YOCL

HSC-F 4:1 Dual-Wall Heat Shrink Waterproof End Cap

YOCL ELECTRIC HSC-F adhesive-lined heat shrink end caps seal and insulate cable ends with a closed-end, dual-wall design.

  • 4:1 shrink ratio; models HSC-F-1, HSC-F-2 and HSC-F-3.
  • Radiation-modified polyolefin outer layer and hot-melt adhesive lining.
  • Operating temperature: -45°C to +125°C.
  • Initial shrink: ≥70°C; full shrink: ≥125°C.
  • Standard colors: Black and Transparent.
  • Black outer layer: self-extinguishing ≤30 seconds, with SAE-AMS-DTL-23053/5 as the test reference.
Inquire about this product

Overview

YOCL ELECTRIC HSC-F heat shrink end caps seal and protect cable ends, wire-harness terminations and unused electrical cable ends against moisture and environmental exposure. The closed-end structure covers the termination, while the open end recovers around the cable.

The dual-wall construction combines a radiation-modified polyolefin outer layer with hot-melt adhesive lining. During heating, the outer layer shrinks and the adhesive softens and flows around the cable surface. After cooling, the adhesive helps form a sealed interface for waterproof sealing, moisture protection and electrical insulation.

The HSC-F series offers a 4:1 shrink ratio, three models and Black or Transparent color options.

Features

  • Closed-end sealing: Covers the exposed cable termination for cable-end protection.
  • Dual-wall construction: Combines insulating polyolefin with adhesive-lined environmental sealing.
  • 4:1 recovery: Accommodates different installation and final cable diameters.
  • Three models: HSC-F-1, HSC-F-2 and HSC-F-3 have individual diameter, length and wall specifications.
  • Color choices: Black provides opaque covering; Transparent allows visibility of the protected area.
  • Black outer-layer flame performance: Self-extinguishing ≤30 seconds with SAE-AMS-DTL-23053/5 as the supplied test reference.

Technical Specifications

Parameter Specification
Brand YOCL ELECTRIC
Series HSC-F
Product type Dual-wall heat shrink waterproof end cap
Construction Dual wall / Closed end
Shrink ratio 4:1
Outer layer Radiation-modified polyolefin
Inner layer Hot-melt adhesive
Models HSC-F-1 / HSC-F-2 / HSC-F-3
Standard lengths 30/35 mm for HSC-F-1 and HSC-F-2; 40/50 mm for HSC-F-3
Initial shrink temperature ≥70°C
Full shrink temperature ≥125°C
Operating temperature -45°C to +125°C
Standard colors Black / Transparent
Black outer-layer flame performance Self-extinguishing ≤30 seconds
Flame test reference SAE-AMS-DTL-23053/5
Environmental standard RoHS

The self-extinguishing result applies to the black outer layer. Initial and full shrink temperatures describe recovery; the operating range describes service conditions.

Outer-Layer Performance

Property Specification Supplied test method or condition
Tensile strength ≥10.4 MPa ASTM D2671
Elongation at break ≥300% ASTM D2671
Tensile strength after aging ≥7.3 MPa 158°C × 168 h
Elongation after aging ≥100% 158°C × 168 h
Axial change -8% to +8% ASTM D2671
Flame retardancy, black outer layer Self-extinguishing ≤30 seconds SAE-AMS-DTL-23053/5
Thermal shock No cracks / No dripping ASTM D2671; 225°C × 4 h
Cold bending No crack ASTM D2671; -40°C × 4 h
Water absorption <0.50% ASTM D2671
Volume resistivity ≥1 × 10¹⁴ Ω·cm IEC 60093
Breakdown strength ≥22 kV/mm IEC 60243

Heat aging, thermal shock and cold bending temperatures are test conditions. The specified operating range remains -45°C to +125°C.

Dimension

HSC-F 4:1 Dual-Wall Heat Shrink Waterproof End Cap dimension drawing

Model Standard Length Supplied I.D. Max. I.D. After Recovery Total Wall Thickness Outer Wall Thickness Adhesive Layer Thickness
HSC-F-1 30/35 mm ≥5.72 mm ≤1.27 mm ≥1.20 mm ≥0.64 mm ≥0.56 mm
HSC-F-2 30/35 mm ≥7.44 mm ≤1.65 mm ≥1.52 mm ≥0.76 mm ≥0.76 mm
HSC-F-3 40/50 mm ≥10.85 mm ≤2.41 mm ≥1.91 mm ≥0.89 mm ≥1.17 mm

The diameter and wall values retain the supplied minimum or maximum limits. Standard length designations 30/35 mm and 40/50 mm identify the listed length options for each model.

Selection Guide

Select the model with a supplied I.D. that passes over the cable termination, then check the maximum recovered I.D. against the cable diameter requiring sealing. Choose a listed length that covers the termination and the required protected cable section.

For example, HSC-F-3 has supplied I.D. ≥10.85 mm, maximum recovered I.D. ≤2.41 mm and standard length options of 40 or 50 mm. Its total wall is ≥1.91 mm, outer wall ≥0.89 mm and adhesive layer ≥1.17 mm.

Select Black when the supplied black outer-layer self-extinguishing specification is required, or Transparent where visibility of the protected area is needed.

Anwendungen

  • Exposed or unused electrical cable ends.
  • Power cable and wire-harness terminations.
  • Cable-end insulation and moisture protection.
  • Cable storage and transportation protection.
  • Electrical equipment cable-end environmental sealing.

Ordering Information

Specify HSC-F-1, HSC-F-2 or HSC-F-3, the listed standard length, Black or Transparent color and required quantity when requesting a quotation from YOCL ELECTRIC. Include the cable-end diameter and required protected length to support selection.