VO-D EMC Metal Cable Glands
VO-D EMC metal cable glands are available in metric, PG, G and NPT thread families. The catalog lists 83 model codes with cable clamping and installation dimensions.
- Metal body options listed: nickel-plated brass, SS304 or SS316L; PA claw and NBR seals.
- Source-stated IP68 depends on the specified cable range and properly seated O-ring; no test report is supplied.
- Match the thread, cable diameter, GL and joint length to the enclosure.
Genel Bakış
VO-D EMC Metal Cable Glands provide cable entry and clamping at electrical enclosures. The supplied catalog shows 83 model codes in metric, PG, G and NPT thread families. The EMC designation comes from the source; no shielding effectiveness value is supplied.
Özellikler
- Four thread families: metric, PG, G and NPT options have separate model tables.
- Cable-specific selection: the stated clamping range differs by model; the listed series covers 3–80 mm cable diameters overall.
- Material options: the source lists nickel-plated brass, SS304 and SS316L bodies, PA claws and NBR sealing components, without assigning a metal option to every model code.
- Catalog-stated IP68: the source conditions its claim on the specified clamping range and O-ring installation. It also prints “10 bar” without a test report or duration.
Teknik Özellikler
| Parameter | Catalog specification |
|---|---|
| Product type | EMC metal cable gland |
| Series | VO-D EMC |
| Listed models | 83 |
| Thread families | Metric, PG, G and NPT |
| Cable diameter range | 3–80 mm across listed models; check each model |
| Body material options | Nickel-plated brass, SS304 or SS316L; code mapping unspecified |
| Claw material | PA |
| Sealing components | NBR |
| Protection degree | IP68 stated by source; conditions and test report not supplied in full |
| Static temperature | −40 to +100 °C; short-term up to +120 °C |
| Dynamic temperature | −20 to +80 °C; short-term up to +100 °C |
| Dimension units | mm |
The source mentions ISO 9001 and TÜV, but no product-specific certificates are supplied. It does not give EMC attenuation, installation torque or a tested chemical-resistance range.
Boyut
Cable diameter ranges below are displayed from minimum to maximum; the source prints the same endpoints in descending order. For the G and NPT families, the printed mounting-hole column is internally inconsistent with thread outside diameters, so those hole values are not published. A dash means the value requires a verified drawing.
PG Thread Models
| Model | Thread | Cable diameter range (mm) | Thread OD (mm) | Mounting hole (mm) | GL (mm) | Joint length H (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|---|
| VO-D.PG7-EMC | PG7 | 3–6.5 | 12.5 | 12.5–12.7 | 7 | 19 | 14 |
| VO-D.PG9-EMC | PG9 | 4–8 | 15.2 | 15.2–15.4 | 8 | 20 | 17 |
| VO-D.PG11-EMC | PG11 | 5–10 | 18.6 | 18.6–18.8 | 8 | 21 | 20/21 |
| VO-D.PG13.5-EMC | PG13.5 | 6–12 | 20.4 | 20.4–20.6 | 8 | 22 | 22 |
| VO-D.PG16-EMC | PG16 | 10–14 | 22.5 | 22.5–22.7 | 9 | 23 | 24 |
| VO-D.PG19-EMC | PG19 | 10–14 | 25 | 25–25.2 | 9 | 25 | 24/27 |
| VO-D.PG21-EMC | PG21 | 13–18 | 28.3 | 28.3–28.5 | 9 | 27 | 30 |
| VO-D.PG25-EMC | PG25 | 15–22 | 32 | 32–32.2 | 10 | 29 | 35 |
| VO-D.PG29-EMC | PG29 | 18–25 | 37 | 37–37.2 | 10 | 31 | 40 |
| VO-D.PG36-EMC | PG36 | 25–33 | 47 | 47–47.2 | 11 | 37 | 50 |
| VO-D.PG42-EMC | PG42 | 32–38 | 54 | 54–54.2 | 13 | 38 | 57 |
| VO-D.PG48-EMC | PG48 | 37–44 | 59.3 | 59.3–59.5 | 14 | 38 | 64 |
| VO-D.PG63-EMC | PG63 | 42–52 | 72 | 72–72.2 | 15 | 42 | 78 |
Metric Thread Models
| Model | Thread | Cable diameter range (mm) | Thread OD (mm) | Mounting hole (mm) | GL (mm) | Joint length H (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|---|
| VO-D.M12-EMC | M12×1.5 | 3–6.5 | 12 | 12–12.2 | 7 | 19 | 14 |
| VO-D.M14-EMC | M14×1.5 | 4–8 | 14 | 14–14.2 | 7 | 19 | 17 |
| VO-D.M16-EMC | M16×1.5 | 4–8 | 16 | 16–16.2 | 8 | 20 | 18 |
| VO-D.M18-EMC | M18×1.5 | 5–10 | 18 | 18–18.2 | 8 | 21 | 20 |
| VO-D.M20-EMC | M20×1.5 | 6–12 | 20 | 20–20.2 | 8 | 22 | 22 |
| VO-D.M22-EMC | M22×1.5 | 10–14 | 22 | 22–22.2 | 8 | 23 | 24 |
| VO-D.M24-EMC | M24×1.5 | 10–14 | 24 | 24–24.2 | 9 | 25 | 24/27 |
| VO-D.M25A-EMC | M25×1.5 | 10–14 | 25 | 25–25.2 | 9 | 25 | 24/27 |
| VO-D.M25B-EMC | M25×1.5 | 13–18 | 25 | 25–25.2 | 9 | 27 | 30/27 |
| VO-D.M27A-EMC | M27×1.5 | 13–18 | 27 | 27–27.2 | 9 | 27 | 30 |
| VO-D.M27B-EMC | M27×2 | 13–18 | 27 | 27–27.2 | 9 | 27 | 30 |
| VO-D.M28A-EMC | M28×1.5 | 13–18 | 28 | 28–28.2 | 9 | 27 | 30 |
| VO-D.M28B-EMC | M28×2 | 13–18 | 28 | 28–28.2 | 9 | 27 | 30 |
| VO-D.M30A-EMC | M30×1.5 | 13–18 | 30 | 30–30.2 | 9 | 29 | 30/32 |
| VO-D.M30B-EMC | M30×2 | 13–18 | 30 | 30–30.2 | 9 | 29 | 30/32 |
| VO-D.M32A-EMC | M32×1.5 | 15–22 | 32 | 32–32.2 | 10 | 29 | 35 |
| VO-D.M32B-EMC | M32×2 | 15–22 | 32 | 32–32.2 | 10 | 29 | 35 |
| VO-D.M33A-EMC | M33×1.5 | 15–22 | 33 | 33–33.2 | 10 | 29 | 35 |
| VO-D.M33B-EMC | M33×2 | 15–22 | 33 | 33–33.2 | 10 | 29 | 35 |
| VO-D.M36A-EMC | M36×1.5 | 18–25 | 36 | 36–36.2 | 10 | 31 | 40 |
| VO-D.M36B-EMC | M36×2 | 18–25 | 36 | 36–36.2 | 10 | 31 | 40 |
| VO-D.M37A-EMC | M37×1.5 | 18–25 | 37 | 37–37.2 | 10 | 31 | 40 |
| VO-D.M37B-EMC | M37×2 | 18–25 | 37 | 37–37.2 | 10 | 31 | 40 |
| VO-D.M40A-EMC | M40×1.5 | 18–25 | 40 | 40–40.2 | 11 | 31 | 40/45 |
| VO-D.M40B-EMC | M40×2 | 18–25 | 40 | 40–40.2 | 11 | 31 | 40/45 |
| VO-D.M40C-EMC | M40×1.5 | 22–30 | 40 | 40–40.2 | 11 | 35 | 45 |
| VO-D.M40D-EMC | M40×2 | 22–30 | 40 | 40–40.2 | 11 | 35 | 45 |
| VO-D.M42A-EMC | M42×1.5 | 22–30 | 42 | 42–42.2 | 11 | 35 | 45 |
| VO-D.M42B-EMC | M42×2 | 22–30 | 42 | 42–42.2 | 11 | 35 | 45 |
| VO-D.M47A-EMC | M47×1.5 | 25–33 | 47 | 47–47.2 | 11 | 37 | 50 |
| VO-D.M47B-EMC | M47×2 | 25–33 | 47 | 47–47.2 | 11 | 37 | 50 |
| VO-D.M48A-EMC | M48×1.5 | 25–33 | 48 | 48–48.2 | 11 | 37 | 50/52 |
| VO-D.M48B-EMC | M48×2 | 25–33 | 48 | 48–48.2 | 11 | 37 | 50/52 |
| VO-D.M50A-EMC | M50×1.5 | 32–38 | 50 | 50–50.2 | 12 | 37 | 50/55 |
| VO-D.M50B-EMC | M50×2 | 32–38 | 50 | 50–50.2 | 12 | 37 | 50/55 |
| VO-D.M54A-EMC | M54×1.5 | 32–38 | 54 | 54–54.2 | 12 | 38 | 57 |
| VO-D.M54B-EMC | M54×2 | 32–38 | 54 | 54–54.2 | 12 | 38 | 57 |
| VO-D.M56A-EMC | M56×1.5 | 32–38 | 56 | 56–56.2 | 12 | 38 | 57/59 |
| VO-D.M56B-EMC | M56×2 | 32–38 | 56 | 56–56.2 | 12 | 38 | 57/59 |
| VO-D.M60A-EMC | M60×1.5 | 37–44 | 60 | 60–60.2 | 13 | 38 | 64 |
| VO-D.M60B-EMC | M60×2 | 37–44 | 60 | 60–60.2 | 13 | 38 | 64 |
| VO-D.M63A-EMC | M63×1.5 | 37–44 | 63 | 63–63.2 | 13 | 38 | 64/68 |
| VO-D.M63B-EMC | M63×2 | 37–44 | 63 | 63–63.2 | 13 | 38 | 64/68 |
| VO-D.M64A-EMC | M64×1.5 | 37–44 | 64 | 64–64.2 | 13 | 38 | 64/68 |
| VO-D.M64B-EMC | M64×2 | 37–44 | 64 | 64–64.2 | 13 | 38 | 64/68 |
| VO-D.M72-EMC | M72×2 | 42–52 | 72 | 72–72.2 | 15 | 42 | 65/68 |
| VO-D.M75-EMC | M75×2 | 42–52 | 75 | 75–75.2 | 15 | 42 | 78 |
| VO-D.M80-EMC | M80×2 | 50–62 | 80 | 80–80.2 | 15 | 45 | 86/88 |
| VO-D.M88-EMC | M88×2 | 60–70 | 88 | 88–88.2 | 15 | 45 | 98 |
| VO-D.M100-EMC | M100×2 | 70–80 | 100 | 100–100.2 | 15 | 45 | 110 |
G Thread Models
| Model | Thread | Cable diameter range (mm) | Thread OD (mm) | Mounting hole (mm) | GL (mm) | Joint length H (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|---|
| VO-D.G1/4-EMC | G1/4 | 3–6.5 | 13.1 | — | 7 | 19 | 14 |
| VO-D.G3/8-EMC | G3/8 | 4–8 | 16.6 | — | 8 | 19 | 18 |
| VO-D.G1/2-EMC | G1/2 | 6–12 | 20.9 | — | 8 | 22 | 22 |
| VO-D.G3/4-EMC | G3/4 | 13–18 | 26.4 | — | 9 | 25 | 30 |
| VO-D.G1-EMC | G1 | 18–25 | 33.2 | — | 11 | 29 | 40 |
| VO-D.G1-1/4-EMC | G1-1/4 | 25–33 | 41.9 | — | 13 | 35 | 50 |
| VO-D.G1-1/2-EMC | G1-1/2 | 32–38 | 47.8 | — | 14 | 37 | 57 |
| VO-D.G2-EMC | G2 | 37–44 | 59.6 | — | 14 | 38 | 64 |
| VO-D.G2-1/2-EMC | G2-1/2 | 42–52 | 75.1 | — | 15 | 38 | 77 |
| VO-D.G3-EMC | G3 | 65–70 | 87.8 | — | 15 | 48 | 94 |
NPT Thread Models
| Model | Thread | Cable diameter range (mm) | Thread OD (mm) | Mounting hole (mm) | GL (mm) | Joint length H (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|---|
| VO-D.NPT1/4-EMC | NPT1/4 | 3–6.5 | 13.6 | — | 7 | 19 | 14 |
| VO-D.NPT3/8-EMC | NPT3/8 | 4–8 | 17 | — | 8 | 19 | 18 |
| VO-D.NPT1/2-EMC | NPT1/2 | 6–12 | 21.2 | — | 8 | 22 | 22 |
| VO-D.NPT3/4-EMC | NPT3/4 | 13–18 | 26.5 | — | 9 | 25 | 30 |
| VO-D.NPT1-EMC | NPT1 | 18–25 | 33.2 | — | 11 | 29 | 40 |
| VO-D.NPT1-1/4-EMC | NPT1-1/4 | 25–33 | 41.9 | — | 13 | 35 | 50 |
| VO-D.NPT1-1/2-EMC | NPT1-1/2 | 32–38 | 48 | — | 14 | 37 | 57 |
| VO-D.NPT2-EMC | NPT2 | 37–44 | 60 | — | 14 | 38 | 64 |
| VO-D.NPT2-1/2-EMC | NPT2-1/2 | 42–52 | 72.6 | — | 15 | 38 | 78 |
| VO-D.NPT3-EMC | NPT3 | 65–70 | 88.6 | — | 15 | 45 | 98 |
Seçim Kılavuzu
Specify the complete VO-D EMC model by cable outside diameter and mating thread. Verify the enclosure opening for G and NPT models against a current technical drawing. Confirm the required body metal and sealing arrangement with the supplier before ordering.
Boyut