cable selection: Model-specific inner sheath, outer sheath and armor thickness data.
  • Body material options: Brass, nickel-plated brass, SS304 and SS316.
  • Thread options: Standard metric sizes and NPT/G nominal sizes, with separately listed CNEx custom metric thread options.

Thông số kỹ thuật

Tham số Thông số kỹ thuật
Mẫu BDM-21-II
Type Single compression armored barrier type for conduit connection
Sealing Outer clamping seal; inner putty compound barrier
Body material options Brass; nickel-plated brass; SS304; SS316
Sealing material options Silicone rubber; neoprene; PTFE (Teflon); PA6
Operating temperature options −40 °C to +100 °C / −60 °C to +80 °C, depending on configuration
Supplied Ex marking Ex db IIC Gb; Ex eb IIC Gb; Ex tb IIIC Db, subject to thread configuration
Ingress protection IP66; IP67; IP68 (1 m, 1 h)
Listed hazardous area applications Zone 1; Zone 2; Zone 21; Zone 22
Thread options Metric; NPT; BSP (G)
G-thread application restriction Ex e and Ex t only; not listed for Ex d
Stated flammability classification UL 94 V-0
Approvals stated in supplied specification IECEx; ATEX; EAC (CUTR); CNEx; CCC
Standards listed in supplied specification IEC/EN 60079-0; IEC/EN 60079-1; IEC/EN 60079-31; IEC/EN 60529; GB 3836
Standard accessories Nylon washer and locknut
Optional accessories Earth tag; PVC shroud; serrated washer; red fibre washer; A/B putty compound

Temperature limits and approval scope depend on the selected configuration. The supplied data does not map the temperature options to sealing materials or provide certificate numbers. UL 94 V-0 is the stated flammability classification; the specific material scope is not identified.

Kích thước

Cable Selection and Equipment Entry

Dimensions are in millimetres, except nominal inch thread sizes. AG is the equipment-side entry thread.

Size Metric AG NPT/G AG (inch) Inner sheath A (mm) Outer sheath B (mm) Armor range h (mm)
16A M16×1.5 3/8 <8 5.5–12 0.3–1.0
16B M16×1.5 3/8 <8 9.5–16 0.3–1.0
20A M20×1.5 1/2 <11 5.5–12 0.3–1.0
20B M20×1.5 1/2 <11 9.5–16 0.3–1.0
20C M20×1.5 1/2 <15 12.5–20.5 0.3–1.0
25B M25×1.5 3/4 <15 12.5–20.5 0.3–1.0
25C M25×1.5 3/4 <21 17–26 0.4–1.2
32B M32×1.5 1 <21 17–26 0.4–1.2
32C M32×1.5 1 <27 22–33 0.4–1.4
40B M40×1.5 1-1/4 <27 22–33 0.6–1.9
40C M40×1.5 1-1/4 <33 28–41 0.6–2.2
50B M50×1.5 1-1/2 <33 28–41 0.8–2.3
50C M50×1.5 1-1/2 <42 36–52.6 0.8–2.3
63B M63×1.5 2 <42 36–52.6 0.9–2.4
63C M63×1.5 2 <54.5 46–64 0.9–2.4
75B M75×1.5 2-1/2 <54.5 46–64 0.9–2.4
75C M75×1.5 2-1/2 <66 57–78 0.9–2.4
80 M80×1.5 3 <66 57–78 0.9–2.4
90 M90×1.5 3 <75 68–88 0.9–2.8
100 M100×1.5 4 <90 83–103 0.9–2.8

Female Conduit Connection and Dimensions

AG(F) is the female connection for an externally threaded conduit. It can differ from the equipment entry thread AG. Specify the thread standard on both ends; the nominal NPT/G values do not make these standards interchangeable.

Size Metric AG(F) G/NPT AG(F) (inch) Maximum size D (mm) Body length L1 (mm) Entry thread length L (mm)
16A M16×1.5 3/8 29 75 16
16B M16×1.5 3/8 29 75 16
20A M20×1.5 1/2 29 77 16
20B M20×1.5 1/2 29 77 16
20C M25×1.5 3/4 37 78 16
25B M25×1.5 3/4 37 78 16
25C M32×1.5 1 44 90 16
32B M32×1.5 1 44 90 18
32C M40×1.5 1-1/4 55 97 18
40B M40×1.5 1-1/4 55 97 18
40C M50×1.5 1-1/2 67 103 18
50B M50×1.5 1-1/2 67 103 20
50C M63×1.5 2 73 111 20
63B M63×1.5 2 73 111 21
63C M75×1.5 2-1/2 89 136 21
75B M75×1.5 2-1/2 89 136 22
75C M90×2 3-1/2 105 146 22
80 M90×2 3-1/2 105 146 22
90 M115×2 4 115 155 23
100 M120×2 4-1/2 130 155 24

L1 is the body length beyond the entry thread; L is the entry thread length, following the source drawing.

Custom Metric Threads — CNEx Configurations

The supplied specification lists the following non-standard metric threads for CNEx customization. Availability and the applicable certificate scope must be matched to the selected configuration; this list does not extend these custom threads to every approval listed above.

Nominal thread diameter Available pitch (mm)
M12 1.5
M18 1.5
M22 1.5
M24 1.5
M25 2.0
M27 1.5 / 2.0
M28 1.5 / 2.0
M30 2.0
M33 1.5 / 2.0
M36 1.5 / 2.0
M40 2.0
M42 1.5 / 2.0
M48 2.0
M50 2.0
M60 1.5
M64 2.0
M75 2.0
M80 2.0
M85 3.0
M90 2.0
M100 2.0

Custom-thread cable ranges and external dimensions are not separately supplied. Where two pitches are listed, specify the required pitch.

Accessories and Ordering

Specify BDM-21-II size, body material, both entry AG and female conduit AG(F) thread standards and sizes, cable sheath diameters, armor thickness and temperature configuration. G-thread options are listed for Ex e and Ex t only.

The barrier uses compatible inner putty compound. A/B compound is listed as an optional accessory, so specify its supply if it is not already available separately. Standard accessories are a nylon washer and locknut. Optional accessories include an earth tag, PVC shroud, serrated washer and red fibre washer.

Compound formulation, curing requirements and installation torque should follow the documentation for the delivered configuration.

Chi tiết dự án

Các trường có dấu * là bắt buộc.

Thông tin chi tiết của bạn sẽ được sử dụng để phản hồi yêu cầu của bạn. Thông báo về quyền riêng tư