FNY / FDNYD Nylon Steckverbinder Buchse
FNY single-crimp and FDNYD double-crimp nylon female terminals are combined in one listing with 22 matched model pairs for 0.5–6 mm² conductors.
- Brass contacts with nylon insulating sleeves.
- Red, blue and yellow conductor groups with separate Imax values.
- Choose by model, mating NEMA tab size and body dimensions.
Übersicht
FNY / FDNYD Nylon Female Terminals are insulated brass receptacle terminals for matching flat male tabs. The supplied catalog pairs FNY single-crimp and FDNYD double-crimp constructions across 22 corresponding model rows, covering three conductor groups from 0.5 to 6 mm².
Merkmale
- Two crimp constructions: FNY and FDNYD are listed as corresponding single- and double-crimp models. The catalog describes a copper tube with sleeve for the FDNYD double-crimp version.
- Mating tab selection: each row gives the matching NEMA tab thickness and width in millimeters.
- Group-based specifications: conductor range, Imax, sleeve dimensions and insulation color differ by group.
Technische Daten
| Parameter | Spezifikation |
|---|---|
| Product type | Nylon-insulated female terminal |
| Models | 22 FNY single-crimp and 22 FDNYD double-crimp codes |
| Contact material | Brass |
| Insulating sleeve | Nylon, as named in the source heading |
| Voltage stated in catalog | 400 V |
| Temperature stated in catalog | 105°C |
| NEMA tab size | 0.5 × 2.8 to 1.2 × 9.4 mm, according to model |
| Dimension units | mm |
Imax is the catalog’s maximum-current label. It applies to the respective conductor group, with no test or installation conditions supplied.
| Group | Color | Conductor range | AWG | Imax | E (mm) | D (mm) | d (mm) |
|---|---|---|---|---|---|---|---|
| 1.25 | Red | 0.5–1.5 mm² | 22–16 | 10 A | 11.0 | 3.8 | 1.7 |
| 2 | Blue | 1.5–2.5 mm² | 16–14 | 15 A | 11.0 | 4.3 | 2.3 |
| 5.5 | Yellow | 4–6 mm² | 12–10 | 24 A | 13.0 | 5.7 | 3.4 |
Abmessung
NEMA tab size is given as thickness × width. The source uses L1 for the FNY drawing and L2 for the FDNYD drawing; their printed numerical values are equal for each matched pair. D, d and E are shared group values and are repeated here for direct model comparison. All dimensions are in millimeters.
| FNY single-crimp model | FDNYD double-crimp model | Color | NEMA tab (mm) | Material thickness (mm) | B (mm) | D (mm) | d (mm) | L1 (mm) | L2 (mm) | E (mm) |
|---|---|---|---|---|---|---|---|---|---|---|
| FNY 1.25-110(5) | FDNYD 1.25-110(5) | Red | 0.5 × 2.8 | 0.3 | 3.3 | 3.8 | 1.7 | 19.5 | 19.5 | 11.0 |
| FNY 1.25-110(8) | FDNYD 1.25-110(8) | Red | 0.8 × 2.8 | 0.3 | 3.3 | 3.8 | 1.7 | 19.5 | 19.5 | 11.0 |
| FNY 1.25-187(5) | FDNYD 1.25-187(5) | Red | 0.5 × 4.75 | 0.35 | 5.0 | 3.8 | 1.7 | 20.0 | 20.0 | 11.0 |
| FNY 1.25-187(8) | FDNYD 1.25-187(8) | Red | 0.8 × 4.75 | 0.35 | 5.0 | 3.8 | 1.7 | 20.0 | 20.0 | 11.0 |
| FNY 1.25-205 | FDNYD 1.25-205 | Red | 0.5 × 5.2 | 0.35 | 5.7 | 3.8 | 1.7 | 20.0 | 20.0 | 11.0 |
| FNY 1.25-250 | FDNYD 1.25-250 | Red | 0.8 × 6.35 | 0.4 | 6.6 | 3.8 | 1.7 | 20.8 | 20.8 | 11.0 |
| FNY 1.25-312 | FDNYD 1.25-312 | Red | 0.8 × 8.0 | 0.4 | 8.2 | 3.8 | 1.7 | 24.0 | 24.0 | 11.0 |
| FNY 2-110(5) | FDNYD 2-110(5) | Blue | 0.5 × 2.8 | 0.3 | 3.3 | 4.3 | 2.3 | 19.5 | 19.5 | 11.0 |
| FNY 2-110(8) | FDNYD 2-110(8) | Blue | 0.8 × 2.8 | 0.3 | 3.3 | 4.3 | 2.3 | 19.5 | 19.5 | 11.0 |
| FNY 2-187(5) | FDNYD 2-187(5) | Blue | 0.5 × 4.75 | 0.35 | 5.0 | 4.3 | 2.3 | 20.0 | 20.0 | 11.0 |
| FNY 2-187(8) | FDNYD 2-187(8) | Blue | 0.8 × 4.75 | 0.35 | 5.0 | 4.3 | 2.3 | 20.0 | 20.0 | 11.0 |
| FNY 2-205 | FDNYD 2-205 | Blue | 0.5 × 5.2 | 0.35 | 5.7 | 4.3 | 2.3 | 20.0 | 20.0 | 11.0 |
| FNY 2-250 | FDNYD 2-250 | Blue | 0.8 × 6.35 | 0.4 | 6.6 | 4.3 | 2.3 | 20.0 | 20.0 | 11.0 |
| FNY 2-312 | FDNYD 2-312 | Blue | 0.8 × 8.0 | 0.4 | 8.2 | 4.3 | 2.3 | 24.7 | 24.7 | 11.0 |
| FNY 2-375 | FDNYD 2-375 | Blue | 1.2 × 9.4 | 0.5 | 9.9 | 4.3 | 2.3 | 28.6 | 28.6 | 11.0 |
| FNY 5.5-110 × 5 | FDNYD 5.5-110 × 5 | Yellow | 0.5 × 2.8 | 0.35 | 3.3 | 5.7 | 3.4 | 22.0 | 22.0 | 13.0 |
| FNY 5.5-110 × 8 | FDNYD 5.5-110 × 8 | Yellow | 0.8 × 2.8 | 0.35 | 3.3 | 5.7 | 3.4 | 22.0 | 22.0 | 13.0 |
| FNY 5.5-187 × 5 | FDNYD 5.5-187 × 5 | Yellow | 0.5 × 4.75 | 0.4 | 5.0 | 5.7 | 3.4 | 23.0 | 23.0 | 13.0 |
| FNY 5.5-187 × 8 | FDNYD 5.5-187 × 8 | Yellow | 0.8 × 4.75 | 0.4 | 5.0 | 5.7 | 3.4 | 23.0 | 23.0 | 13.0 |
| FNY 5.5-250 | FDNYD 5.5-250 | Yellow | 0.8 × 6.35 | 0.4 | 6.6 | 5.7 | 3.4 | 24.4 | 24.4 | 13.0 |
| FNY 5.5-312 | FDNYD 5.5-312 | Yellow | 0.8 × 8.0 | 0.5 | 8.2 | 5.7 | 3.4 | 28.3 | 28.3 | 13.0 |
| FNY 5.5-375 | FDNYD 5.5-375 | Yellow | 1.2 × 9.4 | 0.5 | 9.9 | 5.7 | 3.4 | 30.6 | 30.6 | 13.0 |


Auswahlhilfe
Select the conductor group and FNY or FDNYD crimp construction, then match the NEMA tab size to the intended mating tab. Check B, D, d, L1/L2 and E against available space and quote the exact model code when ordering.