YOCL

HSNE-F 2:1 Flame-Retardant EV Busbar Heat Shrink Tubing

YOCL Electric HSNE-F provides flame-retardant single-wall insulation for EV busbars, copper bars and electrical connections.

  • Radiation cross-linked polyolefin with a 2:1 shrink ratio.
  • VW-1 flame rating; operating range -55°C to +125°C.
  • Initial shrink temperature ≥85°C; full shrink temperature ≥125°C.
  • Eighteen sizes from 10/5 mm to 50/25 mm, with packing lengths specified by size.
  • Standard orange color; custom colors available.
استفسر عن هذا المنتج

نظرة عامة

YOCL كهربائي HSNE-F 2:1 Flame-Retardant EV Busbar Heat Shrink Tubing provides electrical insulation and surface protection for new energy vehicle busbars, copper bars and electrical connections. The series is made from radiation cross-linked polyolefin with a single-wall construction.

Its 2:1 shrink ratio allows the tubing to recover around conductive components and connection areas. Eighteen sizes cover nominal diameters from 10/5 mm to 50/25 mm. HSNE-F has a VW-1 flame rating, an operating range of -55°C to +125°C and a standard orange color.

الميزات

  • EV busbar insulation: Suits copper bars, laminated busbars and battery electrical connections.
  • 2:1 single-wall construction: Forms a close-fitting insulating cover around the component.
  • VW-1 flame performance: Specified with ASTM D2671 as the test method.
  • Defined electrical properties: Withstand-voltage, breakdown-strength and resistivity specifications are listed below.
  • Standard orange color: Supports visual identification in vehicle electrical systems; custom colors are available.
  • Eighteen size options: Supplied diameters, recovered walls, packing lengths and application ranges are listed by size.

المواصفات الفنية

Parameter Specification
Brand YOCL كهربائي
Series HSNE-F
Product type Flame-retardant single-wall heat shrink tubing
Primary application New energy vehicle busbars and electrical connections
Material Radiation cross-linked polyolefin
الإنشاء Single wall
Shrink ratio 2:1
Operating temperature -55°C to +125°C
Initial shrink temperature ≥85°C
Full shrink temperature ≥125°C
Standard color Orange
Custom colors Available
Environmental standard RoHS
Nominal size range 10/5 mm to 50/25 mm
Standard packing 100 m, 50 m or 25 m, depending on size
Number of listed sizes 18

Mechanical and Flame Performance

Property Specification Test method or condition
Tensile strength ≥10.4 MPa ASTM D2671
Elongation at break ≥200% ASTM D2671
Tensile strength after aging ≥7.3 MPa 158°C for 168 hours
Elongation after aging ≥100% 158°C for 168 hours
Axial change -5% to +5% ASTM D2671
Flame retardancy VW-1 ASTM D2671

The 158°C exposure is an aging test condition. The stated operating temperature range is -55°C to +125°C.

Electrical Performance

Property Specification Test method
Withstand voltage (600 V) 2500 V for 1 minute; no breakdown UL224
Breakdown strength ≥15 kV/mm ASTM D149
Volume resistivity ≥10¹⁴ Ω·cm IEC 60093

الأبعاد

Nominal size (mm) Supplied I.D. (mm) Max. I.D. after recovery (mm) Wall thickness after recovery (mm) Standard packing (m) Application range (mm)
10/5 10.5 ± 0.30 ≤5.00 0.56 ± 0.10 100 5.3–10.1
11/5.5 11.5 ± 0.30 ≤5.50 0.56 ± 0.10 100 5.8–11.1
12/6 12.5 ± 0.30 ≤6.00 0.56 ± 0.10 100 6.3–12.1
13/6.5 13.5 ± 0.30 ≤6.50 0.70 ± 0.10 100 6.8–13.1
14/7 14.5 ± 0.30 ≤7.00 0.70 ± 0.10 100 7.3–14.1
15/7.5 15.5 ± 0.40 ≤7.50 0.70 ± 0.10 100 7.8–15.1
16/8 16.5 ± 0.40 ≤8.00 0.70 ± 0.10 100 8.3–16.1
17/8.5 17.5 ± 0.40 ≤8.50 0.70 ± 0.10 100 8.8–17.1
18/9 19.0 ± 0.50 ≤9.00 0.70 ± 0.10 100 9.3–18.1
20/10 22.0 ± 0.50 ≤10.00 0.80 ± 0.15 100 10.5–21.0
22/11 24.0 ± 0.50 ≤11.00 0.80 ± 0.15 100 11.5–23.0
25/12.5 26.0 ± 0.50 ≤12.50 0.90 ± 0.15 50 13.0–25.0
28/14 29.0 ± 0.50 ≤14.00 0.90 ± 0.15 50 14.5–27.0
30/15 31.5 ± 1.00 ≤15.00 1.00 ± 0.15 50 17.0–29.0
35/17.5 36.5 ± 1.00 ≤17.50 1.00 ± 0.15 50 20.0–30.0
40/20 41.5 ± 1.00 ≤20.00 1.00 ± 0.15 50 22.0–35.0
45/22.5 46.5 ± 1.50 ≤22.50 1.00 ± 0.15 25 30–45
50/25 ≥50 ≤25.00 1.10 ± 0.15 25 28–45

I.D. means internal diameter. Diameters, wall thicknesses and application ranges are in millimetres; packing lengths are in metres. The ≤ values specify maximum recovered internal diameters. The 50/25 mm size has a minimum supplied I.D. of 50 mm.

دليل الاختيار

Use the application range for the selected size together with its supplied I.D., maximum recovered I.D. and recovered wall thickness. For example, the 20/10 mm option has a supplied I.D. of 22.0 ± 0.50 mm, a maximum recovered I.D. of 10.00 mm and a recovered wall thickness of 0.80 ± 0.15 mm. Its application range is 10.5–21.0 mm.

Check fit over the busbar, connection or component before choosing a size. Review the packing length for that row: 100 m for sizes 10/5 through 22/11, 50 m for 25/12.5 through 40/20, and 25 m for 45/22.5 and 50/25.

Specify the required color and quantity with the selected size. Orange is the standard color; other colors can be requested for project requirements.

التطبيقات

  • EV and hybrid vehicle battery systems.
  • Copper and laminated busbar insulation.
  • Battery electrical connections and conductive components.
  • Solder-joint protection against corrosion.
  • Electrical connection and component covering.

Installation Notes

  1. Measure the busbar, conductor or component requiring insulation.
  2. Select HSNE-F tubing using the application range and dimensional table.
  3. Cut the tubing to the required length and slide it into position.
  4. Apply controlled heat evenly around the tubing until it has uniformly recovered.
  5. Remove the heat source and allow the tubing to cool.
  6. Inspect the recovered tubing for complete and uniform coverage.

Ordering Information

Specify HSNE-F, the selected nominal size, required color and quantity when making an enquiry to YOCL Electric. Standard packing is 100 m, 50 m or 25 m according to the size table.

تفاصيل المشروع

الحقول المشار إليها بعلامة * مطلوبة.

سيتم استخدام تفاصيلك للرد على استفسارك. إشعار الخصوصية